MTW SERIES
Multiple outputs/for general use 15-60W
DENAN
Built to meet
UL60950-1/
CSA C22.2 No.60950-1
EN60950-1/
EN50178
Low Voltage Directive Electrical Appliance
and Material Safety Law
(Input Voltage 100VAC)
Y
E
A
R
S
warranty
Model naming logic
MTW 15-5 12 12
Features
Worldwide-applicable input, triple-output type
Variation
C ompact, slim and lightweight contributing to
-V: With output voltage trim-mer
energy-saving and environmental protection
Nominal output voltage(output 3)
12: 12V
15: 15V
A pproved by safety standards (UL, C-UL, TV),
complying with Electrical Appliance and Material
Nominal output voltage(output 2)
12: 12V
15: 15V
Safety Law, CE marking applicable
E
MI: Complying with FCC Class B, VCCI-B,
Nominal output voltage(output 1)
5: 5V
EN55011-B, -B
Rated capacity
Immunity : Complying with EN61000-4-2,-3,-4,-5,
15: 15W
30: 30W
60: 60W
-6,-8,-11
Series name
Peak load accommodatable
Conformity to RoHS Directive
Applications
This means that, in conformity with EU Directive 2002/95/
EC, lead, cadmium, mercury, hexavalent chromium, and
specific bromine-based flame retardants, PBB and PBDE,
have not been used, except for exempted applications.
Product line up
Output voltage
15W
30W
60W
Output current (Peak current)/Model
Output current (Peak current)/Model
Output current (Peak current)/Model
+5V
2.0A3.0A
+12V
0.3A0.6A
-12V
0.2A0.3A
Output voltage
3.0A4.5A
MTW15-51212
1.2A2.0A
5.0A7.0A
MTW30-51212
0.3A0.45A
2.5A3.5A
MTW60-51212
0.5A0.7A
15W
30W
60W
Output current (Peak current)/Model
Output current (Peak current)/Model
Output current (Peak current)/Model
+5V
2.0A3.0A
+15V
0.3A0.6A
-15V
0.2A0.3A
Variation symbol
Function
None
Fixed output voltage type
-V
Output voltage adjustable type
3.0A4.5A
MTW15-51515
0.8A2.0A
0.3A0.45A
5.0A7.0A
MTW30-51515
2.0A3.5A
MTW60-51515
0.5A0.7A
Output voltage adjustable type: Indicated by "-V" added at the end of model
All specifications are subject to change without notice.
001-01/20080522/etl_mtw
MTW 15W
MTW15W
ITEMS/UNITS
MTW15W Specifications
MODEL
CH
Voltage Range (Nominal: 100-240VAC)
Frequency
(Nominal: 50-60 single phase)
Power Factor (100/240VAC)(typ)
Input
Efficiency (100/240VAC)(typ)
Current (100/240VAC)(typ)
Inrush Current (100/240VAC)(typ) (*1)
Leakage Current(max)
Nominal Voltage
(*2)
Maximum Current
(*3)
Maximum Peak Current
(*4)
Maximum Power
(P0[V1]+P0[V2]+P0[V3])
Voltage Setting Accuracy
(100/240VAC,100% load)
Maximum Line Regulation
(Within input voltage range)(max)
Maximum Load Regulation
Output
(10-100% load)(max)
Temperature Coefficient
(Ambient temperature -10 C to +50 C)(max)
Warm Up Drift (max)
(*5)
Max Power Total Regulation (max) (*2)
Maximum Ripple Voltage (max) (*6)
Maximum Ripple & Noise (max) (*6)
Start Up Time (100VAC)(max)
Hold-up Time (100/240VAC)(typ)
Voltage Adjustable Range
(*7)
Over Current Protection (min) (*8)
Over Voltage Protection (min) (*9)
Over Temperature Protection
Remote Sensing
Function Remote ON/OFF Control
Parallel Operation
Series Operation
Operation Indicator
Monitoring Signal
Operating Temperature
Storage Temperature
Operating Humidity
Environment Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
Standards
EMI
Immunity
Weight (max)
Mechanical
Size (W x H x D)
MTW15-51212
2
AC85-265
Hz
47-440
MTW15-51515
2
0.55/0.45
A
A
mA
VDC
A
A
71/70
68/70
0.42/0.25
25/50
0.75 (100VAC (Electrical Appliance and Material Safety Law) / 240VAC (UL, IEC))
+5 [V1]
+12 [V2]
-12 [V3]
+5 [V1]
+15 [V2]
-15 [V3]
2
0.3
0.2
2
0.3
0.2
3
0.6
0.3
3
0.6
0.3
16
+5 0.25
17.5
+12 0.6
-12 0.6
+5 0.25
+15 0.6
-15 0.6
0.4%
2.0%
1.0%
mVp-p
mVp-p
ms
ms
VDC
A
VDC
2.0%
1.0%
1.0
2.0
1.0
2.0
1.0
2.0
2.0
100
120
120
150
100
120
120
150
100
20/150
Fixed/Variable (CH1)
3.15
0.63
0.32
3.15
0.63
0.32
5.7
Not available
5.7
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
-10 to +60
-30 to +75
RH 10-90 (the conditions of maximum 35
C in wet bulb temperature and non-condensation should be ensured.)
RH 10-90 (the conditions of maximum 35
C in wet bulb temperature and non-condensation should be ensured.)
5-10Hz, 10 minutes sweep, 10mmp-p total amplitude, 3 directions, 1h for each, in non-operation
10-200Hz, 10 minutes sweep, 19.6m/s (2G) acceleration, 3 directions, 1h for each, in non-operation
588m/s (60G), 11 5ms, 3 directions, 3 times for each, in non-operation
For 1 minute at ordinary temperature and humidity
Between input terminal and ground terminal: 2.0kVAC, 10mA cutout current
Between input terminal and output terminal: 3.0kVAC, 10mA cutout current
Between output terminal and ground (G): 500VAC, 20mA cutout current
In 500VDC and 100M or over at ordinary temperature and humidity
Between input terminal and ground terminal, between input terminal and output terminal,
and between output terminal and ground terminal
Approved by UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (TV),
complying with Electrical Appliance and Material Safety Law
(meeting the regulations of creepage surface and spacial distance in item 8 of the appendix table)
Complying with FCC-Class B / VCCI-Class B / EN55011-B / EN55022-B
Complying with EN61000-4-2 Level 4, -3 Level 3, -4 Level 3, -5 Level 4, -6 Level 3, -8 Level 4, -11
g
150
mm
26 x 50 x 127
With nominal input/output voltage, maximum output current, and Ta=25
C, if not specified separately.
(*1) In primary surge current, 25
C, and cold starting.
(*2) Overshoot in starting input is 4%typ. Floating system is used for V1-V2 and V1-V3.
(*3) The maximum output current value is between -10
C and +50
C. For use in outside this temperature range, derating is needed.
(*4) Flowing time should be within 10 seconds and the effective current/power should be the same as or less than the maximum
current/power.
(*5) 30min to 8h after the start of input voltage application.
(*6) In 100MHz, -10C-0C. Ripple: V1-140mVp-p max, V2, V3-160mVp-p max. Ripple noise : V1-160mVp-p max, V2/V3-180mVp-p max.
(*7) For output voltage adjustable types (variation), output voltage can be varied in the range of +5V through +5.25V for CH1 (+5V)
only, by the output voltage trimmer.
(*8) When the other channels are in 0A. Fold-back type drooping system and automatically resumes when the causes are removed.
(*9) For V1 only: Zener clamp system
All specifications are subject to change without notice.
Recommended EMC Filter
RSEL-2001W
Please refer to "TDK-Lambda
EMC Filters" catalog.
MTW 15W
Outline Drawing
UP
1
Name plate
7MAX.
7max.
5
6max.
(4.5)
B
Ground pattern/Spacer area
Solder side (1 location point)
Area for mounting screw
Side with components (1 location point)
Spacer area
Solder side (3 location points)
Area for mounting screw
Side with components (3 location points)
Unit: mm
Allowable dierence is 1mm if not specied separately.
CN1Input side
CN51Output side
P8 V3 Output 3
Ground
L
3max.
8
7
6
5
4
CN51
3
2
1
3 CN1
P1
23
(1.6)
CN51
7max.
6max.
3MAX.
OUTPUT
Area for mounting
components CONNECTOR
8
Output voltage trimmer (option)
UP
Specications of terminals
P3 N
P5
7MAX.
34.1
7MAX.
7MAX.
CN51
4.5
12.2
3.5
23
1.6
( )
1 3.5
(4)
(17.6)
50
1
4
Mounting hole
4-3.5
Output connector
CN1 3
5
1200.5
INPUT CONNECTOR
5
17.6
7MAX.
430.5
50
(3.5)
430.5
3.5
127
4.5
3.5
3.5
CN1
7MAX.
7MAX.
Input connector
4-3.5
3.5
1200.5
(12.2)
3.5
Name plate
127
7MAX.
MTW15W
P7
Neutral
P6
Live
G2 Ground 2
P5 V2 Output 2
- VH series B3P5-VH-B
by J.S.T. Mfg. Co., Ltd.
P4
P3
P2
P1
G1 Ground 1
V1 Output 1
- XH series B8B-XH-2
by J.S.T. Mfg. Co., Ltd.
Maximum output power (%)
Output Power - Ambient Temperature (Derating Curve)
Shows derating for products without
covers.
For (A)-(F), refer to the item regarding
Ambient temperature (
C)
In the range indicated by
, operation is
possible but the characteristics are not guaranteed.
All specifications are subject to change without notice.
MTW 30W
MTW30W
ITEMS/UNITS
MTW30W Specifications
MODEL
CH
Voltage Range (Nominal: 100-240VAC)
Frequency
(Nominal: 50-60 single phase)
Power Factor (100/240VAC)(typ)
Input
Efficiency (100/240VAC)(typ)
Current (100/240VAC)(typ)
Inrush Current (100/240VAC)(typ) (*1)
Leakage Current (max)
Nominal Voltage
(*2)
Maximum Current
(*3)
Maximum Peak Current
(*4)
Maximum Power
(P0[V1]+P0[V2]+P0[V3])
Voltage Setting Accuracy
(100/240VAC,100% load)
Maximum Line Regulation
(Within input voltage range)(max)
Maximum Load Regulation
Output
(10-100% load)(max)
Temperature Coefficient
(Ambient temperature -10C to +50C) (max)
Warm Up Drift (max)
(*5)
Max Power Total Regulation (max) (*2)
Maximum Ripple Voltage (max) (*6)
Maximum Ripple & Noise (max) (*6)
Start Up Time (100VAC)(max)
Hold-up Time (100/240VAC)(typ)
Voltage Adjustable Range
(*7)
Over Current Protection (min) (*8)
Over Voltage Protection (min) (*9)
Over Temperature Protection
Remote Sensing
Function Remote ON/OFF Control
Parallel Operation
Series Operation
Operation Indicator
Monitoring Signal
Operating Temperature
Storage Temperature
Operating Humidity
Environment Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
Standards
EMI
Immunity
Weight max
Mechanical
Size (WxHxD)
MTW30-51212
2
AC85-265
Hz
47-440
A
A
mA
VDC
A
A
0.55/0.45
76/77
0.8/0.4
20/40
0.55/0.75 (100VAC (Electrical Appliance and Material Safety Law) / 240VAC (UL, IEC))
+5 [V1]
12 [V2]
-12 [V3]
+5 [V1]
+15 [V2]
-15 [V3]
3
1.2
0.3
3
0.8
0.3
4.5
2
0.45
4.5
2
0.45
mVp-p
mVp-p
ms
ms
VDC
A
VDC
30
+5+0.3, -0.1
33
+12 0.6
-12 0.6
+5+0.3, -0.1
+15 0.75
-15 0.75
1.0%
0.4%
1.0%
0.4%
2.0%
1.0%
2.0%
1.0%
2.0
1.0
2.0
1.0
3.0
80
120
2.0
100
150
3.0
80
120
2.0
100
150
1.0
300
20/140
Fixed/Variable (CH1)
4.7
2.1
0.48
4.7
2.1
0.48
5.8
Not available
5.8
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
-10 to +60
-30 to +75
RH 10-90 (the conditions of maximum 35
C in wet bulb temperature and non-condensation should be ensured.)
RH 10-90 (the conditions of maximum 35
C in wet bulb temperature and non-condensation should be ensured.)
5-10Hz, 10 minutes sweep, 10mmp-p total amplitude, 3 directions, 1h for each, in non-operation
10-200Hz, 10 minutes sweep, 19.6m/s (2G) acceleration, 3 directions, 1h for each, in non-operation
588m/s (60G), 11 5ms, 3 directions, 3 times for each, in non-operation
For 1 minute at ordinary temperature and humidity
Between input terminal and ground terminal: 2.0kVAC, 10mA cutout current
Between input terminal and output terminal: 3.0kVAC, 10mA cutout current
Between output terminal and ground (G): 500VAC, 20mA cutout current
In 500VDC and 100M or over at ordinary temperature and humidity
Between input terminal and ground terminal, between input terminal and output terminal,
and between output terminal and ground terminal
Approved by UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (TV),
complying with Electrical Appliance and Material Safety Law
(meeting the regulations of creepage surface and spacial distance in item 8 of the appendix table)
Complying with FCC-Class B / VCCI-Class B / EN55011-B / EN55022-B
Complying with EN61000-4-2 Level 4, -3 Level 3, -4 Level 3, -5 Level 4, -6 Level 3, -8 Level 4, -11
g
210
mm
26 x 65 x 140
With nominal input/output voltage, maximum output current, and Ta=25
C, if not specified separately.
(*1) In primary surge current, 25
C, and cold starting.
(*2) Overshoot in starting input is 4%typ. Floating system is used for V1-V2 and V1-V3.
(*3) The maximum output current value is between -10C and +50C. For use in outside this temperature range, Derating is needed.
(*4) Flowing time should be within 10 seconds and the effective current/power should be the same as or less than the maximum
current/power.
(*5) 30min to 8h after the start of input voltage application.
(*6) In 100MHz, -10C-0C. Ripple: V1-140mVp-p max, V2, V3-160mVp-p max. Ripple noise: V1-160mVp-p, V2/V3-180mVp-p max.
(*7) For output voltage adjustable types (variation V), output voltage can be varied in the range of +5V through +5.2V for CH1 (+5V)
only, by the output voltage trimmer.
(*8) When the other channels are in 0A. Fold-back type drooping system and automatically resumes when the causes are removed.
(*9) For V1 only: Zener clamp system
All specifications are subject to change without notice.
MTW30-51515
2
Recommended EMC Filter
RSEL-2001E
Please refer to "TDK-Lambda
EMC Filters" catalog.
MTW 30W
Outline Drawing
UP
Name plate
140
1320.5
140
1320.5
570.5
7MAX.
INPUT
CONNECTOR
7MAX.
38.5
CN2
6
Area for mounting
components
7max.
Name plate
6max.
Specications of terminals
6max.
Ground pattern/Spacer area
Solder side (1 location point)
Area for mounting screw
Side with components (1 location point)
Spacer area
Solder side (3 location points)
Area for mounting screw
Side with components (3 location points)
Unit: mm
Allowable dierence is 1mm if not specied separately.
CN2 4 3
5
6
5
3
UP
3max.
OUTPUT
CONNECTOR
(4)
1 Output voltage trimmer (option)
7max.
23
(1.6)
(45.9)
6.7
7MAX.
(14.1)
65
CN1
14.1
65
570.5
CN2
(4.5)
1
Output connector
(4)
4-3.5
3MAX.
1.6
4.5
CN1
23
7MAX.
Input connector
(4)
4
7MAX.
7MAX.
7MAX.
7MAX.
45.9
MTW30W
4-3.5
Mounting hole
CN1
CN1Input side
P5
CN2Output side
P1 V3 Output 3
Ground
P3 N Neutral
P1
P2
P3
Live
G2 Ground 2
P4 V2 Output 2
- VH series B3P5-VH-B
by J.S.T. Mfg. Co., Ltd.
P5 G1 Ground 1
P6 V1 Output 1
- VH series B6P-VH-B
by J.S.T. Mfg. Co., Ltd.
Maximum output power (%)
Output Power - Ambient Temperature (Derating Curve)
Shows derating for products without
covers.
For (A)-(F), refer to the item regarding
Ambient temperature (
C)
In the range indicated by
, operation is
possible but the characteristics are not guaranteed.
All specifications are subject to change without notice.
MTW 60W
MTW60W
ITEMS/UNITS
MTW60W Specifications
MODEL
CH
Voltage Range (Nominal: 100-240VAC)
Frequency
(Nominal: 50-60 single phase)
Power Factor (100/240VAC)(typ)
Input
Efficiency (100/240VAC)(typ)
Current (100/240VAC)(typ)
Inrush Current (100/240VAC)(typ) (*1)
Leakage Current (max)
Nominal Voltage
(*2)
Maximum Current
(*3)
Maximum Peak Current
(*4)
Maximum Power
(P0[V1]+P0[V2]+P0[V3])
Voltage Setting Accuracy
(100/240VAC,100% load)
Maximum Line Regulation
(Within input voltage range)(max)
Maximum Load Regulation
Output
(10-100% load)(max)
Temperature Coefficient
(Ambient temperature -10 C to +50 C)(max)
Warm Up Drift (max)
(*5)
Max Power Total Regulation (max) (*2)
Maximum Ripple Voltage (max) (*6)
Maximum Ripple & Noise (max) (*6)
Start Up Time (100VAC)(max)
Hold-up Time (100/240VAC)(typ)
Voltage Adjustable Range
(*7)
Over Current Protection (min) (*8)
Over Voltage Protection (min) (*9)
Over Temperature Protection
Remote Sensing
Function Remote ON/OFF Control
Parallel Operation
Series Operation
Operation Indicator
Monitoring Signal
Operating Temperature
Storage Temperature
Operating Humidity
Environment Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
Standards
EMI
Immunity
Weight max
Mechanical
Size (W x H x D)
MTW60-51212
1
MTW60-51515
3
AC85-265
Hz
47-440
A
A
mA
VDC
A
A
0.55/0.45
76
1.4/0.8
20/40
0.6/0.75 (100VAC (Electrical Appliance and Material Safety Law) / 240VAC (UL, IEC))
+5 [V1]
12 [V2]
-12 [V3]
+5 [V1]
+15 [V2]
-15 [V3]
5
2.5
0.5
5
2
0.5
7
3.5
0.7
7
3.5
0.7
60
+12 0.6
+5+0.3, -0.1
1.0%
mVp-p
mVp-p
ms
ms
VDC
A
VDC
62.5
-12 0.6
+15 0.6
+5+0.3, -0.1
0.4%
1.0%
-15 0.75
0.4%
2.0%
1.0%
2.0%
1.0%
2.0
1.0
2.0
1.0
2.5
2.0
1.0
80
120
100
150
2.5
80
120
2.0
100
150
350
550
20/180
Fixed/Variable (CH1)
7.4
3.7
0.75
7.4
3.7
0.75
5.8
13.8
Not available
5.8
16.5
Not available
Not available
Not available
Not available
Not available
Not available
Not available
Not available
-10 to +60
-30 to +75
RH 10-90 (the conditions of maximum 35
C in wet bulb temperature and non-condensation should be ensured.)
RH 10-90 (the conditions of maximum 35
C in wet bulb temperature and non-condensation should be ensured.)
5-10Hz, 10 minutes sweep, 10mmp-p total amplitude, 3 directions, 1h for each, in non-operation
10-200Hz, 10 minutes sweep, 19.6m/s (2G) acceleration, 3 directions, 1h for each, in non-operation
588m/s (60G), 11 5ms, 3 directions, 3 times for each, in non-operation
For 1 minute at ordinary temperature and humidity
Between input terminal and ground terminal: 2.0kVAC, 10mA cutout current
Between input terminal and output terminal: 3.0kVAC, 10mA cutout current
Between output terminal and ground (G): 500VAC, 20mA cutout current
In 500VDC and 100M or over at ordinary temperature and humidity
Between input terminal and ground terminal, between input terminal and output terminal,
and between output terminal and ground terminal
Approved by UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (TV),
complying with Electrical Appliance and Material Safety Law
(meeting the regulations of creepage surface and spacial distance in item 8 of the appendix table)
Complying with FCC-Class B / VCCI-Class B / EN55011-B / EN55022-B
Complying with EN61000-4-2 Level 4, -3 Level 3, -4 Level 3, -5 Level 4, -6 Level 3, -8 Level 4, -11
g
330
mm
26 x 83 x 185
With nominal input/output voltage, maximum output current, and Ta=25
C, if not specified separately.
(*1) In primary surge current, 25
C, and cold starting.
(*2) Overshoot in starting input is 4%typ. Floating system is used for V1-V2 and V1-V3.
(*3) The maximum output current value is between -10
C and +50
C. For use in outside this temperature range, Derating is needed.
(*4) Flowing time should be within 10 seconds and the effective current/power should be the same as or less than the maximum
current/power.
(*5) 30min to 8h after the start of input voltage application.
(*6) In 100MHz, -10
C-0
C. Ripple: V1-140mVp-p max, V2/V3-160mVp-p. Ripple noise : V1-160mVp-p max, V2/V3-180mVp-p max.
(*7) For output voltage adjustable types (variation V), output voltage can be varied in the range of 4.5V through 5.5V for CH1 (+5V)
only, by the output voltage trimmer.
(*8) When the other channels are in 0A. Fold-back type drooping system and automatically resumes when the causes are removed.
(*9) For V1 only: Zener clamp system
All specifications are subject to change without notice.
Recommended EMC Filter
RSEL-2003W
Please refer to "TDK-Lambda
EMC Filters" catalog.
MTW 60W
Outline Drawing
185
1770.5
4
1110.5
1110.5
INPUT CONNECTOR
7MAX.
(5)
B
7MAX.
B
5
7MAX.
Name8max.
plate
Name plate
UP
23
(1.6)
3max.
7MAX.
55.4
3
1
5) Output connector
(4
5-3.5
CN2
8MAX.
7max.
750.5
360.5
83
185
1770.5
CN1
(54.1)
5
3
1
5
23
3MAX.
1.6
OUTPUT
CONNECTOR
7MAX.
CN2
30.6
8
Area for mounting
components
(55.4)
(4)
83
54.1
750.5
360.5
CN1
Input connector
8MAX.
7MAX.
8max.
7MAX.
MTW60W 7MAX.
4 5-3.5
Mounting hole
Output voltage trimmer (option)
UP
Ground pattern/Spacer area
Solder side (1 location point)
Area for mounting screw
Side with components (1 location point)
6max.
Spacer area
B
Solder side (3 location points)
Area for mounting screw
Side with components (3 location points)
A
4
7max.
4
6max.
Specications of terminals
Unit: mm
Allowable dierence is 1mm if not specied separately.
5
3 CN1
1
1
2
4 3
CN2
5
6
7
8
CN1
CN2
P5
P1 V3
P3 N
P2
P1
P3
G2
P4 V2
- VH series B3P5-VH-B
by J.S.T. Mfg. Co., Ltd.
P5
P6
P7
P8
G1
V1
- VH series B8P-VH-B
by J.S.T. Mfg. Co., Ltd.
Maximum output power (%)
Output Power - Ambient Temperature (Derating Curve)
Shows derating for products without
covers.
For (A)-(F), refer to the item regarding
Ambient temperature (
C)
In the range indicated by
, operation is
possible but the characteristics are not guaranteed.
All specifications are subject to change without notice.
MTW SERIES
Block Diagram
MTW15W
Input lter
circui
AC input
N
Output current
smoothing circuit
Inrush current
prevention/input
lter circuit
Over voltage
protection circuit
MOSFET
switch
V
OUTPUT
GND
1
Output current
smoothing circuit
Over voltage
protection circuit
Control circuit
V
OUTPUT
GND
2
Over voltage
protection circuit
Output current
smoothing circuit
V
OUTPUT
Control circuit
MTW30W
Inrush current
prevention/
input lter
circuit
AC input
N
Output current
smoothing circuit
Input rectication
circuit
Current
detection
Control circuit
Over voltage
protection circuit
MOSFET
switch
Auxiliary
power
supply
V
OUTPUT
GND
G1
Output current
smoothing circuit
Over voltage
protection circuit
V
OUTPUT
Over voltage
protection circuit
V
OUTPUT
GND
G2
Output current
smoothing circuit
Control circuit
MTW60W
AC input
N
Inrush current
prevention/
input lter
circuit
Output current
smoothing circuit
Input rectication
circuit
Current detection
Control circuit
Over voltage
protection circuit
MOSFET
switch
V1:OUTPUT
GND
G1
Auxiliary
power supply
Control circuit
Output current
smoothing circuit
Current detection
Control circuit
MOSFET
switch
Auxiliary
power supply
V2:OUTPUT
Over voltage
protection circuit
V3:OUTPUT
GND
G2
Output current
smoothing circuit
Control circuit
All specifications are subject to change without notice.
Over voltage
protection circuit
MTW SERIES
MTW series Instruction Manual
1. Explanation of functions and notes
1 EMI and ESD measurement method
5 CE marking
MTW series meets the EN60950-1 standards and the CE
marking is applicable to this series, based on 73/23/EEC
and 93/68/EEC. The custom-made power supply units
8mm
device are not basically CE-marking applicable, except
Filler piece6mm
Metal plate
when
max.
"CE-marking applicable" is specifically declared in their
specification documents.
2 Ripple and ripple noise measurement
C1: 100 electrolytic capacitor
C2: 0.1F film capacitor
Power supply for test
(variation models) modified from this DC power supply
6 Operation of Over Current Protection
150mm
Note that if nonlinear loading such as by lamp or motor,
Output connector
C2
C1
and constant current load is connected, output voltage
Load
may not be generated when starting up. Also, there is a
restriction in the connectable load capacity. Check it in
the specification document.
Mesurement point
7 Over Voltage Protection
3 Maximum peak current
A protection circuit which clamps the output voltage with
Peak current flow can be allowed. However, observe
the zener diode is incorporated, in order to prevent the over
the conditions shown below for a peak current over the
voltage output when in an unusual current condition.
nominal value.
When this circuit is activated, restart is impossible.
I1
8 Other points to be noted
This product has surface-mount components on the bottom
I2
panel (solder side). Vibration, impact, and distortion, etc. in
the board can cause failure due to chip crack. Be careful
in handling.
D = t T
(1) Condition of time
t 10 seconds
(2) Condition of peak current I1 Maximum peak current
(3) Condition of effective current DI + (1-D) x I Maximum current
(4) Condition of effective power P Maximum power
4 Minimum output current
15W/60W type
There is no restriction in minimum output current value.
30W type
The CH1 (+5V) output current should be 0.5A or over
when in use.
If it is 0.5A or lower, the regulations for the other
channels cannot be satisfied.
All specifications are subject to change without notice.
10
MTW SERIES
2.Mounting
1 Mounting direction
(A) Standard mounting
Input connector
Output connector
Output connector
Input connector
Input connector
Input connector
Input connector
Input connector
The standard mounting method of the power supply unit to a device
is (A). The methods (C) through (F) are also available.
The method (B) should not be used. This can cause overheating.
When using for mounting methods (A) and (C) through (F), operate
the unit within the derating curve shown in Fig-1.
2 Mounting method
Use spacers (filler pieces: 6mm max) in the mounting
4mm min.10mm
holes on the board. Keep a space of 8mm or over. Also
keep a spacial distance (4mm or over) in order to satisfy
the insulation regulations/withstand voltage. If a spacial
8mm min.
distance (4mm or over) cannot be kept, insert an insulating
plate, etc. It is also recommended to keep a distance of
10mm or over from adjacent devices, in order to generate
Filler piece6mm
Metal plate
max.
thermal convection.
4mm min.10mm 4mm min.10mm
Frame
MTW15W
4mm min.10mm
4mm min.10mm
3. Precautions in use
When this product is in use, confirm that the power
quality of the electrolytic capacitor.
supply's ambient temperature is within the range of
When the power supply units are in a series operation,
operating temperatures. The power supply's ambient
the nominal current is restricted according to the lowest
temperature means the temperature around the power
supply unit, causing a temperature rise inside the device.
nominal current value of the units in use. In addition, in
order to prevent damage to internal elements and other
For use with natural air cooling, locate the unit so as to
parts due to reverse voltage applied to the unit, connect
generate thermal convection. Also keep a distance of 10mm
a diode (reverse withstand voltage: twice or over the
or over from adjacent devices, from each side of the unit.
value of total output voltage, forward current: twice or
Select input/output wire materials and noise filters, etc.
over the value of output current, forward voltage drop:
which have enough allowance in their respective current
possibly minimum) to prevent reverse voltage, to the
capacity.
output terminal of the unit.
If the power supply unit is not in use for a long period
of time, it is recommended to apply input voltage for
approximately 1 hour, every 2 years, to maintain the
No materials used in this product contain the bromine
fire retardant (PBDPEs, PBBs).
No ODS are used in the production of this product.
4. Troubleshooting
Is the specified input voltage being applied to the input
terminal?
All specifications are subject to change without notice.
Are the connections of input/output terminals correct?
Check that the connecting wires are not too thin.