0% found this document useful (0 votes)
805 views5 pages

TMT Steel Bar Test Results Report

The document summarizes test results for three samples of TMT steel bars with diameters of 20mm, 25mm, and 32mm. The samples were tested for various mechanical properties including diameter, cross-sectional area, gauge length, weight per meter, yield stress, ultimate stress, elongation, bend, and rebend. The test results showed that all properties of the three samples met or exceeded the minimum specifications according to Indian Standard IS-1786 for the stated grade of Fe 415 steel.

Uploaded by

Rakesh7770
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
805 views5 pages

TMT Steel Bar Test Results Report

The document summarizes test results for three samples of TMT steel bars with diameters of 20mm, 25mm, and 32mm. The samples were tested for various mechanical properties including diameter, cross-sectional area, gauge length, weight per meter, yield stress, ultimate stress, elongation, bend, and rebend. The test results showed that all properties of the three samples met or exceeded the minimum specifications according to Indian Standard IS-1786 for the stated grade of Fe 415 steel.

Uploaded by

Rakesh7770
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
  • Test Results of TMT Steel Bar - Sample 1: Provides detailed test results for a specific sample of TMT steel bar, including client information and test parameters.
  • Test Results of TMT Steel Bar - Sample 2: Presents test results for another sample of TMT steel bar with similar layout and client details as previous.
  • Test Results of TMT Steel Bar - Sample 3: Contains test data for the third set of TMT steel bar sample, maintaining consistency in data presentation.

Test Results of TMT Steel Bar

Forwarded to; Name of Client : Senior Section Engineer ( C ) (Works) Western Railway-Patan
Senior Section Engineer
( C ) (Works) Western Railway- Name of Work : DY/CE/C/PYN-BUDI/8
Patan
Ref [Link] Date: T.N. PTM-BUDI/8 Dtaed: '05/12/10
Sample Sent by : Client
Report No.: MAP/10-11/12/05/AS-3 Name of Agency : M/s Ajay Engi Infra Pvt Ltd. Mehsana
Date: 13/12/10 Agreement No.: --
Page : 1 of 1 Structure(s) Name: --
Date of Sample Received: 05/12/10 Type of Sample : TMT Steel Bars
No. of Sample(s): 1 Diameter of Sample: 20.00 mm
Condition of Sample on Receipt: Satisfactory Specification of Sample:
Name of Test: As mentioned below Garde of Sample : Fe 415
Test Method Standard: As mentioned below Environmental Condition during test : As per the test procedure
Date of Test Starting : 05/12/10 Date of Test Completion : 12/12/10
Sr. Test Method Results obtained Specifications Remarks
Type of Test
No. Standard Sample-1 Sample-2 Sample-3 As per IS - 1786

1 Diameter (mm) IS - 1786 20.04 -- -- Min. 20.00 mm

2 Cross Sectional Area (mm2) IS - 1786 315.26 -- -- Min. 314.3 mm2

3 Gauge Length ( mm ) IS - 1608 100.32 -- -- Min. 100 mm

4 Weight per meter run (kg ) IS - 1786 2.470 -- -- Min. 2.47 Kg/m 3 %

Results are
Yield Stress / Proof Stress 0.2 %
5 IS - 1608 428 -- -- Min. 415 N/mm2 Conformed as
(N/mm2)
per IS-1786

6 Ultimate Stress (N/mm2) IS - 1608 520 -- -- Min . 485 N/mm2

7 Elongation ( % ) IS - 1608 24.10 -- -- Min. 14.5 %

8 Bend IS - 1599 No Crack -- --


Should not show any
transverse Crack
9 Rebend IS - 1786 No Crack -- --

* The test result relates to the sample(s) supplied by the client/agency. for MAP Technical Consultancy
NOTES

* The Results / Reports are issued with specific understanding that MAP will not
in way be involved in acting following interpretation of the test results.
* The Results / Reports are not supposed to be used for publicity. Authorised Signatory
Test Results of TMT Steel Bar
Forwarded to; Name of Client : Senior Section Engineer ( C ) (Works) Western Railway-Patan
Senior Section Engineer
( C ) (Works) Western Railway- Name of Work : DY/CE/C/PYN-BUDI/8
Patan
Ref [Link] Date: T.N. PTM-BUDI/8 Dtaed: '05/12/10
Sample Sent by : Client
Report No.: MAP/10-11/12/05/AS-3 Name of Agency : M/s Ajay Engi Infra Pvt Ltd. Mehsana
Date: 13/12/10 Agreement No.: --
Page : 1 of 1 Structure(s) Name: --
Date of Sample Received: 05/12/10 Type of Sample : TMT Steel Bars
No. of Sample(s): 2 Diameter of Sample: 25.00 mm
Condition of Sample on Receipt: Satisfactory Specification of Sample:
Name of Test: As mentioned below Garde of Sample : Fe 415
Test Method Standard: As mentioned below Environmental Condition during test : As per the test procedure
Date of Test Starting : 05/12/10 Date of Test Completion : 12/12/10
Sr. Test Method Results obtained Specifications Remarks
Type of Test
No. Standard Sample-1 Sample-2 Sample-3 As per IS - 1786

1 Diameter (mm) IS - 1786 25.02 25.03 -- Min. 25.00 mm

2 Cross Sectional Area (mm2) IS - 1786 491.41 491.80 -- Min. 491.1 mm2

3 Gauge Length ( mm ) IS - 1608 125.25 125.30 -- Min. 125 mm

4 Weight per meter run (kg ) IS - 1786 3.850 3.846 -- Min. 3.85 Kg/m 3 %

Results are
Yield Stress / Proof Stress 0.2 %
5 IS - 1608 420 416 -- Min. 415 N/mm2 Conformed as
(N/mm2)
per IS-1786

6 Ultimate Stress (N/mm2) IS - 1608 516 510 -- Min . 485 N/mm2

7 Elongation ( % ) IS - 1608 20.50 20.68 -- Min. 14.5 %

8 Bend IS - 1599 No Crack No Crack --


Should not show any
transverse Crack
9 Rebend IS - 1786 No Crack No Crack --

* The test result relates to the sample(s) supplied by the client/agency. for MAP Technical Consultancy
NOTES

* The Results / Reports are issued with specific understanding that MAP will not
in way be involved in acting following interpretation of the test results.
* The Results / Reports are not supposed to be used for publicity. Authorised Signatory
Test Results of TMT Steel Bar
Forwarded to; Name of Client : Senior Section Engineer ( C ) (Works) Western Railway-Patan
Senior Section Engineer
( C ) (Works) Western Railway- Name of Work : DY/CE/C/PYN-BUDI/8
Patan
Ref [Link] Date: T.N. PTM-BUDI/8 Dtaed: '05/12/10
Sample Sent by : Client
Report No.: MAP/10-11/12/05/AS-3 Name of Agency : M/s Ajay Engi Infra Pvt Ltd. Mehsana
Date: 13/12/10 Agreement No.: --
Page : 1 of 1 Structure(s) Name: --
Date of Sample Received: 05/12/10 Type of Sample : TMT Steel Bars
No. of Sample(s): 1 Diameter of Sample: 32.00 mm
Condition of Sample on Receipt: Satisfactory Specification of Sample:
Name of Test: As mentioned below Garde of Sample : Fe 415
Test Method Standard: As mentioned below Environmental Condition during test : As per the test procedure
Date of Test Starting : 05/12/10 Date of Test Completion : 12/12/10
Sr. Test Method Results obtained Specifications Remarks
Type of Test
No. Standard Sample-1 Sample-2 Sample-3 As per IS - 1786

1 Diameter (mm) IS - 1786 32.03 -- -- Min. 32.00 mm

2 Cross Sectional Area (mm2) IS - 1786 805.35 -- -- Min. 804.6 mm2

3 Gauge Length ( mm ) IS - 1608 160.34 -- -- Min. 160 mm

4 Weight per meter run (kg ) IS - 1786 6.311 -- -- Min. 6.31 Kg/m 3 %

Results are
Yield Stress / Proof Stress 0.2 %
5 IS - 1608 416 -- -- Min. 415 N/mm2 Conformed as
(N/mm2)
per IS-1786

6 Ultimate Stress (N/mm2) IS - 1608 512 -- -- Min . 485 N/mm2

7 Elongation ( % ) IS - 1608 17.60 -- -- Min. 14.5 %

8 Bend IS - 1599 No Crack -- --


Should not show any
transverse Crack
9 Rebend IS - 1786 No Crack -- --

* The test result relates to the sample(s) supplied by the client/agency. for MAP Technical Consultancy
NOTES

* The Results / Reports are issued with specific understanding that MAP will not
in way be involved in acting following interpretation of the test results.
* The Results / Reports are not supposed to be used for publicity. Authorised Signatory