HW&Frequent Alarm
- HW alarm & procedure
- frequently alarm & procedure
- follow alarm from BE & procedure
HW alarms & Procedure
1.Hardware overview
DU Board: DUL20
Port
RI A-F
TN A
TN B
IDL
LMT A
LMT B
AUX
EC
GPS
Connector
SFP
RJ-45
SFP
HSIO
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
Description
Interface DU-RU (electrical) or DU-RRU (optical)
Gigabit Ethernet (electrical)
Gigabit Ethernet (optical)
Inter-DU link (DU to DU)
Serial port for OSE shell over RS-232
Fast Ethernet for O&M
Auxiliary (Common EC bus)
EC bus (Dedicated EC bus)
Used when the network synchronization source is a
GPS receiver
Hardware Overview
DUS41
Port Connect Description
or
A-F SFP
Radio Interface, 10Gbps/s
Interface DU-RU (electrical) or DU-RRU
(optical).
TN A RJ-45
Transport Network,
Gigabit Ethernet (electrical 1000BASET)
TN B SFP
Transport Network,
Gigabit Ethernet (optical SFP,
1000BASE-X)
TN C SFP
Transport Network,
Gigabit Ethernet (optical SFP,
1000BASE-X)
IDL HSIO
Inter-DU link (DU to DU)
COMPSFP
Coordinated Multi Point communication
(CoMP)
LMT RJ-45
Local Maintenance Terminal, ,
Fast Ethernet for local O&M
EC
RJ-45
EC bus (Dedicated EC bus)
Interface/protocol
Interface: Uu, Protocol: CPRI (proprietary)
C,D,E,F has also support for IDL2
Interface: S1,X2 and Mul
Link1
Interface: S1,X2 and Mul
Link2
Interface: S1,X2 and Mul
NOT USED AT YET
IDL1
NOT USED AT YET
Protocol: IP
Default enodeB IP: 169.254.1.10/24
Communication with SCU(Fan Control)
Hardware Overview
RU
Data 1&2: Gamma data and CPRI
RF A: Feeder connection TX/RX
RF B: Feeder connection RX
RX A I/O, RXB I/O: from crossconnecting RUs
RXA out: for RX antenna sharing
(co-siting)
Hardware Overview
Antenna System
AntennaSubUnit
Hardware Overview
DU-RU Connection
RfPort
AuPort
RiPort
S1
RU 1
S1
RI A
RRU 1
RU 2
RI A
RI B
DU
RI C
RU 3
RI D
RU 4
S2
DU
RI C
RRU 2
RI D
RI E
RI F
S2
RI B
RI E
RU 5
RU 6
S3
RI F
RRU 3
Checking command
1.hget riport remote: Check the interface connection between
DU and RU/RRU.
2. hget rfbranch portref: Check the interface connection between
S3
Hardware Overview
OFFLINE_BKK0016-L21_DCG_K> hget riport remote
140226-20:15:35 OFFLINE_BKK0016-L21_dcg_k 10.0b ERBS_NODE_MODEL_D_1_188_COMPLETE stopfile=/tmp/1604
..
================================================================================================
=================
MO
remoteRiPortRef
================================================================================================
=================
AuxPlugInUnit=RRU-1,RiPort=DATA_1
AuxPlugInUnit=RRU-1,RiPort=DATA_2
Subrack=1,Slot=1,PlugInUnit=1,RiPort=A
AuxPlugInUnit=RRU-2,RiPort=DATA_1
AuxPlugInUnit=RRU-2,RiPort=DATA_2
Subrack=1,Slot=1,PlugInUnit=1,RiPort=B
AuxPlugInUnit=RRU-3,RiPort=DATA_1
AuxPlugInUnit=RRU-3,RiPort=DATA_2
Subrack=1,Slot=1,PlugInUnit=1,RiPort=C
Subrack=1,Slot=1,PlugInUnit=1,RiPort=A AuxPlugInUnit=RRU-1,RiPort=DATA_2
Subrack=1,Slot=1,PlugInUnit=1,RiPort=B AuxPlugInUnit=RRU-2,RiPort=DATA_2
Subrack=1,Slot=1,PlugInUnit=1,RiPort=C AuxPlugInUnit=RRU-3,RiPort=DATA_2
Subrack=1,Slot=1,PlugInUnit=1,RiPort=D
Subrack=1,Slot=1,PlugInUnit=1,RiPort=E
Subrack=1,Slot=1,PlugInUnit=1,RiPort=F
================================================================================================
=================
Total: 12 MOs
OFFLINE_BKK0016-L21_DCG_K> hget rfbranch portref
140226-20:16:57 OFFLINE_BKK0016-L21_dcg_k 10.0b ERBS_NODE_MODEL_D_1_188_COMPLETE stopfile=/tmp/1604
..
================================================================================================
=================
MO
auPortRef
rfPortRef
================================================================================================
=================
AntennaUnitGroup=1,RfBranch=1 [1] = AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1,AuPort=1 AuxPlugInUnit=RRU-1,DeviceGroup=ru,RfPort=A
AntennaUnitGroup=1,RfBranch=2 [1] = AntennaUnitGroup=1,AntennaUnit=1,AntennaSubunit=1,AuPort=2 AuxPlugInUnit=RRU-1,DeviceGroup=ru,RfPort=B
AntennaUnitGroup=2,RfBranch=1 [1] = AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1,AuPort=1 AuxPlugInUnit=RRU-2,DeviceGroup=ru,RfPort=A
AntennaUnitGroup=2,RfBranch=2 [1] = AntennaUnitGroup=2,AntennaUnit=1,AntennaSubunit=1,AuPort=2 AuxPlugInUnit=RRU-2,DeviceGroup=ru,RfPort=B
AntennaUnitGroup=3,RfBranch=1 [1] = AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1,AuPort=1 AuxPlugInUnit=RRU-3,DeviceGroup=ru,RfPort=A
AntennaUnitGroup=3,RfBranch=2 [1] = AntennaUnitGroup=3,AntennaUnit=1,AntennaSubunit=1,AuPort=2 AuxPlugInUnit=RRU-3,DeviceGroup=ru,RfPort=B
================================================================================================
=================
Total: 6 MOs
Added 6 MOs to group: hget_group
HW Alarm
Basic command:
1.Get:
Check the MO details: get xxx(MO name) xxxx(Attribute name)
Show the attribute value of all related MO: get . xxxx(Attribute name)
2.Set:
Change the attribute value of one MO: set xxx(MO name) xxxx(Attribute name)
Change all attribute of related MO: set . xxxx(Attribute name)
3. acl/acc:
List the action of one MO: acl xxx(MO name)
Start the action: acc xxx(MO name) xxxxx(action describtion from command acl)
4.pr & st:
List all related MO: pr XXX(MO name) For example: pr cellrelation (Check all cell
relations)
Check the status of MO: st xxx(MO name)
5.bl/deb
Block or Deblock the MO.
Most command we used when check eNB have the same
structure , just need to change the MO or attribute name.
Microsoft Excel
Attachment is some eNB basic command.
Worksheet
Auto-configuration of Board Not
Possible
specificProblem
eventType
probableCause
Auto-Configuration EQUIPMENT_
of Board Not Possible ALARM
UNAVAILABLE
serviceImp
act
(CellDown,
CellAvailabi
perceive
lity = 0%)
dSeverit Manage (Y = Yes, N serviceDegrade
y
d Object = No)
(Y = Yes, N = No)
WARNIN
G
Slot
Procedure of solving alarm:
1.Verify the board has been inserted into the correct slot
in the subrack and the correct fan has been inserted in
the subrack.
2.If the alarm cause cause is Auto-configuration disabled,
the configuration doesn't match the inserted board , set
the value to true.
3.If the alarm cause is Auto-install for PiuType
failed,Install the load modules for the PIU Type.
4.If the board or fan is not part of the current
configuration, the node must be upgraded with an
Upgrade Package that supports the respective board or
fan. The additionalInfo in the alarm gives more
BatteryMissing
specificProblem
BatteryMissing
serviceImpact
(CellDown,
CellAvailability =
perceived Managed 0%)
serviceDegrade
eventType
probableCause
Severity Object
(Y = Yes, N = No) (Y = Yes, N = No)
PROCESSING_E CONFIGURATION_OR MAJOR
BatteryBa N
N
RROR_ALARM _CUSTOMIZING_ERR
ckup
OR
Procedure of solving alarm:
1.Check if non-exist BFU MO have been created.
2.Restart the BFU.
3.Check the battery cables.
4.Replace the BFU.
5.Replace the battery.
CurrentTooHigh
specificProblem
CurrentTooHigh
serviceImpact
(CellDown,
CellAvailability
perceive
= 0%)
dSeverit Managed (Y = Yes, N =
eventType
probableCause
y
Object
No)
EQUIPMENT_AL EQUIPMENT_MALFU
N
ARM
NCTION
MINOR
RfPort
serviceDegrade
(Y = Yes, N = No)
N
Reason of the alarm:
1. Start-Up of antenna system devices. RETs or RET part of AIR, and
TMAs need high current levels when they are turned on.
2. Short circuit.
3. Other dramatic reduction on the branch equivalent DC resistance
because of malfunction on the antenna system equipment.
4. Too many units connected.
Procedure of solving the alarm:
1.Check if the Rfport connected to RET or TMA is configured correctly.
2. Check for a short circuit in the power supply and antenna system.
3.Check cable connection.Change cables if necessary.
4.If alarm remains,disconnect a RET or TMA.If alarms still
remains,replace the RET, TMA or AIR.
Disconnected
specificProblem
Disconnected
perceivedS Managed
eventType
probableCause
everity
Object
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI MAJOR
Cabinet
M
ON
serviceImpact
(CellDown,
CellAvailability =
0%)
(Y = Yes, N = No)
N
serviceDe
grade
(Y = Yes,
N = No)
N
Disconnected
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI MAJOR
M
ON
EquipmentSup N
portFunction
Disconnected
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI MINOR
M
ON
ExternalNode
Disconnected
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI MAJOR
M
ON
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI MAJOR
M
ON
FanGroup
HwUnit
Disconnected
Disconnected
Actions for Cabinet
1.Connect the smoke detector to the SCU.
2.Restart the SCU to which the smoke detector is connected.
Actions for EquipmentSupportFunction
1. Check that the secondary node Digital Unit (DU) and primary node DU
are connected to the EC bus on correct hubPosition.
2.If the alarm remains, check that secondary node and primary node are
configured properly through the attributes SupportSystemControl
and hubPosition
3.If the alarm remains,restart the secondary node DU.
4.If the alarm remains, restart the primary node DU.
5.Change the cable that connects the secondary or primary node in this
node to the EC bus.
6.Change the EC bus hub or the SHU
Disconnected
Actions for ExternalNode
1.Check that the number of the ExternalNode MO in the primary node is
consistent with the number of secondary nodes installed in the RBS.
2.If the alarm remains, check that the other nodes in the RBS are
configured as secondary nodes. The secondary nodes must have
attribute SupportSystemControl set to FALSE.
3.If the alarm remains, check that the attribute hubPosition on the EcPort
MO (of the ExternalNode MO) in this node has the same value as
attribute hubPosition on the HwUnit MO (of the PlugInUnit MO) in the
corresponding secondary node.
4.Check the cable to EC bus and restart DU or replace cable when needed.
Actions for FanGroup
1.Restart the System Control Unit/Support Part (SCU/SUP).
2.check that attribute climateSystem is correctly configured for this RBS
and that the corresponding correct number of fan groups is installed in
the RBS.
Disconnected
Actions for FanGroup
1.Check that the node is configured properly and that the hardware
unit is present in this RBS node. The correct number of HwUnit
MOs with correct HwUnitType must be configured on the node.
2.Restart the hardware unit and check the cable,hardware is properly
connected and change the faulty unit when necessary.
probableCause
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
Severity Object
No)
(Y = Yes, N = No)
specificProblem
eventType
EnclosureDoorOpen
ENVIRONMENT ENCLOSURE_DOOR_
AL_ALARM
OPEN_M3100
MAJOR
Cabinet
Procedure for solving alarm:
1. Check whether there is any authorized personnel at the site. Follow
the security routines.Close the door.
probableCause
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
Severity Object
No)
(Y = Yes, N = No)
specificProblem
eventType
FanFailure
EQUIPMENT_AL EQUIPMENT_MALFU
ARM
NCTION
MAJOR
FanGroup N
Procedure for solving alarm:
1.Restart the Support Control Unit to see if it has ceased.
2.Lock the SCU,change the fan and unlock the SCU.
specificProblem
GeneralHwError
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
Severity Object
No)
(Y = Yes, N = No)
eventType
probableCause
EQUIPMENT_AL EQUIPMENT_MALFU
ARM
NCTION
MAJOR
HwUnit
Procedure for solving alarm:
1.Restart the faulty board or unit.
2.Change the board or unit.
specificProblem
Gigabit Ethernet Link
Redundancy Fault
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
eventType
probableCause
Severity Object
No)
(Y = Yes, N = No)
EQUIPMENT_AL REPLACEABLE_UNIT_
GigaBitEt
ARM
PROBLEM
WARNING hernet
N
N
Procedure for solving alarm:
1.If the network equipment is incorrectly configured, correct the
configuration, possibly in cooperation with the other maintenance center.
2.Examine the cables between the node and the network equipment to
ensure that they are correctly connected and that they are not faulty.
3.Connect to a different port on the network equipment for the faulty link,
possibly in cooperation with the maintenance center for the network
equipment.
HW Fault
perceivedS Managed
everity
Object
serviceDe
grade
(Y = Yes,
N = No)
specificProblem
eventType
HwFault
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
AntennaNearU
nit
N
HwFault
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
DeviceGroup
HwFault
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
RiPort
probableCause
serviceImpact
(CellDown,
CellAvailability =
0%)
(Y = Yes, N = No)
Alarms occurs when there is a hardware failure in the RET or the
TMA(AntennanearUnit), DU/RU/RRU(DeviceGroup) , or the SFP
module is faulty, disconnected or does not support the required
bitrate.
Actions for AntennaNearUnit
1.Identify the faulty RET or TMA and inspect it visually (check the power
supply, cables, and so on). Replace the cables if necessary.
2.If the alarm remains, restart the faulty RET or TMA.
3.If the alarm remains, replace the RET or TMA.
HW Fault
Actions for DeviceGroup
1.Identify the faulty unit and inspect it visually (check the power
supply, cables, and so on).
2.If the alarm remains, restart the faulty unit. If the faulty unit is a
Digital Unit, restart it with restart rank RESTART_COLDWTEST.
3.Replace the faulty unit.
Actions for RiPort
1.Identify the faulty SFP module connected to the RU or RRU.
2.Replace the faulty SFP module.
LinkFailure
specificProblem
LinkFailure
eventType
probableCause
EQUIPMENT_
ALARM
LINK_FAILURE
serviceImpa
ct
(CellDown,
CellAvailabili
perceive
ty = 0%)
dSeverit Managed (Y = Yes, N serviceDegrade
y
Object
= No)
(Y = Yes, N = No)
MINOR
RiPort
Communication link problem, radio interface connection.Possible
source for the alarm is a faulty DU, cable, or RU/RRU.
The alarm also occurs if the SFP (Small Form-factor Pluggable) module
is faulty, disconnected or does not support the required bit rate. The
additional texts Faulty or Incompatible SFP Module or Missing
SFP Module will then be displayed.
Action for SFP module:
For Faulty or Incompatible SFP Module :Change the faulty SFP
module to the unit generating the alarm.
For Missing SFP Module : Reconnect the missing or disconnected
SFP module to the unit generating the alarm
Action for DU,cable or RU/RRU:
1.Restart the DU and RU/RRU to see if alarm has ceased.
2.If not, check the cable connection between DU and RU/RRU, replace
the cable if necessary.
Loss of Tracking
specificProblem
eventType
Loss of Tracking
EQUIPMENT_AL REPLACEABLE_UNIT_
ARM
PROBLEM
MAJOR
probableCause
serviceImpa
ct
(CellDown,
CellAvailabili
perceive
ty = 0%)
dSeverit Managed (Y = Yes, N serviceDegrade
y
Object
= No)
(Y = Yes, N = No)
Synchroni
Y
zation
Reason of the alarm
1. The system or radio clock cannot track a synchronization
reference because the reference has a very large frequency
deviation. This fault location is Synchronization reference.
2. The system or radio clock cannot track any synchronization
reference as a result of a faulty Timing Unit or the aging of its
oscillator. This fault location is Timing Unit.
Loss of Tracking
Procedure for solving alarm
1. Examine the value of the attribute, syncRefStatus in the MO,
Synchronization, for all defined references.
2. Remove all synchronization references whose state is
LOSS_OF_TRACKING, configure one (or more, if needed) new
synchronization references .
3. Examine the value of the attribute, tuSystemClock in MO,
TimingUnit, for all timing units in the node. Lock the board that is
in state, LOSS_OF_TRACKING, using hard lock.
4. Restart board.
5. Unlock the board, using the instruction, Unlock Board. Reset the
LOSS_OF_TRACKING state, using the action, resetLossOfTracking
in the MO, Synchronization, for all synchronization references.
6. If alarm exsit, replace the board containing the TU.
LossofMains
LossOfMains
perceived Managed
eventType
probableCause
Severity Object
ENVIRONMENTA COMMERCIAL_POWER
L_ALARM
_FAILURE
MAJOR
HwUnit
LossOfMains
ENVIRONMENTA COMMERCIAL_POWER
L_ALARM
_FAILURE
MAJOR
specificProblem
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
PowerSupply N
Reason of the alarm: PSU detects a fault in the incoming power
supply.
Procedure for solving alarm
1. Check the incoming power supply. If the incoming power supply is
absent, contact the incoming power supplier or the next level of
maintenance support.
2. Check the power source fuses.
Change any defective fuse.
No Contact
probableCause
perceived Managed
Severity Object
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
specificProblem
eventType
NoContact
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
AntennaNearU
nit
N
NoContact
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MINOR
AntennaNearU
nit
N
NoContact
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
AuxPlugInUnit Y
Reason of the alarm:
1. AuxPlugInUnit: Connection to resource is lost, or connection is not
established.
The AdditionalText: "(Mixed Mode)" indicates that the RU may be shared
and possible conflict with another RAN needs to be considered.
2. AntennaNearUnit(EQUIPMENT_MALFUNCTION): The alarm originates from
an antenna near unit due to either loss of connection or inability to
establish it.
3. AntennaNearUnit(CONFIGURATION_OR_CUSTOMIZING_ERROR): The alarm
is issued when there is no license for the feature to activate installed
equipment.
No Contact
Actions for AuxPlugInUnit
1. Check that the configuration of the MO RiPort matches
the physical configuration .
2. Identify and lock the faulty unit, replace the faulty unit
(RU, cable, SFP..) and unlock it.
3. escalation.
Actions for AntennaNearUnit
1. Check the cable connection.
2. Restart the RU serving the AnteenaNearUnit.
3. Check ifthe proper licence is installed.
PowerFailure
specificProblem
PowerFailure
perceived
eventType
probableCause
Severity
EQUIPMENT_AL POWER_SUPPLY_FAILU
ARM
RE
MINOR
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
Managed
Object
AuxPlugInUni
t
Y
Reason of the alarm: Incoming power supply failure to RU.
Procedure of solving the alarm:
Loss of mains is the most likely cause for the PowerFailure alarm to
be raised. Therefore, start by checking for external AC problems and
make sure that the power supply switch is turned on.
If the alarm ports of a Remote Radio Unit (RRU) are configured for
power outage supervision, the ExternalAlarm is ceased on affected
alarm ports at RRU power outage. Check the ExternalAlarm
configuration as the ExternalAlarm that preceded PowerFailure might
point to the cause for PowerFailure to be raised.
If alarm still remains, check that the power supply cable to the PDU is
properly inserted and working. Change the cable if necessary.
Identify the RU generating the alarm by inspecting the LED lights on
the front of the unit. The RU with all LED lights off is generating the
alarm. Check that the power supply cable connecting the PDU to the
RU is properly inserted and working. Change the cable if necessary.
Change the PDU. If alarm remains, change the RU/RRU.
RetFailure
probableCause
perceived Managed
Severity Object
specificProblem
eventType
RetFailure
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
RetSubUnit
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
Reason of the alarm:
1.Configuration file problem.
The file needed for the actuator to know how to move that specific antenna
unit is missing.
2.Unable to move antenna due to jam.
Physical problem with the motor or the actuator detected on the RET
subunit tilting the addressed antenna unit.
3.Actuator interference The actuator has been moved by an unknown reason.
Procedure of solving the alarm:
1. check the alarm additional information
2. If it is Configuration file problem, Install a correct antenna configuration file
3. If it is Unable to move antenna due to jam,
- Inspect the antenna and remove any physical obstructions for tilt
- If the alarm remains, identify and change faulty equipment
4. If it is Actuator interference, Set a new value for electricalAntennaTilt to tilt
the antenna to the wanted position
VswrOverThreshold
probableCause
perceived Managed
Severity Object
specificProblem
eventType
VswrOverThreshold
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
RfPort
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
Reason of the alarm:
The alarm is caused by a decrease of return loss below the sensitivity threshold
because of problems in the antenna unit or antenna feeder.
Procedure of solving alarm:
1. Check that the RfPort and RfBranch MOs (for example, parameters
AntennaSupervisionSensitivity, dlAttenuation, and ulAttenuation) are correctly
configured.
-If the configuration is changed, restart the digital unit, as described in Restart
Board.
2. If the alarm remains, restart the radio unit, as described in Restart Board.
Check if the alarm has ceased. It can take up to 30 minutes for the alarm to
reappear.
3. If the alarm remains, check that the feeder is connected properly to the antenna,
and that there is no short circuit in the feeder and antenna system. See Feeder
System Guideline.
4. If the alarm remains, check that there is no water in the feeder, no snow covering
the antenna, or there is no excessive RF signal coming from an external source.
5. If the alarm remains, replace the faulty antenna equipment. If applicable, replace
the Tower Mounted Amplifier (TMA).
Frequent alarm & Procedure
Disk Volume C/D Full
probableCause
perceived Managed
Severity Object
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
specificProblem
eventType
Disk Volume C Full
EQUIPMENT_ALAR
M
DISK_PROBLEM
MAJOR
ManagedElem
ent
N
Disk Volume D Full
EQUIPMENT_ALAR
M
DISK_PROBLEM
MAJOR
PlugInUnit
Reason of the alarm:
Too much redundant data stored on the C/D volume.
Procedure of solving alarm:
1. Determine whether there are old UpgradePackage MOs that should
be deleted. If so, delete them.
2. Investigate whether there are further upgrade package MOs, or
CVs that can be deleted.If so, delete them.
Duplicate IP Address Fault
probableCause
perceived Managed
Severity Object
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
specificProblem
eventType
Duplicate IP Address Fault
COMMUNICATION COMMUNICATION_PROT
S_ALARM
OCOL_ERROR
MAJOR
IpAccessHostEt Y
Duplicate IP Address Fault
COMMUNICATION COMMUNICATION_PROT
S_ALARM
OCOL_ERROR
MAJOR
Ipv6Interface
Reason of the alarm:Configuration fault or communication
protocol error.
Procedure of solving the alarm:
1.For IpAccessHostEt:
a.Set the correct address in the attribute ipAddress in the
IpAccessHostEt MO.
b.Wait for 5 minutes to see if it's ceased
2.For Ipv6Interface:
a.Find the GigaBitEthernet MO by following the reference from the
attribute ethernetRef in the Ipv6Interface MO.
b.Read the attribute macAddressLink1 from the GigaBitEthernet MO.
c.Consult the next level of maintenance support or replace a board.
Emergency Unlock of Software
Licensing
probableCause
perceived Managed
Severity Object
specificProblem
eventType
Emergency Unlock of
Software Licensing
QUALITY_OF_SER ALARM_INDICATION_SIG
VICE_ALARM
NAL
MINOR
Licensing
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
Reason of the alarm:
The alarm is issued when someone activates the Emergency state, using
the action setEmergencyState. The purpose of this Emergency state is
to free the software of all license restrictions in an emergency situation,
so that the capacity of the node is maximized.
Procedure of solving alarm:
1.Investigate whether a new LKF containing a Emergency Unlock Reset key
for the node has been ordered and received from the Ericsson Customer
License Center. If so, continue with the next step. If not, contact the
Ericsson Customer License Center and order a new LKF. Wait for the new
key to be received before proceeding.
2.Install the new LKF into the node from the FTP or SFTP server, using the
operation and maintenance tool that is used for node maintenance. The
MO action is updateLicenseKeyFile.
3.Verify that the alarm ceases.
ExternalAlarm
probableCause
perceived Managed
Severity Object
specificProblem
eventType
ExternalAlarm
UNKNOWN_EVEN EXTERNAL_EQUIPMENT_
T_TYPE
FAILURE
MINOR
AlarmPort
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
Reason of the alarm:
This alarm is issued for external equipment connected to the RBS, or
equipment within the RBS that is defined as external equipment.
Possible alarm triggers are as follows:
1.An external equipment supervision limit is exceeded
2.An external equipment fault condition exists
Alarm severity and actions to take depend on which external
equipment is issuing the alarm. Information in the alarm is based
on the customers configuration of the corresponding MO(1)
AlarmPort.
Procedure of solving the alarm:
1.check that the corresponding MO AlarmPort is configured properly
and consistently with the connected external equipment.
ExternalLinkFailure
specificProblem
eventType
ExternalLinkFailure
EQUIPMENT_ALAR
M
LINK_FAILURE
probableCause
perceived Managed
Severity Object
MINOR
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
ENodeBFunctio
n
N
Reason of the alarm:
The alarm is issued when the X2 link to at least one
neighboring eNodeB is down after four re-setup attempts.
The time between each re-setup attempt is controlled by
the x2RetryTimer.
Procedure of solving the alarm:
1.Check that the corresponding TermPointToEnb MO of the
remote eNB is not in the LOCKED administrative state
2.Check the underlaying transport network between the eNB
and the remote eNB for faults and if such exist, correct
them.
FeatureResourceMissing
perceived Managed
Severity Object
specificProblem
eventType
FeatureResourceMissing
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MINOR
RfPort
FeatureResourceMissing
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MAJOR
SectorEquipme
ntFunction
Y
FeatureResourceMissing
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MAJOR
EUtranCellFDD Y
probableCause
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
Reason of the alarm:
1. For Rfport:The VSWR feature license is missing or the VSWR
feature is not supported in the RU for the antenna port.
2. For SectorEquipmentFunction:The optional feature license stated
in Additional Text is missing and the sector is configured for this
feature
3. For EUtranCellFDD:This alarm is issued during cell unlock if a
feature license is missing or inoperable. If the missing feature
license is 6 Cell Support the alarm is generated when unlocking
the fourth cell.
FeatureResourceMissing
Action for VSWR feature license missing and Rfport: Install
and activate VSWR Antenna Supervision license or turn off
VSWR Supervision.
Action for VSWR feature not supported and Rfport: Replace
the RU or turn off VSWR supervision
Action for SectorEquipmentFunction or EUtranCellFDD:
Install the feature license stated as missing in the
Additional Text. If the Additional Text states the license as
inoperable, the operationalState of the feature is disabled.
Enable the feature.
Gigabit Ethernet Link Fault
specificProblem
eventType
probableCause
Gigabit Ethernet Link Fault
COMMUNICATION
S_ALARM
LOSS_OF_SIGNAL
perceived Managed
Severity Object
MAJOR
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
GigaBitEtherne
t
N
Reason of the alarm:
1. Link Fault.The traffic on the link is disturbed. Link fault,
board fault, Ethernet network fault or configuration fault.
2. Autonegotiation Failed to Meet Minimum Configured
Requirements. The traffic continues at a lower speed than
configured.
Gigabit Ethernet Link Fault
Procedure of solving the alarm:
1. Ensure that the attribute autoNegotiation in the MO
GigaBitEthernet, is aligned on the local and the remote
side. If the alarm ceases, exit this procedure.
2. If the fault is in the remote node and if the alarm ceases
when the fault has been repaired, exit this procedure. If
there is no fault in the remote node, go to Step 3 .
3. Identify the board with the faulty Gigabit Ethernet Link.
4. Lock the faulty board, using the instruction Lock Board. The
Lock type is Hard lock.
5. Restart the faulty board, using the instruction, Restart
Board. The RestartRank is Cold with Test and the
RestartReason is Restart ordered to resolve O&M issues. In
the field RestartInfo, write the name of this alarm.
6. Unlock the board, using the instruction Unlock Board. If the
alarm is not issued again, exit this procedure.
7. If traffic continues at a lower speed than configured, check
the used SFP information.
InconsistentConfiguration
specificProblem
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
eventType
perceived Managed
Severity Object
probableCause
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MAJOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MAJOR
CONFIGURATION_O
service
serviceImpact Degrad
e
(CellDown,
CellAvailability (Y =
Yes, N
= 0%)
= No)
(Y = Yes, N =
No)
AntennaUnit N
DeviceGrou
p
Y
RetSubUnit N
RfPort
RiPort
Y
SectorEquip
mentFunctio
n
Y
MbsfnArea
InconsistentConfiguration
Action for AntennaUnit:
This alarm is raised when the total tilt range of the antenna unit is modified,
there is no Remote Electrical Tilt (RET), and mechanicalAntennaTilt is out
of the total tilt range.
1.Change maximum or minimum total tilt or mechanicalAntennaTilt to get
total tilt within the maximum and minimum total tilt range
Action for DeviceGroup:
The Managed Object configuration of the unit is inconsistent. Either a
program is missing or the configuration is wrong.
1. Consult the next level of maintenance support to retrieve an Upgrade
Package with a correct Managed Object configuration
Action for RetSubUnit:
This alarm is raised when the total tilt range of the AntennaSubunit is modified, causing
the electricalAntennaTilt to be out of the total tilt range.
1. Change maximum or minimum total tilt or electricalAntennaTilt to get total
tilt within the maximum and minimum total tilt range. The
electricalAntennaTilt shall be set to get total tilt (electricalAntennaTilt on
the RetSubUnit MO + mechanicalAntennaTilt on the AntennaUnit MO)
within the maximum and minimum total tilt range.The
electricalAntennaTilt also needs to be set within the ranges of the physical
RET.
InconsistentConfiguration
Action for RfPort:
The alarm is raised when more ports are configured than what
the radio unit supports.
1.Check the software configuration, and configure the correct
number of RET ports.
2.Restart DU.
Action for RiPort:
This alarm is generated in Mixed Mode when the CPRI cable is
not connected according to what is configured in the MIB.
Additional Text: Either the CPRI cable is wrongly connected
or there is a configuration fault (Mixed Mode)
The AdditionalText: "(Mixed Mode)" indicates that the RU
may be shared and possible conflict with another RAN
needs to be considered.
1.Reconnect the CPRI cable.
InconsistentConfiguration
Action for MbsfnArea:
Inconsistent configuration of Mbsfn subframes. A cell is connected to several
Mbsfn areas. The subframes in these Mbsfn areas are overlapped.
1. Lock the MbsfnArea MO.
2.Check the configuration of subframes used by the MbsfnArea in the
attribute commonSFAlloc so that these do not overlap with subframes
used by another activated MbsfnArea.
3.Check the configuration of notificationIndicator so that it is not the same
as for another MbsfnArea that is activated in the same cell.
4.Unlock the MbsfnArea MO.
Action for SectorEquipmentFunction:
This alarm is raised because of, for example, an incorrect configuration of
how the hardware, such as antenna near products, or radio equipment,
are connected.
The alarm might be related to output power licenses. For example,
insufficient output power licenses are installed or there are hardwarerelated output power limitations.
1.Check if the hardware, such as antenna near products or radio equipment,
is correctly configured in the MOM. Modify the configuration if necessary.
2.Check if sufficient output power licenses are installed or if there are any
hardware-related output power limitations.
InconsistentConfiguration
Action for AlarmPort:
In mixed mode configurations, at external alarm port configuration, the
RBS System attempts to setup a physical alarm port on a Remote
Radio Unit (RRU) with a normallyOpen attribute that is different from
the shared client's value.
1.In the LTE node, lock the AlarmPort MO.
2.In the WCDMA node, lock the AlmDevice MO.
3.In the LTE node, set the normallyOpen attribute in the AlarmPort MO.
4.In the LTE node, unlock the AlarmPort MO.
5.In the WCDMA node, set the normallyOpen attribute in the AlmDevice
MO.
6.In the WCDMA node, unlock the AlmDevice MO.
Action for EcPort:
This alarm is raised if the hubposition is empty or not valid. Conflicting
values of hubposition also cause this alarm.
1.Check if the hubposition is given a proper value, that is, the value is
set to the port to which the hardware unit is connected to in the hub.
The hubposition value is not configured for any other EcPort MO.
License Key File Fault
specificProblem
eventType
perceived Managed
Severity Object
probableCause
CONFIGURATION_O
QUALITY_OF_S R_CUSTOMIZING_ER
ERVICE_ALARM ROR
CRITICAL Licensing
service
serviceImpact Degrad
e
(CellDown,
CellAvailability (Y =
Yes, N
= 0%)
= No)
(Y = Yes, N =
No)
Reason of the alarm:
Y
Y
The node has no valid LKF installed.
Procedure of solving the alarm:
1. Confirm that a new LKF has been ordered and received from
the Ericsson Customer License Center.
2. Install the new LKF in the node from the FTP or SFTP server.
Use the action updateLicenseKeyFile on the MO Licensing.
License Key File Fault
NTP Server Reachability
Fault
specificProblem
eventType
NTP Server Reachability
Fault
COMMUNICATION
S_ALARM
UNAVAILABLE
probableCause
perceived Managed
Severity Object
service
serviceImpact Degrad
e
(CellDown,
CellAvailability (Y =
Yes, N
= 0%)
= No)
(Y = Yes, N =
No)
MAJOR
IpSyncRef
N
N
Reason of the alarm:
Communication problems toward NTP server, configuration fault or
HW fault.
Procedure of solving the alarm:
1. Examine the value of the attribute, ntpServerIpAddress, in the
MO, IpSyncRef(or Get . Ntpserveraddress to check the value)
2. Contact the NTP server, using the action, ping on the MO,
IpAccessHostEt
3. If there is no contact with the NTP server, contact the
maintenance center for that NTP server, or contact the
maintenance center for the network. Request them to act on the
fault. There can be a configuration fault in the network.
Password File Fault &Remote IP
Address Unreachable
specificProblem
eventType
perceived Managed
Severity Object
probableCause
CONFIGURATION_O
QUALITY_OF_S R_CUSTOMIZING_ER
ERVICE_ALARM ROR
MINOR
serviceImpac service
Degrad
t
(CellDown, e
CellAvailabilit (Y =
Yes, N
y = 0%)
(Y = Yes, N = = No)
No)
Procedure of solving the alarm:
Security
N
N
1.Access the node via SSH or Telnet.
2.Set a new password, using the shell command passwd. The
alarm automatically ceases when a new password is set
Password File Fault
specificProblem
Remote IP Address
Unreachable
eventType
probableCause
COMMUNICATI
ONS_ALARM
UNAVAILABLE
perceived Managed
Severity Object
Procedure of solving the alarm: MINOR Sctp
Check the IP address connectivity from core side.
serviceImpac service
Degrad
t
(CellDown, e
CellAvailabilit (Y =
Yes, N
y = 0%)
(Y = Yes, N = = No)
No)
N
ResourceConfigurationFailur
e
perceived Managed
Severity Object
specificProblem
eventType
probableCause
ResourceConfigurationF EQUIPMENT_A EQUIPMENT_MALFU
ailure
LARM
NCTION
MINOR
ResourceConfigurationF PROCESSING_ SYSTEM_CALL_UNS
ailure
ERROR_ALARM UCCESSFUL
MAJOR
ResourceConfigurationF PROCESSING_
ailure
ERROR_ALARM TIMEOUT_EXPIRED MAJOR
CONFIGURATION_O
ResourceConfigurationF PROCESSING_ R_CUSTOMIZING_ER
ailure
ERROR_ALARM ROR
MAJOR
ResourceConfigurationF PROCESSING_
ailure
ERROR_ALARM TIMEOUT_EXPIRED MAJOR
serviceImpac service
Degrad
t
(CellDown, e
CellAvailabilit (Y =
Yes, N
y = 0%)
(Y = Yes, N = = No)
No)
RetSubUnit
N
SectorEquipme
ntFunction
Y
SectorEquipme
ntFunction
Y
EUtranCellFDD Y
Y
Y
Action for RetSubUnit:
EUtranCellFDD Y
Y
The alarm is raised when the resource configuration fails,
because the RET tilt is in an unknown position.
Calibrate the RET using the forcedCalibration action of the
RetSubUnit.
ResourceConfigurationFailur
e
Action for SectorEquipmentFunction Systemcall Unsuccessful:
The alarm is raised when the sector is activated and the resource
allocation for the sector fails. This can be caused by a rejected signal
from requested HW.
1. Lock the sector using the SectorEquipmentFunction MO, check this
MO and referenced Rfbranch parameter values.
2. Lock cell/sector and unlock sector/cell again.
Action for SectorEquipmentFunction TIMEOUT_EXPIRED:
This alarm is raised when the sector is activated and the resource
allocation for the sector fails. This can be caused by a signal timeout
from requested HW.
1. Lock the cell using the EUtranCellFDD MO.
2. Unlock the cell.
3. Check that the alarm has ceased.
4. If the alarm remains, restart the RU. See Restart Board.
5. Check that the alarm has ceased.
6. If the alarm remains, restart the node. See Restart Node.
7. Check that the alarm has ceased.
8. If the alarm remains, consult the next level of maintenance support
ResourceConfigurationFailur
e
Action for EUtranCellFDD CONFIGURATION_OR_CUSTOMIZING_ERROR :
1. Check the EUtranCellFDD MO parameter values. Make sure configuraion is
correct.
2. Lock EUtranCellFDD and SectorEquipmentFunction, and unlock them.
Action for EUtranCellFDD TIMEOUT_EXPIRED:
The alarm is raised when activation of resources hangs or when the cell is
activated and the resource allocation for the cell fails. This can be caused by
a missing signal from the requested resource or by disabled (failed) resources
during startup of the node.
1. Lock and Unlock the cell using the EUtranCellFDD MO.Check ifthe alarm has
ceased.
2. If the alarm remains, check that the Digital Unit (DU) and RU is enabled and
unlocked.
4. If the DU is locked, unlock the DU.
5. If the RU is locked, unlock the RU.
6. Lock the cell using the EUtranCellFDD MO.
7. Unlock the cell.
8. If the alarm remains, restart the RU. See Restart Board.
8. Check that the alarm has ceased.
9. If the alarm remains, restart the node. See Restart Node.
10. Check that the alarm has ceased.
11. If the alarm remains, consult the next level of maintenance support.