0% found this document useful (0 votes)
2K views1 page

Mazak RS-232

Serial Cable Pin-Out For Mazak CNC Machine Tools NOTE: This Document does not apply to CMT-IO computer computer. In practice, RS-CS and DR-CD-ER do not seem to need jumpers on computer side.

Uploaded by

Dany Escobar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views1 page

Mazak RS-232

Serial Cable Pin-Out For Mazak CNC Machine Tools NOTE: This Document does not apply to CMT-IO computer computer. In practice, RS-CS and DR-CD-ER do not seem to need jumpers on computer side.

Uploaded by

Dany Escobar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Serial Cable Pin-Out For Mazak CNC Machine Tools

NOTE: This Document does NOT apply to CMT-IO

CNC

Computer

CNC

Computer

Note: in practice, RS-CS & DR-CD-ER do not seem to need jumpers on computer side.

Serial Communication Settings Mazak Fusion 640 Series


4800 bps 8 Data Bits 2 Stop Bits No Parity DC Code Handshake ISO Data

Serial Communication Settings Microsoft Windows based PC


4800 bps 7 Data Bits 2 Stop Bits EVEN Parity XOn-XOff Handshake ASCII Data