0% found this document useful (0 votes)
121 views2 pages

KH-Villa Footing Design Details

This document summarizes the design of a spread footing. Key details include: - The footing is 1.7m x 1.7m x 0.25m thick and designed to support a column load of 42.657 tons. - Calculations check that the ultimate and factored soil pressures are less than the permissible pressure. Shear and moment capacities are also checked. - Reinforcements of 7 bars of 14mm diameter bars spaced at 0.258m are selected for both directions to resist the bending moments. Bond stresses are checked to be within limits.

Uploaded by

lavy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
121 views2 pages

KH-Villa Footing Design Details

This document summarizes the design of a spread footing. Key details include: - The footing is 1.7m x 1.7m x 0.25m thick and designed to support a column load of 42.657 tons. - Calculations check that the ultimate and factored soil pressures are less than the permissible pressure. Shear and moment capacities are also checked. - Reinforcements of 7 bars of 14mm diameter bars spaced at 0.258m are selected for both directions to resist the bending moments. Bond stresses are checked to be within limits.

Uploaded by

lavy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

>>>>> DESIGN OF SPREAD FOOTING

DESIGN CRITERIA Project : KH-VILLA Developer : Natthawit J.

fc' = 200 ksc. Footing : F1 Engineer : LON LAVY

fy = 4000 ksc. Filename : FOOTING2-SDM Date : July 29, 2019

PD = 23.390 ton. MD = 0.000 ton-m. Load Factor, LFD = 1.40


PL = 5.830 ton. ML = 0.000 ton-m. LFL = 1.70

Column load, Pu = 42.657 ton. Column section Pu = 42.657 ton.

Mu = 0.000 ton-m. b = 0.40 m.


Mu = . ton-m.

e = - m. h = 0.40 m. 0.50 ton/sq.m.

Footing size, S = 1.70 m.


L = 1.70 m.
Thk = 0.25 m.

Cov dc = 0.075 m.

Permissible soil pressure (qa) = 13.5 ton/sq.m.

0.25 m.
L = 1.70 m.
Factor of Safety (FS) = 3.0

Ultimate soil pressure (qult) = 40.5 ton/sq.m. 14.76 ton/sq.m. 14.76 ton/sq.m.
14.76 ton/sq.m. qnu = 14.76 ton/sq.m.
Surcharge = 0.500 ton/sq.m.
Soil pressure above footing = 2.000 ton/sq.m. Reinforcements
Total pressure under footing (q) = 13.211 ton/sq.m. OK Bar of long dir. = 14 mm. Average d = 0.161 m.

Factored soil pressure (qnu) = 14.760 ton/sq.m. Bar of short dir. = 14 mm. ɸMc = 12.342 ton-m / m width

= 14.760 ton/sq.m.

· Check two-way shear Calculation zone :

p(+d/2) = 14.760 ton/sq.m. b1 = 0.85 bc = 1.00

p(-d/2) = 14.760 ton/sq.m. rmin = 0.0018 b+d = 0.561 m.

Vup = 38.012 ton. rmax = ####### h+d = 0.561 m.

Mup = 0.000 ton-m. ɸm = 0.90 bᴏ = 2.244 m.

ɸVc = 46.04 ton. OK ɸv = 0.85 Jc = m4

vu,max = 10.52 ksc. OK ɸvc = 6.37 ksc. ɸvc2 = 15.81 ksc.

vu,min = 10.52 ksc. OK ɸvc1 = 19.47 ksc. ɸvc3 = 12.74 ksc.


· Check beam action shears
- Short panel p(+d) = 14.760 ton/sq.m. - Long panel avg.p(d) = 14.760 ton/sq.m.

Vu = 12.270 ton. Vu = 12.270 ton.

ɸVc = 17.44 ton. OK ɸVc = 17.44 ton. OK

· Reinforcements
- Long direction p(+b/2) = 14.760 ton/sq.m. - Short direction
MUS = 5.301 ton-m. MUL = 5.301 ton-m.

As = 9.54 [Link]. -- OK As = 9.54 [Link]. -- OK

As,min = 7.65 [Link]. As,min = 7.65 [Link].

Select : 7-DB14 @ 0.258 m Select : 7-DB14 @ 0.258 m


· Check bond stresses
- Reinforcement in long direction - Reinforcement in short direction

- Embedded length Lbd = 26.12 cm. < 57.5 m. OK Lbd = 26.12 cm. < 57.5 m. OK

7-DB14
7-DB14

L = 1.70 m. 0.25 m.
Remark Steel Bar on Short Direction 7-DB14 Total Amount No Need to Follow With Red Mark

You might also like