FIRE RESISTANT CABLES
2
2
N2XY
1
x
(1.5-800)
mm
0.6/1
N2XY 1 x (1.5-800) mm 0.6/1
kV
kV
Cu / Mica / XLPE / PVC
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Nom.
Cross
Section
Area
Overall
Diameter
Cable
Weight
approx.
approx.
mm
mm
kg/km
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
6.8
7.2
7.8
8.4
9.4
10.4
12.2
13.3
15.0
16.9
18.9
21.0
23.0
25.5
29.0
31.5
35.0
39.5
44.0
49.0
58
72
92
115
162
222
332
427
576
782
1,030
1,274
1,550
1,951
2,543
3,080
3,935
5,025
6,526
8,181
Application :
For wiring of fire resistant safety circuits, such
as fire alarm system, emergency lighting and
power, public address and emergency voice
communication systems in highrise building,
control and instrumentation services in industrial,
commercial and residential complexes.
Special Features on Request
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Nylon Coated
Copper Conductor
Mica Tape
XLPE Insulation
PVC Sheath
Note :
Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 800 sqmm supplied in non compacted circular stranded (rm) or compacted
circular stranded (cm) conductor shape
Standard Packing
1.5 - 10 sqmm supplied in coil @ 100 m
16 - 400 sqmm supplied in wooden drum @ 1000 m
500 - 800 sqmm supplied in wooden drum on available length
Length Tolerance per drum 2%
Conductor
Inductance
Current - Carrying Capacity at 30 C *
Trefoil
formation
Flat
formation
in air
in ground
in air
in ground
Short
circuit current
at
1 sec
Max.
(/km)
(mH/km)
(mH/km)
Max.
(A)
Max.
(A)
Max.
(A)
Max.
(A)
Max.
(kA)
15.429
9.449
5.878
3.927
2.333
1.466
0.927
0.668
0.494
0.342
0.247
0.196
0.160
0.128
0.099
0.080
0.064
0.052
0.043
0.036
0.478
0.441
0.409
0.387
0.356
0.333
0.317
0.303
0.290
0.280
0.272
0.268
0.267
0.265
0.260
0.255
0.254
0.251
0.247
0.244
0.524
0.487
0.455
0.433
0.402
0.379
0.363
0.349
0.336
0.326
0.318
0.314
0.313
0.311
0.306
0.301
0.300
0.297
0.293
0.291
25
34
45
57
78
104
141
173
213
271
335
392
451
526
630
728
848
985
1141
1295
33
43
56
69
92
118
152
182
216
265
316
359
403
455
527
593
671
757
849
937
26
35
46
58
80
107
145
178
220
279
346
404
466
543
650
751
875
1018
1179
1339
33
43
55
68
91
117
151
180
214
261
312
355
397
449
519
584
660
744
834
921
0.21
0.36
0.57
0.86
1.43
2.29
3.58
5.01
7.15
10.01
13.59
17.16
21.45
26.46
34.32
42.90
57.20
71.50
90.09
114.40
Nom.
Cross
Sect.
DC
Resistance
at 20C
AC
Resistance
at 90C
(mm)
Max.
(/km)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
[Link]
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
157CH-01 Rev. 2.0 / 2009
Electrical Data
FIRE RESISTANT CABLES
2
2
N2XY
2
x
(1.5-300)
mm
0.6/1
N2XY 2 x (1.5-300) mm 0.6/1
kV
kV
Cu / Mica / XLPE / PVC
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Nom.
Cross
Section
Area
Overall
Diameter
Cable
Weight
approx.
approx.
mm
mm
kg/km
1.5
14.5
255
2.5
15.5
301
16.6
363
18.0
441
10
19.9
582
16
22.0
758
25
25.0
1,050
35
27.5
1,324
50
30.0
1,626
70
34.5
2,248
95
38.0
2,873
120
41.5
3,486
150
46.5
4,337
185
51.0
5,256
240
56.5
6,644
300
62.5
8,207
Application :
For wiring of fire resistant safety circuits, such
as fire alarm system, emergency lighting and
power, public address and emergency voice
communication systems in highrise building,
control and instrumentation services in industrial,
commercial and residential complexes.
Special Features on Request
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Nylon Coated
Copper Conductor
Mica Tape
XLPE Insulation
PVC Inner Sheath
PVC Sheath
Note :
Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
1.5 - 120 sqmm supplied in wooden drum @ 1000 m
150 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum 2%
Electrical Data
Inductance
DC
AC
Cross
Resistance
Resistance
Sect.
at 20C
at 90C
Max.
Max.
(mm)
(/km)
(/km)
(mH/km)
1.5
12.1
15.429
2.5
7.41
9.449
4.61
Current - Carrying
Capacity
at 30C *
Short
circuit current
at
1 sec
in air
in ground
Max.
Max.
(A)
(A)
Max.
(kA)
0.315
29
34
0.21
0.293
38
44
0.36
5.878
0.275
50
58
0.57
3.08
3.927
0.263
64
73
0.86
10
1.83
2.334
0.248
88
98
1.43
16
1.15
1.466
0.238
116
128
2.29
25
0.727
0.927
0.240
154
165
3.58
35
0.524
0.668
0.233
190
199
5.01
50
0.387
0.494
0.232
230
236
7.15
70
0.268
0.342
0.229
292
292
10.01
95
0.193
0.247
0.224
356
348
13.59
120
0.153
0.196
0.223
414
397
17.16
150
0.124
0.160
0.224
474
445
21.45
185
0.0991
0.128
0.225
544
502
26.46
240
0.0754
0.099
0.223
644
582
34.32
300
0.0601
0.080
0.221
737
654
42.90
[Link]
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
157CH-02 Rev. 2.0 / 2009
Conductor
Nom.
FIRE RESISTANT CABLES
N2XY
(1.5-300)
mm
0.6/1
N2XY 33xx(1.5-300)
mm
0.6/1
kV
kV
Cu / Mica / XLPE / PVC
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Nom.
Cross
Section
Area
Overall
Diameter
Cable
Weight
approx.
approx.
mm
mm
kg/km
1.5
15.2
282
2.5
16.2
338
17.4
415
18.9
511
10
21.0
689
16
23.5
915
25
26.5
1,289
35
29.0
1,646
50
32.0
2,039
70
37.0
2,828
95
40.5
3,682
120
44.5
4,496
150
50.0
5,575
185
54.5
6,814
240
61.0
8,794
300
66.5
10,755
Application :
For wiring of fire resistant safety circuits, such
as fire alarm system, emergency lighting and
power, public address and emergency voice
communication systems in highrise building,
control and instrumentation services in industrial,
commercial and residential complexes.
Copper Conductor
Mica Tape
XLPE Insulation
PVC Inner Sheath
Special Features on Request
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Nylon Coated
PVC Sheath
Note :
Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
1.5 - 95 sqmm supplied in wooden drum @ 1000 m
120 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum 2%
Electrical Data
Inductance
DC
AC
Cross
Resistance
Resistance
Sect.
at 20C
at 90C
Max.
Max.
(mm)
(/km)
(/km)
(mH/km)
1.5
12.1
15.429
2.5
7.41
9.449
4.61
Current - Carrying
Capacity
at 30C *
Short
circuit current
at
1 sec
in air
in ground
Max.
Max.
(A)
(A)
Max.
(kA)
0.315
21
28
0.21
0.293
32
37
0.36
5.878
0.275
43
49
0.57
3.08
3.927
0.263
54
61
0.86
10
1.83
2.334
0.248
74
83
1.43
16
1.15
1.467
0.238
99
107
2.29
25
0.727
0.927
0.240
131
139
3.58
35
0.524
0.669
0.233
162
167
5.01
50
0.387
0.494
0.232
200
203
7.15
70
0.268
0.343
0.229
252
248
10.01
95
0.193
0.247
0.224
309
298
13.59
120
0.153
0.197
0.223
359
339
17.16
150
0.124
0.160
0.224
411
379
21.45
185
0.0991
0.129
0.225
475
430
26.46
240
0.0754
0.099
0.223
562
497
34.32
300
0.0601
0.081
0.221
645
560
42.90
[Link]
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
157CH-03 Rev. 2.0 / 2009
Conductor
Nom.
FIRE RESISTANT CABLES
2
2
N2XY
4
x
(1.5-300)
mm
0.6/1
N2XY 4 x (1.5-300) mm 0.6/1
kV
kV
Cu / Mica / XLPE / PVC
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Nom.
Cross
Section
Area
Overall
Diameter
Cable
Weight
approx.
approx.
mm
mm
kg/km
1.5
16.3
323
2.5
17.5
392
18.8
488
20.5
606
10
23.0
839
16
25.5
1,125
25
29.0
1,602
35
32.0
2,073
50
36.0
2,628
70
41.0
3,586
95
44.5
4,700
120
50.0
5,848
150
55.5
7,148
185
61.0
8,849
240
67.5
11,313
300
74.0
13,867
Application :
For wiring of fire resistant safety circuits, such
as fire alarm system, emergency lighting and
power, public address and emergency voice
communication systems in highrise building,
control and instrumentation services in industrial,
commercial and residential complexes.
Copper Conductor
Mica Tape
XLPE Insulation
PVC Inner Sheath
Special Features on Request
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Nylon Coated
PVC Sheath
Note :
Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
1.5 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum 2%
Electrical Data
Inductance
DC
AC
Cross
Resistance
Resistance
Sect.
at 20C
at 90C
Max.
Max.
(mm)
(/km)
(/km)
(mH/km)
1.5
12.1
15.429
2.5
7.41
9.449
4.61
Current - Carrying
Capacity
at 30C *
Short
circuit current
at
1 sec
in air
in ground
Max.
Max.
(A)
(A)
Max.
(kA)
0.315
27
31
0.21
0.293
35
41
0.36
5.878
0.275
47
53
0.57
3.08
3.927
0.263
59
67
0.86
10
1.83
2.334
0.248
81
89
1.43
16
1.15
1.467
0.238
108
116
2.29
25
0.727
0.927
0.240
146
151
3.58
35
0.524
0.669
0.233
180
181
5.01
50
0.387
0.494
0.232
212
208
7.15
70
0.268
0.343
0.229
265
254
10.01
95
0.193
0.247
0.224
327
305
13.59
120
0.153
0.197
0.223
379
347
17.16
150
0.124
0.160
0.224
442
392
21.45
185
0.0991
0.129
0.225
504
441
26.46
240
0.0754
0.099
0.223
597
511
34.32
300
0.0601
0.081
0.221
685
576
42.90
[Link]
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
157CH-04 Rev. 2.0 / 2009
Conductor
Nom.