WATER MEA SUREMENT
FROM METERING TO DATA MANAGEMENT
NUBIS
P ROP E LLE R WATE R M E TE R
WI TH H ORI Z ON TAL I M P E LLE R AXLE
MID
VED
P
A PRO
to 2
Nubis is propeller, dry water meter Woltmans type, with horizontal impeller
axle, parallel to pipe axles. Nubis water meters are characterized by modern
construction and technology solutions, which make them long-lasting and
perfectly proved in cooperation with pulse transmitters and remote system
for measuring data readings.
APPLICATION
Water meters are assigned to industrial measurements of water usage up
to 30 degrees of cold water and up to 130 degrees of hot water in relatively
regular and strong flaw rate. Construction of the water meter gives
possibility of mounting on horizontal, vertical and inclined water supply
systems with counter set upwards, sidewards or in medium position H-V.
Optionally, there is available version of water meter for demineralised water
for DN40-150 (cold and hot water) and with the input for pressure sensor
(M14x1,5) for DN50-150.
WATER
MEASUREMENT
WATER METERS
MWN TYPE
WATER METERS MWN TYPE
WITH RADIO MODULE
WITH PULSE TRANSMITTER
WITHOUT PULSE TRANSMITTER
ADVANTAGES
Permanent and efficient construction, ensuring the flow of water in low loss of pressure and easiness in
assembly in random waterworks installations.
Lowered weight of water meter.
Interchangeable and unified metering layer fitting to several sizes of body and assuring optimal water
meter management.
Standard water meter is suitable for remote readings in AMR system.
The possibility of mounting the water meter in the intermediate position without the influence on the
metrological parameters, larger possibilities in designing and modernizing new used water meters
connections.
Very good anticorrosive and mechanical qualities of paint coat (powder paint- epoxy).
CHARACTERISTIC FEATURES
Resistant to the external magnetic field, according to EN14154-3
Low starting slow rate
Wide measuring range
Ease read-out due to a freely adjustable rotary counter dial placed in the casing
Possibility of electronic check-up of the metrological parameters of the water meter
Modular structure
Removable measuring insert in covered casing
Magnetic clutch
ACCORDANCE WITH STANDARDS AND RULES OF LAW
2004/22/EC directive of the European Parliament and the Council of Europe from the March 31 2004
on measuring instruments
PN-EN-14154:2005- Water meters. Part 13
OMIL R49:2004 and 2006- Water meters designed for measuring cold drinking water and hot water
Research certificate WE type- cold water no. SK08-MI001-SMU002, hot water no. SK10-MI001-SMU013
MWN water meters have applied Hygienic Attests (PZH) allowing the product to contact with drinking water
Mechanical classification of environmental conditions - Class M1 - by RMG dated 18.12.2006
Classification of environmental conditions, climate and mechanical - Class B - PN-EN-14154-3: 2005 + A1,
Classification of electromagnetic environmental conditions-Class E1 - by RMG dated 18.12.2006
FROM METERING TO DATA MANAGEMENT
WATER METERS
MWN TYPE
Roller-pointer counter housed, adapted for the radio module,
it co-operates with NK and NO transmitters. The counter
mechanism is equipped with the element of optical data
transition is housed in the plastic airtight casing
Possibility of remote counting
of water volume and low rate
in the AMR system
IP68 counter (only for cold water) co-operates with NK
transmitter and is placed in the copper cover, in the airtight
casing closed with mineral glass
Impulse generating
NK transmitter unit
NO transmitter unit
Rotary set counting mechanism,
360 max rotating angle
In option, material quality
for demineralised water
Double side bearing rotor
unit (hard bearing)
Elements of removable
measuring insert
In option, body of the water
meter equipped with pressure
sensor socket
Table 1. TECHNICAL CHARACTERISTICS
Parameter
MWN, MWN-XX
Nominal diameter
DN
WODOMIERZE
TYPU MWN
Temperature class
(Working temperatures range)
mm
40
50
T30 (0,130C),
T50 (0,150C)
65
80
100
125
150
200
250
300
MWN (without transmitter)
or MWN (with transmitter) in NK, NO, NKO, NKOP optio
Constant flow rate
Q3
m3/h
25
40
63
100
160
250
400
630
1000
1600
Overload flow rate
Q4
m /h
31,25
50
78,75
125
200
312,5
500
787,5
1250
2000
Transitional flow rate
Q2
m3/h
0,4
0,64
0,806
1,28
2,5
3,2
8,064
16
20,48 25,6
Minimal flow rate
Q1
m3/h
0,25
0,4
0,504
0,625
0,8
1,563
5,04
10
12,8
Starting flow rate
m3/h
0,15
0,15
0,2
0,25
0,25
0,5
1,0
1,5
R measuring rate
Q3/Q1
100
100
125
160
200
160
200
125
100
Coefficient
Q2/Q1
16
8
125
100
1,6
Temperature class
(Working temperatures range)
T130
(0,1130C)
Constant flow rate
Q3
m3/h
25
25
40
63
100
160
250
400
630
1000
Overload flow rate
Q4
m3/h
31,25
31,25
50
78,75
125
200
312,5
500
787,5
1250
Transitional flow rate
Q2
m3/h
1,6
2,52
6,4
10
16
40,32
64
Minimal flow rate
Q1
m3/h
0,625
0,625
1,575
2,5
6,25
10
25,2
40
Starting flow rate
m /h
0,25
0,25
0,3
0,35
0,6
1,1
15
R measuring rate
Q3/Q1
40
40
40
40
40
40
40
40
25
25
Coefficient
Q2/Q1
MWN (without transmitter)
or MWN (with transmitter) in NK, NO, NKO, NKOP optio
1,6
Clase de resistencia al perfil de caudal
Indication range
m3
106
Accuracy of indication
m3
0,0005
Upper pressure limit
Pmax
U0, D0
107
0,005
MAP16=(16bar)
Working pressure range
bar
from 0,3 to 16
Max pressure lost
kPa
P16=(0,16bar)
Working position
H, V
5% (Q1QQ2)
2 (Q2QQ4) for 0,1T30C
3 (Q2QQ4) for T>30C
Border range error allowed
NK Reed Switch pulse transmitter
dm3/
imp.
1000 (standard impulsion)
2,5; 10; 25; 100; 250
Optoelectronic impulse transmitter NO**
dm3/
imp.
mm
Dimension
Weight
0,05
200
200
200
10000 (standard impulsion)
25; 100; 250; 1000;
2500;
250; 1000;
2500;
10
105,2632
225/200***
250
250
300
350
450
500
mm
65
72
83
95
105
120
135
160
193
230
mm
177
187
197
219
229
257
357
382
427
497
H1****
mm
227
287
297
239
349
377
582
607
652
722
DZ
mm
150
165
185
200
220
250
285
340
400
460
7,9
9,9
10,6
13,3/13,8***
15,6
18,1
40,1
51,1
75,1
103,1
8,3
10,3
11
13,7/14,2***
16
18,5
40,5
51,5
75,5
103,5
without transmitter
with transmitter NK | NO
kg
*) Quality: NK- Reed Switch transmitter, NKP- water meter adapted for Reed Switch,
NO- optoelectronic transmitter, NKO- optoelectronic and Reed Switch transmitter,
KNOP- water mater adapted for optoelectronic and Reed Switch transmitter.
**) Only for T30 and T50.
***) On request.
****) Space for measuring insert removal.
TFlange drilling according to PN-EN 1092-2 (PN10), DIN2532, DIN2501 (NP10), BS4504
(NP10) on special request PN16 and PN25 quality for chosen sizes.
FROM METERING TO DATA MANAGEMENT
HEAD LOSS DIAGRAM
WATER METERS
MWN TYPE
TYPICAL ERROR DIAGRAM
CONNECTION EXAMPLES FOR IMPLEMENTATION REMOTE INDICATION TRANSMITTING
AND MEASURING THE FLOW RATE
Impulse converter
(placed on a rail)
Transmitter
Impulses
NK; NO
NK
W1
Programmed gauge
Us<24V; I 5 to 15mA (max. 50mA)
Wire YTLY 2x0,25 mm2 L=2m
Water meter
Transmitter
N0
Brown
Green
White (GND)
(placed on a panel)
Impulses
NK; NO
Is
I0
Us - 5 to 24V DC; U0 -NPN OC;
Is < 30 mA (I0 = mA)
Wire LiYY 3x0,25mm2 L=2m
U0
P12 O
4-20 mA (in Q function)
Alarm 1
Alarm 2
RS 485 Modbus
W1
US
N30 O
Impulse counter
Impulses
NK; NO
Radio module
Frequency range - 868 Mhz
Protocol- Wireless M-Bus
Output power - 10 mW
W1
W2
W3
AMR
System
Order example:
Water meter for cold water: ex. MWN 50-NO or MWN 80-NK (1 dm3/imp) etc.
Water meter for hot water: ex. MWN 130-100-NK (25 dm3/imp)
When ordering one should assess other data than the standard ones ex.: impulse value,
Quality (ex. for demineralised water) or flange drilling described earlier.e.
IZM
MULTIPULSE
Collectors data
reading
Stationary data
reading
4-20 mA (in Q function)
Alarm 1
Alarm 2
RS 485 Modbus
RS232
(RS 485)
(M-bus)
RS OPTO
PC
CSV, TXT
Apator Powogaz S.A.
Klemensa Janickiego 23/25, 60-542 Pozna, Poland
e-mail:
[email protected]Secretary office: tel. +48 61 8418 101, fax +48 61 8470 192
Sales department: tel. +48 61 8418 133, 136, 138, 148
Export department: tel. +48 61 8418 139
SWITCHGEAR
WATER
MEASUREMENT
HEAT
MEASUREMENT
MINING
EQUIPMENT
GAS
MEASUREMENT
AUTOMATION
SENSORS
www.apator.eu
IT SYSTEMS
METERING
SOLUTIONS
EN.00045 | 2011
ELECTRICITY
MEASUREMENT
SURGE
ARRESTERS