Optical Meter Relays/
Self-Contained - K Series.
K Series (Compack I & II)
Models: 303-K (3 / "), 503-K (4 / "),
603-K (5 / ")
1
UL Recognized with suffix "KU"
Temperature & non-temperature models
Continuous indication
Infinite noise rejection
Easy installation - all connections
at rear terminals
Solid-state circuitry
Single and double setpoints
Rectangular & stackable edgewise models
Customized Scales available
Optical Compack Controllers operate on an optical principle associated with the meter mechanism. A light source (incandescent
lamp) and a photo-resistive cell combination are positioned by the
setpoint mechanism. An opaque vane is attached to the meter
mechanism so that when the indicating pointer reaches the setpoint
the vane intercepts the light from the source, causing a sharp
change in resistance of the photocell. The resistance change is
used to actuate a relay driver circuit for control of an external load.
The response characteristics of D'Arsonval mechanisms automatically provide filtering of the input signal, making Compack Controllers immune to line noise and transient surges. Optical type
controllers are the best choice for applications in electrically noisy
environments.
DC Ranges
K Series Specifications
DC Ranges
Specifications
AC Ranges (Rectifier Type)
Pyrometer
Current
Voltage
Current
Voltage
Accuracy
2%
2%
3%
3%
2%
Tracking
Optional
Optional
Optional
Optional
N/A
Balance
1%
1%
1%
1%
1%
Repeatability
Taut band
Pivot-and-Jewel
Resistance Tolerance
Overload
Capacity
1 Second
< 1/4%
2%
< 1/4%
2%
< 1/4%
2%
20%
5%
1000%
100V 1000%
> 100V 200%
DC Milliamperes
150%
N/A
DC Milliamperes
150%
150%
N/A
60 Hz
60 Hz
N/A
Overshoot (maximum)
20%
20%
20%
20%
N/A
1.5 sec
1.5 sec
1.5 sec
1.5 sec
N/A
3 sec
3 sec
3 sec
3 sec
N/A
Supply Power:
120VAC 50/60Hz standard; 220VAC, 240VAC, 12VDC, 24VDC and 28VDC optional
Load Relay Rating: SPDT 215VA @ 120VAC DPDT Output Relays optional
Made in
the USA
Effects of shock, vibration, humidity and temperature are equal to or better than ANSI C39.1-1981.
Safety (dielectric test, leakage and other hazards): instruments are equal to or better than ANSI C39.5-1974.
The above tolerance limits apply to the standard ranges listed in this bulletin. Special instruments may vary from these limits.
Rated circuit to ground voltage = 250 Vrms (350 Peak) except 50VDC on Pyrometer models.
K Series Dimensions
Model
Height
Width
Depth*
3.13
3.28
5.50
503-K (4 1/2")
4.27
4.71
5.50
603-K (5 1/2")
4.36
5.75
5.50
1 to 500
150%
120%
303-K (3 1/2")
5 to 1000
DC Volts
Process Ranges
Response Time Sensitivity 50a
(maximum)
Sensitivity <50a
DC Millivolts
N/A
150%
Dimensions are in inches.
* Depth = front of panel to end of terminals.
See price sheet for part numbers.
Contact Factory for more information & dimensional drawings.
1 to 1000
DC Amperes
< 1/4%
N/A
5 to 1000
use 50mV
external shunt
< 1/4%
2%
< 10V 20%
10V 5%
Calibration Frequency
Continuous
DC Microamperes
DC Volts
1-5
4-20
10-50
1-5
0-10
AC Ranges (Rectifier Type)
AC Microamperes
100 to 1000
AC Milliamperes
1 to 1000
AC Amperes
1 to 50
AC Millivolts
250 & 500
AC Volts
1 to 500
Thermocouple Pyrometer,
RTD Pyrometer, Tachometer
& Frequency Input
Consult Factory