0% found this document useful (0 votes)
263 views5 pages

Mechanical Data Sheet For Rich Teg Carbon Filter (F-2003/3003), (F-2004/3004)

This document is a mechanical data sheet for a rich TEG carbon filter system with two main and two standby filters. It provides technical specifications for the filters such as dimensions, flow rates, pressure limits, temperatures, filtration efficiency, and characteristics of the TEG fluid being filtered. The data sheet also specifies compliance with various codes and standards for seismic loading, welding, and stamping.

Uploaded by

AbdulBasit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
263 views5 pages

Mechanical Data Sheet For Rich Teg Carbon Filter (F-2003/3003), (F-2004/3004)

This document is a mechanical data sheet for a rich TEG carbon filter system with two main and two standby filters. It provides technical specifications for the filters such as dimensions, flow rates, pressure limits, temperatures, filtration efficiency, and characteristics of the TEG fluid being filtered. The data sheet also specifies compliance with various codes and standards for seismic loading, welding, and stamping.

Uploaded by

AbdulBasit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

TATWEER PETROLEUM

FEED FOR NAG LTFD Phase ll


Mechanical Data Sheet for RICH TEG Carbon Filter
(F-2003/3003), (F-2004/3004)
Document No.: TP-CGDF-00001-DAS-A4-P0 Contract No.:
Page 1 Of 5
TDE Doc No.: TDE Rev.: P0

MECHANICAL DATA SHEET FOR RICH TEG CARBON


FILTER
(F-2003/3003), (F-2004/3004)

P0 Issued for Proposal ABT MSH SMB 6-Sep-2018

Rev. Description Prepared By Checked By Approved By Date


TATWEER PETROLEUM
FEED FOR NAG LTFD Phase ll
Mechanical Data Sheet for Rich TEG Carbon Filter
(F-2003/3003), (F-2004/3004)
Document No.: TP-CGDF-00001-DAS-A4-P0 Contract No.:
Page 2 Of 5
TDE Doc No.: TDE Rev.: P0

Tabulation Of Revised Pages


Page Page
1 36
2 37
3 38
4 39
5 40
6 41
7 42
8 43
9 44
10 45
11 46
12 47
13 48
14 49
15 50
16 51
17 52
18 53
19 54
20 55
21 56
22 57
23 58
24 59
25 60
26 61
27 62
28 63
29 64
30 65
31 66
32 67
33 68
34 69
35 70
TATWEER PETROLEUM
FEED FOR NAG LTFD Phase ll
Mechanical Data Sheet for Rich TEG Carbon Filter
(F-2003/3003), (F-2004/3004)
Document No.: TP-CGDF-00001-DAS-A4-P0 Contract No.:
Page 3 Of 5
TDE Doc No.: TDE Rev.: P0

Rev.
1 RICH TEG CARBON FILTER DATA SHEET
2 GENERAL DATA
3 ITEM: (F-2003/3003), (F-2004/3004) TYPE: Cartridge Carbon / Vertical (1)
4 SERVICE / SERVICE TYPE / FLUID: Rich TEG Carbon Filter / Lethal /Rich TEG (Note 2) Thickness (Head / Shell) mm 6 / 6 min (VTC)
5 NO. of main / Stand by 2 / 2 (1 / 1 for each train) Filtration Stages VTA
6 Radiography (Shell/Head) 100 / 100 Head type: Ellipitical 2:1
Joint Efficiency (Shell
7 1/1 PWHT / PFHT / Hydrotest (40) No / - / Yes
/ Head)
As per ASCE 7 & IBC
8 Wind Speed (Max / Avg) ft/s, Exposure 147 ( 3 Sec gust speed ) Seismic (International Building Code).
(Note 37)
ASCE 7-02, Section 6.5, Method 2, with Exposure
9 CODE: Category = C, Importance factor (I) = 1.15 and Gust ASME STAMP Yes
factor = 0.85 (Note 31)

10 OPERATING CONDITIONS
11 DIAMETER (ID): 3' - 3.2" ft-in VTC
12 S/S, VESSEL HEIGHT: 10' -1.5" ft-in VTC
13 INLET TOTAL FLOW: 43079 / 3271 lb/h
14 OPERATING TEMPERATURE SUMMER/WINTER 233.8 / 233.8 °F
15 OPERATING PRESSURE: SUMMER/WINTER 53.5 / 53.5 psig
16 DESIGN TEMPERATURE: MIN/MAX 32 / 250 °F
17 DESIGN PRESSURE: 145 psig
18 ALLOWABLE PRESSURE DROP (CLEAN/DIRTY): / 10 psi
19 FILTRATION EFFICIENCY: Removal of 99% of any particles with greater than diameter of 10 μm
20 MINIMUM CARTRIDGE CHANGEOVER TIME: 30 days
21 CHARACTERISTICS OF FLUID
22 CASE
23 MASS FLOW: lb/h 43079-3271
PROCESS DATA

24 MOLECULAR WEIGHT: - 100.60 -99.58


25 MASS DENSITY: lb/ft3 64.94-64.67 (Note 22)
26 VISCOSITY: cP 2.33-2.26
27 ACTUAL VOLUME FLOW: ft3 /h 663.5-50.58
28 NATURE OF SOLID: (Note 2,10)
MATERIAL TO BE
RETAINED

29 MINIMUM FILTERATION AREA: m2/m3 of TEG (Note 8)


30 SOLID DENSITY: (Note 10)
31 SOLID PARTICLE SIZE: (Note 10)
32 CO2 mol fraction 0.0025-0.0034
33 H2S mol fraction 0.00035-0.0008
34 METHANE mol fraction 0.0002-0.0001
36 i-Butane mol fraction 0.00012-0.0003
mol fraction
COMPOSITION

37 i-Pentane 0.00018-0.0006
38 n-Pentane mol fraction 0.00004-0.0001
39 Benzene mol fraction 0.0012-0.0041
40 Toluene mol fraction 0.0014-0.0045
41 m-Xylene mol fraction 0.0015-0.0027
42 E-Benzene mol fraction 0.0014-0.0026
43 H2O mol fraction 0.3700-0.3725
44 TE-GLYCOL mol fraction 0.6200-0.6081
45 CORROSIVE/EROSIVE/HAZARDOUS AGENTS: Yes / No / Yes (Toxic)
46 OTHER CONSIDERATIONS: Lethal Service (Note 9)
47 MECHANICAL DATA (Note 25) ( Note 31)

MATERIAL:
48 (24,25, 26) ASTM SA240 TP SS 316L EXTERNAL PAINTING: N/A
(External/Internals)

49 MATERIAL OF FILTERING MEDIUM: SS 316L VTC INTERNAL PAINTING: N/A


50 CORROSION ALLOWANCE: mm 0 INLET DISTRIBUTOR No
51 MIST ELIMINATOR / VORTEX BREAKER No / No Lifting Lug / Earthing Lug Yes / Yes (Note 32)
INSULATION / THICKNESS
52 LADDER PLATFORM No (VTC) /INSULATION SUPPORTS
PP / 40 / Yes

53 SKIRTS / LEGS / SADDLE Legs Stud Bolt & Nuts for Flange (Note 15)
54 BLIID FLANGE ASTM A182 F316L (Note 28) Gasket Spiral Wound (Note 13)
55 NOTES Continued
56 (1) Type of filter should be finalized by vendor
57 (2) Rich TEG may contain contaminations such as scale, well treating chemicals, compressor oil and other foam promoting compounds
58 (3) Specified data is considered as rated conditions which is 120% of normal flows.
59 (4) Turn down ratio to be conidered 20% of normal flow
60 (5) Summer case is same as winter case at rated conditions
61 (6) Clean, Dirty & collapse pressure drop of filter should be finalized by filter vendor.
62 (7) To be confirmed by vendor / Vendor to advice.
63 (8) Filteration area to be specified by vendor
64 (9) Max H2S & CO2 contents are 800 & 3400 ppm (mol %)
65 (10) Supplier to advise on filter loading/design based on experience on similar operations.
TATWEER PETROLEUM
FEED FOR NAG LTFD Phase ll
Mechanical Data Sheet for Rich TEG Carbon Filter
(F-2003/3003), (F-2004/3004)
Document No.: TP-CGDF-00001-DAS-A4-P0 Contract No.:
Page 4 Of 5
TDE Doc No.: TDE Rev.: P0

Rev.
1 RICH TEG CARBON FILTER DATA SHEET
2 LIST OF CONNECTIONS (Note 23) (Note 26) (Note 36)
3 SERVICE ITEM SIZE (IN) NO. RATING TYPE REMARKS
4 FEED INLET VTC 1 150# W.N.R.F.
5 TEG OUTLET VTC 1 150# W.N.R.F.
6 VENT VTC 1 150# W.N.R.F. (Note 20)
7 RELIEF VTC 1 150# W.N.R.F.
8 UTILITY CONNECTION VTC 1 150# W.N.R.F.
9 DRAIN VTC 1 150# W.N.R.F.
10

11

12

13

14 Estimated Weight
15 Fabricated Weight lb (VTC)
16 Additional Internal Weight lb (VTC)
17 Piping, Platforms, Ladders Weight lb (VTC)
18 Insulation Weight lb (VTC)
19 Operating Weight lb (VTC)
20 Test Liquid Weight lb (VTC)
21 Hydrotest weights lb (VTC)
22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39 NOTES Continued
40 (11) Vendor should guarantee filtration of inlet flow rate, max pressure drop, min retained particle size and filtration efficiency
41 (12) The facilities to change filter performance to large/smaller micron size is required based on operating experience
42 (13) Gasket: SPW, AISI 316L Winding/Inner & Outer Ring: AISI 316L, Graphite Filler, 150#, Rf, SRF, 4.50 Mm, ASME B16.20, NACE MR0175
43 (14) VTA: Vendor to advice

44 (15) Bolt & Nuts, Stud/Hev Hex, Ful thd, ASTM A193 Gr.B8m Cl.2/ASTM A194 Gr.8ma, ASME B18.2.1/ASME B18.2.2

45 (16) Design life is 25 years


46 (17) Process of this document should be investigated and guaranteed by vendor
47 (18) Size, number and arrangement of nozzles should be finalized by vendor
48 (19) Size of shell, size and number of elements, element clearance and pitch should be specified by vendor
49 (20) To be located at opposite side of inlet
TATWEER PETROLEUM
FEED FOR NAG LTFD Phase ll
Mechanical Data Sheet for Rich TEG Carbon Filter
(F-2003/3003), (F-2004/3004)
Document No.: TP-CGDF-00001-DAS-A4-P0 Contract No.:
Page 5 Of 5
TDE Doc No.: TDE Rev.: P0

Rev.
1 RICH TEG CARBON FILTER DATA SHEET
2 SKETCH
3

10

11

12

13

14

15

16

17

18

19

20

21

22
sketch to be supplied from vendor
23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40 NOTES Continued
41 (21) Nozzles size will be finalized after receving vendor data
42 (22) Combined phase density (lb/ft3) = 64.94, vapor = 0.285, liquid = 64.94
43 (23) Flanges:WN, Frgd, ASTM A182 Gr.F316L, 150#, RF, SRF, ASME B16.5, Nace Mr0175
44 (24) The design of nozzle shall be considered "MAWP+Static Head to nozzle"
45 (25) All material shall comply with NACE MRO 175/ISO 15156.
46 (26) Hydrotest type shall be as per UG-99b vessel shall be designed for hydrotest in corroded condition.
47 (27) Deleted
48 (28) A182 F316L
49 (29) Details will be finalized in material selection diagram.
50 (30) Type of opening considered by vendor.
51 (31) CODE: ASCE 7-02, Section 6.5, Method 2, with Exposure Category = C, Importance factor (I) = 1.15 and Gust factor = 0.85
52 (32) All filters generate static electricity, which need grounding (LEGS)
53 (33) To be specified / finalized by vendor.
54 (34) With Blind Flange, Davit, Gasket, Bolt & Nuts.
55 (35) Blind Flange: ASTM A182 GR.F316l, 150#, Rf, Srf, Asme B16.5, Nace Mr0175
56 (36) Schedule to be as per Piping Material Specifications "FEC-019 Piping Material Specifcations "

Seismic Calculation shall be performed as per ASCE 7 & IBC (International Building Code).
Criteria to be considered in earthquake design are given below:
57 (37)
Earthquake Criteria
Short Period Acceleration (Ss) in %g 8.3
1-Sec Period Acceleration (S1) in %g 2.8
Site Classification D