{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T15:16:22Z","timestamp":1783696582692,"version":"3.55.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002745","name":"Bayerische Forschungsstiftung","doi-asserted-by":"publisher","award":["AZ-1592-23-ForNeRo"],"award-info":[{"award-number":["AZ-1592-23-ForNeRo"]}],"id":[{"id":"10.13039\/501100002745","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Multi-Scale Medical Robotics Center, AIR@InnoHK"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Purpose<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>Spinal instability is a widespread condition that causes pain, fatigue, and restricted mobility, profoundly affecting patients\u2019 quality of life. In clinical practice, the gold standard for diagnosis is dynamic X-ray imaging. However, X-ray provides only 2D motion information, while 3D modalities such as computed tomography (CT) or cone beam computed tomography (CBCT) cannot efficiently capture motion. Therefore, there is a need for a system capable of visualizing real-time 3D spinal motion while minimizing radiation exposure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Methods<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>We propose ultrasound as an auxiliary modality for 3D spine visualization. Due to acoustic limitations, ultrasound captures only the superficial spinal surface. Therefore, the partially compounded ultrasound volume is registered to preoperative 3D imaging. In this study, CBCT provides the neutral spine configuration, while robotic ultrasound acquisition is performed at maximal spinal bending. A kinematic model is applied to the CBCT-derived spine model for coarse registration, followed by ICP for fine registration, with kinematic parameters optimized based on the registration results. Real-time ultrasound motion tracking is then used to estimate continuous 3D spinal motion by interpolating between the neutral and maximally bent states.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Results<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>\n                      The pipeline was evaluated on a bendable 3D-printed lumbar spine phantom. The registration error was\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$1.941 \\pm 0.199$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"https:\/\/2.zoppoz.workers.dev:443\/http\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:mrow>\n                              <mml:mn>1.941<\/mml:mn>\n                              <mml:mo>\u00b1<\/mml:mo>\n                              <mml:mn>0.199<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      mm, and the interpolated spinal motion error was\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$2.01 \\pm 0.309$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"https:\/\/2.zoppoz.workers.dev:443\/http\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:mrow>\n                              <mml:mn>2.01<\/mml:mn>\n                              <mml:mo>\u00b1<\/mml:mo>\n                              <mml:mn>0.309<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      mm (median).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Conclusion<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>The proposed robotic ultrasound framework enables radiation-reduced, real-time 3D visualization of spinal motion, offering a promising 3D alternative to conventional dynamic X-ray imaging for assessing spinal instability.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-026-03627-x","type":"journal-article","created":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T15:46:16Z","timestamp":1776440776000},"page":"989-996","update-policy":"https:\/\/2.zoppoz.workers.dev:443\/https\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ultrasound-guided real-time spinal motion visualization for spinal instability assessment"],"prefix":"10.1007","volume":"21","author":[{"ORCID":"https:\/\/2.zoppoz.workers.dev:443\/https\/orcid.org\/0000-0003-2717-8274","authenticated-orcid":false,"given":"Feng","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan","family":"Bi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianyu","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhongliang","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nassir","family":"Navab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,17]]},"reference":[{"issue":"1","key":"3627_CR1","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.ejrad.2012.07.023","volume":"82","author":"R Izzo","year":"2013","unstructured":"Izzo R, Guarnieri G, Guglielmi G, Muto M (2013) Biomechanics of the spine. part ii: spinal instability. Eur J Radiol 82(1):127\u2013138","journal-title":"Eur J Radiol"},{"issue":"1\u2013suppl","key":"3627_CR2","first-page":"0036","volume":"6","author":"KZ Lim","year":"2016","unstructured":"Lim KZ, Troupis JM, Daly C, Oehme D, Goldschlager T (2016) Indications for use of dynamic four-dimensional computed tomography in diagnosing instability in spinal cervical conditions. Global Spine J 6(1\u2013suppl):0036","journal-title":"Global Spine J"},{"issue":"7","key":"3627_CR3","doi-asserted-by":"publisher","first-page":"1667","DOI":"10.1007\/s00586-022-07233-8","volume":"31","author":"N Winn","year":"2022","unstructured":"Winn N, Kaur S, Cassar-Pullicino V, Ockendon M (2022) A novel use of cone beam ct: flexion and extension weight-bearing imaging to assess spinal stability. Eur Spine J 31(7):1667\u20131681","journal-title":"Eur Spine J"},{"key":"3627_CR4","doi-asserted-by":"publisher","first-page":"17","DOI":"10.4103\/sni.sni_359_17","volume":"9","author":"AA Esmailiejah","year":"2018","unstructured":"Esmailiejah AA, Abbasian M, Bidar R, Esmailiejah N, Safdari F, Amirjamshidi A (2018) Diagnostic efficacy of clinical tests for lumbar spinal instability. Surg Neurol Int 9:17","journal-title":"Surg Neurol Int"},{"issue":"5","key":"3627_CR5","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1302\/0301-620X.103B5.BJJ-2020-1064.R2","volume":"103","author":"L Buzzatti","year":"2021","unstructured":"Buzzatti L, Keelson B, Vanlauwe J, Buls N, De Mey J, Vandemeulebroucke J, Cattrysse E, Scheerlinck T (2021) Evaluating lower limb kinematics and pathology with dynamic ct: a narrative review. Bone Joint J 103(5):822\u2013827","journal-title":"Bone Joint J"},{"issue":"3","key":"3627_CR6","first-page":"20210038","volume":"8","author":"SW Yip","year":"2022","unstructured":"Yip SW, Griffith JF, Lee RK, Liu KL (2022) 4d ct to assess spinal instability in developmental anomaly of posterior arch of atlas. BJR| case reports 8(3):20210038","journal-title":"BJR| case reports"},{"key":"3627_CR7","doi-asserted-by":"crossref","unstructured":"Bi Y, Jiang Z, Duelmer F, Huang D, Navab N (2024) Machine learning in robotic ultrasound imaging: Challenges and perspectives. Annual Review of Control Robotics and Autonomous Systems 7","DOI":"10.1146\/annurev-control-091523-100042"},{"key":"3627_CR8","doi-asserted-by":"publisher","first-page":"102878","DOI":"10.1016\/j.media.2023.102878","volume":"89","author":"Z Jiang","year":"2023","unstructured":"Jiang Z, Salcudean SE, Navab N (2023) Robotic ultrasound imaging: State-of-the-art and future perspectives. Med Image Anal 89:102878","journal-title":"Med Image Anal"},{"issue":"7","key":"3627_CR9","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1177\/02783649231223547","volume":"43","author":"Z Jiang","year":"2024","unstructured":"Jiang Z, Bi Y, Zhou M, Hu Y, Burke M, Navab N (2024) Intelligent robotic sonographer: Mutual information-based disentangled reward learning from few demonstrations. Int J Robot Res 43(7):981\u20131002","journal-title":"Int J Robot Res"},{"issue":"11","key":"3627_CR10","doi-asserted-by":"publisher","first-page":"3234","DOI":"10.1109\/TBME.2020.2980540","volume":"67","author":"T Ungi","year":"2020","unstructured":"Ungi T, Greer H, Sunderland KR, Wu V, Baum ZM, Schlenger C, Oetgen M, Cleary K, Aylward SR, Fichtinger G (2020) Automatic spine ultrasound segmentation for scoliosis visualization and measurement. IEEE Trans Biomed Eng 67(11):3234\u20133241","journal-title":"IEEE Trans Biomed Eng"},{"key":"3627_CR11","first-page":"1","volume":"70","author":"C Yang","year":"2021","unstructured":"Yang C, Jiang M, Chen M, Fu M, Li J, Huang Q (2021) Automatic 3-d imaging and measurement of human spines with a robotic ultrasound system. IEEE Trans Instrum Meas 70:1\u201313","journal-title":"IEEE Trans Instrum Meas"},{"issue":"9","key":"3627_CR12","doi-asserted-by":"publisher","first-page":"5966","DOI":"10.1109\/LRA.2023.3300592","volume":"8","author":"Y Wang","year":"2023","unstructured":"Wang Y, Liu T, Hu X, Yang K, Zhu Y, Jin H (2023) Compliant joint based robotic ultrasound scanning system for imaging human spine. IEEE Robot Automat Lett 8(9):5966\u20135973","journal-title":"IEEE Robot Automat Lett"},{"issue":"6","key":"3627_CR13","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1007\/s11548-018-1759-x","volume":"13","author":"J Esteban","year":"2018","unstructured":"Esteban J, Simson W, Requena Witzig S, Rienm\u00fcller A, Virga S, Frisch B, Zettinig O, Sakara D, Ryang Y-M, Navab N et al (2018) Robotic ultrasound-guided facet joint insertion. Int J Comput Assist Radiol Surg 13(6):895\u2013904","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3627_CR14","doi-asserted-by":"crossref","unstructured":"Behnami D, Sedghi A, Anas EMA, Rasoulian A, Seitel A, Lessoway V, Ungi T, Yen D, Osborn J, Mousavi P et al (2017) Model-based registration of preprocedure mr and intraprocedure us of the lumbar spine. Int J Comput Assist Radiol Surg 12(6):973\u2013982","DOI":"10.1007\/s11548-017-1552-2"},{"key":"3627_CR15","doi-asserted-by":"crossref","unstructured":"Nagpal S, Abolmaesumi P, Rasoulian A, Ungi T, Hacihaliloglu I, Osborn J, Borschneck DP, Lessoway VA, Rohling RN, Mousavi P (2014) Ct to us registration of the lumbar spine: a clinical feasibility study. In: International Conference on Information Processing in Computer-Assisted Interventions, pp. 108\u2013117. Springer","DOI":"10.1007\/978-3-319-07521-1_12"},{"issue":"7","key":"3627_CR16","doi-asserted-by":"publisher","first-page":"1339","DOI":"10.1007\/s11548-024-03126-x","volume":"19","author":"M-A Gafencu","year":"2024","unstructured":"Gafencu M-A, Velikova Y, Saleh M, Ungi T, Navab N, Wendler T, Azampour MF (2024) Shape completion in the dark: completing vertebrae morphology from 3d ultrasound. Int J Comput Assist Radiol Surg 19(7):1339\u20131347","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3627_CR17","doi-asserted-by":"crossref","unstructured":"Gafencu M-A, Shaban R, Velikova Y, Azampour MF, Navab N (2025) Shape completion and real-time visualization in robotic ultrasound spine acquisitions. In: 2025 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 20906\u201320911. IEEE","DOI":"10.1109\/IROS60139.2025.11247644"},{"key":"3627_CR18","doi-asserted-by":"crossref","unstructured":"Teed Z, Deng J (2020) Raft: Recurrent all-pairs field transforms for optical flow. In: European Conference on Computer Vision, pp. 402\u2013419. Springer","DOI":"10.1007\/978-3-030-58536-5_24"},{"issue":"5","key":"3627_CR19","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1097\/AAP.0000000000000136","volume":"39","author":"SJ West","year":"2014","unstructured":"West SJ, Mari J-M, Khan A, Wan JH, Zhu W, Koutsakos IG, Rowe M, Kamming D, Desjardins AE (2014) Development of an ultrasound phantom for spinal injections with 3-dimensional printing. Reg Anesthesia Pain Medi 39(5):429\u2013433","journal-title":"Reg Anesthesia Pain Medi"},{"issue":"7","key":"3627_CR20","doi-asserted-by":"publisher","first-page":"7064","DOI":"10.1109\/TIE.2021.3095787","volume":"69","author":"Z Jiang","year":"2021","unstructured":"Jiang Z, Li Z, Grimm M, Zhou M, Esposito M, Wein W, Stechele W, Wendler T, Navab N (2021) Autonomous robotic screening of tubular structures based only on real-time ultrasound imaging feedback. IEEE Trans Industr Electron 69(7):7064\u20137075","journal-title":"IEEE Trans Industr Electron"},{"issue":"6","key":"3627_CR21","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1007\/s11548-025-03336-x","volume":"20","author":"F Li","year":"2025","unstructured":"Li F, Bi Y, Huang D, Jiang Z, Navab N (2025) Robotic cbct meets robotic ultrasound. Int J Comput Assist Radiol Surg 20(6):1049\u20131057","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"7","key":"3627_CR22","doi-asserted-by":"publisher","first-page":"14364","DOI":"10.1002\/acm2.14364","volume":"25","author":"A Karius","year":"2024","unstructured":"Karius A, Leifeld LM, Strnad V, Fietkau R, Bert C (2024) First implementation of an innovative infra-red camera system integrated into a mobile cbct scanner for applicator tracking in brachytherapy-initial performance characterization. J Appl Clin Med Phys 25(7):14364","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"3627_CR23","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1227\/00006123-198007000-00014","volume":"7","author":"MM Panjabi","year":"1980","unstructured":"Panjabi MM, White AA III (1980) Basic biomechanics of the spine. Neurosurgery 7(1):76\u201393","journal-title":"Neurosurgery"},{"key":"3627_CR24","doi-asserted-by":"crossref","unstructured":"Bi Y, Jiang Z, Clarenbach R, Ghotbi R, Karlas A, Navab N (2023) Mi-segnet: Mutual information-based us segmentation for unseen domain generalization. In: International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 130\u2013140. Springer","DOI":"10.1007\/978-3-031-43901-8_13"},{"key":"3627_CR25","doi-asserted-by":"crossref","unstructured":"Song T, Li F, Bi Y, Karlas A, Yousefi A, Branzan D, Jiang Z, Eck U, Navab N (2025) Intelligent virtual sonographer (ivs): Enhancing physician-robot-patient communication. In: International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 287\u2013297. Springer","DOI":"10.1007\/978-3-032-05127-1_28"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03627-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/article\/10.1007\/s11548-026-03627-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03627-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T14:54:49Z","timestamp":1783695289000},"score":1,"resource":{"primary":{"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/link.springer.com\/10.1007\/s11548-026-03627-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,17]]},"references-count":25,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["3627"],"URL":"https:\/\/2.zoppoz.workers.dev:443\/https\/doi.org\/10.1007\/s11548-026-03627-x","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,17]]},"assertion":[{"value":"19 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}