Adani Question Paper (NPTI, Nagpur)
Date: 02/01/2010
Descriptive Questions:
• How Nox is controlled?
• What is the use of Barring gear?
• Why is the combination of convective and radiant type superheater used?
• What are the diff type of fans used in power plant?
• What are the diff type of governing system used in power plant?
• What are the various type of ckt breaker used in super thermal power plant?
• What are the diff voltage levels used in STPP?
• Why DG sets and Dc supply used in poweplant?
• Why is regenerative feed heating system used in pp?
• Why are orifice plate used at the inlet of waterwall tube?
• Why is acid cleaning of boiler done?
• Why is the rankine cycle used in pp called as modified rankine cycle?
• What are the diff method of coal anaylsis?
• Why is vaccum pump use in PP?
• What are the diiff factors affecting condenser vaccum?
• Why are soot blowers used?
• Why 20% excess air is allowed in furnace?
• Why turbines are made double flow in modern TPPs?
• What is difference b/w dry bottom furnace and wet bottom furnace?
• How is the temp of HRH controlled?
Fill in The blanks:
• Reaction turbine has______type of blades.
• Sepration of water and steam in drum take place due to there ______diffrence.
• _____extracts heat fronm flue gases after economizer.
• Steam is allowed to enter the turbine after main steam temp>______o C superheat.
• Thermal pp use_____phase cycle.
• Pulvrisers redused the size of coal to _____ size.
• Isolator cannot be opened if____ is closed.
• CBD is used to control _____ in drum water.
• ______ is used in/pump for balancing residual thrust.
• NH3 is used to maintain ____ in feed water.
True or False:
• Natural circulation boiler is more efficient than oncethrough boiler.
• The temp of flue gases at the exit of chimney is kept above the acid dew point temp.
• Fire water pump is used for sprinkling .
• Dearator is direct contact type of heat exchanger.
• VFD is the most efficient method of controlling fan speed.
• Boiler drum is used for separation of water and steam.