Deck House - RCP - Lg3 Floor For Checking - 100825
Deck House - RCP - Lg3 Floor For Checking - 100825
034
L
A L
0 0 4 R
W S SYMBOLS FOR WALL TYPES/ FINISHES:
W A L L
T E
01 - M E
FINISH OF WALL INDICATED
BY FIRST ARROW
07-
I
RS-01 2ND FLOOR G.A. TOWER 1, EDSA, BONI AVE., BRGY. MALAMIG, MANDALUYONG CITY
R W-1
REF. PT
- P E
P-1 WALL OR PARTITION
SD
W-1 DESIGNATION
P
W FINISH OF WALL INDICATED
-1,
L E BY SECOND ARROW
P E R I M E T E R
7-G FINISH FLOOR LEVEL/
238
STRUCTURAL FLOOR LEVEL
SYMBOL
T1
L N FINISH FLOOR
LO
FLOOR
FINISH LEVEL
F-1 EL.+1.000M
PROPOSED
PROPOSED SEPTIC TANK CEILING FINISH SCHEDULE
RAIN WATER STORAGE TANK
CAP.=3,000 US GALS(MORE OR LESS) CODE DESCRIPTION
TOTAL TANK DEPTH= 3 MTS.
12.5mm GYPSUM BOARD BY USG BORAL
L ON
LI A N D S C A P E
A L RI
CT C-01 PAINTED FINISH, FLAT WHITE. WITH
W RE
ST SEE DETAILS
R OF
COMPLETE FRAMING AND BRACKETING.
T E NE
I M E LI L 4.5mm FIBER CEMENT BOARD BY
R HARDIEFLEX FOR INTERIOR.
3 P E L C-02
W A L L
ARCHITECT/ ENGINEER
P E R I M E T E R
SEE DETAILS
1.20
GL GL GL GL GL GL GL GL GL GL
1.00 APPLY CLEAR COAT SEALER, MATTE FINISH.
X USE PVC DRIP MOULD AT CONCRETE CANOPY.
OPEN RETAINING WALL
X
LOUNGE H FM
SLOPE
INFINITY WALL
H
PROJECT TITLE
LOCATION : LOT 12387, MARIA LUISA ESTATES, BRGY. BANILAD, CEBU CITY
FM
EXTERIOR CANOPY ON ELASTOMERIC PAINTED FINISH.
G GL
1.00
VERIFY COLOR
PROPOSED 1-STOREY RESIDENCE WITH
3 LOWER GROUND LEVELS RESIDENCE
E
H FM G MAIN STAIRS CEILING ON GRAPHITE GRAY STEEL
P
GL
PLATE, WITH COMPLETE FRAMING AND HANGERS.
A
LINE OF LG1 ABOVE C-07
1.20
C
SEE STAIR DETAILS.
S
G
D
H
GL 9mm FIBER CEMENT BOARD BY
FM
1.32 M DEPTH 1.52 M DEPTH
N
HARDIEFLEX FOR EXTERIOR
LINE OF LG1 ABOVE
P O O L C-08
A
1.20
L
G GL COMPLETE FRAMING AND BRACKETING.
H FM H FM H FM H FM
SLOPE 9mm FICEM BOARD ON
CEMENT STUCCO FINISH.
C-09
1.20
G GL
F FM F FM F FM F FM F FM F FM F FM
1.20 1.20
1.00 1.00
STAIR 05 G G G G G G G
J GL
REFER BLOW-UP DETAILS GL GL GL GL GL GL GL
LEGEND:
LOUNGE SYMBOL DESCRIPTION
F FM F FM F FM F FM F FM F FM F FM F FM
CHB LOW WALL
1.20 1.20 1.20 1.20 Surface Mounted, Big Ceiling Lamps by Vibia
J GL LINE OF LG2 ABOVE
*Refer Manufacturer's Specs
E
CM CM CM CM CM
P
J GL
Brand: Haiku by Philippine Geo Green Inc. or
GL
F FM
A
Approved Equivalent
1.60
1.00
C
*Refer Manufacturer's Specs
S
DOWN TO SWIMMING POOL O CM
D
J GL A SD C C C D SD D D
GL
Lumi Lite Led Linear Grille Light White Fixture
U C-09
8.10
N
12 x 2w Size: L338xW40xH55mm Warm White
1.00
CM CM CM CM CM CM CM
+4.25 m 3000K
4.00 DETAILS
A
DIN
3.50I N G
LINE OF DROP CEILING ABOVE
SEE BLOW-UP
N
L
E
1.60
1.60
RESTRICTION
J GL +4.25 m O
CM GL
4 x 2w Size: L122xW40xH55mm Warm White
2.00 2.00
A
3000K
RESTRICTION
C
STAIR 01 A C
B AC R C D D D
S
CM CM
J 4.00CM CM CM
4.60 CM CM
GL 2 x 2w Size: L60xW40xH55mm Warm White
GL UP TO LG2
N
LINEAR
SEE CABINET DETAILS
LINEAR
SEE CABINET DETAILS
3000K
S1-ABC CAB
A
01
S1-DEF SEE BLOW-UP DETAILS
E GRILL AREA
2
L
02
S1-JKL E Lumi Lite Led Downlight Pull Out Type
J GL
M 03 S1-MNO Directional 360 1 X 7w Led White Fixture
S3W-U
OF
LINE
04
A WATER FILTER /
Q R R S1-V
OWNER
CM CM
POWDER RM / SHOWER
05 CM CM TREATMENT SYSTEM
MIRROR WALL (refer details)
COUNTERTOP BASIN
BY SPECIALTY
LINE
CM
CM BY SPECIALTY contractor's proposal. SLOPE TO DRAIN
0.80
FD
+2.65 m +2.70 m
Lumi Lite 100w LED Flood Light Model:
urinal
J R
R
3.0HP FTKC
GL CM LLT-FL1MW100w
10 Q CM
E
990
11 27 LINEAR
P
FD
shower
J GL
13 25 LLT-FL1MW50w
SLIDING DOOR
SLOPE TO DRAIN
CM AREA: 25.75 SQ.M.
2.70
S
U
14 24
D
( 3-4 PAX. )
16 22 Lumi Lite 10w Led Spike Up Lighter
A
17 21
3 18
LINEAR
SEE RAILING DETAILS
20
19
Lumi Lite Inground Light 3w Big Size 3000k Pond
J GL Light (Driver Not Included)
T5
C-10 Lumi Lite T5 Led Square Seamless Connection
J GL S3W-U 900mm 18w
which they are made is executed or not, it shall be unlawful for any person,
5
W A L L
528
042
P E R I M E T E R
PH0.3
AC Indoor Unit, Wall Mounted
SHEET CONTENT
2
P R O P E R T Y L I N E 1
P R O P E R T Y L I N E
REVISION/S
LOWER GROUND 3
LOWER GROUND 3 FLOOR PLAN
CORP.
1
A-08
1 REFLECTED
SCALE
CEILING PLAN 1:50 M.T.S.
A-20B SCALE 1:50 M
SHEET NO.
A-20B