0% found this document useful (0 votes)
391 views2 pages

Mastertile 530: Description Coverage / Yield

This document provides information about MasterTile 530, a latex modified cement grout for ceramic, glass mosaic, porcelain and non-moisture sensitive natural stone tiles. It describes the product, including its advantages, applications, coverage, packaging, storage, health and safety, and technical properties.

Uploaded by

bassem muhanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
391 views2 pages

Mastertile 530: Description Coverage / Yield

This document provides information about MasterTile 530, a latex modified cement grout for ceramic, glass mosaic, porcelain and non-moisture sensitive natural stone tiles. It describes the product, including its advantages, applications, coverage, packaging, storage, health and safety, and technical properties.

Uploaded by

bassem muhanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

MasterTile® 530

Coloured, latex modified cement grout for ceramic, glass mosaic, porcelain and non-moisture
sensitive natural stones tiles

DESCRIPTION COVERAGE / YIELD


MasterTile 530 is a fine coloured latex modified 1 kg is sufficient for approximately 4 m² using
powder which, when mixed with water, gives a standard 150 x 150 mm tiles.
smooth, easily applied creamy paste for clean 10 kg bag mixed with 3.3 L of water yields
grouting of ceramic tiles. It sets to a decorative approximately 7.50 L
water-resistant finish. 18 kg bag mixed with 5.94 L of water yields
approximately 13.50 L
ADVANTAGES
 Water-resistant (suitable for swimming pools) WATCHPOINTS
 Available in a range of colours Certain types of tile may stain when in contact with
 Resistant to cracking in joints up to 6mm wide coloured cement grouts, it is therefore advisable to
 Ideal for internal and exterior applications consult the tile manufacturer and carry out trials
 Formulated for Middle East conditions before use.
 Resistant to mould growth
For natural stone tiles susceptible to staining,
please contact BASF Technical Services.
MasterTile 530 is a blend of hydrophobic cement,
fillers and organic additives.
STORAGE AND SHELF LIFE
PACKAGING Store out of direct sunlight, clear of the ground on
pallets protected from rainfall. Avoid excessive
MasterTile 530 is available in 10 kg and 18 kg
compaction.
sacks.
Shelf life is 12 months when stored as above, in
original, unopened bags.
STANDARDS
BS 5980 - Cementitious Adhesives and Grouts
ANSI 118.7 (Polymer Modified Cement Grouts)
BS EN 13888 CG2

TYPICAL PROPERTIES*

Mixed density @25°C 1777 kg/m³

APPLICATION GUIDELINES
Allow at least 24 hours between fixing tiles and
grouting. Mix grout powder with water to give a
smooth, thick consistency.

Leave to stand for 15 minutes before using. Apply


to tile joints with a squeegee, brush or sponge.
Remove surplus grout with a damp sponge. When
grouting is completed, polish tiles with a dry cloth.

WATER ADDITION
3.3 L per 10 kg bag
5.94 L per 18 kg bag
MasterTile® 530

HEALTH AND SAFETY


As with all chemical products, care should be
taken during use and storage to avoid contact with
eyes, mouth, skin and foodstuffs (which may also
be tainted with vapour until product is fully cured).
Treat splashes to eyes and skin immediately. If
accidentally ingested, seek immediate medical
attention. Reseal containers after use.

QUALITY AND CARE


All products originating from BASF’s Dubai, UAE
facility are manufactured under a management
system independently certified to conform to the
requirements of the quality, environmental and
occupational health & safety standards ISO 9001,
ISO 14001 and ISO 45001.

® = Registered trademark of the BASF-Group in many countries.

BASF_CC-UAE/Tile_530_09_01/v5/07_17/v6/04_18/v7/09_19
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


P.O. Box 37127, Dubai, UAE
Tel: +971 4 8090800, Fax: +971 4 8851002
www.master-builders-solutions.basf.ae

Disclaimer: the LRQA mark relates to


certified management system and not to the
product mentioned on this datasheet

You might also like