0% found this document useful (0 votes)
403 views3 pages

EasyLogic PM2120 Power Meter Datasheet

The document provides product data for the EasyLogic PM2120 power and energy meter. Key details include: - It is a class 1 power meter that measures up to the 15th harmonic and supports RS485 communication. - Measurement capabilities include voltage, current, power, energy, power factor and harmonic distortion. It has an accuracy of +/-1% for power, energy and other measurements. - Operating conditions include a temperature range of -10°C to 60°C, altitude up to 2000m, and IP54 protection rating. Communication is via Modbus RTU protocol. - Certifications include CE, UL, CSA, RCM, EAC and C-Tick. It has

Uploaded by

Satu Whandaru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
403 views3 pages

EasyLogic PM2120 Power Meter Datasheet

The document provides product data for the EasyLogic PM2120 power and energy meter. Key details include: - It is a class 1 power meter that measures up to the 15th harmonic and supports RS485 communication. - Measurement capabilities include voltage, current, power, energy, power factor and harmonic distortion. It has an accuracy of +/-1% for power, energy and other measurements. - Operating conditions include a temperature range of -10°C to 60°C, altitude up to 2000m, and IP54 protection rating. Communication is via Modbus RTU protocol. - Certifications include CE, UL, CSA, RCM, EAC and C-Tick. It has

Uploaded by

Satu Whandaru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Product data sheet METSEPM2120

Characteristics EasyLogic PM2120, Power & Energy meter, up


to 15th H, LED, RS485, class 1

Main
Range EasyLogic
Product name EasyLogic PM2100
Device short name PM2120
Product or component Power meter
type

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Complementary
Device application Sub billing
Power monitoring
Power quality analysis Total harmonic distortion
Up to the 15th harmonic
Type of measurement Apparent power min/max, total
Active and reactive power min/max, total

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Current min/max, avg
Voltage min/max, avg

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy total
Metering type Current I, I1, I2, I3
Peak demand power PM, QM, SM
Active, reactive, apparent energy (signed, four quadrant)
Peak demand currents
Active power P, P1, P2, P3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Unbalance current
Reactive power Q, Q1, Q2, Q3
Demand power P, Q, S
Apparent power S, S1, S2, S3
Accuracy class Class 1 active energy conforming to IEC 62053-21
Class 1 reactive energy conforming to IEC 62053-24
Class 5 harmonic distorsion (I THD & U THD)
Measurement accuracy Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current 5…6000 mA
Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range 45…65 Hz
[Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 %
44...277 V DC +/- 10 %
Network frequency 50 Hz
60 Hz

Nov 24, 2019


1
Ride-through time 100 Ms 120 V AC typical
400 Ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current 1 A
5 A
Maximum power consumption in VA 6 VA at 277 V AC
Maximum power consumption in W 3.3 W (power lines (AC))
2 W at 277 V (power lines (DC))
Input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settings Protected by access code
Display type 7 segments LED
Display colour Red
Messages display capacity 3 fields of 4 characters
Display digits 12 digit(s) - 14.2 mm in height
Demand intervals Configurable from 1 to 60 min
Information displayed Demand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type 3 x button
Local signalling Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Number of inputs 0
Number of outputs 0
Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2
wires, insulation 2500 V
Communication port support Screw terminal block: RS485
Data recording Time stamping
Min/max for 8 parameters
Function available Real time clock
Sampling rate 64 samples/cycle
Cybersecurity Enable/disable communication ports
Communication service Remote monitoring
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
Mounting mode Clip-on
Mounting position Vertical
Mounting support Framework
Provided equipment 1 x installation guide
Measurement category Category III 480 V
Category II 480…600 V
Electrical insulation class Double insulation
Class II
Flame retardance V-0 conforming to UL 94
Connections - terminals Current transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4
Material Polycarbonate
Width 96 mm
Depth 76.09 Mm total:
61.64 mm embedded:

2
Height 96 mm
Net weight 300 g
Compatibility code PM2120

Environment
Service life 7 year(s)
IP degree of protection IP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity 5…95 % at 50 °C
Pollution degree 2
Ambient air temperature for operation -10…60 °C
Ambient air temperature for storage -25…70 °C
Operating altitude <= 2000 m
Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC
61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Overvoltage category III

Offer Sustainability
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
WEEE The product must be disposed on European Union markets following specific
waste collection and never end up in rubbish bins

You might also like