0% found this document useful (0 votes)
109 views1 page

Quick PF Modular Surge Arrester

1. This document provides product specifications for a Quick PF modular surge arrester for a 1 pole + N configuration with a rated operational voltage of 230V AC. 2. Key specifications include a nominal discharge current of 10kA for common mode and 5kA for differential mode, a maximum discharge current of 10kA for both common and differential mode, and a voltage protection level of 1.5kV for type 2 differential and common mode. 3. The surge arrester uses MOV and GDT technology, has an integrated 6kA circuit breaker, and mounts on a DIN rail.

Uploaded by

Las Ukcu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views1 page

Quick PF Modular Surge Arrester

1. This document provides product specifications for a Quick PF modular surge arrester for a 1 pole + N configuration with a rated operational voltage of 230V AC. 2. Key specifications include a nominal discharge current of 10kA for common mode and 5kA for differential mode, a maximum discharge current of 10kA for both common and differential mode, and a voltage protection level of 1.5kV for type 2 differential and common mode. 3. The surge arrester uses MOV and GDT technology, has an integrated 6kA circuit breaker, and mounts on a DIN rail.

Uploaded by

Las Ukcu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Product data sheet 16617

Characteristics Quick PF modular surge arrester - 1 pole + N -


275V

Main
Range of product Quick PF
Product or component Surge arrester
type
Device short name Quick PF
Poles description 1P + N
Remote signalling Without
Surge arrester type Electrical distribution network
Earthing system TN-S
TT

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Complementary
Surge arrester class type Type 2
Surge arrester technology MOV + GDT
[Ue] rated operational voltage 230 V (+/- 10 %) AC 50/60 Hz
[In] nominal discharge current Common mode : 10 kA N/PE
Differential mode : 5 kA L/N

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
[Imax] maximum discharge current Differential mode : 10 kA L/N

This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Common mode : 10 kA N/PE

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
[Uc] maximum continuous operating voltage Differential mode : 275 V L/N
Common mode : 275 V N/PE
[Up] voltage protection level 1.5 kV type 2 differential mode L/N
1.5 kV type 2 common mode N/PE
[If] follow current 0.1 kA common mode N/PE
Disconnector device type Integrated circuit breaker Icu 6 kA
[Isccr] short-circuit current rating 25 kA
Local signalling Flag color: white/red
Mounting mode Clip-on
Mounting support DIN rail
9 mm pitches 4
Height 109.7 mm
Width 36 mm
Depth 72.1 mm
Colour Grey ( RAL 7035 )
Response time <= 25 ns
Connections - terminals Tunnel type terminal upside 2.5...25 mm²
Tunnel type terminal downside 2.5...25 mm²
Tightening torque 2.5 N.m

Environment
Quality labels OVE
IP degree of protection On terminal : IP20
On front face : IP40
IK degree of protection IK03
Relative humidity 5...90 %
Ambient air temperature for operation -5...40 °C
Ambient air temperature for storage -40...85 °C

Feb 14, 2015


1