0% found this document useful (0 votes)
2K views20 pages

Groundwater Hydrology Solutions Guide

This document contains solutions to analytical questions on groundwater hydrology and well hydraulics. It provides step-by-step working to calculate well yield, discharge from tube wells, design of tube wells, and determination of aquifer permeability from pumping test data. In question 1, the yield of a well is calculated as 0.023 l/s given the well diameter, strainer length, drawdown, permeability, and radius of influence. In question 2, the discharge from a tube well is calculated as 0.907 l/s using the given well dimensions, drawdown, permeability, and radius of influence. In question 5, the permeability of an aquifer is calculated as 0.18 m/day based on pumping
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views20 pages

Groundwater Hydrology Solutions Guide

This document contains solutions to analytical questions on groundwater hydrology and well hydraulics. It provides step-by-step working to calculate well yield, discharge from tube wells, design of tube wells, and determination of aquifer permeability from pumping test data. In question 1, the yield of a well is calculated as 0.023 l/s given the well diameter, strainer length, drawdown, permeability, and radius of influence. In question 2, the discharge from a tube well is calculated as 0.907 l/s using the given well dimensions, drawdown, permeability, and radius of influence. In question 5, the permeability of an aquifer is calculated as 0.18 m/day based on pumping
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Preface
  • Question No 1
  • Question No 2
  • Question No 4
  • Question No 3
  • Question No 5
  • Question No 6
  • Question No 7
  • Question No 8
  • Question No 9
  • Question No 10

DEPARTMENT OF CIVIL ENGINEERING

FACULTY OF ENGINEERING & TECHNOLOGY


UNIVERSITY OF ILORIN
ILORIN, NIGERIA

GROUNDWATER HYDROLOGY
(Well hydraulics solved examples)

By:
Dr Olayinka Okeola
Preface
2

This is a comprehensive solution to analytical questions on Groundwater Hydrology. It is useful for


Page

both engineering and geology students desiring a better understanding on analytical solution
procedures on well hydraulics.
Question No 1.
A tube of 30 cm diameter penetrates fully in an aquifer. The strainer length is 15cm. Calculate the
yield of the well under a drawdown of 3m. The aquifer consists of sand of effective size of 0.2mm
having a coefficient of permeability equal to 50m/ day. Assume a radius of drawdown equal to
150m.

Solution:
Well diameter= 30cm, radius r = 15cm = 0.15m
Strainer length L =15cm = 0.15m 50m 1d
Drawdown s = 3m K m/s
Coefficient of Permeability, K = 50m/ day. d 24 3600 s
=5.787 x10-4m/s

Radius of drawdown R= 150m


Yield Q=?
Aquifer Confined Aquifer
Strainers length
150
4
log10 log10 1000 3
2.72bks 2.72 0.15 5.787 10 3 0.15
Q
R 150
log10 log10
r 0.15

=0.023l/s m 3 1000l l

s 1m 3 s

Question No 2.
A tube well penetrates fully an unconfined aquifer. Calculate the discharge from the tube well under
the following conditions.
Diameter of well = 30cm
Drawdown = 2m
Coefficient of permeability=0.05cm/s
Radius of zero drawdown=300m
Length of strainer = 10m

Solution:
Tube well diameter= 30cm r = 0.15m
Drawdown s = 2m
Strainers length L = 10m
Radius of zero drawdown R = 300m k 0.05
cm

1m
m
s
Coefficient of Permeability K = 0.05 cm/s s 100cm
= 5x 10-4m/s

Yield Q=?
Strainers length magnitude Unconfined aquifer
s
2.72ks L
2
Q
3

R
Page

log10
r
2.72 5.0 10 4 20.1 1
300
9.0667m 3 / s
log10 0.15

m3 l
9.0667 1000 3 0.907l / s
s m

Question No 3.
Design a tube well for the following data:
Yield required = 0.08m3/s
Radius of circle of influence= 300m
Drawdown = 5m
Aquifer thickness = 30m
Permeability = 60m/day

Solution:
Yield Q required = 0.08m3/s
Radius of circle of influence = 300m
Aquifer thickness = 30m
Drawdown s = 5m
Permeability K = 60m/day
60m 1d
6.944 10 4 m / s
d 24 3600s

Unconfined Aquifer

R
Q 2.72bks log10
r
R 2.72bks
log10
r Q
300 2.72 30 6.944 104 5
log10 3.541
r 0.08
log10 300 log10 r 3.541
log10 r log10 300 3.541 1.064
log10 r 1.064
r 101.064
100cm
0.086m 9cm m
1m

Question No 4
(a)Derive the expression for the coefficient of permeability of an aquifer of depth H when a well of
radius r is pumping at a steady rate Qo , such that the depth of water in two observation wells
located at distances r1 and r2 from pumped well are h1 and h2 respectively.
4

(b)A well pumping an unconfined aquifer having an initial saturated thickness of 8.2m is pumped at a
Page

rate of 65 L/s until a steady state cone of depression is established. The drawdowns measured at
two observation wells situated 15m and 31m from the pumped well are found to be 1.8m and 1.4m
respectively. Determine the transmissivity of the aquifer.

Observation wells
Solution:

(a) Qo

G.L

W. T

h1 h2

ho

ro r1

r2

The governing Equation is Darcy law given as :


dh
Q VA kiA ki 2rH k 2rh
dr
Qo
h dh dr
2rk
Q Qo cons tan t
Integrating gives

h 2 h2 Q r
ln r 2
2 h1 2k r1
Substituting gives
Qo r 2
5

h22 h12 ln
k r 1
Page
Qo r2
k

h22 h12 ln
r1

Now Q 65 L / s 0.065 m 3 / s
h2 8.2 1.4 6.8m
h1 8.2 1.8 6.4m
r1 15m r2 31m
0.065 31
k
2
6.8 6.4 2
ln
15

k 0.003918 0.7259
k 0.00284 m/s
Transimissivity = kH 0.00284 8.2
Transimissivity = 0.0233 m3/s.m

Question No 5.
In order to determine the field permeability of a field permeability of a free aquifer, pumping out
test was performed and the following observations were made.
Diameter of well= 20cm
Discharge from well =240m3/hr
Level of water surface before pumping started =240.5m
Level of water at constant pumping =235.6m
Level of impervious layer =210.0 m
Level of water in observation well =239.8m
Radial distance of observation well from tube well =50m

Calculate:
1. K
2. error in K if observation are not taken in observation well and radius of influence
is assumed to be 300m
3. actual radius of influence based on observation from the well.

Given:
Diameter of well = 20cm
Discharge from well =240m3/ hr
Level of water surface before pumping started = 240.5m
Level of water at constant pumping = 235.6m
Level of impervious layer =210.0m
Level of water in observation well = 239.8m
6

Radial distance of observation well from tube well = 50 m


Page
Solution:
For test Well:
diameter (d) = 20cm = 0.2m
radius (r) = 0.1m
m3 1h
Q = 240 m3/ h = 240 . 0.0667 m3/s
h 60s 60s
H elevation = 240.5m
H elevation = 235.6m
Impervious elevation = 210m

Hence
H = 240.5 210 30.5m
h = 235.6 210 25.6m
s = H h 4.8m

For observation Well:


Level of water = 239.8m
r1 50m
h 239.8 210 29.8m
s H h 30.5 29.8 0.6m
Radial distance R
Q

0.1m

_ _ _ _ _ _ _ _ _ _ _ _ _r1_ _50_m _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

H= 30.4m
h1

h
Impervious 210 m
layer

NB: Free aquifer = unconfined

(i)
r1
Q log 10
k r

1.36 h12 h 2
7
Page
50
0.0667 log 10
0.1 0.18
k 5.69 10 4 m/s

1.36 29.8 2 25.6 2 316.44

k 49.16 m/day

m 24 3600 s
m d
s 1 day

(ii)

R = 300m

R 300
Q log10 0.0667 log10
r 0.1 0.232
k 6.346 10 4 m/s

1.36 H 2 h 2
1.36 30.4 2 25.6 2 365.57

k 54.83 m/day

Error
54.83 49.16 100 11.5%
49.16

(iii)

log10
R


1.36 H 2 h 2
r Q
R 1.36 5.69 10 4 30.5 2 25.6 2
log10
0.1 0.0667

log 10 R log 10 r 3 . 189

log10 R 3.189 log10 0.1

log10 R 3.189 1 2.189

R 10 2.189

R = 154.5m
8
Page
Question No 6
A 30cm diameter well penetrates vertically through an aquifer to an impermeable stratum located
18.0 m below the static water table. After a long period of pumping at a rate of 1.2 m3/min, the
drawdown in test holes 11m and 35 m from the pumped well is found to be 3.05 and 1.62m
respective. What is the hydraulic conductivity of the aquifer? Express in meters per day. What is its
transmissivity? Express in cubic meters per day per meter. What is the drawdown in the pumped
well?

Pumped well
Observatory well Observatory well
GS

s1 s2

B =18m

r1 11m

r2 35m

Given

B = 18.0m;
Q = 1.2 m3/min = 0.02m3/s;
r1 11m;
r2 35 m;
s1 3.05 m;
s 2 1.62 ; d 0.3 m

Confined Aquifer

2kbh2 h1
Q
9

r
Page

2.303 log 2
r1
But H h s
Substitute: h1 H s1 and h2 H s 2 in equation (1)

2kbs1 s 2
Q
r
2.303 log 2
r1
2k 183.05 1.62
0.02
35
2.303 log
11
0.02 2.303 0.503
k 1.4 10 4 m/s = 12.1m/day
161.73

(ii) T kb 12.1 18 217 .8 m3/day/m

(iii) Drawdown in the pumped well


2kbh1 h
Q
r
2.303 log 1
r2
H hs

Therefore h H s and h1 H s1
Hence,
2kbH s1 H s
Q
r
2.303 log 1
r
2kbs s1
Q
r
2.303 log 1
r
0.0158s 3.05 0.02 2.303 1.865
s 8.49 m (drawdown)
10
Page
Question No 7
2 h 1 h S h
(A.) With the aid of a diagram, derive the unsteady well equation; . defining
r 2
r r T t
the terms involved.

Solution
h
slope h 2 h
Q r slope dr
Initialpiezometric surface r r 2

Instantaneous drawdown

Q2 Q1
h
b

dr
r
Fig. 1: Showing a fully penetrated well in a confined aquifer

Annular Ring

dr
r
r Q2

Section
Fig2: Showing annular ring of well
11

From the principle of continuity of flow, the difference of rate of inflow and the rate of outflow from
Page

the annular cylinder is equal to the rate of change of volume of water within the annular space.
Thus;
V
Q1 Q2 (1)
t
From Darcys law, Q k i flow area

i slope of hydraulic gradient line


h
For inner surface, i
r
h 2 h
But for outer surface, i 2 dr
r r

h 2h
Inflow, Q1 k 2 dr 2 r dr b (2)
r r
h
Outflow, Q 2 k 2r b (3)
r
Also, from the definition of storage coefficient, S which is define as volume of water released per
unit surface area per unit change in head normal to the surface.
Mathematically;
V
S
2r dr dh
V S 2r dr dh (4)

Change in volume with time will give


V h
S ( 2r ) dr (5)
t t
Where t = time since pumping started
Substituting Equations (2), (3) and (5) into Equation (1)
Hence;

h h 2 h h
S 2r dr k 2 dr 2 r dr b kb 2r (6)
t r r r

After expansion Equation (6) divide through by kb2

Equation (6) becomes


h
S r dr
t h h dr r dr h r
2

r r 2 (7)
kb r
But T =kb
12

S h h 2h 2h
dr r 2 dr 2 dr
2
r dr
Page

(8)
T t r r r
Dividing Equation (8) through by r dr

S h 1 h 2 h 2 h dr
(9)
T t r r r 2 r 2 r
2h 2h
But and dr are small dr is negligible
r 2 r 2
Hence Equation (9) becomes

2 h 1 h S h
(10)
r 2 r r T t
Equation (10) is the basic unsteady flow Equation towards a well.
S = storage coefficient (dimensionless)
T = transmissivity (m3/day/m)
h
slope of hydraulic gradient line dim ensionless
r
2h
sec ond derivative of the hydraulic gradient line dim ensionless
r 2

(B) Discuss Theis solution to the equation above?

Theis solution to the Equation (10) can be achieved base on analogy between groundwater flow
towards a well and flow of heat towards a sink. The well coefficients, S and T can be evaluated using
Theis method by conducting pumping tests. The well is pumped at a constant discharge rate, Q and
the change in drawdown with time in one or more observation wells is measured.

The steps involve in the Theis method are:


1. W (u) and (u) are plotted on log-log paper using standard values from table W (u) against (u)
known as type curve.
2. r2/t is computed for different values of drawdown
3. drawdown (s) is plotted against r2/t on log-log tracing paper using the same scale as W (u)
against (u), this curve is known as data curve.
4. Coordinates of the axes of the two curves are kept parallel
5. The data curve is superimposed on the type curve such that most points on the curves fall
on each other.
6. An arbitrary point, P called the matching point on the overlapped curves is selected.
7. Coordinates of the point P for both curves are selected
8. The values of Storativity (S) and Transmissivity (T) are calculated from the following
equations :

4T
S
u
Q
r2 T W u
4 s
13

t
Where s, r2 , W u and u are points corresponding to the coordinate P.
Page

t
s = drawdown (m)
r = radial distance between the wells (m)
t = pumping period (day)

(C.) Discuss the concept of safe yield from wells, emphasizing the factors affecting well yield ?

The term safe yield of groundwater basin can be defined as the amount of water which can be
withdrawn from a basin annually without producing an undesirable result. It is also the amount of
water withdrawn continuously without affecting the supply of other landowners. Any draft in excess
of safe yield is overdraft. The determination of safe yield of groundwater basin requires analysis of
undesirable results which may occur if safe yield is exceeded.

There are four factors governing safe yield namely: water supply, economies of pumpage, water
quality and water rights.

1. Water supply is the most important and also the most subjective to qualitative
determination. The water supply to a basin can be limited either by the physical size of
groundwater basin or by the rate at which water moves through the basin from the recharge
area the withdrawal area.
2. Economics factor may govern water supply in basins where the cost of pumping
groundwater becomes excessive. Excessive pumping costs are usually associated with
lowered groundwater levels, which may necessitate deepening of wells, lowering of pump
bowls and installing larger pumps.
3. Water quality:- safe yield may be exceeded if a basin produces a groundwater of inferior
quality. A quality limitation on safe yield depends on the minimum acceptable standard of
water quality, which in turn depends on the made of the pumped water.
4. Water rights:- legal consideration may limit safe yield of a basin if there is interference with
prior water rights within a basin or in adjacent basins. Any legal restriction on pumpage
would have to be established before the safe yield could be determined.

Question No 8

The following observations were recorded during a pumping out test on a tube well penetrating fully
in a free aquifer:
Well diameter = 25cm
Discharge from the well = 300 m3/hr
R.L of original water surface before pumping started = 122.0 m
R.L of water in well at constant pumping = 117.1 m
R.L of water in the observation well = 121.3 m
R.L of impervious layer = 92.0 m
Radial distance of observation well from the tube well = 50 m
14

Determine (a) the field permeability coefficient and


Page

(b) radius of zero draw down.


Solution
For test well d 25 cm 0.25 m
0.25
r 0.125 m
2
3 m3 1h 3
Q 300 m 300 0.083 m
h h 60 60 s s
H elevation 122.0 m
helevation 117.1 m
Im pervious elevation 92.0 m
H 122.0 92.0 30 m ; h 117.1 92 .0 25.1 m
For observation well
Level of water = 121.3 m
h1 121.3 92.0 29.3m
r1 50 m
S = H h = 30.0 29.3 = 0.7m

Radial distance, R Q = 0.083 m3/s

r1=50m r = 0.125m

H=30m h1=29.3m

h=25.1m 92.0m
Impervious layer

Free aquifer = unconfined aquifer

(a) Field permeability coefficient (k) is given as:

r 50
Q log 1 0.083 log
r 0.125
k 6.95 10 4 m
s
15

1.36 h12 h 2 1.36 29.3 2 25.12


Page
m 60 60 24s
k 6.95 10 4 60.05 m
s 1day day

(b) Radius of zero drawdown = Radius of influence (R)

Q

1.36 k H 2 h 2
R
log
r

0.083

1.36 6.95 10 4 30 2 25.12
R
log R
0.125 log10 3.075
0.125
4 2
R 1.36 6.95 10 30 25.1
log
2
R
0.125 0.083 103.075
0.125
R 148.6m
R
log 3.075
0.125

log R log 0.125 3.075


log R 3.075 log 0.125
log R 3.066 0.9031
log R 2.172
R 10 2.172 148 .6 m

Hence the radius of zero drawdown, R = 148.6 m

Question No 9

An extensive horizontal confined aquifer having a constant thickness of 40m is pumped steadily by a
series of identical wells located at 300m intervals in a N-S line. Each well completely penetrates the
aquifer and delivers 20 Ls-1. Field measurements a long way to the east of the well line shows a
hydraulic gradient of 1 in 175 and similarly to the west of the wells a hydraulic gradient of 1 in 500.
Both piezometric surfaces slope in westerly direction. Estimate the Darcy hydraulic conductivity of
the aquifer.

Solution
B = 40m
20 3
Q = 20 Ls-1 = 0.02m
1000 s
Distance between wells = r =300m
dh
16

i = hydraulic gradient =
dr
Page
1
i1 = 1 in175 = 0.0057 in eastern direction
175
1
i2 = 1 in 500 = 0.02 in western direction
500

W E
Q =0.02 m3/s

r1=300m
S

i1 =0.057
i2 = 0.02

b = 40m

Impervious stratum
The basic equation for confined aquifer is given as:
dh
Q 2 k b r
dr
dh
Where i hydraulic gradient line
dr
0.02 2 k 40 300 0.0057

Note that i1 is used because the Darcy hydraulic conductivity is required for western direction and
i2 is already in western direction.
0.02
k
2 40 300 0.0057
k 4.65 10 5 ms 1
k 4.65 10 5 60 60 24
k 4.02 m
day
Hence, Darcy hydraulic conductivity of the aquifer is k 4.02 md 1
17
Page
Question No 10

(A)
A well penetrates fully a 10m thick water bearing stratum of medium sand having a coefficient of
permeability of 0.005m/s. The well radius is 10cm and is to be worked under a drawdown of 4m at
the well face. Calculate the discharge from the well. What will be the % increase in discharge if the
radius of the well is doubled? Take R = 300 m in each case.

(B)
An artesian tube well has a diameter of 20cm. The thickness of aquifer is 30m and its permeability is
36 m/day. Find its yield under a drawdown of 4 m at the well face. Use:
(i) Radius of influence as recommended by Sichardt
(ii) Assume a radius of influence of 300m
(iii) Comment on the difference between the values of R estimated in (i) and (ii)

(C)
A tube well penetrates fully a 8m thick water bearing stratum (confined) of medium sand having a
coefficient of permeability of 0.004m/s. The well radius is 15cm and is to be worked under a
drawdown of 3m at the well face. Calculate the discharge from the well. What will be the % increase
in the discharge if the radius of the well is doubled? Take radius of zero drawdown to be 400m in
each case.

Solution 10A

The aquifer is confined


2.72 b k s
Q
R
log10
r
b = 10 m; k = 5 x 10-3 m3/s; R = 300 m; r = 10 cm = 0.1m; s = 4 m

2.72 10 5 10 3 4
Q ; Q = 0.156 m3/s
300
log10
0.1

When the radius is doubled, r = 20cm = 0.2m

2.72 10 5 10 3 4
Q ; Q = 0.173 m3/s
300
log10
0. 2

0.173 0.156
% increase = = 11 %
0.156

Comment:
The size of the well has very little influence on the discharge. It can be seen that discharge only
increased by a mere 11 % despite doubling of radius.
18
Page
Solution 10B

2.72 b k s
Q
R
log10
r
Radius of well as recommended by Sichardt, R is given as
R 3000 r k ; s = 4 m; k = 36 m/day; b = 30 m
d
R= 10 cm 0.1 m
2
36
R 3000 4 245 m
24 3600
(i)
36 4
2.72 30
Q 24 3600 ; Q = 0.040 m3/s = 40 L/s
245
log10
0.1

(ii) Using R = 300 m

36 4
2.72 30
Q 24 3600 ; Q = 0.039 m3/s = 39 L/s
300
log10
0.1

Comment:
No significant difference between the values of discharge using Sichardt formula with the
assumption R = 300 m.

Solution 10C

The aquifer is confined


2.72 b k s
Q ;b = 8m; k = 0.004 m/s; r = 15 cm = 0.15 m; R = 400m; s = 3 m; Q = ?
R
log
r
2.72 8 0.004 3
Q1
400
log 10
0.15

Q1 = 0.0762 m3/s = 274 m3/hr

If radius of well is doubled, r = 30 cm = 0.3 m

2.72 8 0.004 3
Q2
400
log10
0.3
Q2 = 0.0836 m3/s = 301 m3/hr; Increase in discharge = 301 274 = 27 m3/hr
19

% increase = 27 100 9.8 %


274
Page
This page is left blank

20
Page

Dr Olayinka Okeola (email: ogolayinka@[Link]; okeolaolayinka@[Link]; mobile no: +234 (0) 703 230 7770