75% found this document useful (4 votes)
3K views2 pages

Vertical Ladder Load Analysis

The document analyzes the structural integrity of a vertical ladder attached to a horizontal aboveground fuel tank. It calculates the required and actual load ratings of the ladder components and connections. It determines that the stresses induced on the side rails, rungs, and supports are below the allowable stress limits. It also determines the shear stresses in all fillet welds connecting the ladder parts are below the allowable weld shear stress. Therefore, all components and welds of the ladder are deemed structurally sufficient and safe for the intended load.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
75% found this document useful (4 votes)
3K views2 pages

Vertical Ladder Load Analysis

The document analyzes the structural integrity of a vertical ladder attached to a horizontal aboveground fuel tank. It calculates the required and actual load ratings of the ladder components and connections. It determines that the stresses induced on the side rails, rungs, and supports are below the allowable stress limits. It also determines the shear stresses in all fillet welds connecting the ladder parts are below the allowable weld shear stress. Therefore, all components and welds of the ladder are deemed structurally sufficient and safe for the intended load.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PROJECT : ABOVE GROUND FUEL

CLIENT : QATAR FUEL (WOQOD)


TANKS PAGE NO.: 1
ITEM DESC. : VERTICAL LADDER
PETROL & GAS CONST. CO.
JOB NO. : 18-04002 REV. NO. : 0
VERTICAL LADDER ANALYSIS FOR HORIZONTAL ABOVEGROUND FUEL TANK

REQ'D STATIC LOAD, 454 kg : 4453 N 454 kg


DEAD LOAD, DL (WT. OF LADDER) : 323 N 33 kg
TOTAL LOAD, P : 4776 N 487 kg

LADDER DIMENSIONS:
LENGTH OF RUNG 300 Ø= 20 w t
LENGTH OF SUPPORT, Lb 225 FLAT 70*10 70 10
SIDE RAIL HEIGHT 3220 FLAT 50*6 50 6
PAD PLATE 150 PLATE 100*6 100 6

FORCES:
VERTICAL FORCE, Pv Pv = P 4776 N
MATERIALS (ASTM A36) OF SIDE RAIL OF RUNG OF SUPPORT
YIELD STRESS, Ys= 36 ksi 248.22 N/mm2 248.22 N/mm2 248.22 N/mm2

ALLOWABLE STRESSES :
TENSILE STRESS Sa=0.6*Ys 148.93 N/mm2
SHEAR STRESS Ss=0.4*Ys 99.29 N/mm2
BEARING STRESS Se=0.8*Ys 198.58 N/mm2
BENDING STRESS Sb=0.66*Ys 163.83 N/mm2
SHEAR STRESS ON FILLET WELD Sw 79.50 N/mm2 (For E70XX ELECTRODE)
PROJECT : ABOVE GROUND FUEL
CLIENT : QATAR FUEL (WOQOD)
TANKS PAGE NO.: 2
ITEM DESC. : VERTICAL LADDER
PETROL & GAS CONST. CO.
JOB NO. : 18-04002 REV. NO. : 0
VERTICAL LADDER ANALYSIS FOR HORIZONTAL ABOVEGROUND FUEL TANK

INDUCED STRESSES

INDUCED STRESS ON SIDE RAIL:


TENSILE STRESS = (Pv/2)/(w*t) 7.96 N/mm2 <Sa HENCE SAFE

INDUCED STRESS ON RUNG:


SHEAR STRESS = Pv/(Pi*Ø2/4) 15.20 N/mm2 <Ss HENCE SAFE

INDUCED STRESS ON SUPPORT/BRACKET:


MAX. BENDING MOMENT, M = (P/6)*Lb 179,100 N-mm
PERPENDICULAR DISTANCE, c = w*2/3 47 mm
3 4
AREA MOMENT OF INERTIA, I = tc /12 84,691 mm
BENDING STRESS = Mc/I 98.69 N/mm2 <Sb HENCE SAFE

STRENGTH OF WELDS

STRENGTH OF WELD (RUNG TO SIDE RAIL) :


FILLET WELD THROAT, t1 4 mm
FILLET LEG SIZE (tw) 5 mm
TOTAL WELD LENGTH (Lw) 63 mm
WELD AREA, A=0.707*Lw*tw
SHEAR (fv) = Pv/2A 10.75 N/mm2 <Sw HENCE SAFE

STRENGTH OF WELD (SIDE RAIL TO SUPPORT) :


FILLET WELD THROAT, t1 4 mm
FILLET LEG SIZE (tw) 5 mm
TOTAL WELD LENGTH (Lw) 160 mm
WELD AREA, A=0.707*Lw*tw
SHEAR (fv) = (Pv/6)/A 1.41 N/mm2 <Sw HENCE SAFE

STRENGTH OF WELD (SUPPORT TO PAD PLATE) :


FILLET WELD THROAT, t1 4 mm
FILLET LEG SIZE (tw) 5 mm
TOTAL WELD LENGTH (Lw) 160 mm
WELD AREA, A=0.707*Lw*tw
SHEAR (fv) = (Pv/6)/A 1.41 N/mm2 <Sw HENCE SAFE

STRENGTH OF WELD (PAD PLATE TO SHELL) :


FILLET WELD THROAT, t1 4.24 mm
FILLET LEG SIZE (tw) 6 mm
TOTAL WELD LENGTH (Lw) 500 mm
WELD AREA, A=0.707*Lw*tw
SHEAR (fv) = (Pv/6)/A 0.38 N/mm2 <Sw HENCE SAFE