A E R A
D E S I N G
P R O D U C T I O N
&
D I S T R I B U T I O N
2012
PRODUCT OVERVIEW
Aera creates comfortable, pleasant and healthy indoor
air for all kinds of buildings and for all kinds of interiors.
PRODUCT OVERVIEW
Summary
Air Handlng Units
Heat Recovery Units
Cooling Technique
Air Regulation Units, Sound Attenuators
Fans
Air Distribution Components
Kitchen Hoods
Clean Room Components
Fire Protection Components
Heating And Cooling Units
Solar Systems
APPLICATION
AERA air handling units are used for
central air conditioning on office
buildings, hotels, restaurants, theatres
and sport facilities, hospitals, indoor
swimming pools, industrial applications, clean rooms and other buildings.
AIR HANDLING UNITS
Standard XTA
CHARACTERISTICS
AERA air handling units support all basic air
conditioning functions: heating, cooling,
filtration, humidification, dehumidification,
recuperation and regeneration.
We manufacture several sizes of air conditioning units with volume air flow of
500mc/h to 120.000 mc/h
AERA air handling units are distinguished by
excellent thermal and sound insulation
AERA air handling units allow a customized
selection of function elements with high
utilization rates
A modern construction enables dimensional
adaptability
Ceiling XTA
TYPES, VERSIONS
Standard XTA with 50mm wall thickness
indoor version
outdoor version
swimming pool version
hygienic version
version for heating and ventilation of
overpressure halls
Ceiling XTA
with 15mm wall thickness
Standard XTA with 25 mm wall thickness
indoor version
CleanPack PHK NEW 2011
designed especially for health sector and
clean room applications
standard equipment: frequency-regulated
fans, AISI 304 stainless steel sheet cased
hot eater coil, build-in direct expansion
refrigeration system, built-in humidifiers,
electrical heater for dehumidification, heat
recovery circulation pump, built-in microprocessor for processes control, temperature and humidity control
we manufacture 7 sizes with volume air flow
of 2000 mc/h to 10.000mc/h
CleanPack PHK
RECUPERATION
AERA air handling units allow users to
select an optimal system for heat or
cold recuperation from waste air:
AIR HANDLING UNITS
plate recuperator system
rotary recuperator system
system with two heat exchangers
connected to a tube circuit strip recuperator
Recuperator
heat tube system
heat pump system
AUTOMATIC CONTROLS
In process of air handling unit selection, we
use Aircalc software which is also an excellent
tool for the planning of air conditioning
systems as it makes calculations as well as
produces sketches than can be exported to
AutoCAD, textual descriptions and thermodynamic process charts in the form of Molier h-x
diagram.
AERA SOFTWARE WILL ALLOW TO:
Automatic Controls
select and determine the different unit
configurations in relation to the plant
parameters, the performances required and
the limitations imposed by the customer
elaborate a diagram of the handling unit,
essential and complete, as support to the
choices made
supply preliminary costs to support the best
choice in terms of performance/quality/price
integrate the preliminary data and elaborate
execution diagrams and components list to
support the production of the unit
AERA Selection Software
HRE - Heat recovery units for
residential sector, efficiency > 90%
Q = 350 m3/h and 500 m3/h
HEAT RECOVERY UNITS
Compact panel 25 mm
Filtration G4/ F7
Vertical or horizontal installation
With or without automatic by-pass
HEAT RECOVERY UNITS FOR RESIDENTIAL SECTOR
Electrical or water heater (duct)
Plugnplay unit
Various accessories
RHU 150 - Heat recovery units for
residential sector, efficiency > 90%
Q = 150 m3/h
Compact panel 25 mm
Filtration G4/ F7
HRE
RHU150
Vertical or horizontal installation
With or without automatic by-pass
HEAT RECOVERY UNITS FOR TERTIARY SECTOR
Electrical or water heater (duct)
Plugnplay unit
Various accessories
DSHR - Heat recovery units for tertiary
sector, eff. 50 - 70%
Q = 400 5.600 m3/h (6 models)
Double skin unit, 25 mm
Filtration G4/ F7
Vertical or horizontal installation
With or without automatic by-pass
El. (2-12kW) or HW heater (2,62-34,5 Kw)
Plugnplay unit
Various accessories
DSHR H Heat recovery units for tertiary
sector, eff. 50 - 70%
Q = 400 5.600 m3/h (6 models)
Double skin unit, 25 mm
Filtration G4/ F7
Vertical or horizontal installation
With or without automatic by-pass
Electrical (2-12kW) or water heater (2,6234,5 Kw) INTEGRATED
Plugnplay unit
Various accessories
DSHR
DSHR-H
LCHR - Heat recovery units for
tertiary sector, eff. 50 - 70%
Q = 400 3.500 m3/h
Low casing unit, 10 mm
Filtration G4/ F7
Vertical or horizontal installation
With or without automatic by-pass
Electrical (2-8 kW) or water heater (3,1621,86 kW)
Plugnplay unit
Various accessories
HHR-BP, VHR-BP - Heat recovery units for
tertiary sector, eff. 50 - 70%
Q = 4.500 12.000 m3/h (3 models)
Double skin unit, 25 mm
Belt and pulley transmission
Filtration G4/ F7
Vertical or horizontal installation
With or without automatic by-pass
Electrical (12-60 kW) or water heater
(20,1-60,6kW)
Plugnplay unit
AVAILABLE OPTIONS
VAV variable air flow
CAV constant air flow
COP constant pressure
Various accessories
RHR-T, RHR-E - Heat recovery units for
tertiary sector, eff. 75 - 86%
Q = 1.000 5.000 m3/h (5 models)
Double skin unit, 40 mm
ROTARY heat exchanger
Filtration G4/ F7
Vertical or horizontal installation
With or without automatic by-pass
Electrical (4-12 kW) or water heater (by
project)
R410 Direct Expansion coil (5,5 kW-28 kW)
AVAILABLE OPTIONS
VAV variable air flow (E)
CAV constant air flow
COP constant pressure
Constant rotation of exchanger
Variable rotation of exchanger
Various accessories
HEAT RECOVERY UNITS
HEAT RECOVERY UNITS FOR TERTIARY SECTOR
LCHR
RHR-T, RHR-E
HHR-BP, VHR-BP
XHR-T, XHR-E - Heat recovery units
for tertiary sector, eff. 85 - 93%
Q = 1.000 6.000 m3/h (6 models)
HEAT RECOVERY UNITS
Double skin unit, 40 mm
Counter flow heat exchanger
Filtration G4/ F7
Vertical or horizontal installation
HEAT RECOVERY UNITS FOR TERTIARY SECTOR
With or without automatic by-pass
Electrical (4-16 kW) or water heater (5,54
kW-30,98 kW)
R410 Direct Expansion coil (5,5 kW-30 kW)
AVAILABLE OPTIONS
VAV variable air flow (E)
CAV constant air flow
COP constant pressure
Various accessories
HPRU - Heat pump recovery units for
tertiary sector
Q = 1.500 m3/h, 2.500 m3/h, 3.500 m3/h
Double skin unit, 25 mm
Cross flow heat exchanger
Filtration G4/ F7
Horizontal installation
EXCELLENT SOLUTION FOR RENOVATIONS
Operating temperature from 7-35 dgrs
1 speed or 2 speed (INVERTER) direct driven
fans
Total cooling/heating power and EER/COP:
HPRU 15: 10,1 kW, EER 3,4 / 12,6 kW, COP 4,7
HPRU 25: 15,8 kW, EER 3,4 / 20,7 kW, COP 5,3
HPRU 35: 21,1 kW, EER 3,6 / 26,2 kW, COP 5,2
16 different configurations available
XHR-T, XHR-E
HPRU
CHILLERS AND HEAT PUMPS
Energy efficient air cooled and water
cooled hydronic units and heat pumps
COOLING TECHNIQUE
Types, Capacity
AIR/WATER CHILLER Air cooled water
chillers with energy class A, 6-684 kW
AIR/WATER FREE-COOLING CHILLER Air
cooled water chillers with integrated free
cooling 45-523kW
AIR/WATER
MULTIFUNCTIONAL UNITS
AIR/WATER FREE-COOLING
CHILLER
AIR/WATER CHILLER
WATER/WATER CHILLER
AIR/WATER HEAT PUMPS
WATER/WATER HEAT PUMPS
AIR/WATER MULTIFUNTIONAL UNITS Air
cooled multifunctional hydronic units with
cooling and heating simultaneously and
independently from each other 33-227kW
WATER/WATER CHILLER Water cooled water
chillers with energy class A, 6-46 kW
AIR/WATER HEAT PUMPS Air cooled water
heat pumps with energy class A, 7-64 kW
WATER/WATER HEAT PUMPS Water cooled
water heat pumps with energy class A
6-87kW
HYDRONIC MODULE Advanced hydronic
module
HYDRONIC MODULE
PROTECTION LOUVRES
Protection louvres are installed in
building fronts (in supply and exhaust
air openings) as a protection against
the direct ingress of rain, birds, bigger
insects etc. They are suitable for all low
pressure air conditioning, heating and
ventilation. They are made of galvanized
steel or aluminum in numerous standard or
special dimensions, stainless steel version also
available.
AIR REGULATION UNITS,
SOUND ATTENUATORS
PROTECTION LOUVRES
SUPPLY AIR/EXHAUST TOWERS
Air towers are used for the supply and exhaust
of air. Various construction types can be made
of different materials and in different dimensions according to the customers request.
GL50
GL100
GL150
CEG
OVERPRESSURE DAMPERS
Overpressure dampers are used to equalize
the pressures between adjacent rooms and for
automatic interruption of air supply or air
exhaust . Steel or aluminum overpressure
dampers can be produced.
OVERPRESURE DAMPERS
OVD100
SUPPLY AIR/EXHAUST TOWERS
SEAT
VOLUME CONTROL DAMPERS
Volume control dampers regulate the
air flow volume in ventilating ducts air
conditioning devices. We produce
several construction types with
manual, motor or pneumatic regulation.
THROTTLING, SHUT OFF AND NON RETURNING DAMPERS, FLOW RATE CONTROLLERS
AIR REGULATION UNITS,
SOUND ATTENUATORS
MULTILEAF DAMPERS
They are used to control the air flow volume in
ventilating ducts.
MLD50Z
MLD100A
MLD150A
MLD200Z
CDET
MLD-T-200Z
VFR1
VFR2
CFR-1
CFR-2
AIR TIGHT DAMPERS
VAV UNITS
SOUND ATTENUATORS
Sound attenuators are designed to
quiet fan and air-conditioning device
noises in ventilating ducts and to
prevent propagation of noise between
rooms.
Sound attenuators RSA
RSA sound attenuators field of application is
the attenuation of fan noise in ventilation and
air-conditioning installations. They provide very
efficient attenuation on the 250 TO 4000 Hz
frequency range. The splitters built in these
attenuators consist of alternant layers of
absorbing material and galvanized steel sheet
membranes.
AIR REGULATION UNITS,
SOUND ATTENUATORS
SOUND ATTENUATORS
CSA-1
CSA-2
RSA
AB
Sound attenuators CSA -1
CSA -1 round sound attenuators are applied in
ventilation and air-conditioning systems for
attenuation of fan noises. They are suitable for
installation in either inlet or outlet pipes of
axial fans, in inlet pipes of radial fans or
installation in circular cross-section ducts.
Sound attenuators CSA -2
CSA-2 round sound attenuators prevent
propagation of noise between rooms through
ventilation ducts
SOUND ATTENUATING LOUVRES
ACOUSTIC LOUVRE AL
Acoustic louvres AL are designed to prevent
ingress of outside noises into the building
interior or propagation into the environment,
though supply or exhaust openings . In
addition to their acoustic protection function,
they also serve as conventional protection
louvres.
AL
ROOF FANS
Specially designed for roof installation,
they are suitable for:
smoke extraction
smoke emergency exhaust with
motor outside the hazardous area
(400oC/2h certificate)
air renewal in buildings and industries
industrial and professional kitchen hoods
FANS
ROOF FANS
IN_LINE AND IN SOUNDPROOF
AXIAL FANS
MEDIUM AND HIGH PRESSURE
COM-VENT
DOMESTIC RANGE
IN-LINE AND IN SOUNDPROOF BOXES
Designed for inline installation, indoor and
outdoor assembly, they are suitable for:
air renewal in buildings and industries
air renewal in bathrooms and small enclosed
environments
perfect for installation in dropped ceilings
AXIAL FANS
Designed for inline installation, they are
suitable for:
air renewal in buildings and industries
smoke extraction (max 50-60oC)
general ventilation in enclosed environments
classified as ATEX zone 1 or 2
MEDIUM AND HIGH PRESSURE FANS
Designed for inline installation, they are
suitable for:
corrosive air transport
chemical and petrochemical industry
laboratories and gas cabinets
maximum working temperature: 50oC
COM-VENT Constant pressure fan unit
Range 3 models for collective MVHR
Panel construction, 25 mm
Q = 600 5.600 m3/h
Static pressure up to 700 Pa
Inverter driven centrifugal fans
Various PLUGNPLAY options (COP, PID...)
Operating range from -20 to +60oC
DOMESTIC RANGE
Axial fan for exhaust ventilation with a capacity
up to 292m3/h.
casing and impeller made of high quality
durable ABS plastic, UV resistant.
the fan is equipped with a back draft damper
for back flow preventing.
ultra thin front panel (8mm).
protection rating IP 34.
VENTILATING GRILLES
Ventilating grilles are designed for all
types of low-pressure airconditioning, heating and ventilation
systems with built in air flow and throw
distance control as well as regulation
of discharge angle. They can be used for
both supply air and exhaust air applications.
AIR DISTRIBUTION
COMPONENTS
ALUMINIUM GRILLES
Aluminum grilles
Aluminum grilles are made of extruded AL
sections anodized in natural aluminum color.
Upon customer request they can be anodized
in other colors or powder painted.
AG
RG
AWG
AEG
GL20
TG
FG20
RFG20
IG
RDG
Steel grilles
Steel grilles are made if sheet steel and
powder painted un RAL9010 or RAL9016.
Upon costumers request they can be made of
galvanized or stainless steel, respectively other
RAL colors are possible upon request.
VENTILATING VALVES
Steel ventilating valves are made of sheet steel
colored with powder coating in RAL9010 or
RAL9016.
Upon customers request other RAL colors are
possible.
STEEL GRILLES
VENTILATING VALVES
EV&SV
CIRCULAR DIFFUSERS
Circular diffusers can be used for
supply or extract air. Due to height
induction ( mixing of supply and room
air) they are suitable for larger
temperature differentials between the
supply and room air. Diffusers have high
capacity and low sound power level.
AIR DISTRIBUTION
COMPONENTS
CIRCULAR DIFFUSERS
ALUMINUM DIFFUSERS RCA, RCD
Diffusers rings are made of sheet aluminum
and regulation mechanism consist of steel.
Diffuser is powder coated in RAL9010. Upon
customers request, they can be colored in any
RAL color.
RCA
RCA IN PLATE
SQUARE DIFFUSERS
Square diffusers are designed for supply and
extract air. Due to high induction (mixing of
supply and room air) they are suitable for
larger temperature differentials between the
supply and room air. Diffusers have high
capacity and low sound power level.
RCD
ALUMINUM AND SHEET STEEL DIFFUSERS
MWD, PD
They consist of aluminum or sheet steel,
powder coated in RAL9010. Upon costumers
request, they can be colored in any RAL color.
Plenum box is made of galvanized sheet steel.
SQUARE DIFFUSERS
MWD123
MWD4
MWD4 IN PLATE
PD
SWIRL DIFFUSERS
Application:
Swirl diffusers are designed for
air-conditioning of room with floor to
ceiling heights from 2,5 to 4m and
temperature difference between supply
and room air of +10K to -10K. Due to the
rotary swirling motion of the air discharge,
induction of room air occurs very quickly. Swirl
diffusers are suitable both for comfort as well
as industrial air conditioning.
AIR DISTRIBUTION
COMPONENTS
SWIRL DIFFUSERS
Description:
Swirl diffusers consist of plenum box made of
galvanized sheet steel and front plate. Front
plate is made of sheet steel or aluminum
powder painted in RAL9010 or any RAL color
upon customers request.
MSD
MCSD
RSD
DVSE
MCSD-2
RSD-2
VARIABLE SWIRL DIFFUSERS
Application:
Variable diffusers are designed for rooms with
changing thermal loads which require different
conditioning ( heating, cooling). They are
suitable for rooms with floor to ceiling height
of up to 10m and recommended temperature
difference between supply and room air + 10K
to 10K. Required conditioning is achieved by
the means of manual or powder driven blades
adjusting. Variable diffusers are suitable for
both comfort and industrial conditioning.
Description:
Variable diffusers consist of plenum box made
of galvanized sheet steel and diffuser. Diffusers are made of sheet steel or sheet aluminum
and powder painted in RAL 9010 or RAL9016
color upon customers request.
VSD T
VARIABLE SWIRL DIFFUSERS
At VSD-T diffuser, centrally adjustable blades
can be adjusted automatically with the
thermostat regulation. Thermostat perceives
temperature of the supply air and automatically adjusts the blade angle.
VSD
SLOT DIFFUSERS.
Slot diffusers are designed for air
supply n rooms with floor to ceiling
heights of 2.5 to 4m. They are suitable
for supplying either cold or warm air, in
particular in applications where air
conditioning comfort demands are
stringent. Due to their high induction rate
and rapid decrease of temperature difference,
the diffusers are also suitable for variable
systems.
AIR DISTRIBUTION
COMPONENTS
SLOT DIFFUSERS
ROUND DUCT DIFFUSERS
Round duct diffusers can be installed at various
locations within the duct network. They are
suitable for supplying wither cold or warm air.
LD
PLENUM BOX
ROUND DUCT DIFFUSERS
CYSD
AIR DISPLACEMENT UNITS
Air displacement units are suitable for
both industrial and comfort air conditioning applications. They are suitable
for rooms characterized by high heat
loads or heavy air pollution. Air
displacement units supply air at large
flow rates ( up to 10.000mc/h), at low air
velocities ( in range of 0,1 to 0,3 m/s).
AIR DISTRIBUTION
COMPONENTS
AIR DISPLACEMENT UNITS
Types:
ADU-1 : Corner
ADU-2 : Semi-cylindrical
ADU-3: Cylindrical
ADU-4: Rectangular
SUPPLY AIR NOZZLES
Supply air nozzles are designed to supply air
into rooms in applications requiring large
throw distances and low noise levels. They are
suitable for supplying either cold or warm air.
They are made of anodized sheet aluminum.
On request, they can be powder painted in any
RAL scale colors or stainless steel. Air supply
nozzles are supplied as a single piece component or assembled into blocks, which considerably increase throw distance.
ADU-1
ADU-2
ADU-3
ADU-4
SUPPLY AIR NOZZLES
JET1
JET2
JET3
KITCHEN HOODS
Ventilation of kitchens involves exhaust
and discharge of increased temperature air, full of moisture, steam, gases
or odours. The exhausted quantity of
air has to be replaced by fresh, and if
necessary, preheated air. There are two
types of exhaust kitchen hoods: conventional exhaust hood and energy-saving
exhaust hood. Compared to conventional
exhaust hood, energy-saving exhaust hood
operates with 70% of fresh, unheated air
supplied to the hood by means of a separate
fan and a duct. Within the hood the supply air
is fed to the adjustable jet-profiled slot through
which it is discharged at increased velocity
towards exhaust filters
KITCHEN HOODS
CONVENTIONAL EXHAUST HOODS
NZR
ENERGY-SAVING HOODS
GRASE TRAP FILTER FM
Grease trap filters are used in ventilation
systems of canteens, kitchens and similar
places. Their main purpose is prevention of
grease accumulation in ventilation ducts and
fans. Filter inserts are made of expanded
aluminum sheets
NES
GRASE TRAP FILTER
FM
NSP
DUCT PRE-FILTERING UNIT - BNC
Duct pre-filter units are designed to
clean the air in air-conditioning and
ventilating systems. It can house pre
filters, rigid bag, absolute and activated
carbon filters. The access to the filter
holder is possible through the frontal
door. It is equipped with flanged rectangular connections; it is available also in the
double face execution for two filter elements.
DUCT FILTER UNITS - DFM
Anti-contamination safety multi bank for
dangerous substances equipped with collectors.
It is composed of two or more parallel multistage banks; each of them can house pre filters,
rigid bag, absolute, activated carbon filters. The
access to the filter holder is possible through
the frontal door, while the removal of the filter
element is done under the barrier bag (attached
instructions). It is equipped with flanged
rectangular connections; it is available also in
the double face execution for two filters
elements.
CLEAN ROOM
COMPONENTS
DUCT PRE-FILTERING UNIT
DUCT FILTERING UNIT
BNC
DFM
DUCT HOUSING FILTER UNITS
DUCT HOUSING FILTER UNITS MULTI DFM
Duct housing for absolute filters and pre filters.
It is equipped with two housings: one for filters
with thickness 48 mm and one for absolute
filters. Thanks to its modularity and easy
installation, which can be with vertical or
horizontal flow, it can be used both in new
construction and in old plants, where higher
filtration efficiency is required.
FILTER DIFFUSER - SIMPLAIR
Mini pleat filter diffuser is composed of a
laminar flow filter coupled with a circular inlet
plenum with efficiency class from E10 to U15
(according to EN 1822:2009). It is commonly
used in air controlled contamination environments, also in critical applications such as clean
rooms with laminar flow
FAN FILTERING UNITS (FFU) - VENTILAM
Fan filtering units are composed of a laminar
flow filter class H14 according to EN 1822:2009
(Eintegral 99,995% - Elocal 99,975%)
coupled to a centrifugal fan with electronic
regulation of the air flow. It is commonly used
suspended from the ceiling to create a
contamination-controlled area below. The
standard electronics offers the following
features:
control panel with LCD display for checking
the status of the unit, supplied with cable
(3mt. length) for remote.
setting of 3 levels of scale (1/3, 2/3, 3/3 of
nominal value) with automatic compensation
following pressure drop increase
Filter change alarm (LED + contact)
Several customizations are possible.
MULTI DFM
FILTER DIFFUSER
FAN FILTERING UNITS
SIMPLAIR
VENTILAM
HEPA FILTER TERMINAL
- HEPA BOX FT-HE
Terminal filter diffuser lightweight and
easy to install, it can house mechanical
gasket and also fluid seal gasket. It can
be equipped with numerous types of
diffusers.
Housing is epoxy-painted galvanized steel
thickness 1,0mm; special thickness 1.5mm
for filter tight though screw device for absolute
filter thickness 68,150, 292 mm. Serration
filter though non-deflecting angles in stainless
steel ; pressure measurement points from side
or front part; leakage test in according with EN
1886 They are commonly used in controlled
contamination environments such as air
distribution system terminals
OPERATING THEATRE FILTERING UNITS
- PLAFOND
PLAFOND OTC-HE
Modular filtration unit with vertical laminar
flow, with uniform velocity on the whole
exhaust section. It has been especially studied
for hospital applications, with ceiling installation over the operating table with predisposition for scialytic light. Eight size available
suitable for airflows from 2100mc/h to
12300mc/h. They are made of galvanized steel
painted RAL9010 as standard equipped with
pressure taps. Upon customers request,
version INOX 304 is also available.
PLAFOND SC-HE
Modular filtration unit with vertical laminar
flow, with uniform velocity on the whole
exhaust section. It has been especially studied
for hospital applications or sterile rooms, with
ceiling or wall installation. Nine size available
suitable for airflows from 1330mc/h to
9600mc/h. They are made of galvanized steel
painted RAL9010 as standard equipped with
pressure taps. Upon customers request,
version INOX 304 is also available.
WALL FILTERING UNIT WFU
Wall filtering units WFU are used for supply of
clean air into the sterile rooms systems. High
technology assembly casing in combination
with the most sophisticated HEPA filters H13
(99,95% MPPS) or H14 (99,995% MPPS) is a
guarantee for operation of the WFU in accordance with the EN ISO 14644-1. Air velocity of
the supply air is from 0,30 0,50 (min/max) at
the distance of 20 cm from the air outlet.
Special modular construction of the WFU is
enabling use of high efficiency filtering units in
the systems, where the height of the sterile
rooms ceiling does not allow the use of ceiling
filtering modules.
They are made of galvanized steel painted
RAL9010 as standard equipped with pressure
taps. Upon customers request, version INOX
304 is also available.
CLEAN ROOM
COMPONENTS
HEPA FILTER TERMINAL
FT-HE
FT-HE
OPERATING THEATRE FILTERING UNIT
PLAFOND OTC-HE
OPERATING THEATRE FILTERING UNIT
PLAFOND SC-HE
WALL FILTERING UNIT
WFU
PERFORATED FILTER GRILLE PFG
The return grilles are suitable for the
return air in the hospital or laboratories. High efficiency filter terminals are
used in hospital or pharmaceutical
applications, as well as in projects with
fine dust aspiration. They are made of
galvanized steel painted RAL9010 as
standard equipped with pressure taps. Upon
customers request, version INOX 304 is also
available
CLEAN ROOM
COMPONENTS
PERFORATED FILTER GRILLE
PERFORATED TRANSIT GRILLE PTG20
The transit grilles are suitable for the regulation of the flux air in the hospitals or laboratories. High efficiency transit grilles are used in
hospital or pharmaceutical applications, as
well as in the projects where fine flux regulation is required. They are made of galvanized
steel painted RAL9010 as standard. Upon
customers request, version INOX 304 is also
available.
PFG
PERFORATED TRANSITGRILLE
HEPA & ULPA FILTERS
AERA Hepa and Ulpa filters are specially
designed for use in clean rooms and precision
assembly areas.
They come in a wide range of sizes for use in
stat many applications. They can also be used
as final filtration filters in applications with
purification filters. The filtration medium
consists of highly efficient micro porous
polyurethane minipleats held in place by
strong, rigid plastic separators that keep the
medium from nesting. This design channels air
flow with optimal efficiency to reduce resistance. The filter is sealed into the sturdy
aluminum o MDF frame.
PTG20
HEPA & ULPA FILTERS
HEPAFIL 69150
HEPAFIL 292
FIRE DAMPERS
Fire dampers are installed in rectangular
or circular ventilation ducts at passages
of fire compartments. In case of fire, fire
dampers close automatically, thus
preventing fire from spreading through
the ventilation ducts. Fire resistance 120
minutes.
FIRE PROTECTION
COMPONENTS
FIRE DAMPERS
Types according with release mechanism:
basic type with fusible link release
motorized type with electric actuator
SMOKE DAMPERS
Smoke dampers open automatically in case of
fire and this enable the exhaust of smoke and
heat. Fire resistance 90 to 120 minutes.
Types according with the release mechanism:
FD3-E
FD12-C
FD150Z
FD-D
basic type with fusible link
solenoid type
SMOKE DAMPERS
motorized type with electrical actuator
FAN COIL
Application and operation
Fan coils are devices designed for room
air-conditioning purposes their functions
include heating, cooling, ventilation and
to certain degree, air-drying. They are
suitable for many applications: business
centers, hotels, shops etc. Their operation
involves forced convection of the air.
Types and designs
Our production includes a broad range of types
and designs:
for two-pipe our four-pipe systems
visible designs (parapet, wall or ceiling
mounting)
horizontal or vertical concealed design, with
external static pressure from 50Pa to 250Pa
4 types available with 10 sizes each
Characteristics
high heating and cooling capacities: cooling
capacities from 0.5kW to 23kW and heating
capacities from 0.5kW to 45kW
centrifugal fan with 7 speeds
control with different thermostats and a wide
range of accessories
front metal housing painted in standard
RAL9010; other RAL scale colors are available
on request
ABS discharge grille with adjustable deflectors
easy filter replacement
CEILLING CASSETE UNITS
Application and operation
Ceiling cassette units are devices designed for
room air-conditioning purposes; their functions
include heating, cooling, ventilation and to a
certain degree, air-drying. They are suitable for
many applications: business centers, hotels,
shops etc. Their operation involves forced
convection of the air.
Types and designs
Our production includes:
for two-pipe our four-pipe systems
2 types available: CT 4-way cassette and CS
supply grille cassette
Characteristics
high heating and cooling capacities: cooling
capacities from 2.58kW to 11.57kW and
heating capacities from 3.56 kW to 22.96kW
centrifugal fan with 7 speeds
control with different thermostats and a wide
range of accessories
front metal housing painted in standard
RAL9010; other RAL scale colors are available
on request
ABS discharge grille with adjustable deflectors
easy filter replacement
HEATING AND COOLING UNITS
FAN COIL
ARTO FM
ARTO FMO
ARTO CPR
CEILLING CASSETE UNITS
CELIA CTM
CELIA CS
CELIA CTD
PARAPET CONVECTORS
Application and operation
Parapet convectors are modern
heating terminals designed for heating
of business centers, hotels, shops etc.
They serve either as primary heating
terminals or secondary ones. They are
suitable for application in all rooms with
envelope walls exposed to low exterior
temperatures (large windows or glass walls,
cold walls)
Characteristics
heating capacities from 0.2kW to 12kW
silent operation mode
control with thermostat valve
housing painted in RAL9010, other RAL
colors available on request
easy installation and maintenance
advanced industrial design
FLOOR CONVECTORS FCN,FCF,FCF-R
Application and operation
Floor convectors are modern heating and
cooling terminals. They are designed as a
primary heating and cooling terminals as well
as a secondary ones. They are suitable for
application in all rooms with envelope walls
exposed to low exterior temperatures (large
windows or glass walls, cold walls).Their
operation involves natural and forced convection of the air.
Characteristics
heating capacities from 0.09kW to 10.5 kW
and cooling from 0.4kW to 2kW
silent operation mode
control with thermostat valve
housing painted in RAL9010, other RAL
colors available on request
easy installation and maintenance
HEATING AND COOLING UNITS
PARAPET CONVECTORS
RD
FLOOR CONVECTORS - Natural and forced convection
FCN
FCF
FLOOR CONVECTOR FOR HEATING AND COOLING
FCF-R
INDUSTRIAL FAN HEATERS
INDUSTRIAL FAN HEATERS
Air heaters are devices used for heating,
cooling, ventilation and filtration in various
facilities such as production halls, workshops,
garages etc. They function on the principle of
forced air circulation over a heat exchanger by
means of axial fan.
We manufacture a wide range of models for 2
pipe systems with high heating and cooling
powers.
TAIFUN AT
TAIFUN AT
SOLAR COLLECTORS
Solar collectors are used for heating
sanitary water, water in indoor and
outdoor swimming pools, in greenhouses, for drying agricultural
products, timber and the like as well as
for low-temperature building( floor
warming) or for combined heating with
other energy sources (classical heating
systems, heat pumps)
SOLAR SYSTEMS
FLAT SOLAR COLLECTORS
A solar heating set is consist of:
solar energy collector
support structure for roof mounting
thermal reservoir (heat storage tank)
control elements
pump unit
expansion vessel
Characteristics
high quality of materials
high efficiency
excellent efficiency dire to the coating
modular construction
suitable for horizontal and vertical mounting
long life expectancy up to 30 years
SOLAR SYSTEM SOLA 58/70
SOLA TUBES
We provide a complete range of HVAC systems:
our solutions will fit your unique and custom needs!
Tell us about your project! Call us and order now your free estimate!