Compact
Temperature controller
(size: 48 x 48) Type: PXE
Slim! Easy operation! Compact
Light up when control action (OUT)
Light up when alarm output (AL1)
Light up when alarm output (AL2)
Displaying the Process
value(PV) and parameter
display symbols when each
parameter is set
Light up during setting value
(SV) display is ON, Light out
when parameter setting
Displaying the Setting value
(SV) and setting value of each
parameter
Light up when stand-by
1) Down key for setting value
(SV) etc..
2) PID auto-tuning start key
(hold down +Down key )
Parameter block selection
key
Parameter select key
1) UP key for setting value (SV) etc..
2) Stand-by key (hold down +UP key)
Super slim type. Renewal front design (Depth of front display is 1.6mm.
world's thinnest one)
Short depth dimensions! 62mm
Programmable setting for type of temperature input/
3-year
measuring range as standard!
warranty
and
Changeable setting for resistance-bulb (Pt100) , thermocouple (9 types)
measuring range with front key
Flexible about any controlled objects!
-ON/OFF control , PID control and Fuzzy control (auto-tuning)
-Relay contact output or SSR/SSC drive output (specified by code of symbol)
Alarm output 1point or up to 2 points are provided (2points is optional)
Free PC loader software allows you to reconfigure when start-up adjustment
or maintenance (under development)
Front water proof structure (IP66)
21B1-E-0017
2
21
1B1
B -E
E-0
00
01
17
S i m p l e a n d E as y O p e r a t i o n P X E !!!
Stand-by and soft-start
functions are provided
Control output 1point
Relay contact output, SSR/SSC drive
output, ON/OFF control and Fuzzy
control (with auto-tuning)
Input signal 1point
Capable of changing over temperature
type (resistance-bulb, 9 types of
thermocouples) with front key.
Alarm output
Imput sampling
cycle 200ms
1point or 2points (2points is optional)
High, Low and High/Low alarm output (settable
absolute value alarm, deviation alarm and zone
alarm)
PXE Model Code Configuration
'LJLW
6SHFLILFDWLRQ
)URQWGLPHQVLRQV!
[PP
<
3;(
Power supply voltage (100 to 240V AC)
< (
Scope of delivery
Controller ...........................1unit
Panel mounting bracket ......1set
,QSXWVLJQDO!
7KHUPRFRXSOH5HVLVWDQFHEXOE3W>&@
7KHUPRFRXSOH5HVLVWDQFHEXOE3W>)@
&RQWURORXWSXW!
5HOD\FRQWDFWRXWSXW
66566&GULYHRXWSXW
5HYLVLRQFRGH!
$ODUPRXWSXW!
$ODUPSF
$ODUPSFV
,QVWUXFWLRQPDQXDO!
-DSDQHVH(QJOLVK&KLQHVH
7
5
watertight packing ..............1psc
Instruction manual ............1copy
Items to be sold separately
$
&
- Terminal cover : Type (ZZPPXR1-A230)
- PC loader communication cableTQ401838P1
under development
<
Input signal, measurement range, and set value at the time of
deliver are as follows.
Thermocouple K, Measurement range; 0 to 400, Set value; 0
Input signal of the thermocouple and the resistance bulb can be switched by
key operation on the front panel.
<
Outline diagram (Unit: mm)
Outline
Panel cut
0RXQWLQJEURFNHW
SV
3DQHO
STBY
STBY
0,1
AT
:DWHUSURRI
SDFNLQJ
3DQHOWKLHNQHVVW
W
AL2
PV
0,1
AL1
Q
OUT
6LGHVWLFNPRXQWLQJQXQLWV
1RWH:DWHUSURRILVQRWDYDLODEOHLQ
VWLFNPRXQWLQJ
1RWH:KHQLQVWDOODWLRQVLGHE\VLGH
LVLQXVHZKLFKLVQRWFRYHUHG
XQGHU\HDUZDUUDQW\
Specifications
Thermocouple: J, K, R, B, S, T, E, N, PLII
Resistance bulb: Pt100
Relay contact: (1a) or SSR / SSC drive (voltage pulse)
Control output
Thermocouple input: 0.5% FS 1digit 1
Indication accuracy
For thermocouple B at 0 to 500: 5% FS 1 digit 1
For thermocouple R at 0 to 400: 1% of FS 1 digit 1C
Resistance bulb input:0.5% FS 1digit1
Proportional band (P): 0.1 to 999.9%
Control parameter
Integral time (I):0 to 3200 sec (I = 0 I action cut)
Differential time (D): 0 to 999.9 sec
Control cycle: 200ms
ON/OFF control, PID control/ Fuzzy control (with PID
Control action
auto-tuning)
Process value (PV) display: 7-segment, 4digits (Red LED)
Display section
Setting value (SV) display: 7-segment, 4digits (Green LED)
Status display : 6 indicator lamps
Sheet key type (with emboss), 4keys
Setting section
PC loader communication PC (USB) Temperature controller (under development)
Input signal
Output: 1point or 2 points(option)
Relay contact output: 1a contact
Alarm kind: Absolute alarm, deviation alarm, zone
alarm with upper and lower limits for
each, main unit malfunction
100V to 240V AC, 50/60 Hz
Power supply
100V AC: 5VA
Power consumption
220V AC: 6VA
Thermocouple: 1 M or more
Input impedance
Allowable signal source resistance Resistance bulb: 10 or less per wire
10% of measuring range
Input value correction
0 to 120.0 sec (primary lag filter)
Input filter
Panel flush mounting
Mounting method
External connection terminal M3 screw terminal
484863.5mm
Dimensions
Approx. 100 g
Weight
Ambient operating temperature -10C to 50C
Alarm output
,QWHUQDWLRQDO6DOHV'LY
6DOHV*URXS
*DWH&LW\2KVDNL(DVW7RZHU2VDNLFKRPH
6KLQDJDZDNX7RN\R-DSDQ
KWWSZZZIXMLHOHFWULFFRP
3KRQH)D[
KWWSZZZIXMLHOHFWULFFRPSURGXFWVLQVWUXPHQWV
,QIRUPDWLRQLQWKLVFDWDORJLVVXEMHFWWRFKDQJHZLWKRXWQRWLFH
3ULQWHGLQ-DSDQ)2/6