THE INSTITUTION OF CIVIL ENGINEERS
GESMM3 EXAMPLES
MARTINBARNES
tT troMAs TELFoRD, LoN DoN, r es2
Published forthe lnstitution of Civil Engineers by Thomas Telford Services Ltd, Thomas Telford
House, l Heron Ouay, London E144JD.
Firstedition 1986
Second edition 1992
Terms used in this book include terms which are defined in the ICE Conditions of Contract and in
settlement of d isputes a r¡sing in the cou rse of civil eng ineer¡ng contracts.
This g uide and the statements made or opinions expressed therein is published on the
undeistanding thatthe author is solely responsible forthe opinions expressed in ¡t and that its
publication does not necessarily imply that such statements and or opinions are or reflect the
views or opinions of ICE Council or ICE committees.
@ The lnstitution of Civil Engineers 1992
Br¡tish L¡brary Catalogu¡ng in Publ¡cation Data
Barnes, Mart¡n
CESMM3 examples
l. T¡1le
624.1
ISBN:07277 16573
All r¡ghts, including translation, reserued. Except forfa¡r copy¡ng, no part ofth¡s publ¡cation may be reproduced, stored in a
retrieval system, ortransmitted in any form or by any means electron¡c, mechan¡cal, photocopy¡ng, recording or otheMise,
without pr¡or wr¡tten permission being obtained from the publ¡sher.
Typeset by Opus Magaz¡n€s, London
Pr¡nled and bound in Great Br¡tain by Staples of Rochester, Kent
CONTENTS
lntroduction
Diagrams 3
Example billof quantities pages 17
Class A: General items. 19
Class B: Ground investigation, 26
Class C: Geotechnical and other specialist processes, 29
Class D: Demolition and site clearance, 31
Class E: Earthworks, 32
Class F: ln situ concrete,36
Class G: Concrete ancillaries, 39
Class H: Precast concrete, 44
Class l: Pipework-pipes, 45
Class J: Pipework-fittings and valves, 47
Class K: Pipework-manholes and pipework ancillaries, 50
Class L: Pi pework-su pports a nd protection, ancilla ries to
laying and excavation, 53
Class M: Structural metalwork, 56
Class N: Miscellaneous metalwork, 57
Class O: Timber,58
Class P: Piles, 60
Class O: Piling ancillaries, 64
Class R: Roads and pavings, 67
Class S: Rail track. 70
Class T: Tunnels. 72
Class U: Brickwork, blockwork and masonry. 75
Class V: Painting, 78
Class W: Waterproofing. 79
Class X: Miscellaneous work, 81
Class Y: Sewer and water main renovatíon and ancillary works, 84
Class Z: Simple building works incidental to civil engineering works. 91
INTRODUCTION
INTRODUCTION
The Work Classifìcation divides the work which is covered by the
CESMM into twenty-six classes lettered A to Z. Each class contains
three types of information: an 'includes and excludes' list, a
classification table and a table of rules.
The includes and excludes list is given at the head of each class. It tells
the user of CESMM3 which general types of work are included in a
class and which classes cover other similar work which is excluded
from that class. In some cases, e.g. in classes A, C, D, I and V, the
scope or coverege of the items in a class is also given. These lists should
not be regarded merely as an index to CESMM3; they are important
to the interpretation of the coverege of the bill items generated by the
classes. Clearly the lists do not set out to be comprehensive; they do
not mention everything which is included or everything which is
excluded.
The classification table is the tabulation of the work components
covered by a class, divided into the three divisions es described in
section 3. The horizontal lines in the tabulation indicate which lists of
features from one division apply to which features in the other
divisions. This is usually straightforward, but must be given close
attention where the lines ate at different levels in the different
divisions. Headings are given in some lists of features and are printed
in italics in CESMM3. They should be included in item descriptions in
all cases where they would not duplicate information. For example,
the heading 'Cement to BS 12 or BS 146'is obviously essential in the
descriptions for items F 1-3 * 1-4 covering provision of concrete as
otherwise the information about cement is not given.
In many places the classification table uses the word'stated'in phrases;
such as 'Formwork : stated surface features' and 'Width: stated
exceeding 300 mm'. Written in full these phrases mightbecome: 'This
item classification is for formwork which has a particular surface
feature. Descriptions of items in this classification shall state the
Particuler surface feature required' and'This item classification is for
things the width of which exceeds 300 mm. Descriptions of items in
this classifìcation shall state the actual width of the things required'.
The rules on the right-hand peges ere as important as the classification
tables. In one sense they are more important as sometimes they
overrule the classification table. The rules ere errenged alongside the
sections of the classification to which they apply. This is indicated by
the horizontal lines which align from the left- to the right-hand pages.
Rules printed above a double line apply to all items in a class (see
paragraph 3.11).
The terms which are printed in italics in the rules are those which are
CESMM3 EXAMPLES
taken directly from the classification table. This style of printing is
adopted as an aid to cross-reference between the tables and the rules; it
has no effèct on interpretation of the rules.
CESMM3 uses some untraditional terms. They are adopted to
comply with British Standards or to keep up with the move to
standardize units and terms under the general umbrella of metrication.
Thus pipes have a bore not a diameter, because the bore is the diameter
of the hole down the middle, and cannot be confused with the outside
diameter of the pipe. Mass is the measure of the quantity of matter;
weight is no longer used. CESMM3 refers to weight in only one place
where it was considered that the alternative phrase'piece mass' would
be totally unfamiliar. The abbreviation for number is'nr'.
Example bill pages are given in this book for each class in the Work
Classification. The examples are not taken from actual contracts.
They can be used as a guide to the layout and style ofbills and bill items
compiled using CESMM3. The example bill items, not being related
to a particularjob, show less non-standard description amplifying the
basic descriptions than is given in real bills. Similarly, in order not to
imply that particular specifìcation details are recommended, item
descriptions in the example bills frequently refer to hypothetical
specification clauses by a clause number or to details on hypothetical
drawings. This procedure is permitted in real bills by paragraph5.l2
but it is not adopted in them to the same extent as it has been in the
example bill pages.
The examples use the code numbers in the'Work Classification as item
numbers. This practice is recommended but is not a requirement of
CESMM3. It is adopted at the discretion of the bill compiler in
accordance with paragr aph 4.3.
The examples do not cover all the items which cóuld be generated by
CESMM3 or even all the items which might occur in one bill. They
give hypothetical items which demonstrate those applications of the
rules in CESMM3 which are novel or would benefit from
demonstration for other reasons. The items are laid out as ifthey were
pages from a bill to demonstrate layout, numbering and the use of
headings. The examples illustrate the alternative procedures open to
bill compilers where CESMM3 permits alternatives. Compilers of
real bills should try to be consistent, not to demonstrate all the possible
alternatives as the examples do.
Each heading and item description in the example bill pages ends with
a full stop. This is a helpful discipline when there are two or more
headings ât the top of one bill page. The full stops help to relate the
headings to the lines drawn across the description column which show
which items apply to each heading (see paragraph 5.9). Within item
descriptions, a semicolon has been used to separate basic from
additional description.
:!t
DIAGRAMS
Original Surface and
Fig. 1. Application of the definitions
Commencing Surface of the four surfaces given in
for item A paragraphs 1 . 1 0-1 .1 3. The Excavated
Surface for one item becomes the
Commencing Surface for the next
item if excavation is measured in
more than one stage (see also
Maximum Work measured in paragraph 5.21)
depth item A
ilem A
Surface
item A and
Commencing
Surface for item B
'l
t-
Maximum I tt"me I
deplh
item B
lr
L--_J
Final Surface and
Excavated Surface
for ¡tem B
Commencing
Fig. 2. Three items are required for
this excavation. Aìl ôan be described
as 'maximum depth 10- 15 m'.
Definition rules 1.12 and 1.13 do not
require intermediate surfaces to be
Other solt material identified
Other soft material
Excavated
Fig. 3. Classification table for pipes in
class l. This is the simplest table in
CESMM3 and shows clearly how the
three divisions of classification
combine to produce brief
descriptions and code numbers for
groups of components of civil
engineering works. ln this case the
brief descriptions are amplified in bills
of quantities by more specific
information given in accordance with
CLASS l: PIPEWORK- PIPES the additional description rules in
class I
lncludes: Provision, laying and jointing of pipes
Excavating and backfilling pipe trenches
Excludes: Work included in classes J, K, L and Y
Piped building services (included in class Z)
FIRSTDtvtStON sEcoND DrvlsloN THIRD DIVISION
l Claypipes m Nominal bore: not exceeding 200 mm 1 Not in trenches
2 Concretepipes m 200-300 mm 2 ln trenches, depth: not exceeding 1.5 m
3 lron pipes m 300-600 mm 3 1.5-2 m
4 Steelpipes m 600-900 mm 4 ?-2.5 m
5 Polyvinylchloride pipes m 900-1200 mm 5 2.5-3 m
6 Glass reinforced plastic pipes m 1200-1500 mm 6 3-3.5 m
7 Highdensitypolyethylenepipes m 1500-1800 mm 7 3.$4m
8 Medium density polyethylene p¡pes m exceed¡ng 1800 mm 8 exceeding 4 m
5
CESMM3 EXAMPLES
GLASS C
ADDITIONAL
MEASUREMENT RULES DEFINITION RULES COVERAGE RULES DESCRIPTION RULES
M1 The Commencing Surface Dl Drilling and excavat¡on for Cl ltemsforwork¡nth¡sclass
adopted ¡nthe preparat¡on ofthe work in this class shall be deemed shall be deemed to include
B¡ll of Ouant¡t¡es shall be adopted lo be in mater¡al other than rock or disposal ofpxcavated material and
for the measurement of the an if i cia I ha rd m aferial un less removal of dead services.
completed work . otherw¡se stated ¡n ¡tem
descript¡ons.
M2 The depths of grout holes,
holes for ground anchorages and
drainsshall be measured along
the holes irrespective of
inclination.
M3 Drilling through previously Al The diameters of holes shall
grouted holes in the course of be stated in item descriptions for
stage grouting shall not be drilling and dr¡ving for grout holes
measured. Where holes are and grout holes.
expressly requ¡red to be
extended, the number of holes
shall be measured and drilling
through previously grouted holes
shall be measured as drilling
through rock or aft¡ficial hard
material.
M4 The numberofstages
measured shall be the total
number of grout¡ng stages
expressly required.
Fig. 4. The layout of the classified
rules in CESMM3: note the different
style of each of the four types of rule,
the horizontal alignment and the use
of the double horizontal line to
separate rules of general applicat¡on
Section A. List of principal quant¡t¡es to the class
Section B. Preamble
Section C. Daywork Schedule
Section D. Work items
Part 1. General items
Part 2. Outfall
Part 3. Plowden treatment works
Part 4. West branch sewers
Part 5. East branch sewers
Part 6. Whettleton pump¡ng stat¡on
Section E. Grand Summary
Fig. 5, Example of the standardized
Section A. List of principal quanl¡t¡es
sequence of contents of a bill of
quantities which results from Part 1 . General items
application of paragraphs 5.2 and 5.8. Provisional Sums 40 000 f
Sections of the Bill are identifled by Prime Cost ltems 165000Ê
the letters A to E to distinguish them Pa¡t 2. Outfall
from the numbered parts into which Excavation 4 000 m3
the work items themselves are Filling 1 000 m3
Concrete 850 m3
divided
900 mm steel pipework 200 m
Part 3. Plowden treatment works
Excavation 23 000 m3
Filling 8 000 m3
Concrete 9 000 m3
Pipework 1 200m
Part 4. West branch sewers
Pipelines 8000m
Manholes 40 nr
Part 5. East branch sewers
Pipelines 9000m
Manholes 50 nr
Part 6. Whettleton pumping station
Excavation 2:þO m3
Fig. 6. Example of a list of principal Filling 400 m3
quantities compiled to comply with Concrete 600 m3
paragraph 5.3
I
DIAGRAMS
E421 E422 842 nal Surface Fig. 7. CESMM3 does not divide
excavation ¡nto depth bands (a), but
1
according to total depth (b)
2 8424
E 8425
¿_
*o5
o
o 8426
Final
.l
0
(a)
Or¡ginal Surlace
2
E E4 26
Ë.
o-
o
ô
Final Surface
10
(b)
Amount Fig. 8. Column layout described in
Numbor Item doscr¡pt¡on Rato
f p paragraph 5.22 and typing capacity of
the columns when a typewriter
x999.99 Description line max 34 cha¡acters sum 999999 producing ten characters to the inch
m2 99999.9 o.99 sis used
o
) Fig. 9. Time based graph showing
6
how the payment of the Adjustment
D
o Item sum relates to the tendered
o
oc value of work items. lt illustrates the
o effect of paragraph 6.4
o Work items (a) When the work items do not reach
o
o
o
their tendered value
c Adjustment
o
o
ùo
T¡me
o
l
E 100
þo
o
E
c
o Work items
o (b) When lhe work items exceed
o their lendered value
ol Ad justment
6
c
o
o
o
G
Time Completion
7
CESMM3 EXAMPLES
Fig. 10. All prices against items in Work items
bills of quantities compiled using
CESMM3 have an assumed Related to quantit¡es Relationship specif ied
.relationship to cost. This relationship
is either to quantities which can be
observed in the physical work itself
(quantity-proportional unit rates), to
time (Time-Related Charges) or to Spec¡f ¡ed requ¡remenls Method- Related Charges
neither quantity nor time (Fixed Fixed Time Ouantity Fixed Time
Charges). This figure shows where related related related
the items which embody these three
relationships are to be found in
CESMM3
Fig. 11. Zones of inclination for grout
hole drilling and driving given in the
second division of class C, item
codes C 1-3 1-5 *. Notice the
precise boundaries for the zones. For
example, drilling at 45'to the vertical
upwards is in zone 4, drilling at 45" to
the vertical upwards is in zone 5
.::¡
@ @
:' 45'
@ @
o
Fig.12. These ridiculously shaped
structures, which are to be
constructed after excavation for them
has been carried out, demonstrate
the application of rules M6 and M16.
The volume measured for excavation
is the volume bounded by the double
line. The volume measured for
backfilling, if required, would be the
part of this volume not occupied by
the finished structure
t
DIAGRAMS
235 a.o.d Fig. 13. The volume measured for
232 e.o.d.
excavat¡on below water is that which
is below water at the higher
Excavated anticipated level
volume
at 235 a.o.d.
Boundary at 232 a.o.d.
b Fig. 1 4. The general case of the cut
and fill operation. When a composite
Dispose a earthmoving operation such as that
represented here is to be measured,
%,,o care must be taken to ensure that
enough quantities are measured in
the field to enable the quant¡t¡es
against the bill items to be calculated
e
lmport d
ililtililt
9
CESMM3 EXAMPLES
mm
B
500 600
0.1 o4 09 1.1 1 1.3 1 4 1.5
m
mm2
A
o Ø @ 2500 @ 10
Not exceeding 0.03 m2 003-0 1 m2 0 1-0'25 m2 0 25-1 m2 Exceeding 1 m2
m
0.1 o2 03 o.4 0.5 06 07 0.8 0.9 10 111 1.3 1.4 1 5
mm
Fig. 15. Nomogram for areas of
cross-section of rectangular columns,
beams, piers and casing to metal
sections. lf a straight edge ¡s placed
from the breadth dimension on scale
B to the depth on scale D, the
intersection on scale A shows the
range from CESMM3 in which the
cross-sect¡onal area of the
component occurs. lf the intersection
is very close to a range boundary, it is
necessary to check by calculation
Fig. 16. lllustration of rule M2(e).
Formwork ig measured for the
surface AB but not for the surface BC
45'
Earth or other matter
10
i,
DIAGRAMS
@ q, Fig. 17. lnclination zones for plane
Àt o o formwork defined in rules M2(e), M3,
o + o
o o o D1 and 42. Note the precise
o o-
boundaries of the zones. For
@ @ example, an inclination of 10" to the
@ vertical is in zone 3; an inclination of
1OVz" is in zone 2
10' @
5" o
3
Hor¡zontal
o 15' á
o
x
15"
5
45'
10" 10'
@
@
Þ ú
o o Formwork s¡de
o o
o- o
o_ o
@ @ @
Fig. 18. lnserts classified according to
rule A1 5. The fourtypes of insert are
shown illustrating their different
effects on wall formwork. The figure
The simple case requiring
no additional descr¡ption viewed on its side illustrates the
same points for slab formwork
(a) Proiecting from one
surface of lhe concrele
(b) Projecting from both
surfaces of the concrete
(c) Wholly within lhe concrete
11
CESMM3 EXAMPLES
Manhole B
Fig. 19. Measurement of pipe trench Commencing Manhole A
Surface
depths. The depths of pipe trenches
are given in zones (measured to pipe
invert level). Thus any variation in
trench depth at remeasurement Zone
shows itself as a change to the Depth 2
lengths of pipe which occur in each
15m __--- =.--- a
depth zone
2m
.---
4
25 m -
...- 5
3m_
35 m 7
-
4m- _-
-u-l3 --'/
3,5
Fig. 20. Simplified example showing Ppe b Ppe a lnvert raised 250 mm
how remeasurement of an pipe run in Ppe b Ppe lnvert lowered 250 mm
depth zones deals with variations in 80m
pipe trench depths
Zone
Depth
2
15m
J
2m
4
25 m
5
3m
6
35 m
7
4m
o
P¡pe Length in zone: m
run 2 3 4 5 6 7
a 10 20 20 20 10
b 20 20 20 20
c 10 20 20 20 10
Fig.21 . Dimension used in
calculating nominal trench widths for
multiple bore ducts and twinned
pipes. This is described in rules D1
and D7 of class K and 43, M2 and D1
of class L. The dimension is referred
to as the 'distance between the
inside faces of the outer pipe walls'
12
tL
DIAGRAMS
Driven pile Bored pile Fig.22. Measurement of piles. At
least two bill items are given for each
group of preformed concrete, timber
or isolated steel piles: number of
-r piles of a stated length and depth
driven. At least three bill items are
given for each group of cast in place
Pile piles: number of piles, concreted
length
Depth
length and depth bored or driven
bored Pe stating the depth of the deepest p¡le
or driven length in the group. These items are
generated by the third division of
classification of class P and
associated rules.
900 mm
Fig. 23. Awall with these surface
I -t
-l features could be considered as of
thickness 900 mm with 200 mm x
200 mm projections oras of thickness
1 100 mm with 200 mm x 200 mm
\ rebates. Additional description must
ì\ be given when work such as this-
straddling the boundary of two parts of
the Work Classif ication is to
- of be
measured. This is the effect
paragraph 5.13. The wall in the figure
should be identified using additional
þ0" description to avoid uncertainty
t- 1100 mm
t- -l
13
CESMM3 EXAMPLES
Fig.24.lnclination zones used for @
classification of Painting and
waterproofing of plane surfaces of
width exceedrng 1 m as given in the @
third division of classes V and W. (See
also rule M2.) Note the Precise
boundaries of the zones. Forexample,
a soff it surface inclined at 60'to the
horizontal is classed in zone 4; one
inclined at 61" is classed in zone 3'
on V)
Side painted
or waterproofed
@
Fig.25. Skirting boards are measured
as a single item where theY have the
same characteristics but different
. shapes (rule A4). These skirting
boãrds have the same dimensions but
two different shaPes
14
I[,
DIAGRAMS
L Fig.26. Rule M3 simplifies the
measurement of diagonal strutting.
The length measured is 2 x L rather
thanS x /
Joist Strut
Walls Fig.27 .lnclination zones used for
classification of boarding and
insulation (rule D4) and surface
finishes, linings and partitions
exceeding 1m wide (rule D7). Notethe
precise boundaries of the zones. For
example, a sloping uppersurface
inclined at 75" to the vertical is classed
inzone2; one inclined at 76o is classed
in zone 1
<Í)
o
o
o
=
I
Walls
xXXXXXXxxxxxX)a Side to be boarded, insulat€d or finished
15
EXAMPLE BILL OF OUANTITIES PAGES
GENERAI ITEMS
Number Item descrlptlon Unlt Gluantlty Rate Amount
Ê P
PÀRT I : GRNERÀT, rTRMS -
a^ñ+r-^+ri-1 raarll rananf ¡
At- 10 Performance bond. sum
A120 Insufance of the hlorks sum
À130 Thlrd party lnsurance. sum
Speci fi ecl requi rements.
A211.1 Establlshment and removal of offices for
the Engineer's staff. sum
Azrt.2 Maintenance of offices for the
Engineer's staff. sum
A211.3 Maintenance of offices for the EngJ-neer's
staff after lssue of the substantlal
Completion Certlflcate. wk 20
A¿Lz.Z Establishment and removal of laboratorles
for the Engineerts staff. sum
A2r2.2 Maintenance of Ìaboratories for the
Engineer's staff, sum
A227.1, Transport vehicle; as Speclfieatlon
clause 184 .9. wk 2ii8
A22r.2 Transport vehlcle; as Speciflcatlon
clause 184.9 for use after lssue of
SubstantlaÌ CompJ-etIon Certiflcate. wk 20
A229 Set of progress photographs comprisl-ng
six prints. nr 200
Equipment for use bv the Englneerts staff-
A231.1 Establlshment and removal of offlce
equlpment. sum
A23r.2 Malntenance of offlce equipment. sum
A231.3 Malntenanceof offlce equlpment after lssue
of Substantlal Completlon Certlflcate. wk 20
A232,L Establishment and removal of laboratory
equlpment. sum
A232,2 Malntenance of laboratory equipment. sum
A233. I Establlshment and removal- of surveylng
equipment. sum
A233.2 Maintenance of surveying equipment. sum
PAGE
19
CESMM3 EXAMPLES
GENERAI ITEMS
Number Item descrlptlon Unlt Ouantlty Rate Amount
E p
Qna¡l fI aâ ranrri rêñÃñtê
A242 Attendance upon the Engineer, s staff,
chainmen. wk 104
A243 Attendance upon the Engineer, s staff,
laboratory assistants . wk 104
A250 teéttng of material-s; concrete test cubes;
samples and methods of testlng as
Speclfication clauses 186.1 to 186.9 nr 400
Testing of the Works-
A260.L Clay pipes normaL bore not exceedlng
200 mm, test as Specification clause 18?.1 sum
A260.2 Clay plpes nominal bore 200 - 300 mm,
test as Speclficatlon cl-ause 187.2 sum
A260.3 Spun lron plpes nomlnal bore not exceedlng
200 mm, tesL as Speclfication clause 18?.3 sum
A260 .4 Spun iron plpe nominal- bore 200 - 300 mm,
test as Speciflcation clause 187"3. sum
A260.5 Àeration tanks; watertightness test as
Specificatlon clause 188. L. sum
A260,6 FInaI settllng tanks; watertlghtness test
as Speclficatlon clause 189.1 sum
A260,'l Storm tanks; vratertlghtness Èest as
Speclficatlon cLause 190. 1 sum
Tempora ry útlorks .
A2?L.L Traffic dlverslons. sum
A2'12.L Traffic regulatlon; establ-ishment and
removal. sum
A212.2 Trafflc regulatlon; continuLng operatlon
and malntenance. wk 104
A273.L EstabLishment and removal of access roads. sun
A2'13.2 Maintenance of access roads. sum
A2't6.L EstabÌlshment and removal of pumplng plant. sum
A2't3.2 Malntenance of access roa.ds. wk 104
A27 6.I EstabLishment and removal of pumping plant. sum
A27 6.2 Operatlon and malntenance of pumping planÈ. h 500
A277.L Establlshment and removal of de-waterlng
pÌant. sum
A2't1 .2 Operatlon and maíntenance of de-vraterlng
plant. wk L'l
PAGE
20
EXAMPLE BILL OF OUANTITIES PAGES
GENERÀI ITEMS
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
Method-Rel ated Charges.
Àccommod¡tl on and hui I dl ngs.
A311.1 Set up offices; Flxed. sum
A31 I .2 Malntaln offlces for the duratlon of
conétruction; Tlme-Related. sum
A311.3 Remove offlces; F1xed. sum
À314.1 Set up stores and materials compound;
Flxed. sum
À314.2 Remove stores and materlals compound;
Fíxed. sum
A315.1 Set up canteens and messrooms; Flxed. sum
431 5.2 Operate canteens and messrooms for the
duratlon of construction; Tlme-Related. sum
Servl ces.
A32 1 Set up electrlclty supply and standby
generator; Flxed. sum
A322 lìlater suppJ-y for the duratlon of
constructlon; Tlme:Related. sufn
A325 Slte transport for the duration of
constructlon comprlslng oire 5t truck and
two tractors and trailers; Time-Related. sum
A32'l ûùelfare facllltlescomplylng wlth IISAW
regulatlons for the duratlon of
constructlon; Tlme-ReLated. sum
P.Ia.oL
35t crane for erc:v:t{on ¡nd concrctlno
of main tanks
A331.1 Brlng to Slte; Flxed. sum
A331 .2 Operate; TIme-Related. sum
A331.3 Remove; Flxed. sum
Curpldd W tendeø PAGE
21
CESMM3 EXAMPLES
GENERAI ITEMS
Number Item descrlptlon Unlt Qtnntlty Rate Amount
E p
Team comprisino two pusher/ripper
bulIdozers. six mot-or scrâoêrs and one
-^-a-la¡ h'rl ì i^-^- f nr n¡ { n omh¡nl¿mant
shale fIII1no
A333. 1 Bring to Slte twlce and remove twice;
rtxéd. sum
A333 .2 Operate i Tlme-Rel,ated sum
A33 9. 1 Brlng to Slte and remove Jacks and other
prestressing plant for st¡essl-ng brldge 12
deck beams; Fixed. sum
ù339.2 Bring to Site and remove 3 grout pans and
2 grout pumps for vrork l-n items
2.8111.L to 2.8345 lncluslve; Flxed. sum
Temporârv h¡orks
Road dl,verslon at Newton Street
drrrl ngr construct I on crr'ì vert 2I b.
A351.1 Install-; Fixed. sum
A351.2 Operate and maintain; Tlme-Rel-ated. sum
A351.3 Remove; Fixed. sum
À353 Install access road, Slte entrance to
batchlng plant near downstream tunneJ-
portal-; Fixed, sum
A35 6 Pumplng as required during excavation and
concretlng of tower foundatlons;
Tlme-Re l-ated. sum
A361.1 Erect scaffoldlng surroundlng
administration bLock; Fixed. sum
A361.2 lllre of scaffoldlng surroundlng
admlnistratlon bLock from completlon of
frame until completion of brlckwork;
Tlme-ReLated. sum
Erection of falsework to support
brldge deck formwork: Í'i-ed.
A352.1 Bridgè 1.. sum
A362.2 Brldge 2. sum
A352.3 Bridge 3. sum
A362.4 Brldge 4. sum
Conrpleted W tenderct PAGE
22
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
Method-Rel ated Ch¡rges
Tenpôrary lilorks,
A363 to retaln
Temporary sheet piJ.e wall-
excavatlon on South side of Long Lane
dlversion from chainaqe L25 to 275; Fixed sum
4354.1 Make 4 sets of full height forms for
treated water reservolr columns; Fixed. sum
A364.2 Make 120 raked slde paneJ-s and 20
rectangular end panels for formwork to 3m
high 1lfÈs ln maln dam concreting; F1xed. sum
4364 .3 Use L5 m long clrcular steel- form for
linlng diverslon tunneL; lime-Related. sum
Supervlslon and labour.
À371.1 Management and supervlsion for the duratlon
of constructlon; Tlme-Related. sum
A37r.2 Addltlonal management and supervlslon
durlng constructlon of the maln pumphouse;
Time-ReIa!ed.
2 AdminlstraÉlon for the duratlon of
^31 constructlon; Time-Related. sum
A373.1 Labour for maintenance of pJ-ant and site
services during earth moving and concreting
operations; Time-Rel-ated. sum
A313.2 Labour for concreting gang durlng
concreting operatlons at main treatment
works site; Time-ReLated. sum
Cotnpletd by lenilerer PAGE TO
23
CESMM3 EXAMPLES
GENERAL I
Item descrlptlon Unlt Quantlty Rate Amount
Number I p
Þrovì sl ona'l Srrms
tleyr.tork -
50000
A4 11 Labour.
A412 Percentage adJustment to
Provislonal Sum for Daywork labour.
Materials, 25000
A4 13
A4 14 Percentage adjustment to
ProvlsionaL sum for Daywork materials
A4 15 Plant.
A41 6 Percentage adjustment to
Provislonal Sum for Daywork Plant.
SupplernentarY charges' 2000c
A4 1.?
A4 1B Percentage adjustment to
Provislonal Sum for DaYwork
supplementarY charges.
Other Provl sì onaì Sums.
a,420,t Permanent dlverslon of existing
services. 20000
LandscaPing. 25000
A420.2
5000
A420.3 Repalrs to existing tanks. 1
Repairs to existing PiPellnes' 10000
A420 . S
PAGE
24
t-
EXAMPLE BILL OF OUANTITIES PAGES
GENERAL ÏTEMS
Number Item descrlptlon Unlt Ouantlly Rate Amount
I p
Nam{ n:ta¡{ Qrih-^^ñ}
'-^+ < wh { ¡h { n¡ I rr¡la warl¡
A510. 1 Elect,ricaL installatlon. sum 50000 00
A520. 1 Labours. sum
A540.1 Other charges and profJ.t. t
A510 . 2 FIow recordlng and control equipment. sum 2 5000 00
A520.2 Labours. sum
A54 0 .2 Flow charges and profit. t
A510.3 Pumping machlnery. sum 42000 00
A530 Speclal laboursi a+-tendance on
commLssloning and testing as Speclflcation
clause 207.I, carrled out upon completion
of pump lnstalLatlon. sum
A54 0 .3 Other charges and proflt. t
It^ñ.1 - '+ ^i r: ¡f c urì+ i ¡h ¡la naÈ
lnelude work on the Site.
4610. 1 Precast concrete brldge beams. sum 3 7000 00
A620. 1 Labours. sum
4640. 1 Other charges and proflt. t
¡.61,0.2 Precast concrete fltter wall units sum 12000 00
A620.2 Iabours. sum
A640.2 Other charges and proflt. t
PAGE
25
CESMM3 EXAMPLES
Nurter Item descrlptlon Unlt Ouantlty Rate Amount
Ê p
B1 13 Number ln materlal other than rock maximum
depth 2 - 3 m; mLnlmum plan area at the
bottom of the excavation 2 m2. nr 6
Bt-3 0 Depth ln materlal other than rock;
mlnlmum plan area at the bottom of the
excavatlon 2 m2. m 18
B1 50 Depth supported. m 18
B1 60 Depth backflLled wtth excavated materlal. m 18
B170 Removal of obstructions. h 5
BlBO Pumplng at a mlnimum extractlon rate of
7000 litres per hour. h T2
T.TGHT CABT.E PFIRCTISSTON BORFIHOT'F]S.
Nomtn¿-L-diamete r--..at*base. -Ll0-mn.
B2L0 Number. nr I
823 1 Depthln holes of maximum dePth not
exceeding 5 m. m 20
8232 Depth ln hoLes of maxlmum depth 5 - 10 m. m 10
8233 Depth in holes of maxlmum depth 10 - 20 m. m 15
8234 Depth in hoLes of maxlmum depth 20 - 30 m. m 50
B260 Depth backfilled wtth excavated materlal 95
8270 Chlselllng to prove rock or to penétrate
obstructlons. h 10
PAGE
26
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
ROTÀRY NRTT.T,ED trOREIHOI.ES.
Mlnlmrrm core d{ameter ?5 mm.
8310 Number; continuatlons of llght cable
percusslon borehol-es. nr 2
834 3 Depth wlth core recovery In holes of
maximum depth 10 - 20 m. m 30
B3 60 Depth backfill-ed with cement grout. m 10
8370 Core boxes, core 3.0 m long. nr 4
SÀMPT,ES.
841,2 Dlsturbed samples of soft materlal from the
surface or from trlaì- plts and trenches:
mlnimum 5 kg;.C1ass 3. nr 18
B42L Opentube samples from boreholes.
100 diameter x 450 mm long, undÍsturbed
mm
sample; Class 1. nr 4o
8422 Disturbed sarnples from boreholes: mÍnlmum
5 kg, Class 3. NT 2t
8423 Groundwater samples from boreholes¡
minlmum 1 lltre. nr I
STTE TESTS ÀND ORSERVATTONS.
85 L2 Groundhrater level; taken at commencement
and end of work each day. nr I
95 13 Standard penetratlon test; in llght cable
percussion boreholes. nr 25
851 5 Vane test ln borehole. nr 5
TNSTRUMtrNTAT, OBSERVÀT ION S
Pressllrê he¡d: week'l w ollserwat lons.
'
861 1 Standplpes. m 18
B613 Install covers. 3
861 4 Standpipe readings. 9
PAGE
27
CESMM3 EXAMPLES
Number Item dæcrlptlon UnIt Quantlty Rate Amount
E p
T.AFORATORY TESTS
Cì¡sslflcatlon.
871 1 Moisture content. nt 10
B7L2 Atterberg llmlts. nr 20
B714 Particle size analysis by- sleve
871 5 Partl-cLe size analysls by plpette or
hydrometer. nr 4
Chemic¡l content
8722 SuLphate. nr 16
8123 pH vaJ.ue. nr I
Consolldati on.
874 1 Oedometer cell-. nr 6
enì I el-ranaf h
B76t Qulck undralned trlaxiaL set of three
38 mm dlameter speclmens. nr 20
Rock strength.
871 5 Point load tests on core samples as
Speclflcatlon cl-ause 8243 nr 6
PROF'ESSTONAI. SERVTCNS.
883 1 Engineer or geologlst graduate. h 5
8832 Enqineer or geologist chartered. h 15
883 3 Engineer or geologist princJ-pal or
consultant. h 5
B84 0 Vlslts to the SIte. nr 2
PAGE
28
,1
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unlt Ot¡antlty Rate Amount
E p
GROTECHNJCÀÍ, ÀNn OTI{ER SPFCIAT,IST PROCESSES.
Dr{ ì ì Ing for grout hoìes.
Iìi ameter 50 rnm.
Vert lc¡ I ll y downwards .
c111 In holes of depth: not exceeding 5 m. m 80
CLL2 In holes of depth: 5 - 10.m. m 160
c 113 In holes of depth: 20 - 30 m. m 310
c 114 In holes of depth: 20 - 30 m. m 630
c 116 In holes of depth: 50 m. m 200
,Downw¡rds ¡l- :n ¡nc'l p O' - 4 6' f n l-ha
vertlc¡'l .
cL23 In hol-es of maximum depth: 10 - 20 m. m 620
cIz4 In hoLes of maxlmum depth: 20 - 30 m. m 3300
Grout holes diameter 50 mm.
c4t0 Number of holes. nr 234
c420 Number of stages. nr 't02
c430 Slngle water pressure tests. nr 20
Grorrt materials and lnlection.
Materla l s.
c51 1 Cement; to BS 12. t 154
c512 Pulverlzed fuel ash; as Speclflcatlon
clause G420.7 . t 290
c513 Sand; to BS 1199. t 50
Tn jectlon .
c521.1 Number of lnJections; in descending stages nr 50
c52r.2 Number of lnjectlons; 1n ascendlng stages. nr 75
c522 Neat cement grout, t 25
c523.L Cement and sand grout. t 200
c523.2 Cement and pulverlsed fueL ash grout. t 269
c526 Slngle packer settLngs. nr 50
PÀGE
29
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Quantlty Rate Amount
E P
ñl:nlrr¡an w¡ll far ãñ^la^r ¡lrrnhar ¡c
.
3
c613 Excavatlon maxlmum depth 10 - 15 m. m 2400
3
c623 Excqvation in rock maxlmu¡n depth 10 - 15 m m 400
c64 0 Concrete; wlth sylphate resistlng cement
3
strength 30 N/mm¿. m 2730
c664 High yield steel bar rei.nforcement to
BS 4449 dÍameter 12 mm. t 40
c 665 Hlgh yieJ.d steel bar reinforcement to
BS 4449 diameter 16 mm. t 66
c666 Hlgh yieJ-d steel- bar reinforcement to
Bs 4449 diameter 20 mm. t 120
c670 Íüaterproofed JolnÈs; as Speclflcation
cl-ause C47. sum
c68 0 Gulde waLls. n ,A'
Temporarv oround ¡nchoraoes; East Otray wall:
hnrlznnl¡ì ln¡¡l 2? i - /*^+-o. urrta¡ r¡¿l
crnr:t teÊt i nd- brecrr 'i na :n¡l nrnrrt 1nc ¡<
Sgeclf i cat í on c-lause -W224
clLt Number maximum depth 25 m. nr 7
c't2t Total length of tendons. m 140
Sand drai ns
cB11 Number of dralns across sectlonal dlmension
not exceeding 100 n. nr 50
cB5 1 Depth of dralns of maxl-mum depth:
10 - 15 m cross sectional dimension
not exceedlng 100 mm; type C2
granular materlal, m 650
PAGE
30
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unlt Ouanflty Rate Amount
Ê P
PÀRT 5. |IEMOT.TTTON ANN SJTR CÍ.RARANCtr
D 100 General- cJ.earance. ha 27
D220 Tre'es girth 7 - 2 m¡ holes backfilled
wlth excavated mater1al. " nr 39
D250 Trees glrth exceedlng 5 m. nr 30
D320 Stumps diameter 500 mm - 1 m. nr 2t
D4L4 Bulldlngs brickwork volume 250 - 500 m3;
farmhouse at Far1ey Court. sum
D43 5 Buildings masonry volume 500 - 1000 m3;
barn at Farley Court. sum
D54 5 Other structures metal volume
500 - 1OOO m3; screenlng plant to remain the
property of the Employer. sum
D620 Plpellnes nominal- bore 300 - 500 mm. m 110
0900 Pump removed, cJ-eaned anddelivered to
Employer's depot at Church Stretton. nr 2
PAGE
31
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Quantlty Rate Amount
I Þ
EAgr¡so86.1.
81,20 Excavation by dredging; Mersey estuary
adjacent to Sandon Dock. m
3
10971
E31 1 ExcavatLon for foundations topsoil- maximum
depth: not exceedlng 0.25 m. m
3
37
8324 Excavation for. foundatlons maximum depth:
1 - 2 m. m
3
170
F'324.1 Excavatlon for foundatlons maxlmum depth:
L - 2 n¡ around piJ-e shafts. m
3
23
F.324.2 Hand excavation for foundatlons maxlmum
depth: L - 2 m; Commencing Surface
underside of blinding of outfaLl. m
3
15
General e-cavatjon
3
E415 Topsoil maxlmum depth 2 - 5 m. m 153
3
E'425 Maximumdepth2-5m. m 1 7350
8435 Rock maxlmum depth: 2 - 5 m, *3 750
F.444 Mass concrete exposed at the Commenclng
3
Surface maxlmum depth: 1 - 2 m. m 53
8454 Rel-nforced concrete not exposedat the 3
Commencing Surface maxlmum depth: L - 2 m m L12
Fl-c.¡v¡t I on anci I I arl es.
8512. 1 Trlmming of excavated surfaces. m
2
7 500
8512.2 Tr1mm1ng of surfaces; excavated by
2
dredging. m 52"tL
E552 Preparatlon of excavated surfaces. m
2
15763
PAGE TOT
32
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
EARTÍ{I¡IORKS.
E-cavat l on anc { ì I ar'l es .
8523 Preparation of êxcavated rock surfaces. m
2
5't 6
F'524 Preparation of excavated surfacesi mass
2
concrete. m 110
8532. 1 Dlsposal of excavated materlal. 2700
^3
8532.2 Dlsposal of materl-aL excavated by dredgtng. a3 10971
8542 Double handJ.lng of excavated materlal. a3 10350
E560 Excavatl-on of material beLow the Flnal
Surface and replacement with grade B
granular materiaL. *3 1 000
E570 Tlmber supports left ln. 300
^2
E580 Metal supports left ln. m
2
500
E 613 Fllling to structures. *3 527
8624 Ftlltng to embankments, seÌected excavated
material other than topsoll or rock. m3 100 ? 16
E? 12 Fllling anclllaries trlmmlng of fllled
surfaces; incllned at an angle of 10' - 45"
to the horlzontal. m
2
1054
8722 FIIlJ.ng anclJ.Larles preparatl-on of fllled
2
surfaces. m 357
PAGE
33
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
'E Excåvatlon for cuttings; topsoil. 3
E2L0 m 584
F,220.L Excavation for cuttlngs; Excavated Surface 3
0.25 m above Flnal Surface. m 105 87
F'220.2 Excavation for cuttings; Commenclng Surface 3
0.25 m above FinaL Surface, m 680
E'522 Excavatlon ancillaries preparatlon of 2
excavatÍon surface. m 5 110
E532 Excavation ancillarles disposal of
excavaÈed material; to on Site spoil heap
at locatlon A on drawing 'l/47. m
3
584
F.624 FlJ.ling embankments selected excavated 3
materlaL other than topsoiJ- or rock. m 5834
8712 Fllling ancillaries preparation of fllled 2
surfaces. m 2187
E730 Filllng ancillarles geotextlles; melded
fibre mat grade G2 lald uþon surfaces
lnclined at an angle of 1"0' - 45' to the
horizontal,. m 1250
PAGE
34
It-
EXAMPLE BILL OF OUANTITIES PAGES
SITEIT'IORKS
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
PÀRT 28. STTEVIIORKS.
TIÀRTH!ÍORKS.
E411 GeneraL excavatlon topsoll maxlmum depth:
not exceedlng 0.25 m. 3482
3
8424 General excavatlon maxlmum depth: 1 - 2 m. m 25234
8532 D1sposal of excavated materiaf. m
3
9924
E.624 F11lIng embankments selected excavated 3
materlal other than topsoil or rock. m 15310
864 1 Fllling thickness 150 mm excavated topsoil. m
2
232t3
F.642 Fllltng thlckness 150 mm lmported topsoil. a2 1 573
E711 Flll1ng anclllaries trlmming of filled
surfaces, topsoil. 1 7036
EB 1O LandscapÍng turflng 5700
E83r) Landscaping grass seeding upon a surface
inclined at an angle to the horizontal 2
exceeding 10'. m 2050
E860.1 Landscaplng oak trees exceedÍng 5 m hlgh. nr 110
EB60 " 2 Landscaping sycamore trees exceed-tng
5 m high. nr 120
PAGE TOT
35
CESMM3 EXAMPLES
STREFFORD BRÏDGE
Number Item descrlptlon Unlt Qunllty Rate Amount
E p
F14 3 Standard m1x ST4 cement to BS 12, 20 mm
aggreqate to BS 882. m
3
840
Þlaclng of concrete.
Rei nforced.
F634 Suspended sl-ab thlckness: exceedlng 500 mm;
volded bridge deck. m
3
462
8654 Col-umns and piers cross-sectlonal_ area:
0.25 - 1 m2.' m
3
96
F664 Beams cross-sectlonal area: 0 .25 - I m2. m
3
38
F665 Beams cross-sectlonal area: exceedlng 1 m2. a3 53
F666. I Beams special sectlons: type Jl
drawlng L31 /26. a3 87
8666.2 Beams speclal- sectlons: type ;I2
drawlng L37/26. m
3
104
PAGE
36
EXAMPLE BILL OF OUANTITIES PAGES
INLET WORKS
Number Item descrlptlon Unlt Quanllty Rate Amount
E p
IN STTU CONCRETE.
Provlsion of concrete. standard mlv.
F133 ST3 cement to BS 12, 20 mm aggregate
to BS. 882. m
3
350
FL44 ST4 cement to 8512, 40 mm aggregate to 3
BS 882. m t032
F14B ST4 sulphate resisting cement to
BS 4027, 40 mm aggregate to BS 382 m
3
504
8253 Provlslon of concrete designed mix for
ornamentaL surfaces grade C25 cement to
BS L2, 20 mm agg¡egate; minimum cement
content 250 kg,/mr sampling as Specificatlon 3
cLause 252. m þ3¿
Plac{ng of concrete.
F51I Mass bl-lnding thickness not exceedlng
3
L50 mm, m 97
F580. 1 Mass backfilllng around structure; beneath
lnl,et channel pJ.aced against an excavated
surface. m- 2L0
3
F5B0 " 2 Mass benchinq; wet weIls m 2T
F580 .3 Mass fill-ing to flume; inlet channel- to
3
pumping station. m 5
F580.4 Mass pllnths; 900 x 900 x 1000 mm. m
3
1
F580.5 Mass plinths; 1500 x 1500 x 1500 mm m
3
10
Rein forced.
F623.I Bases and ground sl-abs thlckness
3
300 - 500 mm. m 906
8623.2 Ground slabs thickness: 300 - 500 mm; to be
placed ln one continuous pour in fllter
3
block base. m t5
3
F 633 Suspended slabs thickness: 300 - 500 rnm m r20
F641.1 Wal-ls thickness: not exceeding 150 mm, m
3
31
864I.2 Wall-s thickness: not exceeding 150 mm;
weir wall- top finished to precise line
and level. m
3
10
?
F 642 Wal-Is thickness: 150- 300 mm. m 290
F64 3 WalLs thlckness: 300 - 500 mrn. m
3
s20
F 653 CoLumns and oler s cross-sectlonal area: 3
0.1 - 0.25 m2. m 97
PAGE
37
CESMM3 EXAMPLES
INIET WORKS
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
TN STTII CONCRETF]
Pl:clnc of conc¡ete.
F65 4 Colúmns anQ piers cross-sectlonal area:
0.25 - 1 m2.' m
3
94
F65 5 Columns and plers cross-sectional area:
exceeding I mz; column cap. m
3
10
8664 Beams cross-sectional area: 0 .25 - L m2 m
3
70
F666. 1 Beams speclal sectlons; 600 x 900 mm
(lnterna.l-) box beam, wall- thickness:
150 mm. a3 67
8666.2 Beams special sections; type J3
drawing I31 /21 . m
3
16
F666.3 Beams speciaL sectlons; type J4
drawlng L37 /21 . m
3
98
F666.4 Beams special sections; type ,15
drawing L37/2'7. m
3
66
Other concrete forms,
F'680. t Dlffuser drun thickness lS0 mm, diff::ser
type D1 drawlng t3'7/49. m
3
3
F680.2 Box cuLvert lnternaL dimenslons 1.5 x3m
wal-1 thickness: 250 mm. m
3
78
F680.3 Box culvert internal_ dimenslons 2 x 4 m
wal1 thickness: 250 mrn. m
3
104
F680. 4 Steps and stalrs thickness: 100 - 300 mm. m
3
L2
PAGE
38
EXAMPLE BILL OF OUANT IES PAGES
Number Item descrlPtlon Unlt Ouant¡ty Rate Amount
Ê p
GTL2 Formwork rough flnlsh horlzontal- wldth
0.1 - 0.2 m. m 129
c1L 3 Formwork rough finish horizontal wldth
0.2'- 0.4 m to be left in. m
2
7
Gl4 5 Formwork rough finish vertlcal. m
2
370
Gl5 5 Formwork rough finish curved to one radius
in one plane; radlus 10.5 m, back of wall 2
D drawing 1-3'l /6. m 99'7
G184 Formwork rough finish for concrete
component of constant cross-section; box
culvert internal dimensions 1.5 x 3 m wal-l-
thickness: 250 mm. m 326
tr'orrnwork fair fini sh.
G2LT Horizontal wldth not exceeding 0.1 m. m 410
G2T3 Horlzontal width 0.2 - 0.4 n. m
2
331
2
GzI5 Horizontal. m 981
G222 "r SJ-oping width G.l - 0"2 m" m 723
c222.2 Sloping wldth 0.1 - 0.2 m; upper surfaee m 27
2
e225.L S loping . m r28
G225.2 Sloping; upper surface. m
2
157
2
G235 Battered. m 429
c24l Vertical- width not exceeding 0,1 m. m 410
e242 VertlcaL width 0.1 - 0,2 m. m 924
c243 Vertical width 0.2 - O.4 m, m
2
I92
G245 VerticaI. m
2
780
c252 Curvedto one radius 1n one plane wldth
0.15 m; radius 1.0 m, column plinths. m 927
c255 Curved to one radius in one pJ-ane radius
11 . 5 m; face of wal-l- D drawing L37 / 6 , m
2
1354
2
c260.L Spherlcal radlus 2 m; fLume chamber. m 43
c260.2 Conical maximum radius 600 run minimum
radius 300 mm; outl-et chamber. m 21
c260,3 Conical maximum radius 800 mm minimum
radius 400 mm; inlet chamber. m
2
35
PAGE
39
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Ouantlty Rate Amount
E P
CONCRETE ANCTT,T,ÀRTES,
Í'ormwork fal r fì n1 sh.
G2'IL For'small voids dePth not exceeding 0.5 m. nr 15?
c212 For small voids dePth 0.5 - 1m. nr 2gs
c21 6 For large volds dePth 2.3 m. nr 76
G218.L For large volds dePth 2.3 m. nr 5
c2'18.2 For large volds dePth 2,6 m. nr L
For concrete comPonents of constant
cross-section .
c281.1 Beams; 200 x 300 mm beam 827. m 37
G28L.2 Beamsi 300 x 400 mm beam 828. m 50
c281.3 Beams; 450 x 600 mm beam 830. m 46
G282 "l Columns; 450 x 450 mm columns I '' 24" m 98
c282.2 Columns; 600 x 600 mm columns 25 - 30. m 27
c282.3 Col.umns; curved to 150 mm" radius columns
31 - 54. m 95
c284 Box culvert lnternal dlmension 1.5 x 3 m
wall thickness 250 mm beneath entrance
road. m 310
c28 5 ProJections. m 207 6
c286 Intruslons. m 15 94
c299 For diffuser drum lncluding perforatlons
as detailed on drawlng I37 /54. m 5
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unlt Quantlty Rate Amount
I p
CONCRFITE ANCTI,LÀRTES
Rel nforcernent
Pìaln round steel hars to RS 4449-
c51 1 Dlameter 6 mm. t 3.7
c5t2 Dlameter I mm. t 3.9
G5L3 Dlameter 10 mm. t 4.2
G514 Diameter 12 mm. t 4.9
G515.1 Dlameter 16 mm. t 5.7
c515.2 Dlameter 15 mrn; Iength 15 m. t 2.r
G516.1 Dlameter 20 mm. t 5.9
c5I6. 2 Dlameter 20 mm; length 15 m" t 1.0
c516 .3 DLameter 20 mm; Iength 18 m. t 0.9
G517 . t Diameter 25 rnm. t 6,3
G577 ,2 Diameter 25 mn; length 15 m. t r,2
c518 Dlameter 32 run or greater. 1,6
c526.1 Deformed hlgh yieJ-d steel bars to BS 4449
dlameter 20 mm. t 4.2
c526,2 Deformed hlgh yield steel bars to BS 4449
dl-ameter 20 mm; length 15 m. t 2.r
G528 Deformed high yleld st,eeL bars to BS 4449
diameter 32 mm or greater. t 3.9
c563. 1 Steel fabric to BS 4483 nominaL mass
3-4 kg/n2; reference 4193. m
2
3'128
c563.2 Stee.l- fabrlc to BS 4483 nominal mass
3-4 kg/m2¡ reference 4252. m
2
1807
G5 64 Steel fabrlc to BS 4483 noml-nal- mass
4-5 kq/m'; reference C503. m
2
286
PÀGE TO
41
L-_
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Quantlty Rate Amount
Ê p
CONCRRTE ÀNCTT,T,ÀRTFIS.
Joi,nt s
25 mm hitr:men impregnated fibreboard filler
G62I Open surface width: not exceeding 0.5 m. m
2
9't
c622 Open surface bridth: 0.5 -. 1 m. m 38
c64 1 Formed surface width: not exceedlng 0.5 m. m
2
107
c642 Formed surface width: 0.5 - 1 m. m
2
9B
c643. I Formed surface width: 1.2 m. m
2
21
c643.2 Formed surface wldth: 1.45 m. m
2
41
c65 I PVC centre bulb waterstop; 100 rnm wíde m 38
G652 PVC centre bulb waterstop,. 175 mm wLde m 110
c653 Rubber centre bul-b waterstop; 225 mm w1de. m 150
c654.1 Rubber centre buLb waterstop; 400 mm wide m 28
c654.2 Rubber centre bulb waterstop; 450 mm wide m 64
G670.1 Rebate sealed with 25 x 25 mm Plastic or
slmllar approved. m I25
c610.2 Rebate sealed with 25 x 25 mm PJ.astljolnt
or similar approved. m 670
G682.t Sleeved and capped dowels; 25 mm dlameter
by 300 mm mild steel bars at 0.5 m centres
as detail E drawlng I3'l/25. nr r28
c682.2 Sl-eeved and capped dowels; 25 mm diameter
by 300 mm mild steel- bars at 1 m centres
as detail E drawing L31/2þ. nr 3t_
PAGE
42
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlpt¡on Unlt Quantlty Rate Amount
I p
CONCRETR ÀNCTf .I,ÀRTRS.
Concrete ¡ccessorles.
G81 1 Flnishlng of top surfaces wood float. m
2
491 6
G812 Flnishlng of top surfaces steeL trovrel. m
2
1 0821
G814.1 Finishing of top surfaces granolithíc
finish; as Specification clause GBl05,
40 mm thick; steel trowel- surface
treatment. *2 L92
c8I4.2 Finishlng of top surfaces granollthic
flnish; as Speclflcation clause G8/05,
55 mm Èhicki steel- tror¡rel" surface
treatment. m
2
141
GB 15 Flnishing of top surfaces cement and sand
screed as Speciflcatlon clause G8,/1.2, 40 mm
thlck; steel trowel surface treatment. m
2
98
c822 Flnishlng of formed surfaees bush
hammering. *2 481
Tnserts
G83 l 100 mm dlameter GVC plpe; excludlng supply
of the pipe. m 21
c832. 1- 10 mm diametex, 25 mm deep expanding boj-t
projecting from one surface. nr 110
c832.2 15 mm dlameter, 40 mm deep rag bolt
proJecting from one surface. nr 110
c832.3 25 mm dlameter, 100 mm long mlLd steel
holdlng down bolt projectlng from one
concrete surface for scraper machlner¡y'
as detall L drawlng I38/J-'1. nr 64
c832.4 100 run diameter ductiJ.e lron plpe
proJecting frorn one surface; excJ-uding
supply of pipe. nr 10
c832.5 150 mm diameter ductile lron plpe with
puddle flange projecting from two surfaces;
excludlng suppl.y of pipe. nr 3
c832. 6 225 mm dlameter ductlle iron pipe
proJectlng fron two surfaces grouted v¡Ith
grout type G3 Into 450 x 450 mm preformed
opening; excludlng supply and flxlng of the
pipe under separate contract. nr 4
G842 Groutlng under plates area 0.1 - 0.5 m2
with type G2 grout, nr I
PAGE
43
CESMM3 EXAMPLES
BRIDGES
Number Item descrlptlon Unlt Quantlty RatE Amount
I p
PRECAST CONCRETTÌ
Ord'inary prescribed mix concrete orade C40
as Specifi cati on cl ause F 2/36.
Strefforcl Bridge fieck.
Hl13.1 Secondary beams lnverted t,ee 180 x 400 mm
length 4.25 m mass 500 kg-lt mark 81. nr 32
HTL3.2 Secondary end beams rectangular 200 x 450 mm
length 4 .25 n mass 500 kg-It mark 82. nr 4
H268 Prestressed pre-tensioned maln beams I
section 800 x 1400 mm length 23,1 m mass
31 t mark 83 prestresslng as drawing 136/21
and Specificatlon cLauses H2/2L-21. nr z
H523 Service duct cover slabs thickness 100 mm
area 1 - 4 m2 mass 500 kg-J-t mark 51. nr 28
H8 l0 Parapet coplng únlts flLleted rectangul ar
250 x 220 mm cross-sectional area 0.05 *2
mass 120 kglm mark CL. m 124
PAGE
M
EXAMPLE BILL OF OUANTITIES PAGES
SITE PIPEI,INES
Number Item descrlptlon Unlt Ouantlty Rate Amount
E p
PIPEW9BK_J.IPE.1
Clav pìpes to BS 65 with splgot and socket
f le-ibl e Jolnl s nomi na] bore 225 mm { n
treFches.
Between manhol es 7 encl I 1.
r123.1 Depth:1.5-2m. m 187
TT24.L Depth:2-2.5n. m 29r
f125 Depth:2.5:3m. m L02
Retween menholes 27 ¡nd 31
t123.2 Depth:1.5-2m. fn 113
rt24.2 Depth:2-2.5n. m 202
Þre st re.îsed-lo¡cretÈdpes_to_lS_191-l
fclass Ml wii.h ogee Jolnts nomina
375 mm,
T23T Betvùeen manholes 18 and 19 lnstalJ-ed by
thrust boring under Central ülal-es line
rallway embankment. m 98
r234 Depth:2-2.5m. m r27
r235 Depthl 2.5-3m. m 78
T23B Depth:4.5-5m. m 2t
PÀGE TO
45
CESMM3 EXAMPLES
SITE PIPELINES
Number Item descrlptlon Unlt Quantlty Rate Amount
Ê p
P-IPEWARK_- P-I!.E.I
Þrestresserl concrete p,lpes to BS 5911
l¡l¡cc Mì wifh -{^i -+ - -^-i ñ- 1
^õêê
3?5, mm.
Manhole 23 to orimary tank.
T233 Depth 1 .5 - 2 m; in trench laid alongside
second pipe. 2'7
Ducti le spun iron plpes to trS 4622 fclass 3l
with Forsoam joints nominal bore 700 mm.
I34 1 Feed plpe suppotted above the ground. m 16
r343 In trench depth 1.5 - 2 m Commencing
Surface underside of main tank slab; draw
off pipe main tank colÌector to valve
chamber. L2
134 5 In trench D depth 2.5 - 3 m bypass Pressure
maln valve chamber to circulation unlt. 33
r 346 In trench D depth 3 - 3,5 m servlce maln
valve chamtrer to circuLaLiorr unit. 33
Upvc pipgs to FS 3505 with compresslon
la'i¡f c ñ^ñiñrI Èrnra
Tn trenches.
15t2 Depth: not exceeding 1.5 m; excavatlon
by hand. m 15
r513 Depth:1,5-2m, m 150
r 514 Depth:2-3m. m 1.28
PAGE
46
\
EXAMPLE BILL OF OUANTITIES PAGES
SITE PIPELINES
Number Item descrlptlon Unlt Ouant¡ty Rate Amount
Ê p
PTÞF!{ORK - F'ITTTNGS ANN VÀÍ,VFS.
f JII2 Bends. nr 385
I Jl22 Junctlons and branches nr L27
JI32 Tapers nr 38
Prestressed concrete pipe flttlnos to-
RS 5911 (class Ml wlth ogee Joints.
J2L2 Bends; nominal bore 225 mm. nr 4T
J2r3.t Bends; nominal bore 375 mm. nr 141
J2t3,2 Bends; nominal bore 450 mm. nr 19
J2T4 Bends; nomlnal bore 825 mm. nr 41
J222 ilunctlons and branches,' nomlnal bore
225 r,n. nr 27
J223. r Junctlons and branches; nomfnal bore
375 mm" nr 't6
J223.2 ,Junctlons and branches; nominal bore
450 mm. nr I
J224 .Junctions and branches; nominaL bore
825 mm. nr 23
J232 Tapers; nominal bore 225 mm. nr 16
.I233 Tapers; nomlnal bore 450 mm. nr 16
J234 Tapers; nominal bore 825 rnm. nr 4
PAGE TO
47
CESMM3 EXAMPLES
SITE PIPELINES
Number Itom descrlptlon Unlt Quantlty Rate Amount
E p
PTPFÛÍORK - F'TTTTNG ÀNN VAT,VFS.
frrrctlle spun lron plpe fittlngs to
RS 4622 (class 3ì wlth GripDon Joints.
J31 1 Benps; normal- bore 150 mm. nr 27
J313 . I Bends; nominal bore 400 rn 22.5' effectlve
length 220 m¡; not In trenches. 1
.t31.3 . 2 Bends; nomlnal bore 400 mm 45 effectlve
Iength 400 mm. nr 6
J313.3 Bends; nominal bore 500 mm vertical 90'
effectlve length 840 mm. nr 3
J353 Adaptors; nominal bore 400 mm Grippon to
flange effectlve length 150 run. nr 6
J382. 1 Straight specials nomLnaL bore 225 mm
effective length 1220 mm. nr 1
,r-?8? ,? St:'alght speeials nomlnal bcre 225 mm
effective length 1500 mm; with puddle
flange. nr 1
J3B3 Straight speclals nominaÌ bore 400 mm
effectlve length 900 mm; not in trenches nr 3
.j393 Blank flanges; nclminal bore 400 run n! 3
Cast iron gate valves hand oPerated to
RS 3464 ltype al with evtension sPlndìes.
J813.1 400 mm nomlnal bore with T keY. 4
J813 . 2 400 mm nominal bore wlth hand wheeI. nr 2
J8r3.3 500 mm nominal bore with hand wheel. nr 3
Cast iron valves as F{oldwater Tndustries
cataloQrue numbers sçated or sìmller
agoroved.
J83 5 Double hinged flap val.ves nominal bore
1100 mm nr 890. nr 2
,tBB4 , 1 Penstocks nomlnaf bore 700 mm nr 731 wlth
handwheel- headstock and foot bracketi
invert to handwheel dlstance 2050 run. nr 6
JBSS.2 Penstocks noml,nal bore 700 mm nr 740 with
T key headstock and foot bracket; invert
to T key dLstance 3100 mm. nr 9
JB94 Sludge draw off valves nomlnal bore
700 mm nr 780. nr 3
PAGE
I
48
i
EXAMPLE BILL OF OUANTITIES PAGES
SITE PIPELINES
Number ltem doscrlptlon Unlt Ouantlty Rate Amount
Ê p
PTÞtrlfORK - F'TTTTNG ANN VÀT.VRS.
Ductlle spun lron plpe fltt{ngs to
FS 4622 (clâss 3) hrlth Grippôn Joínts.
J31 1 Bends; normal bore 150 mm. nr 27
J313 . 1 Bends; nominal bore 400 rw¡ 22.5' effectlve
length 220 n¡¡¡ not In trenches. nr t
J3T3,2 Bends; nomlnal bore 400 mm 45 effectlve
length 100 mm. nr 6
,t31.3 . 3 Bends; nomLnal bore 500 mm vertlcal 90'
effectlve length 840 mm. nr 3
.t353 Adaptors; nomlnal bore 400 run Grippon Eo
flange effective length l-60 mm. nr 6
,J382. 1 Straight specials nominal bore 225 mm
effective length 1220 mm. nr 1
J382,2 Stralght speclals nomlnal bore 225 mm
effectlve length 1500 mm; wlth puddJ.e
flange. nr 1
J3B3 Stralght speclals nomlnal bore 400 mm
effectlve J.ength 900 mm; not in trenches. nr 3
,r393 Blank flanges; nomlnal bore 400 mm. nr 3
Cast iron gate va]ves hand oPerated to
RS 3464 (type al wlth e-tension so{ndles.
J813. 1 400 run nomlnal bore with T key. nr 4
J813 .2 400 mm nominal bore wlth hand wheel-. 2
J813 . 3 500 mm nomlnal- bore wlth hand wheel. nr 3
Cast i ron val ves as Ho] dwater Tndustr'l es
catalogrre numbers stated or slml Iar
agproved.
J83 5 Double hinged flap valves nominal bore
1100 mm nr 890. nr 2
J884.1 Penstocks nomlnal bore 700 mm nr 731 with
handwheel headstock and foot bracketi
lnvert to handwheel dlstance 2050 mm. nr 6
J884.2 Penstocks nominal bore 700 mm nr 740 with
T key headstock and foot bracket; invert
to T key distance 3100 mm. nr 9
,J894 Sludge draw off vaLves nomlnal bore
?00 mm nr 780. nr 3
PAGE TO
49
CESMM3 EXAMPLES
CHAT MOSS PIPELINES
Number Item descrlptlon Unlt Quantlty Rate Amount
Ê p
pTÞRÍ¡IORK - MÀNHOT,ES ÀND ÞTpRf/rlORK
AN.CLIJ.ITÀBI¡.L.
Manholes
Kl1 1 Brlck depth not exceedlng 1.5 m; excavated
by hand; type Al with medium duty cast lron
cover to BS 497 reference MB1-55. nr 1
K112.1 Brick depth I.5 - 2 m; type A1 with heavy
duty triangul-ar cast iron cover to BS 497
reference MA-T, nr 'l
KTL2.2 Brlck depth L5 - 2 m; type A2 with medlum
duty cast iron cqver to BS 497 reference
MB2-55. nr 4
KL22.L Brick wlth backdrop depth I .5 - 2 mi type
410 with cast lron cover to BS 497
reference MC2-60/45. nr 5
Kr22.2 Brlck wlth backdrop depth 1.5 - 2 m;
type 420 with cast iron cover to BS 497
reference MCl-60,/60. nr 3
Kt 52 Precast concrete depth I.5 - 2 rn; type Cl
wlth triangul.ar cast iron cover to BS 49?
reference MA-T. RT 33
K21 1 Catch plts brlck depth not exceedlng 1.5 m;
type Kl with l-ight duty cast iron cover to
BS 497 reference C6-24/24. nr 6
K360 GuLLles precast concrete trapped; wlth
medium duty straight bar gulley grating to
BS 497 reference El2-L2. nr 15
K4 10 Fllllng of French and rubble drains with
graded material; type C3 granular materiaL m
3
310
K433 Trenches for unpiped rubble dralnç
cross-secti.onal aiea 0.5 - 0.75 m2. m 54
K434 Trenchesfor unplped rubbl-e dralns
cross-sectlonal aiea 0.75 - 1 m2. m 89
K4 53 Rectangular sectlon ditches cross-sectional
area 0.5 - 0.15 m¿; tined wlth L000 g
auge melded flbre mat. m 2B
PAGE
50
EXAMPLE BILL OF OUANTITIES PAGES
CHAT MOSS PIPELINES
Number Item descriptlon Unit Quantlty Rate Amount
Ê p
ANCTLT.ARIF]S .
K542 Unglazed vltrified clay 4 way 100 mm
nominal bore cable duct loose Jointed in
trenches depth not exceeding 1.5 m
beneath roads. m 1,4
K543 Unglazed vitrified cJ-ay 4 way 100 mm
nominal bore cabl-e duct Ìoose jointed in
trenches depth 1.5 - 2 m beneath roads. m 25
K553 Sectional corrugated metal culverts as
Specification clause K5613 nominal
internaÌ diameter 700 mm in trenches depth
I.5 - 2 m in outfal-l-. m 63
C ros s in gls,
K623.r River width 3 - 10 m pj-pe bore
900 - 1800 mm. nr 2
K623.2 Canal- width 3 - 10 m,' PiPe bore
300 - 900 mm. NT 4
K64 I Hedge; pipe bore not exceedlng 300 mm. nr 30
K61 L sewer or drain; pipe bore not exceedíng
300 mm. nr 15
K612 Sewer or drain; pipe bore 300 - 900 mm. nr 1
K682.I Gas main; pipe bore 300 - 900 mm. nr 2
K682.2 Existing sludge draw off pipe line: pipe
bore 300 - 900 mm. nr 2
K683 Underground high voltage elect,ric cable:
pipe bore 900 - 1800 mm. nr 1
Re i nst atement .
K71 I Breaking up and temporary reinstatement
of roads flexible road constructlon
maximum depth 75 mm with 250 mm sub-base;
pipe bore not exceeding 300 mm. m 387
K1L2.T BreakÍng up and temporary reinstatement
of roads reinforced concrete slab depth
200 mm with 250 rnm type L 3ub-base; plpe
bore 300 - 900 mm. m 284
PAGE
51
CESMM3 EXAMPLES
CHAT MOSS PIPELINES
Number Item descrlptlon Unlt Ouantlty Rate Amount
Ê p
PTPEWORK - MÀNHOT,ES ANN PTPEWORK
ANç.IL¡ÀBJ¡.I.
K712.2 Breaking up and temporary reinstatement
of foads flexi-ble road construction
maximum depth ?5 mm with 250 mm type 1
sub-base; pipe bore 300 - 900 mm. m 783
K14]- Breaking up temporary and permanent
reinstatement of footpaths precast
concrete paving flags maxlmum depth 75 mm
with 50 mm sand bed; plpe bore not
exceedlng 300 mm. m 54
K760 Strip topsoil from easement and reinstate
in cultivated land; mlnimum wldth 20 m. m 3't26
ôl. har ni nourarì¡ ¡n¡l I I ¡vi ac
KSrCr ReLnstatement of field ciraLns. m 241
KB2O Marker posts; 100 x 100 x 1500 mm hardvùood
set in concrete base as drawing 1,37/15
detail- C. nr 41
K83 0 Timber supports Ìeft ln excavatÍons. m
2
450
K852 Connectlon of pipes to exlstlng manholes;
nominal bore 200 - 300 mm; fouf water sewer
lncÌuding breaking into manhole,
reforming benching and dealing with flows
in accordance wlth detail-7 drawing c3/21. nr I
PAGE
52
EXAMPLE BILL OF OUANTITIES PAGES
CHAT MOSS PIPELINES
Number Item descrlptlon Unit Quantlty Rate Amount
E p
PTpFÍTÍORK - SLpÞORTS ÀNn pROTFCTTON
ÀNCTf,T,ARTFS TO T,ÀYTNG ÀNN RXCAVATION.
Extras to excavation a¡d backfi lllng
in nlna Ìiôñ^hôe
3
Ll11. Excavation of rock. m 460
LLI2 Excavation of mass concrete. 65
L113 Excavatlon or rei.nforced concrete. B5
Ll15 Backfilling above the Flnal Surface wlth 3
concrete; mix ST 1. m 2
L1- 16 Backfllling above the Flnal- Surface with
imported naturaÌ materlaf other than rock 3
or topsoil. m 310
Ll17 Excavation of natural material brelow the
F1nal Surface and backfllllng wlth
concrete: mlx ST 1. 260
L118. L Excavatlon of natural materlal below the
Final Surface and backfilling wlth type C2 3
granular materiaL. nì 274
L11B " 2 Hand excavatlon of natural material bel-ow
the Final Surface and backfllling with 3
type C3 granular material. m 230
E-tras to e-cevation ¡nd backfi l li no
LL2T In manhol-es and other chambers excavation
of rock. 27
LT22 In manholes and other chambers: excavatlon
of mass concrete. 4
3
L14 1 In thrust borlng: excavatlon of rock. m L27
Speclal p'l pe I ayl ng methods.
L223 Thrust boring pipe nominal bore
300 - 600 mm; manholes 18 to 19. m 98
PAGE
53
CESMM3 EXAMPLES
CHAT MOSS PIPELINES
Number Item descrlptlon Unlt Ouantlty Rate Amount
Ê p
ÞTPE!ìIORK - SUÞpORTS ANfì pROTF.CTTON
ÀNCIÍ,I,ARTFS TO T,AYTNG ANIì RXCAVATTON
Reds depth 1 50 mm
],33 1 Imported granular materlal- type C2
pipe nominal bore not exceeding 200 mm. m 27
L332 Imported granular material type C2 plpe
nominal- bore 200 - 300 mm. m 2483
13 52 Relnforced concrete mix ST 3 reinforced
as drawlng I3'7/I9 detall B pipe nomlnal_
bore 200 - 300 mm. m L25
L353
Reinforced concrete mlx ST 3 relnforced
as drawing I3'7/19 detalt À pipe nominaL
bore 300 - 600 mm. m 90
llarrnches.
L4;l I Imported granuJ_ar materlal_ type C2 ptpe
nomlnal- bore not exceeding 200 mm; beã
depth 200 mm. m 50
L432 Imported granular materlal type C2 plpe
nomlnal-bore 200 - 300 mm; bed depth
200 mm. m 250
Reds and surrounds.
L531. 1 Imported granular materlal type C2 plpe
nominal bore not exceeding 200 mm; bed
depth 200 mm. m 402
Surrounds
L531.2 Imported granular materiaL type C2 to two
pipes, maximum dj_stance between inside
face of outer wal_ls of pipes 600 mm; bed
depth 200 mm. m 41
L60 1 lagging pì.pe nominal bore not
Ialrapping and
exceedlng 200 mn with lrlrapþo. m 20't
PAGE TOT
54
EXAMPLE BILL OF OUANTITIES PAGES
CHAT MOSS PIPELINES
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
PTPFI!ìIORK - StlppORTS ANf'ì ÞROTFICTTON
ÀNCTT,T,ARIRS TO I,AYTNG ANI'ì FIXCÀVÀTTON
Stools and thrust blocks
L72I VoJ.ume 0.1 - 0.2 m3 concrete grade c21
plpe nomlnaL bore not exceedlng 200 mm. nr 4
L732 Volume O.2 - 0.5 m3 concrete grade G21
pipe nominal bore 200 - 300 mm wiÈh strap
as drawing 3/27 detatL 5. nr 2
L822 Isol-ated pipe support; height 1 - 1.5 m
plpe nomlnal bore 200 - 300 mm; 1200 mn
long hanger, 6 run galvanized mll-d steel as
drawfng 3/27 detaLL 3. nr 3
PÀGE
55
CESMM3 EXAMPLES
Number Item descrlptlon Unit Quanllty Hate Amount
I p
STRUCTURAL MFTAT,WORK.
a^ñirôir^r rtr âv.ññ a+^^l
^--¡^ ¡ ?r
^.ñt
F'abricat i on of members for frames
straì oht on pl ân.
M31 1 CoÌumns. t r.4
M32I Beams. t 0.9
M351 Roof trusses comprislng single
70 x ?0 x B angle rafters and 50 x 50 x 6
InternaL and bottom ties. t 0.9
M353 Bu1lt-up side girders cambered comprlslng
two single 150 x 90 x 12 angles top boom,
two single 150 x 75 x 12 angles bottom
h
boom with verticals ?0 x 70 x 8 angJ-es,
diagonals 70 x 70 x 8, B0 x 80 x B and
90 x 90 x 10 angles. t 2.6
M3 51 Bracings, purlins and claddíng rails. t L.1
M37 0 GriJ-J.ages. t 0.4
M380 Anchorages and holdlng bolt assemblies
còmprising 4 nr 450 x 24 bolls with plates
150 x 150 x 10. nr 4
Rrection of conveyor gantry.
M620 Frame members, t 7.9
M632 Site bol-ts black diameter 16 - 20 mm nr 150
M662 HSFG load indlcating bol-ts diameter
16 - 20 mm wÌth washers. nr 84
Convevor gantrv e-amoÌe C. steel grade 434
Off Site surface treatment.
M810 Blast cleanlng to BS 4232 second quality. m
2
24t
M870 Palnting one coat zinc epoxy prlmer. m 241
PAGE TO
56
Ir
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unit Quantily Rate Amount
I p
MÏSCET,LÀNEOUS METÀT,VIORK
N1l0.l- Stalrways and landlngs; stalrcase 53
drawing L36/2'l . t 3.'t
N110.2 Stairways and landings; staircase 54
drawing 136/28. t 4.5
N130.1 Galvanised mlld steeL l-adders; stringers
65 x 13 mm, 400 mm apart, rungs 20 mm
diameter at 300 rnm centres; stringers
extended and returned 1000 rnm to form
handrail. m 14
N130.2 Gal-vanised miLd steel Iadders; stringers
65 x 13 run, 400 mm apart, rungs 20 mm
dlameter at 300 run centres; stringers
extended and returned 1000 mm to form
handrail; wlth safety cage of 3 nr
65 x 13 mm verticals and 65 x 13 mm hoops
750 mm diameter at ?00 mm centres cage
commencing 2500 mm above commencing leveI m 24
N161.1 Miscel-laneous framing; galvanised m1Id
steeJ. angle section 64 x 64 x 9 mm. m 24't
N161.2 Mlscel-Laneousframing; galvanised miJ-d
steel angle sectlon 38 x 38 x 6 mm. m 53
N1 70 Plate floorlng; galvanlsed mlld steel-
cheguer pJ-at.ing 10 mm thick as detaÍled o¡i
drawing 136/42. m
2
86
N180 Open grid floorlng; galvanised mild steel-
to BS 4592 as detail-ed on drawing I37/49. m
2
47
N23 0 Duct covers; galvanised mild steel
10 mm thick, width 300 m¡n as detailed on
2
drawing L31 /50, m 27
N28 6 Covered tanks vol-ume 100 - 300 m3;
galvanised mil-d steel- to BS417 part I
reference T40. nr 3
N999.1 Gal-vanisedmild steel adjustabJ-e V-notch
weir plate to precise l-evels as detalled
on drawlng 136/7 detail A. m 137
N999.2 Cast iron light duty lnspection cover to
BS 497 reference C6 - 24/24. nr 2
N999.3 Supp1y cast iron step irons to BS 1247
type a2. nr t2
N999.4 SuppJ.y 2200x 2200 run galvanised mild
steel forebay screen as detalled on
drawing 1,36/98. t L.4
PAGE TO
57
CESMM3 EXAMPLES
DOCK 3
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
TTMRER
Hardwood comognents cross-sectional ¡re
0.0ì - 0.02 rÉ: wrouoht finlsh,
or22 150 x'?5 mm Greenheart length 1.5 - 3 m. m 184
or23 150 x 100 mm Greenheart length 3 - 5 m;
pier decking runners. m 204
Hardwood components cross-sectìonal area
0.04 - 0.1 rrÉ: wrought flnísh.
014 3 300 x 300 mm Greenheart J-ength 3 - 5 m;
pler braces between pl1es. m 163
Hardwood co$ponents cross-section¡l area
0.1 - 0.2 nÉ: wrought flnish.
tr
oL52 350 x 350 mm Greenheart length 1.5 - 3 m m 28'l
o15 3 400 x 400 mm Greenheart length 3 - 5 m;
pier decking bearers. m 364
Softwood components çross-sectional area
not evceedino 0.01 rrÉ: wrouoht f i ni sh.
02L1 75 x 75 mm DougJ-as flr tanalized length
not exceeding 1.5 m. 196
o2r2 100 x I00 mm DougJ-as fir tanalized length
1.5 - 3m. m 47
o213 100 x 50 mm Douglas flr tanaLlzed with
rounded edges length 3 - 5 m; hand rall 280
Softwood components cross-sect{ona'ì area
0.04 - 0.1 nÉ: wrought fìnlsh.
0242 150 x 300 mm DougJ-as fir length 1.5 - 3 m m 48
o243 225 x 3OO mm DougJ.as fir length 3 - 5 m,'
pier rubbing píece. m 440
PAGE TOT
58
EXAMPLE BILL OF OUANTITIES PAGES
DOCK 3
Number Item descrlptlon Unlt Ouantlty Rate Amount
E p
2
0330. 1 150 x 70 run Greenheart m 786
2
0330.2 250x70mGreenheart. m 260
Flttlngs ând fâstenlngs.
Gal vanised mi I d stee l .
0510 Straps glrth: 457 mm wldth 50 mm thLckness
5 mm as drawlng D3/2'l . nr 10
o520 Splkes: Iength 75 mm. nr 50
0540.1 Bolts: J.ength 75 mm, dlalqeter 5 mm. nr 50
a540.2 Bolts; stalnLess steel length 100 mm
dlameter 6 mm. nr 40
o550 Plates; stalnless steel 100 x 100 mm
thLckness 6 mm. nr 10
PAGE
59
I
CESMM3 EXAMPLES
PUMPING STATION
Number Item descrlptlon Unlt Cf,¡antlty Rate Amount
E p
Pl l ing to Prrmplng St¡tlon.
aannan¡inn arrrf:¡o ?? ôô r n ¡l
Rored cast in pìace plles concrete gr¡de
C25' as Sgeclflcatlon clause 713.3.
l''llameter 900 mm.
P 151 Number of plles. nr 97
PL52 Concreted length. m 1 195
P 153 Depth bored maximum depth 18m. m 1305
filameter 1200 mm raked at incllnatlon
ratlo l:6.
P 161 Number of piles. nr 42
i L9¿ Concreted Ìength. m 932
P 163 Depth bored maxlmum depth 35 m. m 992
PAGE TO
60
EXAMPLE BILL OF OUANTITIES PAGES
BRIDGE
Number Item descrlptlon Unlt Quantlty Rate Amount
I p
PLU¡sLo-,.Bddce.
aannan¡aâ err¡f:¡a +n L^ ^¡ -^ 1
^-¡
Soecl ficatlon clause ?13.4 relnforcement
300 mm
P331. L Number of piles length 8.5 m; mild steel
drivlng heads and shoes. nr 10
P33 1 .2 Number of plles length L2.5 ßt, mlld steel
drivlng heads and shoes. nr t7
P332 Depth drlven. 284
Þreformed pl ìes concrete grade C25 as
Speci flcatlon clause 713-4 relnforcement
as detall 5 on drawlng |3?/65 nomlnal
r.lrcrrlar rllameter 450 mm.
P351. 1 Number of plles length 12.5 m. nr L2B
P35 1 .2
P352
Number of plles length I7.2m.
Depth driven.
nr
m
40
2720
tr
PAGE
61
CESMM3 EXAMPLES
P IER
Number Item descrlptlon Unlt Ouant¡ty Rate Amount
I P
eilf¡È-ro--e&.r.
:
0-15 - 0.25 ÍÉ: 400 Y 4OO mm Greenheert'
Commencino Surface to be Origlnal Surface
of bed of Rlver Corve,
P 651 Number of plJ-es length 7.5 m; galvanlsed
mild steeL driving head and shoe as detail
5 drawing L40/'l . 104
P 652 Depth drj.ven. 630
PAGE
62
EXAMPLE BILL OF OUANTITIES PAGES
STORAGE TANK
'ltcm.deccrlptlon Unlt Quantlty Rato Amount
Numbcr
I p
PTT.TNG 'NO SÎORAGE TTÀNK.
Tnterlockìngr grrade 43À steeì plles
Conrmenclng Surface 300 mm below Orlglnal
Srrrface.
P831.1 Length of corner plles. m 44
P83L.2
- Iength of taper plles. m 21
PB32 Driven area. a2 684'l
P 833 Area of plles of length: not exceedlng
14 mi treated with two coats bltumen paint m 3764
P 834 Area of plles of length: 14 - 24 m;
treated wlth two coats bitumen'palnt *2 4iê1
PAGE
63
CESMM3 EXAMPLES
PUMPING STATION
Number Item descrlption Unlt Ouant¡ty Rate Amount
E p
PIIJNGINSLIJ¡ARITS
C¡s.t In pl ¡ce concrete oi ì es.
Qr25 Backfilllng empty bore with selected
excavated materiaÌ diameter 900 mm. m 20
Q135 Permanent caslngs each length not
exceedlng 13 m, dJ.ameter 900 mm diameter
plle, m 40
Qlss Enlarged basesi 2500 mm diameter to 900 mm
diameter pile. nr 87
Q15 6 Enlarged bases; 3000 mm dlameter to 1200 mm
diameter plle. nr 42
Q1B 5 Preparlng heads 900 mm diameter. nr 87
QLB 6 Preparing heads; 1200 mm diameter. nr 42
Mlld steel reínforcement to RS 4449.
Q2LL Stralght bars, nomlnal slze not exceedlng
25 mm. t 46.3
Q2I2 Straight bars, nominal slze: exceedlng
25 mm. t 27.3
Q700 Obstructlons h 150
PAGE
64
EXAMPLE BILL OF OUANTITIES PAGES
P IER
Number Item descrlptlon Unlt Quantlty Rate Amount
Ê p
P Tf .ING ANCTI,I,ARTES
Timbcr oì lcs crass-sa¡tian¡l ¡re¡<
0.1's - ô-2s n3.
Q4 15 Pre-boring. m 200
Q44s Number of pile extenslons. nr .50
Q455 Length of pile extensions each Length not
exceedlng 3 m. m 75
Q47s Cutting off surplus lengths. m 25
Q700 0bstructions. h 10
Q81 1 Pile tests, maintained loading wlth
various reactic.¡ns test Load: 75 t; to
workíng pile. nr 5
PAGE TO
65
CESMM3 EXAMPLES
TANKS
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
pTT,TNG ANCTT,f.ÀRrES.
Interlocking stçel plJ.es section
moduLus 1150 cmr/m.
Q64 3 Ur.U.t of pile extensions. nr 150
0653 Length of pile extensions each Ienqth
not exceeding 3m. m 300
Q673 Cuttlng off horizontal surplus lengths,
average depth 1..5m. 220
Q70 0 Obstructions. h 20
PAGE
66
EXAMPLE BILL OF OUANTITIES PAGES
NEIITON TO DINCHOPE ROAD
Item descrlptlon Unlt Ouantlty Rate Amount
Number Ê p
ROADS ÀND PÀVTNGS.
Sub-beses. f I evihl e ro¡d l"'¡ses and
surfaclng.
R118 Granular material DTp SpecÍfled type 1
depth 475 mm. 3760
R2L6 lfet-mix macadarn DTp Specifled cl-ause 808
depth 210 mm. 3750
R232 Dense bitumen macadam DTp Speclfied cl-ause
903 depth 60 mm. 37 60
R322 Rol-l-ed asphalt DTp Specified clause 907
depth 40 mm. 3?60
R341 Surface dressing depth 25 mm; nomj-nal 20 mm
coated chlppings. 3?60
R61 1 Straight or curved to radlus exceedlng
12 m. 971
R61 2 Curved to radlus not exceeding 12 m. 48
R61 3 Quadrants 27
R64 1 Precast concrete channels to BS 7263:
Part I figure 1 (h) straight or curved to
radius exceeding 12 m; 400 x 150 mm bed. 9r'7
R642 Precast concrete channel-s to BS 7263:
Part 1: figure I (h) curved to radius not
exceedlng 12 m, 400 x 1.50 mm bed. 48
R64 3 Precast concrete channels to BS 7263:
Part L: figure 1(h) quadrant, 400 x 150 nm
bed. 27
T,ight duty Davements.
R714 Granular base depth 150 mm; DTp Specifled
type 1. r426
R127 Hardcore base depth 300 mm. 387
R77 4 In situ concrete grade C15 depth 150 mm. 387
R78 3 Precast concrete fJ-ags to BS'1263: Part 1:
type D; thickness 63 mm. t426
R90 0 Joint new concrete road to existing
concrete road. 2't
PAGE
67
É
CESMM3 EXAMPLES
SERVICE ROADS
Number Item descrlptlon UnIt Quantlty Rate Amount
I p
BOADSIND-PÀ]¿IXGS.
Sub-bases, flexibLe road bases and
surfacing.
Rt24 Granular materlal DTp Speclfled type 2
2
depth 150 mm. m 103 9
2
R17 0 GeotextlLes; Georam, grade G2. m 103 9
R18 0 Additional depth of hardcore. a3 380
Côneretê pevements.
R414.1 Carriageway slabs of DTp Specifled pavlng
qual-ity concrete depth 150 mm. m
2
103 9
R4r4.2 Carriageway sl-absof DTp Speclfied pavlng
quality concrete depth 150 mm; lncllned at 2
an angle exceeding 10. m t1 64
R443 Steel fabric reinforcement to BS 4483 2
nomlnal mass 3 - 4 kq/n2; type 4252. m 103 9
R4BO Waterproof membrane below concrete
pavements; 500 grade J.mpermeable plastlc
2
sheeting. m 103 9
Jolnts in concrete oavernents.
R52 4 Expansion joints depth 100 - 150 mmi as
detail C drawlng I31/5I at 5 m centres. m 32L
R53 4 Contractlon jolnts depth 100 - 150 mm; as
detall- D drawing 1,3'l/5I aE 2,5 m centres. m 47
Kerbs, channels and edglngs,
R65 1 Precast concrete edglngs to BS 7263:
Part 1: figure 1 (m) straight or curved to
radius exceeding 12 m¡ 200 x 200 mm
concrete ST1 bed and haunch. m r27
R652 Precast concrete edglngs to BS 7263:
Part 1: flgure 1 (m) curved to radius not
exceedlng L2 n; 200 x 200 mm concrete
STL bed and haunch. m 480
PAGE
68
EXAMPLE BILL OF OUANTITIES PAGES
SERVICE ROADS
Number Item descrlptlon Unlt Quantlty Rate Amount
E P
ROAI'IS ANN PÀVTNGS.
T,lgit d¡tv o¡vements.
R713 Granular base DTp Speclfled type 2
depth 100 mm. m
2
840
R714 Granular base DTp Specifiäd type 2 depth
150 mm; lnclined at an angJ-e exceedlng
L0 to the horlzontaÌ. m
2
31
R782. 1 Precast concrete flags to BS 7263: Part I
type D depth 50 mm. m
2
330
R182 "2 Precast concrete flags to BS 7263: Part 1
type D depth 50 mn; inclined at an angle
exceeding 10 to the horlzontal-. m
2
390
PAGE
69
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
BÀUJIAACK.
s 110 Track foundatlon. bottom ballast, 3
crushed granite. m 636
s120 Track foundatlon, waterproof membranet 2
visQueen 1000 gauge. m r250
Tâklng up trâck
lfelded trâck on cóncrete cIeepers. ftìllv
rf a'.t'êñ Àrnc n w â
s21 1 Bul-l head rail, plaln track. 2000
s2L4 BulL head rail, turnouts. nr 4
s25 0 Conductor rails. m 4 000
s28 1 Sundr1es, buffer stops, approximate weight
2.5 tonnes <¡f sueel- raii and Llmber
sleeper construction. nr 4
s283 Sundrles, wheelstops. 2
f,lftlno, o¡ckino and slewlng.
s310 BulI head rall track, Iength 20 m, maxlmum
distance of sl-ew 200 mm, maximum lift
100 m. NI 1
Supplyi ng.
s425 FLat bottom rail, reference 113A, mass
56 kg,/m. 38
s4?1 Sleepers, softwood tlmberl
2600 x 250 x 130 mm. nr s04
s472 Sleepers, concrete 26O0 x 250 x 150 mm
type C2. nr 2'l
s481 Fittings, chairs, type 4. nr 1008
s482 Fittings, base plates, type 3. nr 1008
PAGE
70
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unlt Quantlty Rate Amount
Ê p
RATT, TRACK.
Suoplyl ng.
s4 83 Pandrol rall fastenlngs, type 7. nr 94
s4 84 Plain ftsh plates, type 9. nr L2'l
s5 10 Turnouts, type T4, drawing 27. nr 4
s520 Dlamond crossings, type DCl drawlng 27. nr 2
s5B 1 Sundrles, buffer stops, type 82 approximate
welght 2.5 tonnes. nr 4
s58 5 Sundrles, swltch heaters, type SH2. nr 6
Lavl ng fI at bottom ral l s.
s621.1 Plaln track; rail reference J.134, mass
56 kg/m, flsh plated Jolnls on tlmber
sleepers. m 3200
s62L,2 Plaln track; ral1 reference 1134r mass
56 kg,/m, welded Jolnts, on concrete
sleepers. m 2000
s623 Form curve ln plaln track, radlus
exceedlng 300 m, welded Jolnts on concrete
sleepers. 500
s624 Turnouts type T4, drawlng 27, Iength
26.2 m, flsh plated joints on timer
sleepers. nr 4
s625 Diamond crosslngs, type DCl. drawLng 21'
Iength 27.4 n, flsh plated Jolnts on tlmer
sleepers. nr 2
s627 Íùelded Jolnts by Qulck Thermlt process. nr 10
s68 1 Sundrles buffer sÈops approxlmate
weight 2.5 ,tonnes. nr 4
s685 Sundrles swltch heaterç. nr 6
PAGE
71
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Ouantlty Rate Amount
E p
FORTIFÀY TT'NNET, ANN OVFÌRFT,OW SI¡ÀF'T
Tunnel e-cavatlon d'l ameter 2.5 m.
3
T112.1 In rock; stralght. m 2L80
,TLL2.2 In rock; curved, materlal to be used
as filllng. a3 520
TL32 Shaft excavatlon diameEex 2.8 m ln rock; 3
stralght. m 280
T17 0 Excavated surfaces ln rock; volds fllled
with cement grout as Speciflcation cLause
2
r3't /1t7 . m 4352
T232.I In situ reinforced cast concrete primary
stralght tunnel linlng internal diameter
2.0 m; concrete as Specj.fj.catlon 2
clause 137 /F3. m 820
1232.2 In sltu relnforced concrete primary
curved tunnel llnlng lnternal dlameter
2.0 m; concrete as Specificatl-on clause
L3't /83. a3 175
T252.1 In sltu straight linlng formwork flnlsh
grade T2 lnternal dlameter 2.0 m. m
2
3 566
"1252.2 In situ curved llnfng formwork flnlsh
grade T2 lnternal dlameter 2.0 m. m
2
160
PAGE TOT
72
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descrlptlon Unit Gluantlty Rate Amount
I p
DÍVFRSTON TTINNEÍ,.
útlork to be e'ecuted under compressed ai r
ât garlge Presstrre not evceeding one bar.
"tL28,L Excavation stralght tunnel- dlameter
10.3 m In Group 5 materlaL. m
3
4 1000
rL28.2 Excavation straJ.ght tunnel diameter
10.3 m in Group 6 materlal. m
3
8800
T180.1 Excavated surface Group 5 materials;
volds fil1ed with cement grout as
Specificatlon Clause L3'l /T1,'l . m
2
15800
TL80,2 Excavated surface in Group 6 material;
voids fil-Ied with cement grout as
Specification C1ause L37 /1I7. m
2
3400
T53 B Cast iron bol-ted segmentaÌ tunnel lining
rlngs lnternal- diameter 9.5 m; nominal
wldth 450 mm comprlsing 16 segrments
maxlmum plece welght 110 kq l-36 bol_ts
and grummets and 2'12 washers. nr 133 0
Ts? 1 Parall-el circumferentlal packlng for
preformed segmental tunnel linings
lnternal- dlameter 9.5 m;
bltumen impregnated fibreboard
thlckness I mm. nr 1,329
T57 4 Leaf fibre cauJ.king for preformed
segmentaL tunnel- Iinings internaL dlameter
9.5 m. m 51500
PAGE
73
L-.
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
FOREFÀY TUNNET, ANn OVERFT,OI/ù SIIAFT
rectanoular 3.2 - 2-4 m.
1332 Cast concrete size 2.'15 x 1.95 m; 3
concrete as Speclflcatlon clause 137,/F3. m 130
T352 Formwork finlsh Grade T1 size 2.75 x
2
1.95 m. m 615
Srrpport and stal'i I i zatlon.
TB11 Rock bolts lmpact expanding mechanical
55 diameter with 30 mm square shank
mm
maximum length 5 m. m 108
Pïessure grouting.
TB3 1 Sets of drllllng and grouting plant. nr
1
T832 Face packers. nr 180
TB3 4 Drllllng and flushlng dlameter 50 mm
length5-10m. m 1 080
TB3 5 Re-drilllng and fLushing holes length
5-10m. 540
T83 6 InJection of cement grout as Speciflcatlon
clause 13?/T801. t B5
T84 0 Forward probing J-ength 10 - 15 m. m 480
PAGE
74
EXAMPLE BILL OF OUANTITIES PAGES
Number Item descriptlon Unit Quant¡ty Rate Amount
Ê p
RRTCR!ìIORK. BT,OCKWORK ANn MASONRY.
Cornmon briekwork to RS 3921: stretcher
bond, flush pointed mortar tvpe M2.
u111 fOZ'.5 mm nominal thickness vertlcal
stralght wal-1s; cavlty constructlon. *2 287
u1 60 Columns and plers, cross-sectional
dimensions 600 x 600 mm. m 43
Ancì ì larì es
uI82.l Damp proof courses; width 100 mm to
BS 743 type D. m 150
uL82.2 Damp proof courses; width 225 mm to
BS 743 type D. m l1
ut 85 Concrete lnfill grade 1; thlckness 50 mm. m
2
31
U1B6 FÍxing and ties; galvanised mild steel-
in accordance with Specification
2
cl-ause 5/27. m 304
U1B7 Bullt-in pipes and ducts cro ss -s ect i on a l-
area not exceeding 0.05 m.
2
NI 69
u188 Built-in pipes and ducts cross-sectlonal-
area O .10 mz. nr 6
Facing brickwork.
Plowden Red facings as Specific¡tion
clause 5/29.
U2IL 102.5 mm nomlnal thi-ckness vertical-
straight wall-; stretcher bond flush
pointed, mortar type M3 cavity
construct ion . m 321
Surface featrrres.
v21I.r Brick on edge coplng. m 143
u217 .2 Special sill as detail D drawing I31/91. m 31
PAGE TOT
75
CESMM3 EXAMPLES
Number Item descrlption Unlt Quantlty Rate Amount
E P
BRTCKVÙORK. RT,OCKVIORK ÀND MASONRY.
Rrickwork anciÌ l ari es.
u282 Damp proof coursesi width 100 mm to
BS '?43 type D. m 187
U2B7 Bullt-ln pipes and ducts cross-sectlonal
area not exceeding 0.05 m 2 nr 69
U2B 8 Built-Ín pipes and ducts cross-sectional
area 0.10 m'. nr 6
Rnoineering brìckwork class R to ÊS 3921,
stretcher bond¡ flush pointed mortar
type M4.
u33 3 450 mm nominal- thlckness battered stralght
wall. m
2
8?
u33 4 450 mm nominal thickness battered curved
2
walI. m 184
u37 1 Bullnosed copings m 41
u37 5 BuJ.Inosed corbels. m 83
U3B3 Movement Jolnt; 25 mm bitumen impregnated
fibreboard, mean wldth 450 mm wlth
plastljoint seal-er both sides. m 27
u38 4 Bond to existlng work. m
2
L4
u4t 1.1 VertlcaL l00 mm nominal thlckness
stralght wall. m
2
203
usrt.2 Vertical 140 mm nominal thickness
straight wall. m
2
t2'l
u482.r Damp proof courses; width 100 mm to
BS 743 type D. m 83
o482.2 Damp proof courses; width 140 mm to
BS 743 type D. m 46
PAGE
76
EXAMPLE BILL OF OUANTITIES PAGES
Number Item desctlpt¡on Unlt Quantlty Rate Amount
Ê p
ÊRTCKI¡IORK. FÌ,OCKVIORK AND MASONRY.
Ilense concrete hìockwork. solld block to
BS 6073, stretcher bond. flush pointed
ñ^7È:7 f rrñô M1
u5l- 1 Vertlcal 140 mm nominal thickness stralght
waLl. 83
^2
u582 Damp proof coursesi wldth 140 mm to BS 743
type D. m 27
u587 Bullt-in pipes and ducts cross-sectlonal
area not exceedlng 0.05 m.
2
nr 4L
Àshlår mesonrv portìând stone rubbed
flnlsh Speciflcation clause 5/40 mortar
type M2.
u73 5 300 mm nonlnal thlckness vertLcal faclng
to concrete flush pointed. m
2
4387
u77r Surface features; rounded coplngs
1200 x 600 mm as drawing L37/9L. m r236
u78 6 Àncillarles flxlngs and tles; Alleyslots
at 1500 mm centres. m 4 38?
u787 AnciLlarles built-ln plpes and ducts
cross-sectl-onal area 0.025 - 0.25 m'. nr 45
u799 BoLlards diameter 600 mm height 900 mm as
drawÍng L37 /93. nr 24
PAGE
77
L-.
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
,PAINTING
vl- 13 Zinc rich prlmer paint on metaL surfaces
othêr than mctal sectlons and plpework
lnclined at an angJ-e exceeding 60' to' the
horizontal; in one coat. 41
v116 Zin'c rlch prJ-mer paint on metal surfaces
other than metaL sectlons and pipework
width not exceeding 300 mlir; in one coat. m 91
Vl1B Zinc rich prlmer paint on metaf surfaces
other than metal- sectlons and plpework
lsolated groups of surfaces; 300 x 200 mm
inspection covers and frames in one coat. nr 1,4
OiI peint in three coâts
v313 On metal surfaces other than metal
sections and pipework; incllned at an
angle exceedlng 60' to the horizontal. 47
v31 6 On metal surfaces other than metal
sections and pipework of width not
exceeding 300 mm. m 91
V31B On metal surfaces other than metal
sectlons and plpework isofated groups of
surfaces; 300 x 200 mm inspectlon covers
and frames, I4
v326 Timber surfaces of width not exceedJ.ng
300 mm. 14
Emulslon palnt ln three coats.
v533 Smooth concrete surfaces incLined at an
angle exceeding 60' to the horizontal. m 481
v53 4 Smooth concrete soffit and lower
surfaces inclined at an angJ-e not, 2
exceedlng 60' to the horlzontal. m 326
v5 63 Brlckwork and blockwork surfaces
Inclined at an angle exceedlng 60' to the
horizontal. 3 867
v566 Brlckwork and blockwork surfaces of
width not exceeding 300 mm. m 187
v633 Cement palnt on smooth concrete surfaces
lnclined at an angle exceeding 60' Èo the 2
horj.zontal; in one coat. m 2'l
v63 6 Cement paint on smooth concrete surfaces
of width not exceeding 300 mm; in
one coat. L4
PAGE
78
EXAMPLE BILL OF OUANTITIES PAGES
GENERATOR HOUSE
Number Item descrlptlon Unlt Quantlty Rate Amount
I p
SAI¡.BPBAO&ING
w131 Damp prooflng, waterproof sheetlng to
upper surfaces incl-ined at an angle not
exceedlng 30 to the horizontal; polythene
to BS 3012 in one layer thickness 5 mm. m
2
320
W2LL Tanking, asphaJ.t to upper surfaces
lncl-lned at an angle not exceeding 30' to
the horizontal; mastic asphalt to BS 1097 2
in one coatlng thlckness 25 mm. m 410
!{213 Tanking, asphalt to surfaces lncllned at
an angJ-e exceedlng 60' to the horlzontal;
mastic asphalt to BS 1097 In one coaÈIng 2
thickness 25 mm. m 534
fü311 Rooflng asphalt upper surfaces lncLlned
at an angle not exceedlng 30' to the
horlzontal-i mastlc asphalt to BS 988 in
two coatings total thlckness 25 mm
lncludlng heavy gauge poJ-ythene Isolating
membrane non-stalning rooflng felt to
BS 74? type 1C expanded polystyrene
thickness 25 mm and concrete grade 10
screened average thickness 75 mm. m '126
vù44 1 Protective layer sand and cement screed
type A thickness 25 mm upper surfaces
lncllned at an angJ-e not exceeding 30' to
the horizontal. m
2
410
PAGE
79
CESMM3 EXAMPLES
PUMP HOUSE
Number Item descrlptlon Unlt Quantlty Rate Amount
Ê p
I/iIATRRPROOF'TNG
RoofÌng
Ít3? 1 Proflled alumlnlum sheet to BS 4868
type A L mm thick ln one layer upper
surfaced lncl-ined at an angle not exceedlng
30' to the horizontal. m
2
463
!lI373 Proflled aluminium sheet to Bs 4868
tt/pe A 1 run thlck in one layer surfaces
Inclined at an angl-e exceedl-ng 60' to the 2
horizontal. m t25
Íù371 Waterproof sheetlng upper surfaces
lncllned at an angle not exceedj-ng 30'
to the horlzontal; corrugated plastic
translucent sheet to BS 4154 1.5 mm thick. m
2
51
PAGE
80
EXAMPLE BILL OF OUANTITIES PAGES
Numbör Item descrlptlon Unit Quantlty Rate Amount
E p
MTSCET,Í,À\ROUS WORK
F enFes
x1 13 Timber post and rail fence helght 1.3 m,
to BS l'122 Part 7. 187
x133 Concrete post and wire plastic coated
chain lLnk fence to BS 1722 Part I height
1.4 m concrete grade 10 foundations
450 x 450 x 450 mm deep. 4?0
xl3 6 Concrete posÈ and wlre anti-lntruder
chaln link fence to BS L'122 Part 10 height
2.9 m¡ with cranked posts concrete grade
10 foundations 600 x 500 x ?50 mm deep. 305
xr.63.1 T1mber close boarded fence hetght 1.4 m;
wlth concrete posts to BS 1755 Part 5
concrete grade 10 foundations on surface
lncllned at an angle exceedlng 10' 13
xl91 Chestnut pale fence helght 900 mm,' with
timber posts to BS 1122 Part 4. 403
x1 93 MIld steel uncllmbable fence height
L.372 m; Lo BS L122 Part 9 concrete grade
10 foundatlons 450 x 450 x 450 mm deep. 108
x1 98 Mlld steel crash barrler helght 600 mm
concrete STI foundatlons
300 x 300 x 450 mm deep. t 871
PAGE
81
CESMM3 EXAMPLES
Number Item descrlptlon Unlt Ouañt¡ty Rate Amount
E p
U,ISCEIJTÀNEQIS-UA8Ã,.
GatFs and stlles
x215 Tlmber fleld gate, 2 leaves, overall
rrldth 3.353 m hetght 1.143 m; ro BS 3470. nr 14
x235 Metal fleld gate wldth 3.353 m helght
1.143 m; t,o BS 3470. nr 2
x295 Entrance gate wldth 3.5 m hetght 1.4 mt
galvanl-sed mlld steel angle sections
ftlled ln wlth plastlc coated chain llnk
fencing as detall D drawlng L3'l/75. nr 1
Iìralnage to strrrctures ¡hove cround
@.
x331.1 Gutters; 100 mm dLamet.er m 4'l
x33r.2 cutters; 150 run dLameter. m 36
x332.L Gutter bends 90'; 100 mm diameter. nr 10
x332.2 Gutter outletsi 150 mm dLameter. nr 8
x333. 1 Downplpes; 100 run dlameter. m 23
x333 .2 Downpipes; 150 mn diameter m 16
x334.1 Swan necks,' 100 mm dlameter. nr 4
x334.2 Shoes; 150 nun diameter. nr 3
PAGE
82
EXAMPLE BILL OF OUANTITIES PAGES
Numbcr Item descrlptlon Unlt Quantlty Rate Amount
I p
MI.SCEIJTÀNEa¡IS-HOBI,.
Rock f i'ì I ed gabions.
x410.1 Box gablon 1 x 1 x 2 mz 4 mm x 100 x 100 mm
galvanlsed wire mesh, excavated rock
grâde GB1. nr 21
x4L0.2 Box gabJ-on 1x 1 x 2 mi 4 mm x 100 x 100 mm
galvanlsed wire mesh excavated rock
grade GBl. nr 45
x420 Mattress gabion, thickness 150 mm,
4 mm x 100 x 100 mm galvanlsed wlre mesh,
2
excavated rock grade GB2. m 50
PAGE
83
CESMM3 EXAMPLES
NEI,ITON STREET
Number Unlt Rate Amount
E p
EIXT ST TNG PR T CK SRVÙTIR NOMT NÀL__gLUE--6.0.0_MN
ovo.In.
P¡ee¡¡'ia!,
Y1 10 Cleaning. m 5?
Removino Intrrrslons.
YT2I Lateral-; bore not exceeding 150 run;
clayware. nr L2
vL23 Dead water mal-ni bore not exceedJ-ng
150 mm; cast lron. nr 1
Y13 0 CCTV Survey. 57
Þìuoglno ìaterals wlth grout as
Sgeclfi catlon cl ause ?.21 .
Y13 1 Bore not exceedlng 300 mm. nr 2L
yL32 U shaped; lnternal cross sectlonal
dimensions 350 mn x 200 mm. nr 2
F{lllno laterals wlth grout as
Soecì fi catl on cì ause 7.21.
YI42 Internal cross section dimensions 3
450 mm x 350 mm U-shaped." m 1
@.
Yt 51 Area not exceeding 0.1 m2. nr 6
YI52 Area 0.1 - 0 ,25 m2 . nr 4
Y15 3 Area 0. 6 m2. nr 1
PAGE TO
84
EXAMPLE BILL OF OUANTITIES PAGES
NEI¡ITON STREET
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
EXTSTTNG RRTCK SEÍùER NOMTNAT, STZR 600 rnm
at¿o.rD.
Stalil I I -¡tion of e-lstlng sewers.
Y2LO Polntlng brlckwork with cement mortar. m
2
14
Y290 Pointing pipe Joints under pressure wÍth
epoxy mortar. m
2
7
Evternal groutlng.
Y23L Number of holes. nr 4
y232 Injectlon of cement grout as Speciftcation
clause 7.24. m
3
6
Renovation of exísting sewers
Y31 1 Butt fuslon wel-ded HDPE type SDR 4,
t,hickness 4 mm, 500 mm minimum lnternal-
dl-ameter. m 57
PAGE
85
CESMM3 EXAMPLES
NEWTOÑ STREET
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
EXTSTTNG PRTCK SRWER NOMTNÀI, SIZF
1200 X 900 mm. EGG SHAPEh.
Renovátlon of existing sewers.
Segmentel l lnlngs
Y333 GLass reinforced pJ-astlc as Specificatlon
cLause 7.50, minimum internal cross
sectlon dlmensions 1050 x 750 mm. m 45
Y334.l- Glass reinforced concrete, 15 mm thick'
internal cross section dlmensions
1050 x 750 mm, egg shaped. m 38
Y334.2 Gl-assreinforced concrete, 15 mm thick,
lnternal cross section dlmensions
1320 x 850 mm, curved to offset of
70 mm per metre. m 2
Ànnulus ororrti ng.
Y360 Cement grout as SpecJ.flcation
clause 7.25. m3 10
T,aterals to renovated sewers.
Joi nt i ng.
Y411 . I Bore: not exceedlng 150 mm, to HDPE
sliplining, type SDR 17. nr 10
vALr.2 Bore: 150 - 300 mm, to ITDPE sliplinlng,
type SDR 17, regarded. nr 3
Y4t 3 900 x 600 mm, egg shaped, to GRP
segmental llnlng, 15 mm thick. nr 1
PAGE
86
EXAMPLE BILL OF OUANTITIES PAGES
NE!ÍTON STREET
Number Item descrlptlon Unlt Quantlty Rate Amount
e p
FXTSTTNc RRTCK SE͡IRR NOMTNAT. STZF:
'l 200 X 900 mm, EGG SHÀPEì'I.
Renov¡tlon of e-istlng sewers.
Segmentaì I {níngs.
Y333 G1ass reinforced plastic as Specificatlon
clause 7,50, mlnimum internaL cross
sectlon dimensions 1050 x 750 mm. m 45
Y334.1 Glass reinforced concrete, 15 mm thick.
lnternal- cross section dlmensions
1050 x ?50 mm, egg shaped. m 38
Y334.2 GLass reinforced concrete, 15 mm thlck,
Internal cross sectlon dimensions
1320 x 850 mm, curved to offset of
70 mm per metre. m 2
Ànnul us orouti ngr.
Y3 60 Cement grout as Specification
clause 7.25. m3 10
Lâterals to renoveted sewêrs
Joi nt i ng
Y411 . 1 Bore: not exceeding 150 mm, to HDPE
slipJ-ining, type SDR 17. nr 10
YALL.2 Bore: 150 - 300 mm, to HDPE sIlpllnlng,
type SDR 17, regarded. nr 3
Y4 13 900 x 600 mm, egg shaped, to GRP
segmental lInlng, 15 mm thlck. nr 1
PAGE
87
CESMM3 EXAMPLES
NEWTON STREET
Unlt Quantlty Rate Amount
Number Item descrlPtlon E p
RXTSTTNG RRfCK SFVüER NOMTNAf. STZR
1200 v 900 mm, FGG St{APEfi.
Flap yaìves.
Y42l .l Remove exlstlng; nominal diameter 225 mm' nr
v42r,2 Remove existing; nomLnal dlameter 300 mm' nr
Y422 Replace existing; nominal diameter 225 mm' nr
Y423 New; HoLdwater cataLogue reference 918;
nominal dl-ameter 300 mm. nr
New manholes.
Y625 Brlck wlth backdrop type 14, heavy duty nr
cover and framei dePth 3 - 3.5 m'
Y657 Precast concreLe tyPe 2Br heavy duty cover
and frame; dePth 7'5 m. nr
Y653 Precast concrete Lype 2C, heavy duty cover nr
and frame; dePth 2 - 2.5 m.
PAGE
88
EXAMPLE BILL OF OUANTITIES PAGES
VTESTFIELD ROAD
Number Item descrlptlon Unlt Q¡antlty Rate Amount
I P
vÀr,vEs sv r 7-32
NXTSTTNG CÀST TRON MÀINS NOMTNÀI. ROREI NOT
FXCFTEI'ìTNG 200-300 mn.
v5r2 Cleanlng. m 60
Y522 Removing lntrusions. nr t5
Y542 CCTV Survey. m 60
Y562 Epoxy Ilnlng as Speclficatlon
clause 263.0'l . m 60
PAGE
89
L-.
CESMM3 EXAMPLES
NEVÙTON STREET
Number Item descrlptlon Unlt Quantlty Rate Amount
I p
FXTSTTNG FRTCK SRhIRR NOMTNAT. STZE
1200 v 900 mm, FIGG StlAPPfi.
F-l,st i na manholes
ll-rr¡ânnna¡È :c âr:ui aa )t la
Y713 Depth 2 - 2.5 n lncludlng removJ-ng cover
sIab, breaklng back shaft and backfllling
with pulverised fuel ash. nr 1
v1r7 Depth 5.5 m incl-uding removlng cover sJ.ab,
breaklng shaft and backfilJ.Ing with
pulverlsed fuel ash. nr t
Y'|20 to benchlng and lnverts, as
Itlork
drawlng 27lG incLuding brêadlng out,
re-haunching and dealing with flows. nr 1
Tnterrupt i ons ,
Y810 Prepâration of existing sev'rers. h 10
Y82 0 Stabillzatlon of existing sewers. h 10
Renov¡tion of exlstlno sewers
Y833 Segmental- Ilnings. h 20
PAGE TOT
90
EXAMPLE BILL OF OUANTITIES PAGES
GATE HOUSE
Number Item descrlptlon Unlt Ouant¡ty Rate Amount
Ê p
RARTHVÙORKS.
E*** (measúred ln accordance with cLass E)
CONCRETE.
F-Hr * * (measured in accordance wlth classes F-H)
METÀT, CT,ANNTNG.
N210 (measured in accordance with class N)
trRrCKt¡lORK, RIOCKIùORK ÀND MASONRY.
u*** (measured In accordance wlth class U)
CARPENTRY ANN JOINRRY.
Sâr.rn softr¡rood strìrcturâl end carcâssi ng
iJmhar :c ana^i fi¡¡+{¡¡ ^l ¡"-^ â, n?
ZIT2.L In walls and partltlons; 50 x 38 mm. m 22
zII2..2 In wa1ls and partltions; ?5 x 50 mm. m 36
7,LI4.I In pltched roofs; 75 x 50 mm, m 48
zLt4.2 In pitched roofs; 100 x 50 mm, nt 108
zrL4.3 In pitched roofs; 150 x 25 mm. m 18
z132 Chipboard tongued and grqoved floor
boarding 19 mm thick. m
2
20
Ml scel I eneous lol nery.
2151 hlrought softwood skirtings, flnlshed slze
150 x 19 mm, In trvo cross section shapes. fn 18
zr52 fùrouqht softwood archltraves, flnished slze
46 x L9 mm, 1n two cross sectlon shapes. m 15
PAGE TOT
91
CESMM3 EXAMPLES
GATE HOUSE
Number Item descdptlon Unlt Quantlty Rate Amount
E P
CARÞENTRY ÀNN JOTNRRY.
Misceì I aneous ioi nerv.
2153. 1 ltrought softwood beadlng, flnished size
25 x 12 mm. m I
2t53.2 Vùrought softwood capping, finlshed slze
144 x 19 run. m 2
zLs4 l{rought softwood shelves complete wlÈh all
framlng and support, 300 x 12 mm as
Drawlng No C1lGHl003. 6
Kl tchen un { ts as rlÀurore rr r¡nge
manufactured bv Kitchens Þelioht. ünit ?¡
Stânley Tndustri¡l Rstate. Cheedle F¡ulme
SK8 7JJ.
276I.L 1000 x 600 mm base unit nr 1
zr6t.2 1000 x 600 mm slnk unlt nr 1
zr62 500 x 600 mm walL unit. nr 2
zL63 2000 x 600 mm v',ork top nr I
zl69 1500 x 500 mm sJ.ngle bowL and dralner
sink unlt. nr 1
zt64 Flbreboard notlce board 2 m x 1 m x 12 mm
thlck. nr 1
7.22I FibregJ-ass guilt, 150 mn thick, lald
betvreen ceillng Jolsts. 20
^2
gùlNfiov\¡s . nooRs ANn Gf ,Àz rNG .
filrouoht softwood w'|ndows as fìr¡wlng
cA/GH l06.
2311.1 Overall- slze of opening 300 x 900 mm. nr 1
z3rr.2 Overal-l slze of opening 1500 x 1000 mm. nr I
2311.3 Overall size of openlng 1500 x 2000 mm. nr 1
z3tt.4 OveraJ.f sLze of opening 1900 x 2000 mm. nr 2
z3r3.I fürought hardwood door set type 1A as
Drawing CA/CH/O7, kept clean for stalnlng,
size 900 x 1850 mm. nr t
23t3.2 Vürought softwood doorset type 18 as
Drawlng CA/GH/l1, slze 900 x 1850 mm. nr 2
PÀGE
92
.EXAMPLE
BILL OF OUANTITIES PAGES
GATE HOUSE
Number Item descrlptlon Unlt Gluantlty Rate Amount
E p
VùTNnOT^]S, I'ìOORS ANI'ì cr,ÀZTNc.
Trannnnaarr¡ :c ñr:wi aa AL /eH /l\'1
z34L.r Paj.r of steel butt hinges; ?5 x 50 mm. nr 5
234t.2 Pair of steel butt hinges; 100 x 75 mm. nr L
2342 frSteptoe" door closers, 140 x 22 mn, nr 3
2343 149 x ?0 mm horlzontal mortice latch. nr 1
2345.r Handles; ref HI. nr 1
2345.2 Ilandles; ref H2. nr 2
GLAZTNG.
2351.1 6 mm clear float glass, fixed hrith putty. m
2
13
235r.2 5mm patterned glass as Drawlng CA/Gll/06. m
2
1
2351.3 6 mrn Georgian wlred glass in vlsLon panels
130 x 850 mm flxed wlth wöod beads. 1
^2
2355 6 mm mlrror, 600 x 600 mm ü¡Ith 4 No
drilled holes, fixed wlth dome head
mlrror screlvs. nr I
STIRF'ACE F'TNTSI]ES¡ T,TNTNGS ÀNfì PÀRTTTTONS-
Tn sltu flnlshes, heds and backlnos
Z4TT Sand and cement floor screed 38 mm thlck,
2
floated flnish. m 20
ülal I s
z4t3.L 3 mm plaster veneer coat. m
2
90
2413.2 Sand and cement backing, 6 mm thick, m
2
4
24r3.3 2 coa|. plaster 13 mm thlck. m
2
t2
z4t5 2 coaL plaster-13 mm thick to surfaces not
exceedlng i00 mm wide. m 3
PAGE
93
CESMM3 EXAMPLES
GATE HOUSE
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
suRFÀCE FTNTSHES. T'TNTNGS ANn PARTTTTONS.
O¡arry tlles as manuf¡ctured by Owen
Rrothers of Vürevham, Cìwyd.
2
z42t.r 150 x 150 x 16 mm thÍck to floors m 6
Carpet tiles, Soporo ranoe as suPplied by
Kinosland Carpets, St Àlbans, llerts'
2
z42r.2 500 x 500 squares Lo floors. m T2
fihìte ceramlc tíles as m¡nufactured hy
Owen Frothers of I¡Irevham. Cl wycl .
2
2423 100 x 100 x 6 mm thick to walls. m 4
V'|nyl sheet floor coverìnci trblue heavenrl
as supplled by Klngsland Caroets.
St Àlbans tlerts.
2
z43r 4 mm thick m 4
Plasterboard dry llningrs to walls and
,tt."hed co l rrmn s .
2
2443.L 12 mm thlck flxed wlth piaster dabs. m 45
2443.2 12 mm thlck, flxed with nails. m
2
2l
2445 12 mm thlck, foll backed, flxed with
plaster dabs, to surfaces not exceedlng
300 mm wlde. m 3
7,452 ceillng to a
'r!fel-come 2000" suspended
600 x 600qrid, 150 - 500 mm deep with
mm
6 No "Centurlan" lntegral light fittlngs 2
each 300 x 1200 mm. m 20
2480 rrHogbenrr standard slngle L-shaped ftC
cubicle partltlon comprlslng slde panel
and door complete wlth all flttlngs and
lronmongery. nr 1
PAGE
94
EXAMPLE BILL OF OUANTITIES PAGES
GATE HOUSE
Number Item descrlptlon UnIt Quantlty Rate Amount
E p
PIPED RUTT,NING SF:RVTCES.
Cold weter {nstaì lat,|on.
2511.1 Copper pipes L2 mm bore. m 25
25L1,2 Copþer plpes 18 mm bore. m t5
Copper ploe fittings.
z5L2.L 12 mm capiJ.lary bends. nr L2
25L2.2 12 mm capiJ-J-ary junctlons and branches. nr I
25t2.3 1B mm capillary bends. nr 10
25t2.4 19 mm capilJ.ary taper. nr 2
2512.5 18 mm compression bends nr 6
2512.6 18 mm compresslon Junctions and branches. nr I
7,5L2.1 18 mm compresslon valves. nr 2
Overf low plpework i nstallatl on.
2511.3 12 mm UPVC pipes. m 3
12 mm UPVC soìvent we'ìded plpe fìttlnos
2512.8 Bends. nr 6
Preformed pioework Insr'Iation 15 mm thlck
2513.1 To plpe bore 12 mm. m 25
2513.2 To plpe bore 18 mm. m 15
Rol I er pl ant and ancì ll ari es
z52L 5L electrlc water boller as SpecÍfication
clause 24.I5. nr 1
2524 MouLded plastlc 50I storage tank. nr 1
Sanltary appl lances and flttinos as
Iìyfordt s riSl mpli ci ty'r ranoe
2530.1 WC suite wlth pan, cistern, flush plpe
and seat, cataLogue ref L64 nr 1
2530,2 BowL urlnal with exposed flxlng lugs,
cJ-stern, flush pipe, waste flttlng and
trap, catalogue ref 178. nr 1
2530.3 fùash handbasln wlth brackets, plllar
taps, vJaste outlet, plug and chaln, and
trap, catalogue ref 182. nr 1
PAGE
95
CESMM3 EXAMPLES
GATE HOUSE
Unlt Quantlty Rate Amount
Number Item descrlPtlon Ê p
CAÊT,ED RUIÍ,|ìTNG SERVTCES.
z'llL PVC Insulated, 3 core, 12 mm cables lald 40
or drawn in condults. m
z7l3.L PVC, insulated, 3 core, L2 mm cables flxed
L2
to surfaces. m
cable. m L5
27t3.2 TeJ-ephone
Cable and conduit final circuits.
2712.1 Light Ing. nr 2
7,'172.2 Heating and Power '
nr t
2772.3 Motor nr 1
z'7'12.4 Water heater. nr 1
Egulpment.
218l rrvent a quIck" extract fan catalogue
ref 1I.3. nr 1
7,1lL Flt.li¡cÂ.
Swi tches.
2782.L Dtstributlon board. nr t
2782.2 Light switches; one gang. nr 2
Llght switches; two gang. nr 1
7,782.3
2783 Llght fittinqs. nr 6
Swltched pot¡rer sockets
2784.1 Slngle. nr 4
2784.2 DoubIe. nr 2
z'r82.3 Telephcjne sockets nr 2
PÀINSX.C.
v*** (measured In accordance with class V)
!i¡ATERPROOF'TNG.
hl*** (measured ln accordance wlth class W)
DRÀTNAGE TO STRUCTURFIS ABOVFI GROUNN.
x*** (measured in accordance wlth class X)
PAGE
96