Rittal TopTherm fan-and-filter unit
System Climate Control
More pressure. Higher air flow rates.
Assembly without tools
Straightforward assembly, exchange
and maintenance with no need for tools of any kind
Simple reversal of the air flow direc-
tion by turning the fan module
Individual positioning of the power
connection
Spring clamp terminals for electrical
connection without tools
Louvred grille latch for fast filter mat
replacement without tools
Performance diagram
250
Efficient technology
Air throughput from 20 to 700 m/h New diagonal fan technology for
200
150 Pst 100
greater pressure stability and constant air flows in use, even with a contaminated filter mat
Minimum installation depth Flow-optimised air routing
50
Extended service life of filter mats
0 100 200 300 . V 400 500 600
and thus longer maintenance intervals
Pst = Stat. pressure difference (Pa)
= Resistance curve Outlet filter SK 3243.200 = old 50 Hz Fan-and-filter unit SK [Link] = new 50 Hz Fan-and-filter unit SK [Link]
= Volumetric flow (m3/h)
Air routing
Intelligent symbiosis of radial and
axial fan technology
Air flow spreads diagonally from the
fan, promoting a more even air distribution in the enclosure
TopTherm fan-and-filter unit
B2 T2 T1
B1
H1
Supply includes: Complete unit ready to install, including filter mat.
B = Width H = Height T = Depth
Air throughput 20 66 m3/h
Model No. SK fan-and-filter unit Model No. SK fan-and-filter unit EMC Rated operating voltage V, Hz Dimensions mm Max. installation depth mm Air throughput, unimpeded air flow Air throughput with outlet filter including standard filter mat Diagonal fan Rated current Power consumption Pre-fuse Noise level Operating temperature range Storage temperature range Colour Protection category to EN 60 529 Model No. SK outlet filter Model No. SK outlet filter EMC Accessories Filter mats Fine filter mats Hose-proof hood Blanking cover Thermostat Temperature indicator Hygrostat Speed control Packs of 5 5 1 1 1 1 1 1 3321.700 3237.080 3237.020 3110.000 3114.200 3118.000 3120.200 3322.700 3238.055 3238.080 3238.020 3237.100 3237.600 230, 50/60 B1/H1 116.5 x 116.5 B2/H2 92 x 92 T1 16 T2 43 20/25 m3/h 1 x SK 3237.200: 15/18 m3/h 20 m3/h 3237.110 115, 50/60 3237.124 24 (DC) 3238.100 3238.600 230, 50/60 148.5 x 148.5 124 x 124 16 58.5 55/66 m3/h 1 x SK 3238.200: 43/50 m3/h 2 x SK 3238.200: 46/56 m3/h DC motor 0.14 A 3W 38 dB (A) Self-starting shaded pole motor 0.12 A/0.11 A 19 W/17 W 46/49 dB (A) 0.24 A/0.23 A 19 W/17 W DC motor 0.28 A 6W 46 dB (A) 55 m3/h 3238.110 115, 50/60 3238.124 24 (DC)
Self-starting shaded pole motor 0.065 A/0.052 A 0.14 A/0.12 A 11 W/9 W 2A 38/43 dB (A) 15C to +55C 30C to +85C RAL 7035
IP 54 standard IP 55 with additional fine filter mat IP 56 with additional fine filter mat and hose-proof hood 3237.200 3237.060 3238.200 3238.060
Special voltages available on request. We reserve the right to make technical modifications.
Rittal TopTherm fan-and-filter unit
H2
TopTherm fan-and-filter unit
Air throughput 105 120 m3/h
Model No. SK fan-and-filter unit Model No. SK fan-and-filter unit EMC Rated operating voltage V, Hz Dimensions mm Max. installation depth mm Air throughput, unimpeded air flow Air throughput with outlet filter including standard filter mat 3239.100 3239.600 230, 50/60 B1/H1 204 x 204 B2/H2 177 x 177 T1 24 T2 90 105/120 m3/h 1 x SK 3239.200: 87/100 m/h 2 x SK 3239.200: 93/108 m/h 1 x SK 3240.200: 98/111 m/h Self-starting shaded pole motor 0.12 A/0.11 A 19 W/17 W 2A 46/49 dB (A) 15C to +55C 30C to +85C RAL 7035 IP 54 standard/IP 55 with additional fine filter mat/IP 56 with additional fine filter mat and hose-proof hood 3239.200 3239.060 5 5 1 1 1 1 1 1 3171.100 3181.100 3239.080 3239.020 3110.000 3114.200 3118.000 3120.200 Packs of 46 dB (A) 0.24 A/0.23 A DC motor 0.28 A 6W 105 m3/h 3239.110 115, 50/60 3239.124 24 (DC)
Diagonal fan Rated current Power consumption Pre-fuse Noise level Operating temperature range Storage temperature range Colour Protection category to EN 60 529 Model No. SK outlet filter Model No. SK outlet filter EMC Accessories Filter mats Fine filter mats Hose-proof hood Blanking cover Thermostat Temperature indicator Hygrostat Speed control
Special voltages available on request. We reserve the right to make technical modifications.
Air throughput 180 250 m3/h
Model No. SK fan-and-filter unit Model No. SK fan-and-filter unit EMC Rated operating voltage V, Hz Dimensions mm Max. installation depth mm Air throughput, unimpeded air flow Air throughput with outlet filter including standard filter mat 3240.100 3240.600 230, 50/60 B1/H1 255 x 255 B2/H2 224 x 224 T1 25 T2 107 180/160 m3/h 1 x SK 3240.200: 138/121 m3/h 2 x SK 3240.200: 165/140 m3/h 1 x SK 3243.200: 165/140 m3/h Self-starting shaded pole motor 0.19 A/0.18 A 33 W/33 W 2A 51/46 dB (A) 30C to +55C 30C to +85C RAL 7035 IP 54 standard/IP 55 with additional fine filter mat/IP 56 with additional fine filter mat and hose-proof hood 3240.200 3240.060 5 5 1 1 1 1 1 1 3172.100 3182.100 3240.080 3240.020 3110.000 3114.200 3118.000 3120.200 3240.060 Packs of 4A 0.38 A/0.36 A DC motor 0.07 A 10 W 2A 51 dB (A) 180 m3/h 230/250 m3/h 1 x SK 3240.200: 183/205 m3/h 2 x SK 3240.200: 203/230 m3/h 1 x SK 3243.200: 203/230 m3/h Self-starting shaded pole motor 0.27 A/0.28 A 42 W/46 W 4A 54/56 dB (A) 0.54 A/0.52 A 43 W/46 W DC motor 0.2 A 25 W 2A 54 dB (A) 230 m3/h 3240.110 115, 50/60 3240.124 24 (DC) 3241.100 3241.600 230, 50/60 3241.110 115, 50/60 3241.124 24 (DC)
Diagonal fan Rated current Power consumption Pre-fuse Noise level Operating temperature range Storage temperature range Colour Protection category to EN 60 529 Model No. SK outlet filter Model No. SK outlet filter EMC Accessories Filter mats Fine filter mats Hose-proof hood Blanking cover Thermostat Temperature indicator Hygrostat Speed control
Special voltages available on request. We reserve the right to make technical modifications.
Rittal TopTherm fan-and-filter unit
TopTherm fan-and-filter unit
Air throughput 550 770 m3/h
Model No. SK fan-and-filter unit Model No. SK fan-and-filter unit EMC Rated operating voltage V, Hz Dimensions mm Max. installation depth mm Air throughput, unimpeded air flow Air throughput with outlet filter including standard filter mat Diagonal fan Rated current Power consumption Pre-fuse Noise level Operating temperature range Storage temperature range Colour Protection category to EN 60 529 Model No. SK outlet filter Model No. SK outlet filter EMC Accessories Filter mats Fine filter mats Hose-proof hood Blanking cover Thermostat Temperature indicator Hygrostat Speed control Packs of 5 5 1 1 1 1 1 1 3173.100 3183.100 3243.080 3243.020 3110.000 3114.200 3118.000 3120.200 3243.100 3243.600 230, 50/60 B1/H1 323 x 323 B2/H2 292 x 292 T1 25 T2 118.5 550/600 m3/h 1 x SK 3243.200: 465/510 m3/h 2 x SK 3243.200: 508/548 m3/h 1~ capacitor motor 0.37 A/0.48 A 71 W/89 W 4A 59/61 dB (A) 30C to +55C 30C to +85C RAL 7035 IP 54 standard IP 55 with additional fine filter mat IP 56 with additional fine filter mat and hose-proof hood 3243.200 3243.060 3243.060 0.75 A/0.80 A 70 W/80 W 6A 0.59 A/0.81 A 109 W/155 W 4A 65/68 dB (A) 1.0 A/1.4 A 110 W/156 W 6A 130.5 700/770 m3/h 1 x SK 3243.200: 544/587 m3/h 2 x SK 3243.200: 614/662 m3/h Rotary current motor 0.22 A/0.24 A 96 W/138 W Motor circuit-breaker 3243.110 115, 50/60 3244.100 3244.600 230, 50/60 3244.110 115, 50/60 3244.140 400/460, 3~, 50/60
Special voltages available on request. We reserve the right to make technical modifications.
Conversion table old/new
Output class Cut-out dimensions (old = new) 24 V 230 V 115 V 400 V EMC fan-and-filter unit, 230 V Outlet filter EMC outlet filter Hose-proof hood Blanking cover Standard filter mat (IP 54) Fine filter mat (IP 55) new old new old new alt new old new old new old new old new old new old new old new old 20/25 m3/h 92 x 92 3237.124 3321.027 3237.100 3321.107 3237.110 3321.117 3237.600 3321.607 3237.200 3321.207 3237.060 3321.267 3237.080 3321.800 3237.020 3321.700 3321.700 55/66 m3/h 124 x 124 3238.124 3322.027 3238.100 3322.107 3238.110 3322.117 3238.600 3322.607 3238.200 3322.207 3238.060 3322.267 3238.080 3322.800 3238.020 3322.700 3322.700 3238.055 105/120 m3/h 177 x 177 3239.124 3323.027 3239.100 3323.107 3239.110 3323.117 3239.600 3323.607 3239.200 3323.207 3239.060 3323.267 3239.080 3323.800 3239.020 3171.100 3171.100 3181.100 3181.100 3172.100 3172.100 3182.100 3182.100 180/160 m3/h 3240.124 3324.027 3240.100 3324.107 3240.110 3324.117 3240.600 3324.607 230/250 m3/h 3241.124 3325.027 3241.100 3325.107 3241.110 3325.117 3241.600 3325.607 550/600 m3/h 3243.100 3326.107 3243.110 3326.117 3243.600 3326.607 700/770 m3/h 3244.100 3327.107 3244.110 3327.117 3244.140 3327.147 3244.600 3327.607 224 x 224 292 x 292
3240.200 3325.207 3240.060 3325.267 3240.080 3324.800 3240.020
3243.200 3326.207 3243.060 3326.267 3243.080 3326.800 3243.020 3173.100 3173.100 3327.700 3183.100 3183.100
Rittal TopTherm fan-and-filter unit
Accessories for fan-and-filter units
Hose-proof hood
For fan-and-filter units/outlet filters. When the hose-proof hood is mounted above the fan-andfilter unit and outlet filter in conjunction with a fine filter mat, a protection category of IP 56 to EN 60 529 is achieved. Material: Stainless steel, silicone Protection category: In conjunction with the fan-and-filter units/outlet filters, NEMA 3R + 12 is met.
For fan-and-filter unit SK 3237. . . . SK 3238. . . . SK 3239. . . . SK 3240. . . ./SK 3241. . . . Dimensions mm 150 x 230 x 40 176 x 245 x 55 233 x 330 x 55 282 x 390 x 85 Model No. SK 3237.080 3238.080 3239.080 3240.080
SK 3243. . . ./SK 3244. . . . 350 x 480 x 110 3243.080 SK 3245. . . .
Blanking cover
If existing mounting cut-outs for fan-and-filter units/outlet filters need to be closed to achieve a higher protection category, the filter mat of the fan-and-filter unit/outlet filter can simply be replaced with a blanking cover; welding or other mechanical modification of the enclosure is not necessary. Material: Plastic Protection category: IP 55
For fan-and-filter unit SK 3237. . . . SK 3238. . . . SK 3239. . . . SK 3240. . . ./SK 3241. . . . SK 3243. . . ./SK 3244. . . . SK 3245. . . .
Model No. SK 3237.020 3238.020 3239.020 3240.020 3243.020
Spare filter mats
Made of chopped-fibre mat with a progressive structure. Temperature-resistant to 100C, self-extinguishing category F1 to DIN 53 438. Dust-laden air side: Open structure. Clean air side: Closed structure. Reliable filtering of virtually all types of dust from a particle size of 10 m. Material: Chemical fibre
For fan-and-filter unit 3237. . . . 3238. . . . 3239. . . . 3240. . . ./3241. . . . 3243. . . ./3244. . . .
Filter class Model No. to DIN EN 779 SK G2 G2 G3 G3 G3 3321.700 3322.700 3171.100 3172.100 3173.100
Fine filter mats
Made of chopped-fibre mat with a progressive structure. Temperature-resistant to 100C, self-extinguishing category F1 to DIN 53 438. Dust-laden air side: Open structure. Clean air side: Closed structure. Reliable filtering of virtually all types of dust from a particle size of 10 m. Material: Chemical fibre
For fan-and-filter unit 3238. . . . 3239. . . . 3240. . . ./3241. . . . 3243. . . ./3244. . . .
Filter class Model No. to DIN EN 779 SK F5 F5 F5 F5 3238.055 3181.100 3182.100 3183.100
Rittal TopTherm fan-and-filter unit
Rittal The System.
Faster better worldwide.
Maximum efficiency, reduced costs, energy savings. Rittals strategy says think in terms of system solutions and provide a system for all applications from power distribution and automation, to building installation, through to the IT infrastructure. And offer your customers unprecedented benefits.
Industrial enclosures Power distribution Electronic packaging System climate control IT systems Service
Rittal GmbH & Co. KG Postfach 1662 D-35726 Herborn Telephone: +49(0)2772 505-0 Telefax: +49(0)2772 505-2319 eMail: info@[Link] [Link]
04/2010 E302