Oily Water Separator Design Calculations

This document contains calculations for the design of an oily water separator. It includes calculations of: 1) The minimum horizontal area and vertical cross-sectional area required based on the flow rate and properties of the waste water. 2) The minimum calculated length and width of the separator based on the rise velocity of oil particles. 3) The number of channels, depth, width, and overdesigned length of the separator based on the horizontal flow velocity and minimum horizontal area. 4) The required time for rise of globules and minimum retention time based on the calculated rising time and volume of the separator.

Uploaded by

Tun Naing Win
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
370 views2 pages

Oily Water Separator Design Calculations

This document contains calculations for the design of an oily water separator. It includes calculations of: 1) The minimum horizontal area and vertical cross-sectional area required based on the flow rate and properties of the waste water. 2) The minimum calculated length and width of the separator based on the rise velocity of oil particles. 3) The number of channels, depth, width, and overdesigned length of the separator based on the horizontal flow velocity and minimum horizontal area. 4) The required time for rise of globules and minimum retention time based on the calculated rising time and volume of the separator.

Uploaded by

Tun Naing Win
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

CLIENT : NIGC PROJECT NO : 7905

PROJECT : Tabnak Gas Gathering & Treating Facilities DATED : 1/1/2002


S A Z E H
CONSULTANTS
SUBJECT : Oily Water Separator Calculation REV. : A

WASTE WATER PROPERTIES


QUANTITY UNIT QUANTITY SI UNIT
Flow Rate Qm 635.18 ft3/min 0.3 m3/sec
Ambient Temperature T 40 °f
Viscosity mw 0.0152 Cp
Waste Water Specific Gravity SW 1.00
Oil Specific Gavity So 0.70
Oil Particle Size dp 0.015 cm

RATE OF OIL PARTICLES' RISE


QUANTITY UNIT QUANTITY SI UNIT
Oil Rise Velocity Vt 0.48 ft/min 0.002 m/sec

HORIZONTAL FLOW VELOCITY


QUANTITY UNIT QUANTITY SI UNIT
Horizontal Velocity VH 3.0 ft/min 0.015 m/sec

MINIMUM HORIZONTAL AREA


QUANTITY UNIT QUANTITY SI UNIT
Turbulence & Short Circulation Factor F 1.39
Horizontal Area AH 1850.2 ft2 172.0 m2

MINIMUM VERTICAL CROSS - SECTIONAL AREA


QUANTITY UNIT QUANTITY SI UNIT
Vertical Area Ac 211.7 ft2 19.7 m2

MINIMUM CALCULATED LENGTH AND WIDTH


QUANTITY UNIT QUANTITY SI UNIT
Total Wide of Oily Water Separator B 46.1 ft 14.1 m
Minimum Required Length for Separator L 40.1 ft 12.2 m
Over Design Factor for Length f 60.0 % percent

NUMBER OF CHANNELS AND DIMENSION OF OILY WATER SEPARATOR


QUANTITY UNIT QUANTITY SI UNIT
Number of Channels n 3.0 3.0
Depth of Separator D 4.6 ft 1.4 m
Corrected wide for One Channel b 15.4 ft 4.7 m
Over Designed Length of Separator L 64.2 ft 19.6 m

REQUIRED TIME FOR RISE OF GLOBULES AND RETENTION TIME


QUANTITY SI UNIT
Calculated Rising Time for Globules t1 9.65 min
Retention Time Based on Oily Water Separator Volume t2 21.40 min

FINAL DATA QUANTITY SI UNIT


COLOR LEGEND Number of Channels 3.0
REQUIRED DATA Depth of Separator 1.4 m
CALCULATED DATA Wide of Separator 14.1 m
FINAL DATA Length of Separator 19.6 m
APPROVED BY : CHECKED BY : PREPARED BY :
SHEET 3 OF 3