Adiabatic Efficiency
pressure ratio Adiabatic Eff
1
10
2
75
3
83
4
77
5
72
6
68
7
63
90
80
70
60
50
40
30
20
10
0
1
Column D
ROTARY SCREW COMPRESSOR POWER CALCULATION
K
( P2/P1)k-1/k - 1
WR = P1Q x --------- x ---------------------- + WL
K-1
Ea
Where,
P1, P2
Q
K
Ea
----- Pressures
---- Gas flow rates
---- Gas properties
---- Adiabatic efficiency
WL
------ Mechanical losses
WR
----- Power (HP)
ROTARY SCREW COMPRESSOR CAPACITY
ICFM = D3 (L/D) (GR) (RPM) (EV /C)
CENTRIFUGAL COMPRESSOR POWER CALCULATION
V22 - V12 Z2 - Z1
hp = P1Q x[ CP (t2 - t1) + ------------ x ---------------------- + WL
K-1
50,000
778