7.0 Loop Single - 0

Nortech produces single channel loop detectors that use inductive loops buried under roads to detect vehicle presence. The detectors include the PD130, PD139 and GD100 models. They have diagnostic capabilities, selectable sensitivity settings and output options. A separate DU100 unit is available for extracting detector data.

Uploaded by

tidachin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
421 views2 pages

7.0 Loop Single - 0

Nortech produces single channel loop detectors that use inductive loops buried under roads to detect vehicle presence. The detectors include the PD130, PD139 and GD100 models. They have diagnostic capabilities, selectable sensitivity settings and output options. A separate DU100 unit is available for extracting detector data.

Uploaded by

tidachin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PRODUCT DATA

www.nortechcontrol.com

Single Channel Loop Detectors


PRODUCT DESCRIPTION
One of the most critical components of the whole vehicle access control
system is the inductive loop detector. Nortechs detectors have been
renowned for their reliability and durability for many years.
Single channel loop detectors are used to identify the presence of vehicles
by means of an inductive loop buried under the road. These single chip
microprocessor-based units benefit from a detect filter and frequency
indicator and are suitable for parking control and motorised door or gate
applications all detectors are CE tested and approved.
A compact detector diagnostic unit is available for extracting data from new
and existing sites.

PD130

FEATURES
PD130 - Vehicle Detector

Compact size
Elegant Styling
Diagnostic capabilities
Selectable permanent presence
Loop isolation protection
Loop frequency indication

Compact size
Selectable permanent presence
Selectable presence output (Fail
Safe / Fail Secure)
Loop isolation protection
Visual output LED (fault monitor)

Automatic Sensitivity Boost (ASB)


Detect filter

PD139 - Card Based Vehicle Detector

GD100 - Vehicle Detector

Compact size
Diagnostic capabilities
Selectable permanent presence
Loop isolation protection

DU100 - Detector Diagnostics Unit

Compact, self-contained test


Exclusive optical readout
No service disruption
Loop diagnosis
Historical data available
Unique crosstalk monitor

Loop frequency indication


Automatic Sensitivity Boost (ASB)

GD100

Selectable relay output configuration


Loop fault monitor

Applications





Parking barrier control


Rising bollards
Motorised gates and doors
Industrial control systems
Rising kerbs
High-speed rapid roll industrial doors

PD139

ISSUE 05

DU100

Single Channel Loop Detectors


Technical Details

PD130

Face-plate LED Indicators:

PD139

GD100

POWER

RSET

+24V DC or 24V AC
0V DC or Nuetral AC

3. Detect - on steady

1 2 3 4 5 6 7 8

PRES
PULSE
FILT
ASB

2. Undetect - off

ON

SENS
FREQ

4. Fault - on with short off

1
PIN 10

PIN 1

MODE

Operating Modes:
1. Limited presence/
permanent presence

RESET
1

2. Pulse on detect/pulse on
undetect
3. Automatic sensitivity
boost off/on

SW1

CH1

1. Tuning - on steady followed


by flashing frequency
count (x 10kHz)

LED1

Green - channel indicator:

LED2

Red - power,

Presence

2
3

Pulse

4. Filter off/on (2 second


delay)

7
9

11

Pulse

Presence

10

Ext Reset

+ DC

- DC

GD 100
6

9
10

N
L
Power

Presence

Pulse

Specifications
PD130/PD139
Self tuning range:
Sensitivity:

20-1500mH
4 step adjustable:
High: 0.02% DL/L; Medium High:
0.05% D L/L; Medium Low: 0.1%
DL/L; Low: 0.5% DL/L
4 step adjustable, 12-80kHz
(frequency determined by loop
geometry)

Frequency:

PD130 Output Relays:

PD139 Output Relay:

Presence output relay - Change-over


contacts (fail-safe) rated at 5A @
230V AC
Pulse output relay - Change-over
contacts (non-fail-safe) rated at 5A
@ 230V AC
Presence output relay - Change-over
contacts (fail-safe) rated at 1A @
230V AC
Pulse output relay - Change-over
contacts (non-fail-safe) rated at 1A @
230V AC

PD130 Pulse output duration: Approx. 150ms, factory option


250ms
PD139 Pulse output duration: Approx. 150ms
Automatic Sensitivity Boost: Switch selectable

Presence time:

1 hour for 3% DL/L, permanent


presence option

Protection:

Loop isolation transformer,


zener diode clamping on loop inputs
and gas discharge tube protection

PD130 Power requirements:




120V AC +/- 15% 48-60Hz (PD131)


230V AC +/- 15% 48-60Hz (PD132)
12-24V AC/DC +/- 15% (PD134)
Requirement: 1.5VA max @ 230V

PD139 Power requirements:


24V AC/DC +/- 15%


Requirement: 1.1VA max @ 24V DC

Operating temp range:

-40oC to +80oC (circuit sealed


against condensation)
PD130: High heat ABS blend
PD130: 76 x 40 x 78; PD139: 105 x
68
PD130: Shelf or DIN-rail socket;
PD139: Panel or plug-in

Material:
Dimensions (mm):
Mounting:

Connector:

Option:

PD130: Single rear mount 11-pin


submagnal (86CP11); PD139: Molex
10-pin female
Flying leads

Ordering Information
PD131:

Single channel, boxed, 120V AC

PD132;

Single channel, boxed, 230V AC

PD134:

Single channel, boxed, 12-24 V AC/DC

PD139:

Single channel, PCB, 24V DC

PD139-FAAC:

Single channel, PCB, designed to fit FAAC


barrier controllers

GD100:

Single channel DIN rail mount detector, 24V


AC/DC

DU100

Detector diagnostic unit

Nortech Control Systems Limited w Nortech House w William Brown Close w Llantarnam Park w Cwmbran w South Wales w NP44 3AB
P: +44 (0) 1633 485533 w F: +44 (0) 1633 485666 w E: [email protected] w W: www.nortechcontrol.com

You might also like