Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
A.3 Ordering information
A.3.1 Rosemount 3051S MultiVariable transmitter
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Transmitter Type
3051SMV Scalable MultiVariable Transmitter
Performance Class
Standard Standard
3051SMV MultiVariable SuperModule, Measurement Types 1 and 2
3
(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty
5 Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 5-year stability
3051SMV Single Variable SuperModule, Measurement Types 3 and 4
1
(2)
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty
2 Classic: 0.055% span DP accuracy, 100:1 rangedown, 5-year stability
3
(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty
MultiVariable Type
Standard Standard
M MultiVariable Measurement with Fully Compensated Mass and Energy Flow
P MultiVariable Measurement with Direct Process Variable Output
Measurement Type
Standard Standard
1 Differential Pressure, Static Pressure, and Temperature
2 Differential Pressure and Static Pressure
3 Differential Pressure and Temperature
4 Differential Pressure
Differential Pressure Range
Standard Standard
0
(2)(3)
-3 to 3 inH
2
O (-7,47 to 7,47 mbar)
1 -25 to 25 inH
2
O (-62,2 to 62,2 mbar)
2 -250 to 250 inH
2
O (-623 to 623 mbar)
3 -1000 to 1000 inH
2
O (-2,5 to 2,5 bar)
4 -300 to 300 psi (-20,7 to 20,7 bar)
5 -2000 to 2000 psi (-137,9 to 137,9 bar)
Static Pressure Type
Standard Standard
N
(4)
None
A Absolute
G Gage
Static Pressure Range Absolute Gage
Standard Standard
N
(4)
None
3 Range 3 0.5 to 800 psia (0,03 to 55,2 bar) -14.2 to 800 psig (-0,98 to 55,2 bar)
4
(5)
Range 4 0.5 to 3626 psia (0,03 to 250 bar) -14.2 to 3626 psig (-0,98 to 250 bar)
28
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Temperature Input
Standard Standard
N
(6)
None
R
(7)
RTD Input (Type Pt 100, -328 to 1562 F (-200 to 850 C))
Isolating Diaphragm
Standard Standard
2
(8)
316L SST
3
(8)
Alloy C-276
Expanded
5
(9)
Tantalum
7 Gold-Plated 316L SST
Process Connection Size
Material Type
Flange
Material Drain Vent Bolting
Standard Standard
000 None
A11
(10)
Assemble to Rosemount 305/306 Integral Manifold
A12
(10)
Assemble to Rosemount 304 or AMF Manifold with SST Traditional Flange
B11
(10)(11)
Assemble to one Rosemount 1199 Seal
B12
(10)(11)
Assemble to two Rosemount 1199 Seals
C11
(10)
Assemble to Rosemount 405 Primary Element
D11
(10)
Assemble to Rosemount 1195 Integral Orifice and Rosemount 305 Integral Manifold
EA2
(10)
Assemble to Rosemount Annubar Primary
Element with Coplanar flange
SST 316 SST
EA3
(10)
Assemble to Rosemount Annubar Primary
Element with Coplanar flange
Cast C-276 Alloy C-276
EA5
(10)
Assemble to Rosemount Annubar Primary
Element with Coplanar flange
SST Alloy C-276
E11 Coplanar flange
1
/418 NPT Carbon Steel 316 SST
E12 Coplanar flange
1
/418 NPT SST 316 SST
E13
(8)
Coplanar flange
1
/418 NPT Cast C-276 Alloy C-276
E14 Coplanar flange
1
/418 NPT Cast Alloy 400 Alloy 400/K-500
E15
(8)
Coplanar flange
1
/418 NPT SST Alloy C-276
E16
(8)
Coplanar flange
1
/418 NPT Carbon Steel Alloy C-276
E21 Coplanar flange RC
1
/4 Carbon Steel 316 SST
E22 Coplanar flange RC
1
/4 SST 316 SST
E23
(8)
Coplanar flange RC
1
/4 Cast C-276 Alloy C-276
E24 Coplanar flange RC
1
/4 Cast Alloy 400 Alloy 400/K-500
E25
(8)
Coplanar flange RC
1
/4 SST Alloy C-276
E26
(8)
Coplanar flange RC
1
/4 Carbon Steel Alloy C-276
F12 Traditional flange
1
/418 NPT SST 316 SST
F13
(8)
Traditional flange
1
/418 NPT Cast C-276 Alloy C-276
F14 Traditional flange
1
/418 NPT Cast Alloy 400 Alloy 400/K-500
F15
(8)
Traditional flange
1
/418 NPT SST Alloy C-276
F22 Traditional flange RC
1
/4 SST 316 SST
F23
(8)
Traditional flange RC
1
/4 Cast C-276 Alloy C-276
F24 Traditional flange RC
1
/4 Cast Alloy 400 Alloy 400/K-500
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
29
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Process Connection Size
Material Type
Flange
Material Drain Vent Bolting
F25
(8)
Traditional flange RC
1
/4 SST Alloy C-276
F52
DIN-compliant
traditional flange
1
/418 NPT SST 316 SST
7
/16-in. bolting
G11 Vertical mount level
flange
2-in. ANSI class 150 SST
G12 Vertical mount level
flange
2-in. ANSI class 300 SST
G14
(8)
Vertical mount level
flange
2-in. ANSI class 150 Cast C-276
G15
(8)
Vertical mount level
flange
2-in. ANSI class 300 Cast C-276
G21 Vertical mount level
flange
3-in. ANSI class 150 SST
G22 Vertical mount level
flange
3-in. ANSI class 300 SST
G31 Vertical mount level
flange
DIN- DN 50 PN 40 SST
Expanded
EB6 Assemble to Primary Element with Manifold and Coplanar Flange, CS, Alloy C-276
F32 Bottom vent traditional
flange
1
/418 NPT SST 316 SST
F42 Bottom vent traditional
flange
RC
1
/4 SST 316 SST
F62 DIN-compliant
traditional flange
1
/418 NPT SST 316 SST M10 bolting
F72 DIN-compliant
traditional flange
1
/418 NPT SST 316 SST M12 bolting
G41 Vertical mount level
flange
DIN- DN 80 PN 40 SST
Transmitter Output
Standard Standard
A 420 mA with digital signal based on HART protocol
Housing Style Material Conduit Entry Size
Standard Standard
1A PlantWeb housing Aluminum
1
/214 NPT
1B PlantWeb housing Aluminum M20 x 1.5
1J PlantWeb housing SST
1
/214 NPT
1K PlantWeb housing SST M20 x 1.5
Expanded
1C PlantWeb housing Aluminum G
1
/2
1L PlantWeb housing SST G
1
/2
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
30
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Options (Include with selected model number)
RTD Cable (RTD Sensor must be ordered separately)
Standard Standard
C12 RTD Input with 12 ft. (3.66 m) of Shielded Cable
C13 RTD Input with 24 ft. (7.32 m) of Shielded Cable
C14 RTD Input with 75 ft. (22.86 m) of Shielded Cable
C20
(12)
RTD Input with 27 in. (69 cm) of Armored Shielded Cable
C21 RTD Input with 4 ft. (1.22 m) of Armored Shielded Cable
C22 RTD Input with 12 ft. (3.66 m) of Armored Shielded Cable
C23 RTD Input with 24 ft. (7.32 m) of Armored Shielded Cable
C24 RTD Input with 75 ft. (22.86 m) of Armored Shielded Cable
C30
(12)
RTD Input with 25 in. (64 cm) of ATEX/IECEx Flameproof Cable
C32 RTD Input with 12 ft. (3.66 m) of ATEX/IECEx Flameproof Cable
C33 RTD Input with 24 ft. (7.32 m) of ATEX/IECEx Flameproof Cable
C34 RTD Input with 75 ft. (22.86 m) of ATEX/IECEx Flameproof Cable
C40
(12)
RTD Input with 34 in. (86.36 cm) Shielded Cable and 24 in. (60.96 cm) FM Approved Coupling Flex
C41
(12)
RTD Input with 40 in. (101.60 cm) Shielded Cable and 30 in. (76.20 cm) FM Approved Coupling Flex
Mounting Brackets
(13)
Standard Standard
B4 Coplanar flange bracket, all SST, 2-in. pipe and panel
B1 Traditional flange bracket, Carbon Steel, 2-in. pipe
B2 Traditional flange bracket, Carbon Steel, panel
B3 Traditional flange flat bracket, Carbon Steel, 2-in. pipe
B7 Traditional flange bracket, B1 with SST bolts
B8 Traditional flange bracket, B2 with SST bolts
B9 Traditional flange bracket, B3 with SST bolts
BA Traditional flange bracket, B1, all SST
BC Traditional flange bracket, B3, all SST
Software Configuration
Standard Standard
C1 Custom software configuration
Note: A Configuration Data Sheet must be completed, see document number 00806-0100-4803.
C2 Custom flow configuration
Note: A Custom Fluid Data Sheet must be completed, see document number 00806-0200-4803.
C4 NAMUR alarm and saturation levels, high alarm
C5 NAMUR alarm and saturation levels, low alarm
C6 Custom alarm and saturation signal levels, high alarm
C7 Custom alarm and saturation signal levels, low alarm
C8 Low alarm (standard Rosemount alarm and saturation levels)
Flange Adapter
Standard Standard
D2
(13) 1
/2-14 NPT flange adapter
Expanded
D9
(13)
RC
1
/2 SST flange adapter
Ground Screw
Standard Standard
D4 External ground screw assembly
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
31
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Drain/Vent Valve
Standard Standard
D5
(13)
Delete transmitter drain/vent valves (install plugs)
Expanded
D7
(13)
Coplanar flange without drain/vent ports
Conduit Plug
Standard Standard
DO
(14)
316 SST Conduit Plug
Product Certifications
Standard Standard
E1 ATEX Flameproof
I1 ATEX Intrinsic Safety
N1 ATEX Type n
ND ATEX Dust
K1 ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
E4 TIIS Flameproof
E5 FM Explosion-proof, Dust Ignition-proof
I5 FM Intrinsically Safe, Division 2
K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
E6
(15)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6 CSA Intrinsically Safe
K6
(15)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
E7 IECEx Flameproof, Dust Ignition-proof
I7 IECEx Intrinsic Safety
N7 IECEx Type n
K7 IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of E7, I7, and N7)
E2 INMETRO Flameproof
I2 INMETRO Intrinsic Safety
E3 China Flameproof
I3 China Intrinsic Safety
KA
(15)(16)
ATEX and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E1, E6, I1, and I6)
KB
(15)(16)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, and
I6)
KC FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
KD
(15)(16)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5, I6, and I1)
DW
(17)
NSF Drinking Water Certification
Alternate Materials of Construction
Standard Standard
L1 Inert sensor fill fluid (Differential and Gage sensors only) Note: Silicone fill fluid is standard.
L2 Graphite-filled PTFE O-ring
L4
(13)
Austenitic 316 SST bolts
L5
(8)(13)
ASTM A193, Grade B7M bolts
L6
(13)
Alloy K-500 bolts
L7
(8)(13)
ASTM A453, Class D, Grade 660 bolts
L8
(13)
ASTM A193, Class 2, Grade B8M bolts
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
32
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Digital Display
Standard Standard
M5 PlantWeb LCD Display
Special Procedures
Standard Standard
P1
(18)
Hydrostatic testing with certificate
P9
(2)
4500 psig (310 bar) static pressure limit
P0
(2)(19)
6092 psig (420 bar) static pressure limit
Expanded
P2
(13)
Cleaning for special services
P3
(13)
Cleaning for less than 1PPM chlorine/fluorine
Special Certifications
Standard Standard
Q4 Calibration Certificate
QP Calibration Certificate and Tamper Evident Seal
Q8 Material Traceability Certification per EN 10204 3.1B
Q16 Surface Finish Certification for Sanitary Remote Seals
QZ Remote Seal System Performance Calculation Report
Transient Protection
Standard Standard
T1 Transient terminal block
Conduit Electrical Connector
Standard Standard
GE
(20)
M12, 4-pin, Male Connector (eurofast
)
GM
(20)
A size Mini, 4-pin, Male Connector (minifast
)
Cold Temperature
Standard Standard
BRR -60 F (-51 C) Cold Temperature Start-up
Typical Model Number: 3051SMV 3 M 1 2 G 4 R 2 E12 A 1A B4 C2 M5
(1) Only available with DP range codes 2 and 3, 316L SST or Alloy C-276 isolating diaphragm and silicone fill fluid.
(2) Only available with Measurement Type codes 3 and 4.
(3) DP Range 0 is only available with traditional flange, 316L SST diaphragm material, and Bolting option L4.
(4) Required for Measurement Type codes 3 and 4.
(5) For Measurement Type 1 and 2 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are -14.2 to 2000 psig
(-0,98 to 137,9 bar).
(6) Required for Measurement Type codes 2 and 4.
(7) Required for Measurement Type codes 1 and 3. RTD Sensor must be ordered separately.
(8) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(9) Tantalum diaphragm material is only available for DP ranges 2-5.
(10) Assemble to items are specified separately and require a completed model number.
(11) Consult an Emerson Process Management representative for performance specifications.
(12) For use with Flowmeters with integral RTDs.
(13) Not available with process connection option code A11.
(14) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(15) Not available with M20 or G conduit entry size.
(16) RTD cable not available with this option.
(17) Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
(18) Not available with DP range 0.
(19) Requires 316L SST or Alloy C-276 diaphragm material, assemble to Rosemount 305 Integral Manifold or DIN-compliant traditional flange process connection, and bolting
option L8. Limited to differential pressure ranges 2-5.
(20) Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Non-Incendive approval (option code I5), install in accordance with Rosemount drawing
03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.