Frequently used Basic Commands,
To list all sites in BSC,
ZEEI;
To view the status of site,
ZEEI:BCF=BCF_NO;
To view current BTS alarms,
ZEOL; or ZEOL:BTS_NO;
To view current BSC alarms,
ZAHO;
To list history of BTS alarms,
ZEOH:yyyy-mm-dd,00-00-00:BCF=BCF_NO;
To list history of BSC alarms,
ZAHP;
To view ET alarms,
ZAHO:ET,ET_NO;
To view computer units in BSC,
ZUSI:COMP;
To view all blocked TRX,
ZEEL:BL;
To view number of calls in BSC,
ZEEL;
To view signaling links,
ZNEL;
To view BTS and TRX parameters,
ZERO:BTS=BTS_NO;
To view TRX Signaling,
ZERO:BTS=BTS_NO,TRX=TRX_NO;
To view LAP-D Signaling status
ZDTI:::PCM=no;
To give LAP-D reset
ZDTC:LAPD NAME:AD;
ZDTC:LAPD NAME:AL;
ZDTC:LAPD NAME:WO;
ZERS:BTS=no,TRX=no:L;
ZERS:BTS=no,TRX=no:U;
BTS/Sector Reset
ZEQS:BTS=no:L;
ZEQS:BTS=no:U;
Check BTS Parameters
ZEQO:BTS=no:ALL;
Site Reset
ZEFS:BCF no:L;
ZEFS:BCF no:U;
OMU Reset
ZEFR:BCF no:OMU;
DAP Checking
ZESI:ID=BCF no;
To find DAP defined TRX
ZESI:ID=BCF no:TRX;
To see the loop on the ET(PCM)
ZYEF:ET,ETno;
To give reset to the ET
ZUSC:ET,no:BL;
ZUSC:ET,no:WO;
BSC UPGRADE COMMANDS:
To check IP address,
ZQRI:OMU;
To check number of user login,
ZQNS;
To Check Date and Time,
ZDCD;
To check available SW packages in WDU,
ZWQO;
To check current SW packages,
ZWQO:CR;
To check running SW package,
ZWQO:RUN;
To Create a SW Package,
ZWQC:NAME= PACKAGE NAME,DIRE= DIR NAME:FORM=FAILED,CW=NEW;
To delete the SW package,
ZWQD:NAME=PACKAGE NAME:DIRE,PRINTS;
To activate the SW package,
ZWSD:NAME=PACKAGE NAME;
To verify the SW Package,
ZWQB:NAME=<PACKAGE NAME>:FORM=FAILED;
To Add CDs with SW Package,
ZWNA:NAME=PACKAGE NAME:INDEX(ES);
To take fallback,
ZWKS:MODE=FULL,NAME=<FBMMDDYY>,DIR=< FBMMDDYY>;
To Check backup progress status,
ZWKI;
To check phases of FB,
ZWKP:FULL:PHASES;
To Change Status of Default Active Package (FB) to BU,
ZWSR;
To Switch Active Package in Directory,
ZWSS:NAME=<act_pkg_name>; or ZWSS:STAT=<NW,BU>;
To swap the SW package,
ZWSC:NAME=PACKAGE NAME:NAME=PACKAGE NAME;
To view plug-in units of OMU,
ZWTI:P:OMU;
To view License,
ZW7I:LIC,FULL;
To check activated features in license,
ZW7I:FEA,LIM:FSTATE=ON;
To remove license,
ZW7R:license file name;
To view Measurements,
ZTPI:MEASUR;
To start and stop Measurements,
ZTPS; ZTPE;
To check Ring Buffer,
ZIFO:OMU:MEASUR;
To list database,
ZDBC;
To check FTP Access and command authority,
ZIAI:USER ID=user name;
To view feature file,
ZWOS;
To view parameter file,
ZWOI;
To check command authority,
ZIAT;
To check secured FTAM,
ZIOI:ALL;
To check BSC blocked alarms,
ZABO;
To check CGR,
ZCEL:CGR=1&2&3;
To check Lb link,
ZOYI::A;
To check command calendar,
ZICL::COM;
To block command calendar,
ZICB:BL;
To Unblock command calendar,
ZICB:WO;
To check Free Resources,
ZWXI;
To Check Disk Update State,
ZDUQ;
To Prevent Disk Update State,
ZDUP;
To Resume Disk State,
ZDUR;
To List Directories & Files on Winchester Hard drives ,
ZIWX:,:WB,NODEF::%,%;
ZIWX:,:WS,NODEF::%,%;
To View Files under the directory,
ZIWX::WS,NODEF:<dir name>,<subdir name>:%,%;
To create directory on both disks,
ZIWL::WSB,NODEF::<dir name>,FF,2,:; (FF for Default Directory)
To Delete Files on both disks,
ZIWD::WSB:NODEF:<dir name>:<file name>,<file ext>;
To Copy all files from one directory to another,
ZIWY:S:UNIT=OMU,PATH=/dir name/sub dir name,DRIVE=WDU-S;
ZIWY:D:UNIT=OMU,PATH=/dir name/sub dir name,DRIVE=WDU-S;
ZIBC;
BCF UPGRADE COMMANDS:
To check existing software builds for BCF,
ZEWL;
To check the BCF's software status,
ZEWO:< number of BCF>;
To detach the build attached,
ZEWE:< number of BCF>:<build status>;
To attach the software build,
ZEWA:< number of BCF> :<build status>:<build ID>;
To activate the software build.
ZEWV:< number of BCF>:<build status>;
To Swap the BU and NW statuses,
ZEWH:<number of BCF>:ST1=<first status>,ST2=<second status>;
To delete the software build,
ZEWD:<build ID>:<deleting mode>;
To set the initial software build,
ZEWS:<site type>:<build ID>;
To remove the initial software build,
ZEWS:<site type>;
To check the contents of the BCF software builds,
ZEWP:ID=<build ID>;
To check Licence Feature in BTS,
ZEQO:BTS=NUMBER:MIS;
To check BTS blocked alarms,
ZEOE;
To check contents of default BCFPACK directory,
ZIWX:,:WS,NODEF:BCF_PACK,PACK_<x>,:%,%,,:;
To Unzip SW Files,
ZIXX:,WDU-S,-BCF_PACK/PACK_<x>,CX5_0_30.ZIP:,:,WDU-SB,BCF_PACK/PACK_<x>:PATHS=N;
To Create a BCF software build,
ZEWC:<build ID>:MF=<master file name>,EXT=<master file
extension>,SDIR=<subdirectory>;
Functional Units of BSC:
The various functional units of BSC are,
BCSU:
BCSU
MCMU
ET
OMU
TCSM
Plug-in Units of BCSU
PSC6_B
PCU2_D
AS7_C
CP710_A
MBIF_B
To check status of BCSU,
ZUSI:BCSU;
To check alarm in BCSU,
ZAHO:BCSU;
To check software of BCSU,
ZWTI:U:BCSU,0;
To check plug-in units,
ZWTI:P:BCSU;
To Change state of unit,
ZUSC:BCSU,NUMBER:STATE;
To Diagnosis,
ZUDU:BCSU,NUMBER;
MCMU:
Plug-in Units of MCMU
CP710_A
PSC6_B
SWCOP_A
ESB20_A
MBIF_B
To check status of MCMU,
ZUSI:MCMU;
To check alarm in MCMU,
ZAHO:MCMU;
To check plug-in units,
ZWTI:P:MCMU;
To Change state of unit,
ZUSC:MCMU,NUMBER:STATE;
To Diagnosis,
ZUDU:MCMU,NUMBER;
ET:
To check alarms in ET,
ZAHO:ET,NUMBER;
To check ET interface,
ZWUP:ET_NUMBER;
To check status of ET,
ZYEF:ET,NUMBER;
To check plug-in units,
ZWTI:P:ET;
To list external ETS,
ZCEL:CGR=1,FORM=EXT,CONN=BU;
To check software of ET,
ZDPP:OMU:ET,NUMBER:CID;
To Change state of unit,
ZUSC:ET,NUMBER:STATE;
To Diagnosis,
ZUDU:ET,NUMBER;
OMU:
Plug-in units of OMU,
CP710_A
PSC6_B
HWAT_A
WDU-0
WDU-1
FDU
AS7_C
SERO_A
MBIF_B
To check status of OMU,
ZUSI:OMU;
To check alarms in OMU,
ZAHO:OMU;
To check plug-in units,
ZWTI:P:OMU;
To Change state of unit,
ZUSC:OMU:STATE;
To Diagnosis,
ZUDU:OMU;
To check prevention of OMU,
ZDUD;
TCSM:
Plug-in Units of TCSM,
TRCO
TR12
ET
To check status of TCSM,
ZUSI:TCSM;
To find Circuit Group,
ZRCI:SEA=3:CGR=NUMBER:PRINT=4;
To check circuit state and CIC,
ZRCI:SEA=4:ETPCM=256,CRCT=2-4;
To check software of TCSM,
ZDPP:TCSM,NUMBER:CID;
To Change state of unit,
ZUSC:TCSM,NUMBER:STATE;
To Diagnosis,
ZUDU:TCSM,NUMBER;
To check history of Diagnosis ,
ZUDH;
To check the status of current diagnosis,
ZUDQ;