Carrier
TRANSICOLD
REFRIGERATION CONNECTION
CPR ADJUSTMENT & INTEGRA 35 X
CHARGE
TXV ADJUSTEMENT
P/N : 62-61309-01 / rev B
Downloaded from [Link] manuals search engine
Carrier
TRANSICOLD
ITEM P/N
90° ORS 1/4->3/8" 40-60048-01
90° ORS 3/8" 40-60048-02
Liquid 135° ORS 3/8" 40-60049-02
Road Suction Standby suction 90° ORS 3/8"
90° ORS 3/4" 90° ORS 5/8" Check valve 90° ORS 1/2" 40-60048-03
Hot gas With HGS2 only 90° ORS 5/8" 40-60048-04
90° ORS 3/8" 90° ORS 3/4" 40-60048-05
135° ORS 1/2"-->5/8" 40-60049-06
90° O-RING 5/8" 40-60061-04
90° O-RING 1/2" 40-60061-03
180° O-RING 1/2" 40-60060-03
90° O-RING 5/8" 40-60061-04
180° O-RING 5/8" 40-60060-04
90° O-RING 5/8"->3/4" 40-60061-07
180° O-RING 5/8"->3/4" 40-60060-07
HP SERVICE VALVE 1/2" 40-60059-03
LP SERVICE VALVE 3/4" 40-60058-05
CLAMP 3/8" (mod 6) 34-60019-02
CLAMP 1/2" (mod 8) 34-60019-03
Road suction LP service valve CLAMP 5/8" (mod 10) 34-60019-04
O-Ring pilot 3/4" 3/4"
CLAMP 3/4" (mod 12) 34-60019-05
HOSE 3/8" (mod 6) 58-60115-02
HOSE 1/2" (mod 8) 58-60115-03
HOSE 5/8" (mod 10) 58-60115-04
HOSE 3/4" (mod 12) 58-60115-05
HP service valve, 1/2"
CHECK VALVE 3/8" (option) 14-00286-00
Road discharge
O-Ring pilot 1/2"
Liquid
180° ORS 3/8"
Standby suction
Hot gas
Road discharge 90° O-RING 5/8"
90° ORS 3/8"
90° ORS 1/2"
Oil return
90° ORS 1/4"->3/8"
Downloaded from [Link] manuals search engine
Carrier
TRANSICOLD
Standard
OPERATING CONDITIONS
Road ONLY (2400 rpm)
Heating or Defrost mode
Standard + 0,3
Run the unit on " HEAT or DEFROST " mode
Adjust the CPR to get the following gauge pressure values
3m
STANDARD ADJUSTMENT
6m
XARIOS 350 : 2,4 bars (35 psig) ! Pressure value is given at the CPR port
! CPR adjustment must be increased by :
0,1(bar) x D(m)
Standard + 0,6
D : Evaporator location from the front of the box (in meter)
Downloaded from [Link] manuals search engine
Carrier
TRANSICOLD
OPERATING CONDITIONS
Road (2400 rpm) or Standby mode
Superheat area
Run the unit on " COOL " mode
INITIAL CHARGE P0 - T0
XARIOS 350 = 1,7 Kg Beginning of
evaporating
Evaporating of the last liquid drop
COMPLETE THE CHARGE ON THE SIGHT GLASS T1
! AT 0°C BOX TEMPERATURE Remote the bulb location
Po : Pressure at manifold
To : Temperature at manifold
T1 : Temperature with thermocouple
SUPERHEAT = To - T1
The superheat should be :
! 8°C at 0°C box T° (14.4°F at 32°F box T°)
4°C at -20°C box T° (7.2°F at -4°F box T°)
Downloaded from [Link] manuals search engine