161-174 Meters PDF
161-174 Meters PDF
161
Liquid Controls Meters
MA Series Meters
For operation at any non-shock working pressure up to 350 PSI
(25 bar) and at ambient temperatures up to 160°F (71°C).
• Size for size, LC MA Series Meters are lighter and provide
greater mounting flexibility.
• Accessories may be rotated 180 degrees or covers swapped
to reverse direction of flow from L to R or R to L. No
additional parts or special tools required.
MA 4 Meters
For LPG Motor Fuel Applications
Rate of flow 5 to 30 GPM (20-1 15 L/min.) capacity range.
Choice of 3⁄4", 1 1⁄2", and 2" companion flanges. UL listed.
Model # Description
Standard meter w/air eliminator, strainer
MA-4-CX-10
differential valve & counter
Same as MA-4-CX-10 except: w/temperature
MA-4-CY-10
volume compensator
MA-4-GX-10 Same as MA-4-CX-10 except: w/printer
Same as MA-4-CX-10 except: w/printer &
MA-4-GY-10
temperature volume compensator
MA 5 Meters
For Truck & High Speed Motor Fuel Applications MA-4-CX-10, MA-5-CX-10
Rate of flow 12 to 60 GPM (45-225 L/min.) capacity range. Shipping wt. 95 lbs.
Choice of 1 1⁄2" standard, and 2" optional companion flanges.
Model # Description
Standard meter w/air eliminator, strainer,
MA-5-CX-10
differential valve, and counter.
Same as MA-5-CX-10 except:
MA-5-CY-10
w/temperature volume compensator
MA-5-GX-10 Same as MA-5-CX-10 except: w/printer
Same as MA-5-CX-10 except:
MA-5-GY-10
w/printer & temperature volume compensator
162
Liquid Controls Meters
MA-7-GY-10
Shipping wt. 110 lbs.
163
Liquid Controls Parts
®
NO.
VOL/REV
ACCURA
CY
MAX PRES
TURE
PRODUC SURE
T
UK81
342 48276 1 Gear, Output 1783
773
772 Washer
575
Keys, (3) Washer, pinion
611
Screw, cap-(8) 153
Rotor, blocking 635
161 Screw, shoulder
Gear, blocking rotor
342
672 Gear, output
Screw, cap-(3)
144
Plate, front bearing
430
771 O-ring, meter cover (2)
Washer, 155
rotor gear-(3) Rotor,displacement (2) 110
Housing, M5-Aluminum
163 318
Gear, Pins, dowel-(4)
displacement pinion (2) 146
Plate, rear bearing
164
Liquid Controls Parts
202
0
Adjuster assy.
123 49449 48301 1 Cover, Front 0
1
2
2
1
4
5
6
ACCURA
VOL/REV
CY
TEMP ERA
TURE
366 49390 1 Plate, Cover Adjuster PRODUC
T
FLOW
RATE
MAX PRES
SURE
UK81
1783
375 48208 1 Bushing Retainer
165
430 O6850 O9258 1 O-Ring 6.25 ID Buna-N Gear, packing gland
463 O6856 417862 2 O-Ring .88 ID Buna-N 250 705
Packing gland assy. Washer, flat (4)
528 48332 3 Key, Stainless Steel 673
Screw (4)
566 O6790 20 Pipe Plug 463
O-Ring
574 O2188 1 Retainer Ring
780
603 O6845 2 Screw, #10-24 X .375 Seal wire
153
611 Rotor, blocking
Screw, hex head
w/lockwasher (6 per plate)
161 528
Gear, Key (3) (1 per rotor)
blocking rotor
326
Driver,
*675 packing gland
Screw,
cap socket head
RP.
LS CO
CONTRO A
LIQUID BLUFF, IL, US
LAKE L NO.
MODE
NO.
SERIAL
®
765
Washer, Lock
673 318
Screw, Pin, dowel (4)
hex washer head (2) 163
Gear, Plate, serial number
displacement pinion (2) 144 155
771 Plate, bearing (2) 110
Dome washer, rotor gear (2) Rotor, displacement (2)
Housing
165
Liquid Controls Parts
618 625
Reed-to-housing Screw
screw
230
Float & reed assy.
218
Baffle cup
428
O-ring
450
O-ring 632
Screws, (4)
720
Washers, flat
632
Screws, (4)
130
Cover, strainer basket 720
Washers, flat
166
Liquid Controls Parts
CAUTION
Diaphragm Replacement
Before removing any bolts from the cover, the threaded rod (3/8-16 UNC all-thread bolts 6” long), washer (1 1/2” diameter)
and 3/8” nut must be in place to keep spring compressed. The threaded rod is inserted through the cover center hole and
screwed securely into threaded hole in diaphragm nut. The washer is then placed onto the rod and the nut is screwed down
until spring pressure is felt. The cover bolts can now be removed and cover taken off.
The Diaphragm assembly can be removed from cover by slowly loosening the nut on the threaded rod until spring returns
to its free length and exerts no pressure on the assembly. CAUTION MUST BE TAKEN TO MAKE SURE THE THREADED
ROD DOES NOT UNSCREW FROM THE DAIPHRAGM NUT BEFORE SPING PRESSURE IS TAKEN OFF THE
ASSEMBLY. The nut and washer are then removed to take apart diaphragm assembly, spring and cover.
325
345
715
615
167
Neptune Meters
New Old
Model #
Description Capacity
Model #
RL100-108A1a 400051-VR With Veeder-Root register only
3-18 gpm
RL100-118A2b 400051-002 With register & ATC
400051
Shipping wt. 24 lbs.
RL200-21RGD2
Shipping wt. 144 lbs.
168
Parts - Neptune Meters
Temperature Compensator 1
7 O-ring 100139-005 4
9 Cover 600443-001
14 Adapter 85006-000 —
18 Expander 83539-000
20 O-ring 100138-003
13
21 14
10 17
18
19
11
20
12 15
13
16
Measuring Chamber
Part #
Index Description
1 1/4" 1 1/2" 2" 4
1 Gasket 4862-008 84806-000
169
Parts - Neptune Meters
Strainer cover
13 83485-702 400074-001
(with thermometer well)
Strainer cover
83486-705 600103-000
(without thermometer well)
Differential Valve
Part #
Index Description
1 4
1 /" 1 1/2" 2" 1
1 Spring, valve 83775-000 2 3
7 4
Diaphragm, complete 1001571 1001569
8 5
2 Screw, diaphragm 83774-002 9 6
3 Lockwasher, 7/16" steel 41012-002
6 Diaphragm 1000624
170
Parts - Neptune Meters
3
⁄4" & 1" Fill Station Type 4D & 4D-MD 1
⁄4" Type 4D
3
24
Part #
Index Description 2
3
/4" 1"
9
1 Register complete 600 series/ga..l 100498-009 100498-016
15 Spring 100024-001 10
4
16 Cover o-ring 100139-007
171
Registers
Veeder-Root Registers
Large Numeral Counter (Register)
A large numeral Counter registers the amount of each delivery
or batch and provides a five-figure reset totalizer.
Part # Description
789002-002 Register/printer for Neptune style ticket
788700-002
788700-002 Register only Register only
789002-002
E788700-002 Exchange register
Change Gears
When ordering change gears, the last two numbers of the part
number need to be the number of teeth on the gear.
(ex. Veeder-Root change gear 32996-024)
Description Part #
Neptune Registers
Neptune registers provide high reliability and readability.
Model # Part # Register Type Description
100498-009 Non-print register for 3/4"
631 Direct read
100498-016 Non-print register for 1"
Direct read w/
833 880030-000 Print register for 1 1/4 " and above
ticket printing
833 100447-101 – Weather Shield
172
Troubleshooting Guide - Neptune Meters
To guarantee that your neptune meter performs at its best, always use Genuine Neptune Parts.
Register Does Not Run When Meter Is In Operation B. While the register is off the meter, check the star drive gear
A. Loosen the two square-head clamp screws at the front on the meter to make sure it is not slipping on the gear train
base of the register. Remove the register & look into the shaft. If loose, tighten the alien set screw. Also, check the
bottom at the change gears. Each change gear has a shear gear train by rotating the star gear with your fingers. You
strip in the center hub. If broken, replace complete gear should be unable to turn the star gear a full revolution
with another that has the same number of teeth (part unless the gear train is broken and must be replaced.
#81230 - Teeth No.)
Register Creeping
If the meter creeps a few tenths when the pump is engaged, it If the problem exists after replacing the inlet, check valve as-
is probably caused by a worn out or metal-seat inlet check sembly, check the delivery hose and nozzle for leaks. If the
valve. This assembly is found where the supply piping enters meter creeps continuously with the pump engaged and delivery
the vapor release unit. Replace old assembly with a new rubber nozzle closed, the diaphragm (U-cups on 3⁄4") in the differential
seat assembly, which gives a positive seal that prevents bleed valve most likely has a hole in it and needs replacing. This hole
back of LPG from the meter. would allow LPG to circulate through the meter & back to
storage through the connector and vapor return line (see above).
NOTE: IT IS NOT RECOMMENDED TO REUSE OLD GASKETS
173
Vapor Meter
Meter
Part # Description Connection Weight
Temperature Compensated
METRIS250TC Vapor Meter 20LT 8#
(Industry Standard)
Maximum Working Pressure 5#
Accessories
Part # Description
METRIS-CONNECT 3/4” Nipple (2 Required) X 20LT
METER-BAR-R 3
⁄4” x 1” Polyester coated meter bar
Meter Capacity at Various Inlet Pressures for Propane 1.53 sp. gr.
Replacement
Inlet Pressure Capacity CFH Approx. BTU
Index Face
11" w.c. 202 508,000 Metris Index 11
2 psi 534 1,343,000 Metris Index 2
5 psi 607 1,528,000 Metris Index 5
174