M50PSC Concrete Mix Design Summary

This document summarizes four concrete mix design trials for a six-laning highway project in Andhra Pradesh. Trial IV best met specification requirements. It used 500 kg/m3 of cement, a water-cement ratio of 0.35, 500 kg/m3 of coarse aggregate, 620 kg/m3 of sand, and 1.2% admixture. It achieved the target compressive strengths of 35.02 MPa at 3 days, 50.37 MPa at 7 days, and 66.12 MPa at 28 days. The trial IV mix was determined to be the most cohesive.

Uploaded by

Çhårū Kêsh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views2 pages

M50PSC Concrete Mix Design Summary

This document summarizes four concrete mix design trials for a six-laning highway project in Andhra Pradesh. Trial IV best met specification requirements. It used 500 kg/m3 of cement, a water-cement ratio of 0.35, 500 kg/m3 of coarse aggregate, 620 kg/m3 of sand, and 1.2% admixture. It achieved the target compressive strengths of 35.02 MPa at 3 days, 50.37 MPa at 7 days, and 66.12 MPa at 28 days. The trial IV mix was determined to be the most cohesive.

Uploaded by

Çhårū Kêsh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

National Highways Authority of India

Project: Six laning of Chilkaluripet - Nellore section of NH-5 from km 1182.802 to km 1366.547 (length-183.620 km) in the State of Andhra Pradesh under NHDP Phase
project on DBFOT Pattern.
Section : 1 A , 1182+802 Km to 1251+000 Km
Concessionaire : Simhapuri Expressways Limited
EPC : -BSCPL Infrastructure LTD.

Independent Engineer : ICT & SNC LAVA


PMC: Feedback Ventures

CONCRETE MIX DESIGN TRIAL SUMMARY


Grade of Concrete : M50PSC
Brand of Cement : Jaypee OPC 53 grade
Coarse Aggregate : BSCPLIL Crusher, Bodduvanepalem

Fine Aggregate :Crushed Stone Sand (Wa


Admixture : FAIRFLO RMC M,FAIRMATE

SL.N
O.

Type of material

Trial No.I

Trial [Link]

Trial [Link]

Trial [Link]

Cement (Kg/m3)

490

490

490

500

W/C

0.40

0.40

0.35

0.35

Water (Kg/m3)

196.0

196.0

171.5

175.0

16 mm (Kg/m3)

638.2

666.7

660.6

683.5

10 mm (Kg/m3)

638.2

666.7

660.6

683.5

Sand (Kg/m3)

662.3

604.7

685.6

620.0

Admixture (%)

0.80

1.00

1.20

1.20

Initial Slump (mm)

140

150

170

180

Final Slump after 60min. (mm)

65

75

140

145

10

Final Slump after 90min. (mm)

50

60

80

90

11

3 days Target compressieve Strength (N/mm2)

30.44

31.26

33.84

35.02

12

7 days Target compressieve Strength (N/mm2)

44.58

45.44

48.29

50.37

13

28 days Target compressieve Strength


(N/mm2)

59.66

60.43

64.59

66.12

14

Observations

Required Slump & Strength Required Slump achieved,


Required Slump & Strength
Required Slump & Strength
not achieved, Mix is not
Strength not achieved, Mix
achieved, mix is more
achieved, mix is cohesive
much cohesive
is not much cohesive
cohesive

Remarks:- Trial-IV is conforming to the specification Requirements.


For The Contractor

For The Concessionaire/PMC

For The Independent Engineer

r NHDP Phase V to be executed as BOT (Toll)

T & SNC LAVALIN (JV)


ck Ventures

Stone Sand (Washed)


C M,FAIRMATE,Chennai
Specification
Requirements

Remarks

_
Max.0.40
_
_
_
_
_
_
_
75-125
31.50
47.25
63.00

For The Contractor

For The Concessionaire/PMC

For The Independent Engineer