Static Shunt Compensation: Presented by T.S.L.V.Ayyarao

The document discusses static shunt compensation. It describes how shunt compensation can increase transmittable power and control voltage profiles by using shunt reactors to minimize overvoltage under light loads and shunt capacitors to maintain voltage under heavy loads. Midpoint shunt compensation regulates voltage along transmission lines and significantly increases transmittable power, as the midpoint sees the maximum voltage sag. End of line shunt compensation effectively increases voltage stability and regulates terminal voltage. Shunt compensation can also improve transient stability and damp power oscillations on transmission lines.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views13 pages

Static Shunt Compensation: Presented by T.S.L.V.Ayyarao

The document discusses static shunt compensation. It describes how shunt compensation can increase transmittable power and control voltage profiles by using shunt reactors to minimize overvoltage under light loads and shunt capacitors to maintain voltage under heavy loads. Midpoint shunt compensation regulates voltage along transmission lines and significantly increases transmittable power, as the midpoint sees the maximum voltage sag. End of line shunt compensation effectively increases voltage stability and regulates terminal voltage. Shunt compensation can also improve transient stability and damp power oscillations on transmission lines.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd

STATIC SHUNT

COMPENSATION

Presented by

[Link]

OBJECTIVES OF SHUNT
COMPENSATION
Steady-state transmittable power can be increased.
Voltage profile can be controlled.
Shunt connected reactors (fixed or mechanically
switched) are applied to minimize line over voltage
under light load conditions.
Shunt connected capacitors are applied to maintain
voltage levels under heavy load conditions.

MIDPOINT REGULATION FOR LINE


SEGMENTATION

Consider two bus transmission model with ideal


var compensator at the midpoint.

The compensator divides line into 2 parts.


3

MIDPOINT REGULATION FOR LINE


SEGMENTATION

Midpoint var compensator exchange only reactive


power with the line.

Real power is same at each terminal


4

MIDPOINT REGULATION FOR LINE


SEGMENTATION

The transmitted power is

The relation between P, Q and angle

MIDPOINT REGULATION FOR LINE


SEGMENTATION
Midpoint shunt compensation significantly
increase the transmittable power.
Mid point of the transmission line is the best
location for the compensator.
Voltage sag is maximum at the mid point.

END OF LINE VOLTAGE SUPPORT TO


PREVENT VOLTAGE INSTABILITY

Consider a radial Transmission line

END OF LINE VOLTAGE SUPPORT TO


PREVENT VOLTAGE INSTABILITY

END OF LINE VOLTAGE SUPPORT TO


PREVENT VOLTAGE INSTABILITY
Reactive shunt compensation can effectively
increase the voltage stability limit and regulates
the terminal voltage.
End of the line is the best location for
compensator.

IMPROVEMENT OF TRANSIENT
STABILITY

10

IMPROVEMENT OF TRANSIENT
STABILITY

11

IMPROVEMENT OF TRANSIENT
STABILITY

12

POWER OSCILLATION DAMPING

13

You might also like