100% found this document useful (1 vote)
965 views4 pages

Xarios 350 Service and Adjustment Guide

This document provides instructions for adjusting refrigeration connections and TXV settings on a Carrier Transicold refrigeration unit. It includes a diagram labeling refrigeration connection ports and components. It also provides standard adjustment procedures for the CPR and TXV based on operating conditions and evaporator location within the refrigerated space.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
965 views4 pages

Xarios 350 Service and Adjustment Guide

This document provides instructions for adjusting refrigeration connections and TXV settings on a Carrier Transicold refrigeration unit. It includes a diagram labeling refrigeration connection ports and components. It also provides standard adjustment procedures for the CPR and TXV based on operating conditions and evaporator location within the refrigerated space.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Instructions Overview
  • Refrigeration Connection Notice
  • CPR Adjustment
  • Refrigerant Charge and TXV Setting

Carrier

TRANSICOLD

REFRIGERATION CONNECTION
CPR ADJUSTMENT & INTEGRA 35 X

CHARGE
TXV ADJUSTEMENT

P/N : 62-61309-01 / rev B

Downloaded from [Link] manuals search engine


Carrier
TRANSICOLD

ITEM P/N
90° ORS 1/4->3/8" 40-60048-01
90° ORS 3/8" 40-60048-02
Liquid 135° ORS 3/8" 40-60049-02
Road Suction Standby suction 90° ORS 3/8"
90° ORS 3/4" 90° ORS 5/8" Check valve 90° ORS 1/2" 40-60048-03

Hot gas With HGS2 only 90° ORS 5/8" 40-60048-04


90° ORS 3/8" 90° ORS 3/4" 40-60048-05
135° ORS 1/2"-->5/8" 40-60049-06
90° O-RING 5/8" 40-60061-04
90° O-RING 1/2" 40-60061-03
180° O-RING 1/2" 40-60060-03
90° O-RING 5/8" 40-60061-04
180° O-RING 5/8" 40-60060-04
90° O-RING 5/8"->3/4" 40-60061-07
180° O-RING 5/8"->3/4" 40-60060-07
HP SERVICE VALVE 1/2" 40-60059-03
LP SERVICE VALVE 3/4" 40-60058-05
CLAMP 3/8" (mod 6) 34-60019-02
CLAMP 1/2" (mod 8) 34-60019-03
Road suction LP service valve CLAMP 5/8" (mod 10) 34-60019-04
O-Ring pilot 3/4" 3/4"
CLAMP 3/4" (mod 12) 34-60019-05
HOSE 3/8" (mod 6) 58-60115-02
HOSE 1/2" (mod 8) 58-60115-03
HOSE 5/8" (mod 10) 58-60115-04
HOSE 3/4" (mod 12) 58-60115-05
HP service valve, 1/2"
CHECK VALVE 3/8" (option) 14-00286-00

Road discharge
O-Ring pilot 1/2"

Liquid
180° ORS 3/8"

Standby suction
Hot gas
Road discharge 90° O-RING 5/8"
90° ORS 3/8"
90° ORS 1/2"
Oil return
90° ORS 1/4"->3/8"

Downloaded from [Link] manuals search engine


Carrier
TRANSICOLD

Standard

OPERATING CONDITIONS
Road ONLY (2400 rpm)
Heating or Defrost mode
Standard + 0,3

Run the unit on " HEAT or DEFROST " mode

Adjust the CPR to get the following gauge pressure values

3m
STANDARD ADJUSTMENT
6m
XARIOS 350 : 2,4 bars (35 psig) ! Pressure value is given at the CPR port

! CPR adjustment must be increased by :

0,1(bar) x D(m)
Standard + 0,6
D : Evaporator location from the front of the box (in meter)

Downloaded from [Link] manuals search engine


Carrier
TRANSICOLD

OPERATING CONDITIONS
Road (2400 rpm) or Standby mode

Superheat area
Run the unit on " COOL " mode

INITIAL CHARGE P0 - T0
XARIOS 350 = 1,7 Kg Beginning of
evaporating
Evaporating of the last liquid drop
COMPLETE THE CHARGE ON THE SIGHT GLASS T1
! AT 0°C BOX TEMPERATURE Remote the bulb location

Po : Pressure at manifold
To : Temperature at manifold
T1 : Temperature with thermocouple

SUPERHEAT = To - T1
The superheat should be :
! 8°C at 0°C box T° (14.4°F at 32°F box T°)
4°C at -20°C box T° (7.2°F at -4°F box T°)

Downloaded from [Link] manuals search engine