Hangzhou Steam Turbine Back Pressure

The 1C62 type is a single casing, impulse steam turbine with a reduction gearbox. It uses a full hydraulic governing system and electrical protection devices. The document provides specifications for several multi-stage backpressure turbines developed by Hangzhou Steam Turbine Co., including output, dimensions, steam conditions, and other key parameters. Ratings range from 750KW to 6500KW for models like the B0.75, B1.0, B1.5, and B3T types.

Uploaded by

Navin Kumar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
695 views1 page

Hangzhou Steam Turbine Back Pressure

The 1C62 type is a single casing, impulse steam turbine with a reduction gearbox. It uses a full hydraulic governing system and electrical protection devices. The document provides specifications for several multi-stage backpressure turbines developed by Hangzhou Steam Turbine Co., including output, dimensions, steam conditions, and other key parameters. Ratings range from 750KW to 6500KW for models like the B0.75, B1.0, B1.5, and B3T types.

Uploaded by

Navin Kumar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Hangzhou Steam Turbine Co., Ltd.

(1C62 Type)
The 1C62 type is a single casing, impulse type turbine, with a reduction gearbox.
The turbine uses a full hydraulic governing system and provides the protection devices that have
difference functions, also the electrical governing system is provided in accordance with the customer. The
table lists some multi-stage backpressure turbines that are developed later.
Outline dimenExhaust
sion
Pressure
Steam
Inlet
Rated rate WeiRated
Arrange- Resteam
speed (kg/ ght
Code output
ment marks
flow
(KW) Pre- Tempe (t/h) Rated Variable (r/min) kw.h) (t)
(LHWmm)
values range
ssure -rature
(MPa) (MPa)
(MPa) ( )
Inlet
conditions

Type

B0.75- H254(1)
2.35/0.29
B1.0- H254(1)
2.35/0.29
B0.75- H258(2)
1.27/0.29
B1.5- H255(3)
2.35/0.29
B1.5- H259(2)
2.35/0.49
B1.5- H257(2)
3.43/0.49
B1.0- H260(1)
2.35/0.58
B3T3306
2.35/0.29
B3T3308
3.43/0.29
B3T3307
3.43/0.49
B6T4301
3.43/0.49
B1.0- H254(3)
2.35/0.78

750 2.354 390


1000 2.354 390
750 1.275 340
1500 2.354 390

10.6 0.294
14

0.294

16.2 0.294
20

0.294

1000 2.354 390 26.25 0.49


1500 3.432 435

20

0.49

1000 2.354 390

19.5 0.588

3000 2.354 390

31.5 0.294

3000 3.432 435

27

0.294

3000 3.432 435

32

0.49

0.20.39
0.20.39
0.20.39
0.20.39
0.390.69
0.390.69
0.490.69
0.20.39

6500L 14.1
/1500R
6500L 14
/1500R
6500L 21.5
/1500R
6500L 13.5
/1500R
6500L 17.5
/1500R
6500L 13.5
/1500R
6500L 19.5
/1500R
5600L 14
/3000R
5600L
9
/3000R
0.35- 5600L 10.67
0.69 /3000R

6000 3.432 435


1000 2.354 390

0.78

6500L
/1500R

7 289019201900 Double
layer
Double
7 289019201900
layer
Double
7 289019201900
layer
Double
7 289019201900
layer
Double
7 289019201900
layer
7 289019201900 Double
layer
Double
7 289019201900
layer
Double
9 330023002060
layer
Double
layer
Double
9 330023002060
layer
Double
layer

Note: RCW, view the generator from the turbine. LCCW, view the generator from the turbine.