Project :
Calculating the pressure tank size
Pressure tank size formula is given as follows :
size = (
Drawdown volume
cut-out pressure - cut-in pressure
cut-out pressure + 1
Drawdown is based on pump capacity and the number of start/stops per hour and amount of
water which can be taken from the tank before the pump starts.
250 x Q
I
Drawdown in liters =
250 x Q x (cut-out pressure + 1)
I x ( cut-out pressure - cut-in pressure )
Tank size in liters = (
Where : Q is the average pump flow in m3/h
I is the number of starts/stops per hour.
cut in & cut out : pressure is indicated in bars.
Data :
Pump type & model :
P=
5.5
kw
Number of starts/stops
I =
50
1/h
Average pump flow
cut in pressure
cut out pressure
Q=
=
=
16
3.5
4.5
m3/h
bar
bar
calculated data
GRUNDFOS MODEL : CR 16 -30
Motor power rating
Tank size in liters =
input data
( from pump manufacturer )
250 x 16. x ( 4.5 + 1 )
)
50. x ( 4.5 - 3.5 )
The available standard size is :
Recommended tank size is :
440
liters
500
liters
liters
Note :