BenQ W6000
Digital DLP Projector Training
Course
Presenter : Jason Chiou
2010/03
Course Outline
• Product Introduction
• Electric Circuit Block Diagram
• Download Firmware and RS232 setting
• Factory mode
• Alignment and Adjustment
PC and YPbPr Alignment
DLP C/W delay Alignment
• Trouble shooting
LED message
Error message
• Mechanical Part
BenQ Confidential 2010, BenQ Corporation
Product Overview
Product Introduction
• Imager: 0.65 DLP 1080P panel
• Resolution: 1080p
• Brightness: 2500 ANSI Lumens (Marketing Spec)
( Min. 2000 ANSI Lumens)
• Contrast Ratio: 30000:1 (Min. Spec)
• Lamp: Philips 280W (AC)
• Lamp Life: 2000 hrs (Normal mode)
3000 hrs (Economic Mode)
• Throw Ratio: 55.7”@2M
• Zoom Ratio: > 1.5x
• Noise Level: 32/29dB (Normal/Economic mode)
BenQ Confidential 2010, BenQ Corporation
Connector
• Input Terminal :
Component1 Input: RCA (Red Green Blue)
Video Input : RCA jack (Yellow)
S-Video : 4 pin Mini-Din (Female)
PC and Component 2 Input : D-Sub
HDMI1 Input
HDMI2 Input
• Output Terminal :
12V screen trigger
• RS232 Control Connector
BenQ Confidential 2010, BenQ Corporation
Remote control
BenQ Confidential 2010, BenQ Corporation
Projector Structure Color Wheel &
DB motor
Thermal
sensor 1
(on M/B)
Fan 3: Fan 1:
Blower Fan Lamp Fan
Thermal
sensor 2
(on M/B)
Fan 2:
Outlet Fan
Main
BD
BenQ Confidential 2010, BenQ Corporation
Electric Circuit
Block Diagram
Main Board Block Diagram
BenQ Confidential 2010, BenQ Corporation
Component of Main board and Chip board
A. Scalar parts
• T1+(REON-210) : Image processor of SOI (Silicon Optix Inc.)
• Flash : 256 Mbits flash memory
• Clock :
T1+ : 27 MHz
DDR RAM : 215MHz
• Video Decoder :
TI TVP5160 (For NTSC、PAL、SECAN)
• A/D Converter :
AD9984A (For PC and Component signal)
• HDMI :
SiI 9125 (HDMI receiver)
• DDR RAM: HYNIX HY5DU281622FTP-4
• Fan controller :
G793 ( Fan 1~3 )
BenQ Confidential 2010, BenQ Corporation
Component of Main board and Chip board
B. Formatter parts
• DDP3021 : DLP Image processor of TI
• Flash : 32 Mbits flash memory
• Clock :
DDP3021: 50 MHz
• Lattice FPGA :
4 sets LVDS input from DDP3021and 2 sets LVDS out to DMD chip.
• TPS65145PWP :
DMD voltage and control ASIC from TI
• Color wheel controller :
PMD1000 power/motor controller
• RLD RAM: MICRON MT49H8M36BM
• DB motor controller :
MSP430F2011IPWR
BenQ Confidential 2010, BenQ Corporation
Main board ( TOP )
DDP3021 Flash for
PMD1000 RLDRAM RLDRAM DDP3021
POWER DDR_RAM TVP5160 SiI 9025 PMD1000
CONN
BenQ Confidential 2010, BenQ Corporation
Main board ( Bottom )
Power control Lattice FPGA Flash for DB Motor
DDP3021 control
DDR_RAM T1+ 256Mbit flash AD9984
BenQ Confidential 2010, BenQ Corporation
Chip board ( TOP )
TP65145PWP
BenQ Confidential 2010, BenQ Corporation
Chip board ( Bottom )
BenQ Confidential 2010, BenQ Corporation
Circuit Board
• Main Board
• Chip Board
• IR Sensor Board
• Power Board
• Key Pad board
• Ballast Board
IR board Key Pad board
Ballast Power Main Chip
board board board board
BenQ Confidential 2010, BenQ Corporation
Main board Connector (TOP)
To Chip board
Power in For T1+ Flash
download
BenQ Confidential 2010, BenQ Corporation
Main board Connector (Bottom)
CW Sensor BD CW motor DB motor
Blower Fan DB Sensor BD
Lamp Fan
DB FW
download
Keypad BD
Outlet Fan
8051 For DDP3021
download Flash download
BenQ Confidential 2010, BenQ Corporation
Key Pad board
Temp LED
Power LED Lamp LED
UP
Power
Preset Mode
Left Right
Enter
Source Exit
Down
Menu
BenQ Confidential 2010, BenQ Corporation
Key Pad board
To IR board
To Main BD
BenQ Confidential 2010, BenQ Corporation
Download Firmware and
RS232 setting
When you download F/W or change M/B,
What do you need to do ….
1. Read data
2. Download firmware
3. Write data
4. Adjust C/W delay
BenQ Confidential 2010, BenQ Corporation
Firmware Download
• Tool :
Download cable (RS232 connect to PC/Notebook)
Personal computer or Notebook
Download tool program “Updater”
• Firmware files :
[Link]
BenQ Confidential 2010, BenQ Corporation
Firmware Download
• Procedure:
• Power off the unit and unplug power cord.
• Prepare the download equipment.
A RS232 cable connect to PC and projector
• Push Right key on the keypad and plug in power cord.
• After three LEDs show orange light, release Right key.
BenQ Confidential 2010, BenQ Corporation
Firmware Download
• Execute download program “updater”.
• Select the target on UART and click search.
BenQ Confidential 2010, BenQ Corporation
Firmware Download
• Key in the file path or use “Browse” to select where the file is,
and click “ BOOT-
BOOT-SOI {…
{…}
BenQ Confidential 2010, BenQ Corporation
Firmware Download
• Select (Blank) the target boot, then click “Update Firmware” button.
Click here
BenQ Confidential 2010, BenQ Corporation
Firmware Download
• After download completed, please exit download program and unplug the
power cable on projector.
• Plug in the power cable again and light on projector. It will be initialized by
new firmware.
BenQ Confidential 2010, BenQ Corporation
RS232 setting
RS232 Control Code
• Hardware required
1. RS232 cable
2. Personal computer or
laptop computer
• Software required
1. PC setting please see
following picture.
2. RS232 Code refers to:
W6000 RS232
BenQ Confidential 2010, BenQ Corporation
Read data
• Tool
Install W6000 service tool
PC
RS232 CABLE
BenQ Confidential 2010, BenQ Corporation
Read data from projector
1. Open the W6000 Service Tool from tool bar
BenQ Confidential 2010, BenQ Corporation
Read data from projector
2. Use Setup to change COM port setting
Use the Setup item to
change comport
setting
Finish setting and
punch Save button
BenQ Confidential 2010, BenQ Corporation
Read data from projector
3. Write the original SN number
Change to this page
Write the original
projector serial
number
BenQ Confidential 2010, BenQ Corporation
Read data from projector
4. Read the original Main board data
Punch this button and
read data
※This procedures would
need 4 minutes . Please
wait for patient !
BenQ Confidential 2010, BenQ Corporation
Read data from projector
5. Finish reading data
Have data now
BenQ Confidential 2010, BenQ Corporation
Read data from projector
6. Where is the file~
The data will be in this
route. And file name
is [Link]
BenQ Confidential 2010, BenQ Corporation
Write data from program
1. Use Setup to find where the data is
Finish setting and
punch Save button
BenQ Confidential 2010, BenQ Corporation
Write data from program
2. Use Retrieve System item to write the data
Change to this page
Punch the button to
write data to new
board
※This procedures would
need 4 minutes . Please
wait for patient !
BenQ Confidential 2010, BenQ Corporation
Write data from program
3. Finish Writing data
BenQ Confidential 2010, BenQ Corporation
Factory mode
How to enter the Factory mode
• Use Remote control or Keypad and change OSD to
information page and press up->down->up->down keys
BenQ Confidential 2010, BenQ Corporation
How to enter the Factory mode
• In Factory page
Reset lamp hour
Reset all factory data
without lamp hour and
System control MCU page
date (Do not change !!!)
BenQ Confidential 2010, BenQ Corporation
Factory Mode data
• Items:
Lamp hours
Reset Lamp Timer
-Reset total projector life timer
BenQ Confidential 2010, BenQ Corporation
Fan Control & Thermal sensor (For Debug use)
• Enter Method:
Select “Thermal test” and press
“Enter”.
• Items:
Room Temperature - T1
− The temperature of sensor 1.
Lamp Temperature - T2
− The Temperature of sensor 2.
Lamp Fan: The speed of fan 1.
Outlet fan: The speed of fan 2.
Blower Fan: The speed of fan 3.
Function for debug and test
− Manual Fan speed
BenQ Confidential 2010, BenQ Corporation
Alignment and Adjustment
-PC and YPbPr Alignment
PC Alignment
• Source:
Source:D-SUB
• ADC :AD9984
• into factory OSD
• select ADC Calibration
• input test pattern with SXGA
timing 1280×
1280×1024@60Hz
• Select PC Format
• Press AD9984…
• Press PC Format…
• Press Auto Calibration
BenQ Confidential 2010, BenQ Corporation
YPbPr Alignment
• Source:
Source:Component
• ADC :AD9984
• into factory OSD
• select ADC Calibration
• input test pattern with 720P timing
• select source Component 1
• Press AD9984…
• Press YPbPr Format …
• Press Auto Calibration
BenQ Confidential 2010, BenQ Corporation
YPbPr Alignment
• Source:
Source:Component
• ADC :AD9984
• into factory OSD
• select ADC Calibration
• input test pattern with 1080P timing
• select source Component 1
• Press AD9984…
• Press YPbPr Format …
• Press Auto Calibration
BenQ Confidential 2010, BenQ Corporation
Alignment and Adjustment
-DLP C/W delay Alignment
How to change CW Delay…
Delay…
1. Enter factory mode
2. Enter Icon “DLP…”
3. Change CW Delay
BenQ Confidential 2010, BenQ Corporation
BenQ Confidential 2010, BenQ Corporation
BenQ Confidential 2010, BenQ Corporation
Trouble Shooting Guide
- Error message (Error count record)
- LED message
Error count & LED message
• Projector System will auto turn off and cooling when
it detect error.
• This model provides two ways to indicate error in
projector.
Error count record in Factory Mode
LED error message on keypad
BenQ Confidential 2010, BenQ Corporation
How to see Error Count
• Enter Factory mode
• In System control MCU page
BenQ Confidential 2010, BenQ Corporation
How to see Error Count
− There are three kinds of error
records
• Fan error records
• Thermal error records
• Other error records
BenQ Confidential 2010, BenQ Corporation
LED message
Normal State
Power Temp Lamp Status Note
O - -
Stand-by
G - -
Powering up
G - - Normal
Normal operation
States
O - -
Normal power-down cooling
R - R
Scaler reset fail
O O O
Download Updater
Remark :
: Continuous lighting G : Green Light R : Red Light
: Flash lighting O : Orange Light
BenQ Confidential 2010, BenQ Corporation
LED message
Lamp Error Messages
Power Temp Lamp Status Note
- - R
Lamp error in normal operation Check Lamp
O - R
Lamp is not lit up or C/W wires
Remark :
: Continuous lighting G : Green Light R : Red Light
: Flash lighting O : Orange Light
BenQ Confidential 2010, BenQ Corporation
LED message
Remark :
: Continuous lighting G : Green Light R : Red Light
: Flash lighting O : Orange Light
BenQ Confidential 2010, BenQ Corporation
Mechanical Part assembly
concern
Direction of Thermal breaker
The text-side is outside and copper-side is inside. Wire of thermal breaker
On nozzle
text-side
BenQ Confidential 2010, BenQ Corporation
Wire of thermal breaker
The wire of thermal breaker should be pass through the boss
of nozzle as below, and then connect wire into PWR directly.
Correct Wrong Connect wire into PWR directly
DB motor wire
BenQ Confidential 2010, BenQ Corporation
Wire for Door Switch
Door switch direction :
Wire pins must be set on inner side.
Side of wire on lamp box Side of PWR
Connect wire into PWR directly
BenQ Confidential 2010, BenQ Corporation
Lamp wire
A : Cable (Ballast -> Lamp )
Side of Pass hole of Fixed by clip on lamp
PWR mylar box
Wire pass through the hole
Wire pass through the boss
of mylar on nozzle
(behind the boss)
BenQ Confidential 2010, BenQ Corporation
Wire for Ballast signal
The wire of ballast signal pass through
between PWR and Ballast (Under PWR)
Side of Ballast Side of PWR
BenQ Confidential 2010, BenQ Corporation
Wire of PWR/Ballast 380V
The wire of PWR/Ballast 380V connect to PWR
directly
Side of PWR
Side of Ballast
BenQ Confidential 2010, BenQ Corporation
Clip for blower wire/ wire dressing
Clip
Blower wire
Blower
BenQ Confidential 2010, BenQ Corporation
Lamp fan
On Lower Case
Wire of lamp fan pass through the slot of
lamp box plate.
Lamp fan wire
Fix wire of lamp fan by clip and then
connect to MB
BenQ Confidential 2010, BenQ Corporation
CW wheel/DB sensor/DB motor wire
DB sensor wire
DB motor wire
Wire should be behind plate
CW wheel wire
Fix wire of CW wheel wire by
clip and then connect to MB
BenQ Confidential 2010, BenQ Corporation
Ground wire
The Wire of ground should be on right side of foot.
BenQ Confidential 2010, BenQ Corporation
Wire for IR BD
On Upper case
Wire for IR BD must go through the indicated ribs.
BenQ Confidential 2010, BenQ Corporation
Q&A