0% found this document useful (0 votes)
132 views2 pages

SP510 Hardness Analyzer for Water Softening

The SP510 Hardness Analyzer continuously monitors water hardness in real-time to detect when a water softener's capacity is exhausted. It signals when regeneration is needed to make the softening system more efficient and reduce costs. The analyzer is rugged, lightweight, self-contained, and easy to maintain, requiring replenishing reagents every two months. It reliably detects hardness levels from 0.3 to 100 ppm to immediately trigger regeneration only when necessary.

Uploaded by

Sugeng Yulianto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
132 views2 pages

SP510 Hardness Analyzer for Water Softening

The SP510 Hardness Analyzer continuously monitors water hardness in real-time to detect when a water softener's capacity is exhausted. It signals when regeneration is needed to make the softening system more efficient and reduce costs. The analyzer is rugged, lightweight, self-contained, and easy to maintain, requiring replenishing reagents every two months. It reliably detects hardness levels from 0.3 to 100 ppm to immediately trigger regeneration only when necessary.

Uploaded by

Sugeng Yulianto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

SP510 Hardness Analyzer (1 mg/L trip point)

Product #: 5410001
USD Price: $2,571.00
Ships within 2 weeks

Maximize your softener cycle time and minimize your regeneration cost.
Immediately signal hardness breakthrough to activate regeneration. Makes your water softening system more efficient and less costly. Reliable,
simple and accurate- with automated calibration. Continuous monitoring in "real time".

Continuous hardness detection


The SP510 monitor detects hardness breakthrough when the capacity of a water softener is exhausted, immediately signaling the need
for regeneration. Alarm points are 0.3, 1, 2, 5, 10, 20, 50, and 100 ppm (expressed as mg/L of CaCO3) and are selected by choosing the
appropriate model. Easy to read LED indicators show a simple “HARD” or “SOFT” sample status. You can also use SP510’s built-in alarm
relay to actuate an external annunciator.

Low maintenance requirements


The SP510 samples water every two minutes, operating automatically for up to 60 days. It is virtually maintenancefree, requiring only about 15
minutes every two months to replenish and standardise the reagents. Replace tubing in the pump system every six months.

Rugged, lightweight, and self-contained


The SP510 monitor makes your water softening system more eBcient and less costly. It eliminates the guesswork so your softener is
regenerated only when needed. Regeneration based on calculation or set times can be replaced with continuous monitoring and automatic
control, lowering reagent consumption.

Rugged, lightweight, and self-contained


The SP510 case is made of ABS plastic which is lightweight, corrosion-resistant, and shatterproof. This sealed case is IP62-rated and has a
hinged door for easy access to internal components.

Specifications
Accuracy: ±25% of set point value
Alarm: 2 consecutive cycles above set point activate alarm.

1 cycle below set point cancels alarm.

Alarm type: LED indicators, Hard or Soft


Alarm points: 1 mg/L of CaCO3 trip point
Certifications: NRTL certified to UL and CSA standards, and CE approved
Cycle Time: 2 average
Dimensions (H x W x D): 419 mm x 318 mm x 178 mm
Enclosure Rating: IP62
Fitting Type: Inlet: ¼-in. OD tube quick-disconnect fitting

Outlet: ½-in. ID flexible hose


Light Source: LED with peak wavelength of 610 nm
Maintenance Interval: Standardize and replenish reagents every 2 months using EDTA or high-level sample

Replace pump tubes every 6 months


Material Enclosures: ABS plastic, large plastic windows to view alarm and reagents level
Measurement Method: Colorimetric
Mounting: Wall mount
Operating Humidity: 5 - 95%, non-condensing
Operating Temperature Range: 5 - 40 °C
Output: 1 SPDT relay
Power Requirements (Hz): 50/60 Hz
Power Requirements (Voltage): 115/230 V AC
Reagent Consumption: 500 mL each indicator and buffer every two months
Repeatability: ±10% of set point value in 0.3 - 2 mg/L ranges;

± 4% of set point value in 5 - 100 mg/L ranges


Sample Flow Rate: 50 - 500 mL/min
Sample Pressure: 0.07 - 0.34 bar (0.10 bar is optimum)

Sample conditioning: 0.10 - 5.17 bar


Storage Conditions: -40 to 60 °C (-40 to 140 °F)
Weight: 11.3 kg

What's included?

SP510 Hardness Monitor, two month's supply of reagents, an installation kit, a maintenance kit, Hach user manual.

Product details pdf footer

You might also like