FLOATING
CORPORATE PV & DESIGN
PROFILE & QUALITY
BUSINESS PORTFOLIO CHALLENGES
2016
2017
Benefits of Floating Solar Power Generation
Regardless of the land price Cooling effect by low water temperature
Using idle water surface owned by the Gov’t Reflection and distraction on the water surface
Solving civil complaints Increased efficiency about 10% (source: K-Water)
Minimizing the destruction of natural green New demands in solar and composite materials
Excellent results in algae prevention Job creation in maintenance field in rural areas
Eco-friendly structure Artificial islands, natural learning etc. creation
(ex. Spawn for underwater creatures)
Core Technology of Floating Solar Systems
Conventional solar power generation on land is expanded to water surface.
Floating technology is added up to the existing solar power technology.
Requires technical capability to secure structural stability and durability on the water up to 20 years.
Analysis and engineering of structures Solar Power Plant Floating
to ensure safety. Technology Technology
Mooring system to fix the structures.
PV module suitable for the water environment.
Underwater cabling + connection system.
Top 15 floating solar PV plants worldwide
Rank Size (kw) Name of reservior (lake) / Name of Plant Country City/Province Operating from
1 20000 Coal mining area of Huainan City China Anhui Province April, 2016
2 7500 Kawashima Taiyou Solarpark Japan Saitama October, 2015
3 6338 Queen Elizabeth II reservoir UK London March, 2016
4 3000 Otae Province South Korea Sangju City October, 2015
5 3000 Jipyeong Province South Korea Sangju City October, 2015
6 2991 Godley Reservoir Floating Solar PV UK Godley January, 2016
7 2449 Tsuga Ike Japan Mie August, 2016
8 2398 Sohara Ike Japan Mie March, 2016
9 2313 Sakasama Ike Japan Hyogo April, 2015
10 2000 Reservior in Kumagaya city Japan Saitama December, 2014
11 2000 Kinuura Lumberyard Japan Aichi February, 2016
12 2000 Yado Ooike (Sun Lakes Yado) Japan Hyogo January, 2016
13 1751 Hirono Shinike Japan Hyogo September, 2016
14 1708 Yakenoike Japan Hyogo July, 2016
15 1700 Nishi Hiraike Japan Hyogo April, 2015
Design Configuration (Assembly Types)
Configuration
Optimum Design for High-durability Design for Structural Stability
Wind load and water surface motion consideration Optimum frame configuration to simplify load
transfer channel.
Repetitive unit assembly for easy construction +
Lightweight materials and technology to improve workability.
quality
High-durable frame members.
High-durable, high-strength structure to cope with
Proven safety through structural & fluid analysis.
- humidity, rust , saline environment
Fatigue test under 2 million cycles of dynamic load, wind
Durability secured and proven in the fatigue
tunnel test, and various load resistance & performance test
environment caused by frequent movement of water to secure structural safety.
surface.
Flat Frame
Floating Body
Configuration
The structural members (materials) are eco-friendly, high-durability FRP suitable for the wet and humid
floating environment.
The structure satisfies the IFS method of NET #758 that has the optimum configuration to support the solar
power module.
Structure & mooring connection
Footrest Vertical member
Solar power module
Maintenance area
Solar power module bearing
Diagonal bracing
member
Floating body connection
Floating body Solar power module supporting member
Configuration Details
Lateral Beam (Solar Module
Bearing Member)
Floating Solar Module Supporting
Vertical Unit Connection
Body Member
Member
Solar Module
Vertical Member Floating Member Unit Connection
Supporting Member
Configuration (Structure Material Types)
Fiber-Reinforced
Steel Aluminum PE (Polyethylene)
Plastic (FRP)
Steel it e
p os
om
Stress ()
FR PC
Strain ()
Configuration (Structure Material Types)
Structural Members (PFRP)
Vertical Members (SMC FRP)
Mooring System
Multiple auxiliary floating bodies
Uses multiple auxiliary floating bodies.
Uses multiple auxiliary weights.
Operated solely by the gravity of auxiliary
weights without any mechanical system.
Suitable for sites with deep water and big
difference in water level.
Auxiliary mooring structure
Auxiliary
weights and mooring anchors are
connected through mooring lines.
Indirect
areas are reduced through auxiliary
structures.
Operatedsolely by the gravity of auxiliary
weights without any mechanical system.
Suitablefor sites with deep water and big
difference in water level.
Environmental Impact Assessment
Environmental Impact Assessment
Construction Process
Material Delivery
Unit Build-up
Construction Process
Dispatching Unit
Assembling
Construction Process
Mooring
Completion
Design Samples in Korea
30kWp Floating Solar Power System, Cheongho Lake, Buan, Jeonbuk
Korea Rural Community Corporation, 2012
Design Samples in Korea
1,000kWp Floating Solar Power System for Water Inlet at Dangjin Thermal Power Plant,
East-West Power Co., Ltd., 2013
Design Samples in Korea
100kWp Tracking Floating Solar Power System for Hapcheon Dam, Gyeongnam
K-Water, 2013
Four circular structures (25kW) are rotated to track the sun.
Design Samples in Korea
48kWp Floating Solar Power System on Gasa Island, Jeonnam
Korea’s first energy-independent island’s micro grid model
Supplies power to islands
World’s 4th largest floating solar system
Floating Solar Power System on Sang Ju, Kyoung Buk
LG CNS, 2015
The First Project-Financing Model.
THANK YOU
Veyis Neo Toprak
Smart Energy Biz Division
General Manager
[email protected]