{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T05:38:17Z","timestamp":1781415497874,"version":"3.54.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T00:00:00Z","timestamp":1757116800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T00:00:00Z","timestamp":1757116800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100019600","name":"Hanoi University of Science and Technology","doi-asserted-by":"crossref","award":["T2023-T\u0110-017"],"award-info":[{"award-number":["T2023-T\u0110-017"]}],"id":[{"id":"10.13039\/100019600","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"DOI":"10.1007\/s11548-025-03511-0","type":"journal-article","created":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T11:14:35Z","timestamp":1757157275000},"page":"635-650","update-policy":"https:\/\/2.zoppoz.workers.dev:443\/https\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Tactile force sensor based on a modified acoustic reflection principle for intraoperative tumor localization in minimally invasive surgery"],"prefix":"10.1007","volume":"21","author":[{"ORCID":"https:\/\/2.zoppoz.workers.dev:443\/https\/orcid.org\/0000-0002-7878-6053","authenticated-orcid":false,"given":"Hoang-Hiep","family":"Ly","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manh-Cuong","family":"Bui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ba-Nghia","family":"Mai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hai-Duong","family":"Phung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huy-Anh","family":"Bui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Duc-Tung","family":"Ta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thi-Thoa","family":"Mac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/2.zoppoz.workers.dev:443\/https\/orcid.org\/0000-0001-7111-4038","authenticated-orcid":false,"given":"Xuan-Thuan","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,6]]},"reference":[{"issue":"1","key":"3511_CR1","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1055\/s-2004-814113","volume":"36","author":"TN Robinson","year":"2004","unstructured":"Robinson TN, Stiegmann GV (2004) Minimally invasive surgery. Endoscopy 36(1):48\u201351","journal-title":"Endoscopy"},{"issue":"14","key":"3511_CR2","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1001\/jama.2009.1451","volume":"302","author":"JC Hu","year":"2009","unstructured":"Hu JC, Gu X, Lipsitz SR, Barry MJ, D\u2019Amico AV, Weinberg AC, Keating NL (2009) Comparative effectiveness of minimally invasive vs open radical prostatectomy. J Am Med Assoc 302(14):1557\u20131564","journal-title":"J Am Med Assoc"},{"issue":"4","key":"3511_CR3","doi-asserted-by":"publisher","first-page":"965","DOI":"10.1115\/1.4000421","volume":"3","author":"AL Trejos","year":"2009","unstructured":"Trejos AL, Patel RV, Naish MD, Lyle AC, Schlachta CM (2009) A sensorized instrument for skills assessment and training in minimally invasive surgery. J Med Devices 3(4):965\u2013970","journal-title":"J Med Devices"},{"key":"3511_CR4","doi-asserted-by":"crossref","unstructured":"Alexander R, Vaccaro AR, Bono CM (2007) Minimally Invasive Spine Surgery. Taylor & Francis Group","DOI":"10.3109\/9781420013962"},{"issue":"1","key":"3511_CR5","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1108\/01439910310457670","volume":"30","author":"MC \u00c7avusoglu","year":"2003","unstructured":"\u00c7avusoglu MC, Williams W, Tendick F, Sastry SS (2003) Robotics for telesurgery: second generation Berkeley\/UCSF laparoscopic telesurgical workstation and looking towards the future applications. Ind Robot: Int J 30(1):22\u201329","journal-title":"Ind Robot: Int J"},{"key":"3511_CR6","doi-asserted-by":"crossref","unstructured":"Semere W, Kitagawa M, Okamura AM (2004) Teleoperation with sensor\/actuator asymmetry: task performance with partial force feedback. In: Proceedings of the IEEE international symposium on haptic interfaces for virtual environment and teleoperator systems.","DOI":"10.1109\/HAPTIC.2004.1287186"},{"key":"3511_CR7","doi-asserted-by":"crossref","unstructured":"Wagner CR, Stylopoulos N, Howe RD (2002) The role of force feedback in surgery: analysis of blunt dissection. In: Proceedings of the IEEE symposium on haptic interfaces for virtual environment and teleoperator systems, pp 73\u201373.","DOI":"10.1109\/HAPTIC.2002.998943"},{"key":"3511_CR8","unstructured":"Braun EU, Mayer H, Knoll A, Lange R, Bauernschmitt R (2008) The must-have in robotic heart surgery: haptic feedback. In: Medical Robotics, pp 9\u201320"},{"issue":"1","key":"3511_CR9","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1109\/TOH.2023.3346479","volume":"18","author":"W Duan","year":"2025","unstructured":"Duan W, Li Z, Omisore OM, Du W, Akinyemi TO, Chen X, Gao X, Wang H, Wang L (2025) Development of an intuitive interface with haptic enhancement for robot-assisted endovascular intervention. IEEE Trans Haptics 18(1):80\u201392","journal-title":"IEEE Trans Haptics"},{"key":"3511_CR10","doi-asserted-by":"publisher","first-page":"167795","DOI":"10.1109\/ACCESS.2021.3135698","volume":"9","author":"HH Ly","year":"2021","unstructured":"Ly HH, Tanaka Y, Fujiwara M (2021) Tumor depth and size perception using a pneumatic tactile display in laparoscopic surgery. IEEE Access 9:167795\u2013167811","journal-title":"IEEE Access"},{"issue":"5","key":"3511_CR11","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1177\/0954411914533679","volume":"228","author":"M Li","year":"2014","unstructured":"Li M, Liu H, Jiang A, Seneviratne LD, Dasgupta P, Althoefer K, Wurdemann H (2014) Intra-operative tumour localisation in robot-assisted minimally invasive surgery: a review. Proc Inst Mech Eng H J Eng Med 228(5):509\u2013522","journal-title":"Proc Inst Mech Eng H J Eng Med"},{"key":"3511_CR12","doi-asserted-by":"crossref","unstructured":"Gwilliam JC, Pezzementi Z, Jantho E, Okamura AM, Hsiao S (2010) Human vs. robotic tactile sensing: Detecting lumps in soft tissue. In: 2010 IEEE haptics symposium, pp 21\u201328","DOI":"10.1109\/HAPTIC.2010.5444685"},{"issue":"9","key":"3511_CR13","doi-asserted-by":"publisher","first-page":"3283","DOI":"10.1109\/JSEN.2014.2328182","volume":"14","author":"H Xie","year":"2014","unstructured":"Xie H, Liu H, Seneviratne LD, Althoefer K (2014) An optical tactile array probe head for tissue palpation during minimally invasive surgery. IEEE Sens J 14(9):3283\u20133291","journal-title":"IEEE Sens J"},{"issue":"3","key":"3511_CR14","doi-asserted-by":"publisher","first-page":"4560","DOI":"10.1021\/acsami.0c20392","volume":"13","author":"Y Tang","year":"2021","unstructured":"Tang Y, Liu H, Pan J, Zhang Z, Xu Y, Yao N, Zhang L, Tong L (2021) Optical micro\/nanofiber-enabled compact tactile sensor for hardness discrimination. ACS Appl Mater Interfaces 13(3):4560\u20134566","journal-title":"ACS Appl Mater Interfaces"},{"issue":"4","key":"3511_CR15","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1109\/TMECH.2011.2116033","volume":"17","author":"P Puangmali","year":"2012","unstructured":"Puangmali P, Liu H, Seneviratne LD, Dasgupta P, Althoefer K (2012) Miniature 3-axis distal force sensor for minimally invasive surgical palpation. IEEE ASME Trans Mechatron 17(4):646\u2013656","journal-title":"IEEE ASME Trans Mechatron"},{"issue":"2","key":"3511_CR16","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1007\/s10439-019-02388-w","volume":"48","author":"C Lv","year":"2020","unstructured":"Lv C, Wang S, Shi C (2020) A high-precision and miniature fiber bragg grating-based force sensor for tissue palpation during minimally invasive surgery. Ann Biomed Eng 48(2):669\u2013681","journal-title":"Ann Biomed Eng"},{"issue":"2","key":"3511_CR17","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1109\/TMECH.2021.3071437","volume":"27","author":"W Lai","year":"2021","unstructured":"Lai W, Cao L, Liu J, Tjin SC, Phee SJ (2021) A three-axial force sensor based on fiber Bragg gratings for surgical robots. IEEE ASME Trans Mechatron 27(2):777\u2013789","journal-title":"IEEE ASME Trans Mechatron"},{"key":"3511_CR18","first-page":"1","volume":"72","author":"L Gan","year":"2021","unstructured":"Gan L, Duan W, Akinyemi TO, Du W, Omisore OM, Wang L (2021) Development of a fiber bragg grating-based force sensor for minimally invasive surgery\u2013case study of ex-vivo tissue palpation. IEEE Trans Instrum Meas 72:1\u201312","journal-title":"IEEE Trans Instrum Meas"},{"issue":"2\u20133","key":"3511_CR19","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.sna.2004.01.038","volume":"112","author":"S Omata","year":"2004","unstructured":"Omata S, Murayama Y, Constantinou CE (2004) Real time robotic tactile sensor system for the determination of the physical properties of biomaterials. Sens Actuators, A 112(2\u20133):278\u2013285","journal-title":"Sens Actuators, A"},{"issue":"2","key":"3511_CR20","doi-asserted-by":"publisher","first-page":"025033","DOI":"10.1088\/1361-665X\/aafc8d","volume":"28","author":"F Ju","year":"2019","unstructured":"Ju F, Wang Y, Zhang Z, Wang Y, Yun Y, Guo H, Chen B (2019) A miniature piezoelectric spiral tactile sensor for tissue hardness palpation with catheter robot in minimally invasive surgery. Smart Mater Struct 28(2):025033","journal-title":"Smart Mater Struct"},{"issue":"4","key":"3511_CR21","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1088\/0964-1726\/16\/4\/006","volume":"16","author":"S Sokhanvar","year":"2007","unstructured":"Sokhanvar S, Packirisamy M, Dargahi J (2007) A multifunctional PVDF-based tactile sensor for minimally invasive surgery. Smart Mater Struct 16(4):989","journal-title":"Smart Mater Struct"},{"issue":"3","key":"3511_CR22","doi-asserted-by":"publisher","first-page":"2755","DOI":"10.1109\/TIE.2017.2739681","volume":"65","author":"U Kim","year":"2017","unstructured":"Kim U, Kim YB, Seok DY, So J, Choi HR (2017) A surgical palpation probe with 6-axis force\/torque sensing capability for minimally invasive surgery. IEEE Trans Ind Electron 65(3):2755\u20132765","journal-title":"IEEE Trans Ind Electron"},{"issue":"1","key":"3511_CR23","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1109\/TMECH.2016.2623743","volume":"22","author":"AS Naidu","year":"2016","unstructured":"Naidu AS, Patel RV, Naish MD (2016) Low-cost disposable tactile sensors for palpation in minimally invasive surgery. IEEE ASME Trans Mechatron 22(1):127\u2013137","journal-title":"IEEE ASME Trans Mechatron"},{"key":"3511_CR24","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s11548-020-02294-w","volume":"16","author":"HH Ly","year":"2021","unstructured":"Ly HH, Tanaka Y, Fujiwara M (2021) A tactile sensor using the acoustic reflection principle for assessing the contact force component in laparoscopic tumor localization. Int J Comput Assist Radiol Surg 16:289\u2013299","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"3511_CR25","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1109\/TOH.2012.64","volume":"6","author":"A Talasaz","year":"2012","unstructured":"Talasaz A, Patel RV (2012) Integration of force reflection with tactile sensing for minimally invasive robotics-assisted tumor localization. IEEE Trans Haptics 6(2):217\u2013228","journal-title":"IEEE Trans Haptics"},{"issue":"2","key":"3511_CR26","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1109\/TBME.2009.2032164","volume":"57","author":"H Liu","year":"2010","unstructured":"Liu H, Noonan DP, Challacombe BJ, Dasgupta P, Seneviratne LD, Althoefer K (2010) Rolling mechanical imaging for tissue abnormality localization during minimally invasive surgery. IEEE Trans Biomed Eng 57(2):404\u2013414","journal-title":"IEEE Trans Biomed Eng"},{"key":"3511_CR27","volume-title":"Medical devices: regulations, standards and practices","author":"S Ramakrishna","year":"2015","unstructured":"Ramakrishna S, Tian L, Wang C, Liao S, Teo WE (2015) Medical devices: regulations, standards and practices. Woodhead Publishing"},{"key":"3511_CR28","first-page":"e44","volume":"9","author":"RM Fish","year":"2009","unstructured":"Fish RM, Geddes LA (2009) Conduction of electrical current to and through the human body: a review. Eplasty 9:e44","journal-title":"Eplasty"},{"issue":"7","key":"3511_CR29","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.1243\/09544062JMES1917","volume":"224","author":"AL Trejos","year":"2010","unstructured":"Trejos AL, Patel RV, Naish MD (2010) Force sensing and its application in minimally invasive surgery and therapy: a survey. Proc Inst Mech Eng C-J Mech Eng Sci 224(7):1435\u20131454","journal-title":"Proc Inst Mech Eng C-J Mech Eng Sci"},{"issue":"4","key":"3511_CR30","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1002\/rcs.413","volume":"7","author":"M Kalantari","year":"2011","unstructured":"Kalantari M, Ramezanifard M, Ahmadi R, Dargahi J, K\u00f6vecses J (2011) A piezoresistive tactile sensor for tissue characterization during catheter-based cardiac surgery. Int J Med Robot 7(4):431\u2013440","journal-title":"Int J Med Robot"},{"key":"3511_CR31","doi-asserted-by":"crossref","unstructured":"Yang Y, Hao Z (2015). A Microfluidic-Based Tactile Sensor for 3-Dof Force\/Torque Detection. In: Proceedings of the International Electronic Packaging Technical Conference and Exhibition (56901): pp V003T07A010.","DOI":"10.1115\/IPACK2015-48133"},{"key":"3511_CR32","doi-asserted-by":"crossref","unstructured":"Yang Y, Johnson G, Krusienski D, Guo S, Lin C, Hao Z (2016) A microfluidic-based tactile sensor for palpating mice tumor tissues. In: Proceeding of the international conference on biomedical electronics and devices 2, pp. 83-92","DOI":"10.5220\/0005705600830092"},{"issue":"2","key":"3511_CR33","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s11548-014-1067-z","volume":"10","author":"Y Tanaka","year":"2015","unstructured":"Tanaka Y, Fukuda T, Fujiwara M, Sano A (2015) Tactile sensor using acoustic reflection for lump detection in laparoscopic surgery. Int J Comput Assist Radiol Surg 10(2):183\u2013193","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3511_CR34","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1007\/s11548-017-1592-7","volume":"12","author":"HH Ly","year":"2017","unstructured":"Ly HH, Tanaka Y, Fukuda T, Sano A (2017) Grasper having tactile sensing function using acoustic reflection for laparoscopic surgery. Int J Comput Assist Radiol Surg 12:1333\u20131343","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3511_CR35","doi-asserted-by":"crossref","unstructured":"Hiep LH, Thoa MT (2023) A Novel Acoustic Reflection Principle for Developing Tactile Sensors Integrated with Catheters for Cardiac Ablation. In: Proceedings of the 1st International Conference on Health Science and Technology (ICHST), Hanoi, Vietnam.","DOI":"10.1109\/ICHST59286.2023.10565340"},{"issue":"2","key":"3511_CR36","doi-asserted-by":"publisher","first-page":"021020","DOI":"10.1115\/1.2898712","volume":"130","author":"J Rosen","year":"2008","unstructured":"Rosen J, Brown JD, De S, Sinanan M, Hannaford B (2008) Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. J Biomech Eng 130(2):021020","journal-title":"J Biomech Eng"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03511-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/article\/10.1007\/s11548-025-03511-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03511-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T10:21:13Z","timestamp":1774866073000},"score":1,"resource":{"primary":{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/10.1007\/s11548-025-03511-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,6]]},"references-count":36,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,3]]}},"alternative-id":["3511"],"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/doi.org\/10.1007\/s11548-025-03511-0","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,6]]},"assertion":[{"value":"10 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}