Installation: Software
package
New SW
Extract the SW archive file using
ZIXX
Create new SW package
ZWQC:NAME=<package name>,
Change the SW package to NW
DIRE=Q4011400:FORM=FAILED
ZWSC
Copy customer specific feature file FIFILE to LFILES directory and
Copy licence files to LICENCE directory
ZIWY:S
ZIWY:D
ZIBC
Create CDTEMP directory on the new SW package directory
Delivery
Change
Extracting CD archive file into CDTEMP
Add the Change Delivery
Creating another SW package on the same directory with new SW package directory
Activate SW package that contains CD
ZIWL::WS,NODEF:<package directory>:CDTEMP;
ZIXX:,/,R400000N.ZIP::,/Q4011400/CDTEMP:TIME=2400,PATHS=N;
ZWNA:STAT=NW:1
ZWQC:NAME=R400000N,DIRE=..,:FORM=FAILED,CW=NEW,;
ZWSS:NAME=R400000N;
Activate the SW package by defining new default SW package, and it will automatically bring system restart
Change the new SW package
status to BU
ZWSD:STAT=NW
ZWSC:NAME=R400000N, STAT=BU;
Commissioning (1/4)
Service Terminal remote session
in the OMU
ZDSS:OMU;
Activate the RCJUUS Service Terminal extension
ZLP:1,RCJ;
Create new user profile (OPTIONAL) in
using port 11111
connection to the OMU IP
Quit to Service Terminal remote session
Check the connection createed between logical files
used for printing alarms and the VPP device
Change the connection createed between logical files
Z1I:ALL;
ZE
ZIAH:<user ID>, <profile>;
ZIID::<logical file name>:LF=ALARMS:DEV=VPP-99
ZIIS::<logical file name>:LF=ALARMS:DEV=VPP-97
used for printing alarms and the VPP device
Check the VPP state
Service Terminal remote session
in the OMU
Activate the HME Service Terminal extension for HMS System
HMS SYSTEM
TELNET or HTTP
Monitoring the start-up unit
Display HMS system configuration
Check HMN SW version in single unit
Quit to Service Terminal remote session
Modify time and date
Define NTP IP Server address
ZIHI:VTP=97
ZDSS:OMU;
ZLP:2,HME;
Z2DP;
Z2CO:<cabinet>, <subrack>, <ppa> ;
ZE;
ZDCS: <date>, <time>: ST<summer time>;
ZDCM: <ip version>, <ip address>;
INTERROGATION
EQDATA
Commissioning (2/4)
Interrogate cabinet information
ZWFI:J;
Interrogate subrack information
ZWFI:C;
Interrogate plug in unit address information
ZWFI:P:[<plug-inunittype>],[<plug-inunitindex>]:
[<cabinetHMSnumber>],[<subrackHMSnumber>],
[<PPA>]:[<subracklocation>]:[<unittype>],[<unit
index>],[<unitgroupindex>]:[<masterunittype>],
[<masterunitgroupindex>];
Interrogate port information in plug in unit
ZWFI:S:<cabinetHMSnumber>,<subrackHMSnumber>,
EEPROM
IN UNIT
SW DATA
HW DATA
<PPA>,[<porttype>],[<portindex>];
Interrogate plug-in unit data
Interrogate subrack data
ZWFL:P;
ZWFL:S;
Interrogate software package structure in SOMAFI that
poins to 8 packages in WDU
ZWQO:CR;
Check the erroueous version of the software package
ZWQB:NAME<sw build name>:FORM=FAILED;
Check the version of single plug.in unit
ZWDI:UT=<functional unit type>;
Update the SW in plug-in unit If is different than WDU
ZWDR:UT=<unit type>, UI=<unitindex>;
Reset the unit for activating the SW in the plug.in unit
ZUSU:<unit type>,<unitindex>;
Commissioning (3/4)
ZIHI
Interrogate I/O device state (i.e. WDU)
SWITCHOVER OK
I/O DEVICES
OF PLUG-IN UNIT AND
SYNCRONIZATION
CORRECT POSITION
ZIHE
Change I/O device state
Start I/O device total test
ZUDD
Interrogate the current test
ZUDQ
Display the Diagnostic report
ZUDH
Service Terminal remote session
in the OMU
Activate the HME Service Terminal extension for HMS System
Display all computing unit in messaging system
Check If the unit answer (so If the switchover works)
Quir to Service Terminal remote session
Interrogate syncronization system
Check which SET are active for collecting external syncronization
ZDSS:OMU;
ZLP:3,POH;
Z3F:::1;
Z3YY;
ZE;
ZDYI:;
ZDYP:;
REPORT TO NETACT
VDS FOR STATISTICAL
Commissioning (4/4)
ZIFF:<unit>:<application>:SIZE=<diskfilesize>,
AMO=<diskfileamount>,COMP=<compressionmode>,
Logical file definition for association with VDS
SKIP=<skippingmode>,OVERW=<overwritemode>;
ZIIS:<systemname>,<destinationunit>:<logicalfile
Connect logical file to
the VDS
name>,<logicalfiletype>:<currentobject
identification>:<newobjectidentification>;
Interface integration (1/2) (ATM over SDH)
ZYA..
SET, PET,
IMA, PROTGR
?
ZYBC
IMA Group
ZYWC PROT GROUP
ZYBI
ZYWI
SET, PET
ZYDC
PHYSICAL TRAIL TERMINATION POINT
ZLAC ATM INTERFACE
ZLAI
ZLAF ACCESS PROFILE
ZLAQ
ZYDI
Iub
INTERFACE TYPE
NEMU GUI: COCO, FMC, WBTS, WCELL, HOP,
MML: O&M LINK
Iu-CS, Iu-PS, Iur
ZLCC VP TERMINATION POINT
ZLCI
ZLCC VC TERMINATION POINT
ZLCI
SIGNALLING
SIGNALLING,
USER DATA
?
ZQMF
ZQRN
USER DATA
ZQKC
IP OVER ATM INTERFACE
IP ADDRESS FOR
IP OVER ATM INTERFACE
DEFAULT/STATIC ROUTES
ZQMI
ZQRI
ZQKB
Interface integration (2/2) (ATM over SDH)
SIGNALLING
USER DATA
SIGNALLING,
USER DATA
ZNPC
ZNRP
SS7
OWN SPC
ZNRI
SIGNALLING LINK
ZNCI
Iu-CS, Iur
IP
SS7 vs. IP
ASSOCIATION SET
ZOYA
ASSOCIATION
ZOYN SOURCE IP
ZOYI
ZRRC
ZOYL ZLIC
ATM ROUTE
ZRRI ZQMF IP OVER ATM INTERFACE ZQMI
ENDPOINT GROUP
ZLII
ZQRN
ZNSC/ZNSP
ZNRC
ZNLA
ZNLC
ZNVA
SIGNALLING LINK SET
ZNSI
SIGNALLING ROUTE SET
ZNRI
ACTIVATE SIGNALLING LINK
ZLJC
ZLSU
ZNLI
ACTIVATE SIGNALLING ROUTE SET
ZRDE
ZNVI
ZNGC
ZNHC
LOCAL & REMOTE SUBSYSTEMS
ZNFI; ZNFJ
ACTIVATE LOCAL & REMOTE SCCP
ZNGI
ACTIVATE LOCAL & REMOTE SUBSYSTEMS
ZOBM; ZOBC BROADCASTING
ZNHI
ZOBI; ZOBL
ENDPOINT
ZLJI
UNBLOCK AAL2 PATH
DIGIT ANALYSIS
IP ADDRESS FOR
IP OVER ATM INTERFACE
ZQKC DEFAULT/STATIC ROUTES
ANALYSIS COMPONENTS
ZRDC
ZNVC
ZNFD
Iu-PS
INTERFACE
?
ZOYC
ZNCS
ZNPI
MTP SERVICES
ZRIL
ZRII
Create first IP interface, IP
address and routing
ZQRI
ZQKB