Table 8.
13: HAZOP for Reactor R-102
Project Name: Production of 10000 Metric Tonnes Date: 05/05/2020 Page: 2 of 6 Assigned to: Safety,
of Bioethanol Health and Environment
Department
Process: Neutralization of hydrolysate from Sulphuric acid by using Calcium Hydroxide
Section: R-102 Prepared by: Mohamad Afie bin Rosman
Item Study Node Process Deviation Possible Causes Possible Consequences Action Require
Parameter
1. Continuous Flow No Inlet line rupture Neutralization not Periodic
Stirred Tank Fail to open the occur (high content maintenance of
Reactor control valve of sulphuric acid) control valves
(CSTR), system Blast and rupture of Visual inspection
Neutralizer R- Blockage happen in pipeline may occur of pipelines
102 the piping system
Low Plugging and Neutralization take Installation of
broken pipe longer time to alarm or indicator
Blockage happen complete for flow in the
in the piping Outlet pipeline
system concentration of Periodic
Control valve Sulphuric acid maintenance of
system for higher control valves
reactants flow not Visual inspection
working properly of pipeline
High Control valve Loss of reactant due Installation of
system for to overflow alarm or indicator
reactants flow not Increase of reactor for temperature in
working properly temperature the pipeline
Ineffective Periodic
neutralization maintenance of
process control valves
Blast and rupture of Visual inspection
the reactor may of pipeline
happen
2. Continuous Temperatur Low Excessive removal Reduce reaction Installation of
Stirred Tank e of heat due to low rate hence reaction alarm or indicator
Reactor flow of steam for take longer time for temperature in
(CSTR), the reactor Not able to achieve the reactor
Neutralizer R- Control valve desired reaction Increase steam
102 system for the temperature flow to the
steam flow not Ineffective reactor’s heating
working properly neutralization system
process Periodic
maintenance of
control valves
High Excessive Increase of reactor Installation of
introduction of temperature alarm or indicator
heat due to high Ineffective for temperature in
flow of steam for neutralization the reactor
the reactor process Decrease steam
Control valve Blast and rupture of flow to the
system for the the reactor may reactor’s heating
steam flow not happen system
working properly Periodic
maintenance of
control valves
3. Continuous Level Low Control valve Ineffective Installation of
Stirred Tank system for neutralization alarm or indicator
Reactor reactants flow not process for level in the
(CSTR), working properly Increase the reactor reactor
Neutralizer R- Blockage may temperature Periodic
102 happen in the Quality of product maintenance of
pipeline reduced control valves
Leakage of the Visual inspection
piping system of pipeline
High Control valve Reactant and Installation of
system for product losses alarm or indicator
reactants flow not Reaction for level in the
working properly temperature not reactor
Outlet pipeline achieved Periodic
clogged Product quality not maintenance of
achieved control valves
Visual inspection
of pipeline
4. Continuous Agitation No Agitator motor Slow reaction rate Motor to be
Stirred Tank mixing failure Product quality not checked
Reactor Shaft seal failure achieved periodically
(CSTR), Proper lubrication
Neutralizer R- of motor
102 Slow Corrosion of the Proper mixing does Proper
mixing impeller not happen maintenance of
Wear or tear on the Product quality not motor
agitator motor achieved Proper lubrication
Gear, belt or shaft of motor
damage
More Gear failure Impeller runs in Proper inspection
mixing high rpm and maintenance