Project : Feature
Structure : Designed REF
Codes : BS8110 : 1985 Checked Date
Reference Calculation Output
3.6 0
DESIGN INFORMATION
BS8110:1985 Material Properties
Characteristic strength of concrete, fcu = 30 N/mm2
Table 3.1 Characteristic strength of main r/f fy = 460 N/mm2
Characteristic strength of links fyv = 460 N/mm3
Density of concrete, ρct = 24 kN/m3
Nominal maximum size of aggregate hagg = 20 mm
Durability Requirement
Exposure condition = Moderate
Fire resistance = 1 hours
Exposed % of column = Fully exposed
Column typical dimensions
Depth of column section h = 400 mm
Width of column section b = 300 mm
Floor ‐ to ‐ Floor hight = 6600 mm
For about X‐X(Major axis) and in Y‐Y direction
Condition of top end of column = Monolithic Connection
Top beam depth in Y‐Y direction = 350 mm
Adjacent top beam spans No 1 in Y‐Y direction = 0 mm
Adjacent top beam spans No 2 in Y‐Y direction = 0 mm
Condition of bottom end of column = Moment Connection
Stability of Column = Unbraced
Clear height between end restrains X‐X lox = 6250 mm
For about Y‐Y(Minor axis) and in X‐X direction
Condition of top end of column = Monolithic Connection
Top beam depth in X‐X direction = 350 mm
Adjacent top beam spans No 1 in X‐X direction = 0 mm
Adjacent top beam spans No 2 in X‐X direction = 0 mm
Condition of bottom end of column = Moment Connection
Stability of Column = Unbraced
Clear height between end restrains Y‐Y loy = 6250 mm
Reinforcement Properties
Diameter of main bars = T 16 bars
Diameter of links = T 10 bars
DESIGN FORCES [ENV(1.4DL+1.6LL+1.6CL)]
Applied direct load N = 236.8 kN
Larger moment about X‐X axis M2xx = 10.5 kNm
Smaller moment about X‐X axis M1xx = 8.2 kNm
Larger moment about Y‐Y axis M2yy = 21.5 kNm
Smaller moment about Y‐Y axis M1yy = 19.5 kNm
Shear Force in Y‐Y direction Vyy = 10.2 kN
Shear Force in X‐X direction Vxx = 4.5 kN
CHECK SLENDERNESS OF COLUMN
End Condition of Column
BS8110:1985 Top for Y‐Y direction = 2
Part 1 Bottom for Y‐Y direction = 1
Top for X‐X direction = 2
Bottom for X‐X direction = 1
Values of β for both axes
Table 3.21 & For Y‐Y direction about X‐X axis βx = 1.3
3.22 For X‐X direction about Y‐Y axis βy = 1.3
Clause 3.8.1.6 Effective height of column for about X‐X lex = βx lox
axis = 1.3 x 6250
= 8125 mm
Clause 3.8.1.6 Effective height of column for about Y‐Y ley = βy loy
axis = 1.3 x 6250
= 8125 mm
Clause 3.8.1.3 For about X‐X axis lex/h = 8125 / 400
= 20.313
≥ 10 For Unbraced Column
→ Slender
Clause 3.8.1.3 For about X‐X axis ley/b = 8125 / 300
= 27.08
≥ 10 For Unbraced Column
→ Slender
Hence the column should design as Slender column
DETERMINATION OF COVER
Grade of concrete = 30 Cover < 35
Table 3.4 Exposure condition = Moderate
Table 3.5 Fire resistance = 1 hr Cover < 20
Clause 3.3.1.3 Nominal maximum size of aggregate = 20 mm Cover < 20
Clause 3.3.1.2 Maximum bar size = 16 mm Cover < 16
Minimum nominal cover = 40 mm Cover = 40mm
Check for minimum dimension of column for fire resistance
Figure 3.2 Requirement for minimum dimension of Fully
exposed column for 1 hours fire resistance = 200 mm
≤ Minimum dimension of column
(=300 )
→ ok OK
h' = h‐ cover ‐ dia of link ‐ dia of bar/2 h' = 342 mm
= 400 ‐ 40 ‐ 10 ‐ 8
= 342 mm
b' = b ‐ cover ‐ dia of link ‐ dia of bar/2
= 300 ‐ 40 ‐ 10 ‐ 8
= 242 mm b' = 242 mm
DESIGN OF SLENDER COLUMNS
Assume 100Asc/bh = 1.10 %
Ac = ( 1‐ 0.011 )bh
= 0.989 bh
Nuz = 0.45fcuAc + 0.87fyAsc
= (0.45x 30 x ‐0.1 + .87 x 460 x 0.011 )xbh
= 17.7537 bh
= 17.7537 x 300 x 400 x10^‐3
= 2130.4 kN
Nbal = 0.25fcu b h
= 0.25x 30 x 300 x 400 x10^‐3
= 900 kN
K = Nuz ‐ N
Nuz ‐ Nbal
= 2130.4 ‐ 236.8
2130.4 ‐ 900
= 1.54 > 1 → Use K = 1
aux = βaxKh
= Kh(lex/h) /2000
2
= 1 x 400 x 20.3125 ^2/2000
= 82.52 mm
auy = βayKb
= Kh(ley/h) /2000
2
= 1 x 300 x 27.08 ^2/2000
= 110.03 mm
Madd,x = Naux
= 236.8 x 0.083
= 19.654 kNm
Madd,y = Nauy
= 236.8 x 0.11
= 26.048 kNm
Initial moment about X‐X axis Mi,xx = 0.4M1xx + 0.6M2xx ≥ 0.4M2xx
= 9.58 ≥ 4.2
= 9.58
Initial moment about Y‐Y axis Mi,yy = 0.4M1yy + 0.6M2yy ≥ 0.4M2yy
= 20.7 ≥ 8.6
= 20.70
For about X‐X axis
M2xx = 10.50 kNm
Mixx + Madd,x = 29.23 kNm
M1xx + Madd,x/2 = 18.03 kNm
emin,xN = 4.74 kNm
Hence maximum design moment about X‐X
axis for this slender column Mx = 29.23 kNm
For about Y‐Y axis
M2yy = 21.50 kNm
Miyy + Madd,y = 46.75 kNm
M1yy + Madd,y/2 = 32.52 kNm
emin,yN = 3.55 kNm
Hence maximum design moment about Y‐Y
axis for this slender column My = 46.75 kNm
For column subjected to moments and direct load
Table 3.24 N/(bhfcu) = 236.8 x10^3/( 300 x 400 x 30 )
= 0.0658
β = 0.92
Clause 3.8.4.5 Mx/h' = 29.2344 / 342
= 0.085
My/b' = 46.748 / 242
= 0.193
Hence My/h' > Mx/b' Therefore My' = My + β(b'/h')Mx
= 46.748 + 0.92 ( 242 / 342 )29.2344
= 84.8 kNm
Clause 3.8.4.5 N/(bh) = 236.8 x10^3 /(300 x 400 )
= 1.97
M/(bh2) = 84.76 x10^6 /(300 x 400^2 )
= 1.77
d/h = 342 / 400
= 0.85
BS 8110 Part 3 100Asc/bh = 0.8
Design Charts Asc = 0.8 bh/100
= 0.8 x 300 x 400 /100
= 960 mm2
8T16, will be provided Asprov = 1608.5 mm2
Minimum reinforcement
BS8110:Part 1 : Required minimum compression r/f Asc, min = 0.4xbxh/100
1985 = 0.4 x 300x400/100
Clause 3.12.5 = 480 mm2
Maximum reinforcement
BS8110:Part 1 : For vertical cast column Asc, max = 6xbxh/100
1985 = 6x 300x400/100
Clause 3.12.6.2 = 7200 mm2
Hence required r/f area Asc = 960 mm2
Required No of bars = 6 bars
Provided No of Bars = 6 bars
Maximum C/C spacing of bars = ( 400 ‐ 40 x2 ‐16 x2‐10 x2)/4
= 89.33 mm
Minimum C/C spacing of bars = ( 400 ‐ 40 x2 ‐16 x1‐10 x2)/2
= 142 mm
Design for shear
BS8110:Part 1 : Mxx/N = ( 29.23 / 236.8 ) x 10^3
1985 = 123.44 mm < 0.75h
Clause 3.8.4.6
Myy/N = ( 46.75 / 236.8 ) x10^3)
= 197.42 mm < 0.75b
vxx = Vxx/bh
= 4.5 x10^3 /( 300 x 400 )
= 0.04 N/mm2
vyy = Vyy/bh
= 10.2 x 10^3/( 300 x 400 )
= 0.09 N/mm2
Minimum of 0.8√fcu or 5 N/mm2 = 4.38 N/mm2
Hence shear check is not required OK
100As/bd = ( 100x 1608 )/( 300 x242 )
= 2.21 < 3
→ ok
400/d = 400 / 242
= 1.6529 > 1
→ Hence, 400/d = 1
Design shear stress, vc = 0.79[100As/bd] [400/d] [fcu/25] /γm
1/3 1/4 1/3
= 0.79( 2.21)^(1/3)x (1)^(1/4) x (30 /25)^(1/3) /1.25
= 0.875
Vd/M = 0.03 < 1
→ Ok
vc' = vc + 0.75 (N/Ac)(Vxd/M)
0.87 ≤ Min(0.8√fcu or 5 N/mm )
2
=
= 0.87 N/mm2
v = V/bvd
= 0.14 N/mm2
< Vc'
BS8110:Part 1 : Containment of reinforcement
1985
Claus 3.12.7.1 Minimum diameter of link = Maximum of (0.25 x dia or 6mm )
= 6 mm → OK
Maximum spacing of links = 12 x dia of bar
= 192 mm
Hence suitable shear links spacing T 10 @175 mm
3.1.5.1.6 SUMMARY OF REINFORCEMENT
Main reinforcement bars = 8T16, Nos
Shear links required = T10 @ 175 mm
NAME column
NAME2 c7
h 400 beam 350
b 300 beam 350
hei 6600
As provide
T25 0 0
T20 0 0
T16 8 8T16, 16
T12 0 0
17.5
7.3
18.5
8.6
5.8
6.8
As provide 1608.495
175