0% found this document useful (0 votes)
1K views6 pages

BBU3910 Specifications

The document describes a BBU3910, which is a 19-inch wide, 2U high baseband unit (BBU) that can support up to 72 cells and a throughput of 10 Gbps. It consists of several subsystems including baseband processing, power, transmission, interconnection, control, monitoring, and clock. Key components include the main control and transmission unit, power module, and fan. The BBU provides ports to connect transmission equipment and performs functions like data processing, resource management, and maintenance.

Uploaded by

ramos_lisandro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views6 pages

BBU3910 Specifications

The document describes a BBU3910, which is a 19-inch wide, 2U high baseband unit (BBU) that can support up to 72 cells and a throughput of 10 Gbps. It consists of several subsystems including baseband processing, power, transmission, interconnection, control, monitoring, and clock. Key components include the main control and transmission unit, power module, and fan. The BBU provides ports to connect transmission equipment and performs functions like data processing, resource management, and maintenance.

Uploaded by

ramos_lisandro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

BBU3910

Exterior

A BBU has a case structure, 19 inches wide and 2 U high.


The following shows the exterior of a BBU.
Figure 1 BBU Exterior

A BBU is labeled with an electronic serial number (ESN). The following figure shows the ESN position on
the BBU.
• If there is a label on the FAN unit in a BBU, an ESN is printed on the label and a mounting ear of the BBU,
as shown in the following figure.
Figure 2 ESN position 1

• If there is no label on the FAN unit in a BBU, an ESN is printed on a mounting ear of the BBU, as shown in
the following figure.
Figure 3 ESN position 2

NOTE:An ESN is a unique identifier of a device and is used during base station commissioning.

Working Principle

A BBU consists of the following subsystems and each subsystem consists of different modules.

• The baseband subsystem consists of the baseband processing unit.


• The power and mechanical subsystem consists of the backplane, fan, and power module.
• The transmission subsystem consists of the main control and transmission unit as well as the transmission
extension unit.
• The interconnection subsystem consists of the main control and transmission unita as well as the
infrastructure interconnection unit.
• The main control subsystem consists of the main control and transmission unit.
• The monitoring subsystem consists of the power module and monitoring unit.
• The clock subsystem consists of the main control and transmission unit as well as the satellite card and clock
unit.
NOTE:a: In the interconnection subsystem, a UMPT is used as the main control and transmission unit.
The following figure shows the working principle of a BBU.

Figure 4 BBU working principle

Function

A BBU performs the following functions:

• Provides ports for connecting to the transmission equipment, RF modules, base station signal sources, USB
devicesa, external reference clock, and LMT or U2020 to transmit signals, perform automatic base station
software upgrade, receive reference clock signals, and support maintenance on the LMT or U2020.
• Manages the entire base station system. The management involves the uplink and downlink data processing,
signaling processing, resource management, and operation and maintenance.

Figure 5 Slots Available in the BBU3910


Capacity specifications

Item SRAN13.1 Specifications

• When configured with an LMPT: 18 cells (2T2R/2T4R/4T4R, 20 M


Hz)
• When configured with a UMPTa/UMPTb: 36 cells (2T2R/2T4R/4
Max cells per BBU
T4R, 20 MHz)
• When configured with a UMPTe: 72 cells (2T2R/2T4R/4T4R, 20
MHz)

• When configured with an LMPT: The uplink data rate at the MA


C layer is 300 Mbit/s; the downlink data rate at the MAC layer is
450 Mbit/s.
• When configured with UMPTa/UMPTb1/UMPTb2 boards
▪ One UMPTa/UMPTb1/UMPTb2: The sum of uplink and downlin
k data rates at the MAC layer is 1.5 Gbit/s.
▪ Two UMPTa/UMPTb1/UMPTb2 boards(1): The sum of uplink and
Max throughput per FDD eNodeB downlink data rates at the MAC layer is 3 Gbit/s.
• When configured with UMPTb3/UMPTb9 boards
▪ One UMPTb3/UMPTb9: The sum of uplink and downlink data ra
tes at the MAC layer is 2 Gbit/s.
▪ Two UMPTb3/UMPTb9 boards: The sum of uplink and downlink
data rates at the MAC layer is 4 Gbit/s.
• When configured with a UMPTe: The sum of uplink and downlin
k data rates at the MAC layer is 10 Gbit/s.

• When configured with an LMPT: 5,400


• When configured with a UMPTa/UMPTb: 10,800
Max UEs in RRC Connected mode
• When configured with UMPTe boards
per FDD eNodeB
▪ One UMPTe: 14,400
▪ Two UMPTe boards: 28,800

• When configured with an LMPT: 16,200


Max DRBs per FDD eNodeB • When configured with a UMPTa/UMPTb: 32,400
• When configured with a UMPTe: 43,200
Signaling specifications

Board Combination SRAN13.1 Specifications

1 LMPT + 2 LBBPc 126,000

1 LMPT + 1 LBBPc + 2 LBBPd3 216,000

1 UMPTb + 2 LBBPd3 288,000

1 UMPTb + 1 LBBPc + 2 LBBPd3 351,000

1 UMPTb + 2 UBBPd5 792,000

1 UMPTb + 1 LBBPd3 + 2 UBBPd5 936,000

1 UMPTb + 1 LBBPc + 1 LBBPd3 + 1 UBBPd5 603,000

1 UMPTb + 4 UBBPd5 1,440,000

1 UMPTb + 1 LMPT + 1 LBBPc + 1 LBBPd3 + 2 UB


999,000
BPd5

2 UMPTb + 1 LBBPc + 1 LBBPd3 + 1 UBBPd5 603,000

Equipment specifications

Item Configuration SRAN13.1 Specifications

Input power UPEUd -48 V DC

Voltage range UPEUd -38.4 V DC to -57 V DC

Dimensions (H x W x D) - 86 mm x 442 mm x 310 mm

• 15 kg (full configuration)
Weight -
• ≤ 7 kg (typical configuration)

Heat dissipation capability FANd 1000 W


Item Configuration SRAN13.1 Specifications

FANe 1000 W

• Long-term operation: -20ºC to +55ºC


Operating temperature -
• Short-term operation: +55ºC to +60ºC

Relative humidity - 5% RH to 95% RH

Ingress protection rating - IP20

Atmospheric pressure - 70 kPa to 106 kPa

ETS 300 753 3.1


Noise sound power level -
≤ 7.2 bels