Datasheet

Juniper Networks EX 4200


Ethernet Switches with
Virtual Chassis Technology
Product Description
The Juniper Networks EX 4200 series Ethernet switches with Virtual Chassis technology
combine the High Availability (HA) and carrier-class reliability of modular systems with
the economics and flexibility of stackable platforms, delivering a high-performance,
scalable solution for data center, campus and branch office environments.

Offering a full suite of Layer 2 and Layer 3 switching capabilities as part of the
base software, the EX 4200 series switches satisfy a variety of high-performance
applications, including branch, campus and data center access deployments as well as
High-performance businesses demand high- Gigabit Ethernet (GbE) aggregation deployments. A single 24-port or 48-port switch can
be deployed initially; as requirements grow, Juniper Virtual Chassis technology allows
performance networking solutions. These up to 10 EX 4200 series switches to be interconnected over a 128 Gigabit-per-second
(Gbps) backplane and managed as a single device, delivering a scalable, pay-as-you-
solutions include a new class of secure,
grow solution for expanding network environments. Flexible Gigabit Ethernet (GbE)
scalable and always-on enterprise switch and 10 Gigabit Ethernet (10GbE) uplink options enable high-speed connectivity to
aggregation- or core-layer switches which connect multiple floors or buildings.
that advances the economics of networking
All EX 4200 series switches include HA features such as redundant, hot-swappable
by enabling businesses to deploy innovative internal power supplies and field-replaceable, multi-blower fan trays to ensure maximum
new technologies that increase revenue and uptime. In addition, the base EX 4200 series switch models offer Class 3 power over
Ethernet (PoE), delivering 15.4 watts on the first eight ports to support IP-enabled devices
improve productivity. The Juniper Networks such as telephones, video cameras and wireless LAN (WLAN) access points for low-
density converged networks. Full PoE options delivering 15.4 watts on all 24 or 48 ports
EX 4200 series Ethernet switches with Virtual are also available, making them ideal for high-density IP telephony deployments.
Chassis™ technology combine the compact, Each EX 4200 series switch includes an integrated application-specific integrated circuit
pay-as-you-grow economics and low power and (ASIC)-based packet-forwarding engine, the EX-PFE, while an integrated Route Engine
(RE) delivers all control plane functionality. Based on field-proven Juniper technology,
cooling requirements of stackable switches the Route Engine brings the same level of carrier-class performance and reliability to
the EX 4200 series switches that Juniper routers bring to the world’s largest service
with the performance, availability, operational
provider networks.
ease and port densities of chassis-based
The EX 4200 series switches also leverage the same modular JUNOS™ software as
platforms to meet the demands of today’s Juniper router products, ensuring a consistent implementation and operation of each
control plane feature across an entire Juniper infrastructure.
high-performance enterprises.

Juniper Networks Virtual Chassis Technology:


Chassis-like Switch Features in a Stackable Form Factor
• Redundant, internal hot-swappable power supplies
• Hot-swappable fan tray with redundant blowers
• Consistent modular JUNOS software control plane feature implementation
• Dual Route Engines with Graceful Route Engine Switchover (GRES), non-stop
routing (NSR*) and non-stop bridging (NSB*)
• Single management interface
• Easy, centralized software upgrades
• Scales from 24 to 480 ports with up to 20 10GbE uplinks

* Roadmap
2

Architecture and Key Components Features and Benefits


The EX 4200 series switches are single rack-unit devices that Chassis-Class Availability
deliver a compact solution for crowded wiring closets and access
switch locations where space and power are at a premium. The EX 4200 series Ethernet switches deliver the same HA
Each EX 4200 series switch supports optional front-panel uplink functionality and support many of the same failover capabilities as
modules offering either four GbE ports or two 10GbE ports for other Juniper chassis-based systems.
high-speed backbone or link-aggregation connections between Each EX 4200 series switch is capable of functioning as a
wiring closets and upstream aggregation switches. Uplink modules Route Engine. When two or more EX 4200 series switches are
can be installed without powering down the switch, enabling users interconnected, they share a single control plane among all virtual-
to add high-speed connectivity at any time or migrate from one chassis member switches. When two EX 4200 series switches
uplink type to the other to deliver the ultimate in flexible, high- are interconnected, the JUNOS software automatically initiates
performance interconnectivity. an election process to assign a master (active) and backup (hot-
standby) Route Engine. An integrated Layer 2 and Layer 3 Graceful
EX 4 EX 4
Route Engine Switchover (GRES) feature maintains uninterrupted
200 200
SEe
Xri4e2s
Serie
E X4s
00
SEe
Xri4e2s
Serie
E X4s
00 access to applications, services and IP communications in the
Serie200 Serie200 Single
s s
Virtual unlikely event of a primary RE failure.
Acce
Pointss
Acce
Pointss
Chassis
System When more than two switches are interconnected in a virtual-
West Closet East Closet
chassis configuration, the remaining switch elements act as line
cards and are available to assume the backup RE position should
Floor N the designated master fail. Master, backup and line-card priority
Figure 1: Using Virtual Chassis technology, up to 10 EX 4200 series status can be assigned by the network operations team to dictate
switches can be interconnected to create a single logical device spanning the order of ascension; this N+1 RE redundancy, coupled with
multiple wiring closets, floors or even buildings. the GRES, non-stop routing (NSR) and non-stop bridging (NSB)
capabilities of the JUNOS software, assures a smooth transfer of
The EX 4200 series switches also feature a front-panel LCD display control plane functions following unexpected failures.
that offers a flexible interface for performing device bring-up and
configuration rollbacks, reporting switch alarm and LED status, or The EX 4200 series switches implement the same slot/module/
restoring the switch to its default settings. The LCD also displays a port numbering schema as other Juniper chassis-based products
virtual chassis member switch’s chassis “slot number” and Route when numbering virtual-chassis ports, providing true chassis-like
Engine status for rapid identification and problem resolution. operations. By utilizing a consistent operating system and a single
configuration file, all switches in a virtual-chassis configuration are
Dual rear-panel virtual-chassis ports enable EX 4200 series switches treated as a single device, simplifying overall system maintenance
to be interconnected over the 128 Gbps virtual backplane. Switches and management.
deployed in close proximity, such as wiring closets or top-of-rack
data center applications, can be connected using a Juniper-supplied Individually, the EX 4200 series switches offer a number of HA
virtual-chassis cable. features that are typically associated with modular chassis-based
switches. When combined with the field-proven JUNOS software and
In addition, a dedicated rear-panel RJ-45 port is available for out- L2/L3 failover capabilities, these features provide the EX 4200 series
of-band management, while a rear-panel USB port can be used to switches with true carrier-class reliability.
easily upload JUNOS software and configuration files.
EX 4
Master RE Serie200 Graceful Route
s
Virtual Chassis Technology Engine Switchover
EX 4 (GRES) for hitless
Backup RE Serie200
s failovers
Up to 10 EX 4200 series switches can be interconnected using Virtual
Chassis technology to create a single logical device supporting up EX 4
Serie200
s
to 480 10/100/1000BASE-T ports or 240 100BASE-FX/1000BASE-X
EX 4
ports, plus an additional 40 GbE or 20 10GbE uplink ports. Different Serie200
s
models can be mixed in a virtual-chassis configuration to provide a
EX 4
variety of port and density options. Serie200
s

In a virtual-chassis configuration, all switches are monitored and


managed as a single device, enabling enterprises to separate
Figure 2: Support for Graceful Route Engine Switchover (GRES) ensures
physical topology from logical groupings of endpoints and allowing
a smooth and seamless transfer of control plane functions following a
more efficient resource utilization. Highly resilient topologies can
master Route Engine failure.
also be created using the 10GbE uplink ports to extend the virtual
chassis configuration across long distances spanning multiple
wiring closets, floors or even buildings.
3

• Redundant power supplies: The EX 4200 series Ethernet Converged Networks


switches support internal redundant, load-sharing, hot-swappable
AC power supplies to maintain uninterrupted operations. Thanks The EX 4200 series Ethernet switches provide the highest levels
to their compact footprint, the EX 4200 series switches require of availability for the most demanding converged data, voice and
significantly less power than chassis-based switches delivering video environments, delivering the most reliable platform for
equivalent port densities. unifying enterprise communications.
• Hot-swappable fan tray with multiple blowers: The EX 4200 By providing Class 3 PoE with 15.4 watts on some or all ports
series switches include a hot-swappable, field-replaceable fan tray to power voice over IP (VoIP) telephones, closed-circuit security
with three blowers, providing sufficient cooling even if one of the cameras, wireless access points, and other IP-enabled devices,
blowers were to fail. the EX 4200 series switches deliver a future-proofed solution for
• Redundant Trunk Group (RTG): To avoid the complexities of converging disparate networks onto a single IP infrastructure.
the Spanning Tree Protocol (STP) without sacrificing network To ease deployment, the EX 4200 series switches support the
resiliency, the EX 4200 series switches employ redundant trunk industry-standard link-layer discovery protocol (LLDP) and LLDP-
group to provide the necessary port redundancy and simplify Media Endpoint Detection (LLDP-MED), which enable the switches
switch configuration. to automatically discover Ethernet-enabled devices, determine their
• Cross-member link aggregation: Cross-member link aggregation power requirements and assign virtual LAN (VLAN) parameters.
allows redundant link aggregation connections between devices
in a single virtual-chassis configuration, providing an additional In addition, the EX 4200 series switches support rich quality
level of reliability and availability. of service (QoS) functionality for prioritizing data, voice and
video traffic. The switches support eight QoS queues on every
• Carrier-class hardware: The EX 4200 series switches leverage a port, enabling them to maintain multi-level, end-to-end traffic
purpose-built packet forwarding engine ASIC, the EX-PFE, which prioritizations. The EX 4200 series switches also support a wide
integrates much of the same intellectual property used in Juniper range of policy options, including priority and shaped deficit
Networks carrier routers. As a result, the EX 4200 series switches weighted round-robin (SDWRR) queuing.
deliver the same predictable, scalable functionality found in the
world’s largest networks. Security
Carrier-Class Operating System The EX 4200 series Ethernet switches fully integrate with the
Juniper Networks Unified Access Control (UAC) solution, which
The EX 4200 series switches run the same JUNOS operating system consolidates all aspects of a user’s identity, device and location,
software used by Juniper routers to power the world’s largest and enabling administrators to enforce access control and security
most complex networks. down to the individual port or user levels.
By utilizing a common operating system, Juniper delivers a
Policy Manager Infr AAA
Contr anet
consistent implementation and operation of control-plane features oller Steel-B
elt
Radius ed

across all products. To maintain that consistency, the JUNOS


software adheres to a highly disciplined development process that
utilizes a single source code, follows a single quarterly release train,
and employs a highly available modular architecture that prevents
isolated failures from bringing an entire system down.
EX 4 $PSQ
Serie200 NetwPSBUF
FW/
VPN
s ork
These attributes are fundamental to the core value of the software,
enabling all JUNOS-powered products to be updated simultaneously UAC Agent Firewall
t"DDFTTHSBOUFE
with the same software release. All features are fully regression- t7-"/BTTJHOFE Enforcer Protected
t2P4QPMJDJFTBQQMJFE Servers
tested, making each new release a true superset of the previous
version; customers can deploy the software with complete
confidence that all existing capabilities will be maintained and Figure 4: The EX 4200 series switches work with the Juniper UAC solution
operate in the same way. to enforce access control down to the individual port level.

TX
Working as an enforcement point within the UAC solution, the EX
4200 series switches provide both standards-based 802.1X port-
Matri
x

J-ser
ies 8.5 9.0 9.1 level access control as well as Layer 2-4 policy enforcement based
— API —

Module
Q407 Q108 Q208
X on user identity, location and/or device. A user’s identity, device
type, machine posture check and location can be used to determine
One OS One Release One Architecture
whether access should be granted and for how long. If access is
Figure 3: The JUNOS software utilizes a single source code, adheres granted, the switch assigns the user to a specific VLAN based on
to a consistent and predictable release train, and employs a single authorization levels. The switch can also apply QoS policies or
modular architecture. mirror user traffic to a central location for logging, monitoring or
threat detection by intrusion prevention systems.
4

The EX 4200 series switches also provide a full complement of EX 4200 Series Ethernet Switch Specifications
port security features including DHCP (Dynamic Host Configuration
Protocol) snooping, DAI (Dynamic ARP Inspection), MAC limiting Physical Specifications
and IP Source Guard to defend against internal and external • 24-port copper switches:
spoofing, man-in-the-middle and denial of service (DoS) attacks.
– 24 10/100/1000BASE-T ports: 8 PoE (802.3af compliant)@
Simplified Management and Operations 15.4 W; 320 W PSU
– 24 10/100/1000BASE-T ports: 24 PoE (802.3af compliant)@
When employing Virtual Chassis technology, the EX 4200 series 15.4 W; 600 W PSU
switches dramatically simplify network management. Up to 10 • 48-port copper switches:
interconnected EX 4200 series switches can be managed as a
– 48 10/100/1000BASE-T ports: 8 PoE (802.3af compliant)@
single device. Each virtual chassis group utilizes a single JUNOS
15.4 W; 320 W PSU
software image file and a single configuration file, reducing the
overall number of units to monitor and manage. When the JUNOS – 48 10/100/1000BASE-T ports: 48 PoE (802.3af compliant)@
software is upgraded on the master switch in a virtual-chassis 15.4 W; 930 W PSU
configuration, the software is automatically upgraded on all other • 24-port fiber switches:
member switches at the same time. – 24 100BASE-FX/1000BASE-X SFP ports; 320 W PSU
• Backplane: 128 Gbps virtual-chassis interconnect to combine up
The EX 4200 series switches also include port profiles that allow to 10 units as a virtual chassis
network administrators to automatically configure ports with
• Uplink module options:
security, QoS and other parameters based on the type of device
connected to the port. Six preconfigured profiles are available, – 4-port 1GbE module with pluggable SFP optics
including default, desktop, desktop plus IP phone, wireless access – 2-port 10GbE module with pluggable XFP optics
point, routed uplink and Layer 2 uplink. Users can select from the Power Options
existing profiles or create their own and apply them through the • Power supplies: Autosensing; 100-120 V / 200-240 V;
Command Line Interface (CLI) or management system. AC 320 W, 600 W and 930 W dual load-sharing hot-swappable
Four system management options are available for the EX 4200 internal redundant power supplies
series switches. The standard JUNOS software CLI management • External RPS option
interface offers the same granular capabilities and scripting • Minimum number of PSUs required for fully loaded chassis:
parameters found in any JUNOS software powered device. 1 per switch
The EX 4200 series switches also include the integrated J-Web Dimensions (W x H x D)
management tool, an embedded device manager that allows
17.41 x 1.72 x 16.43 in
users to configure, monitor, troubleshoot and perform system
(44.21 x 4.32 x 41.73 cm)
maintenance on individual switches via a browser-based graphical
interface.
1
Desktop installation width noted above, rack-mount width is 17.5
in (44.5 cm)
When managing a group of EX 4200 series switches, the Juniper 2
Height: 1 RU
NetScreen-Security Manager (NSM) provides system-level 3
Depth with 320 W PSU noted above, 18.8 in (47.8 cm) with
management across all Juniper switches in the network, from a 600/930 W PSU
single console.
Weight
Finally, EX 4200 series switch system, performance and fault data • EX 4200-24T with 320 W PSU: 16.5 lb (7.5 kg)
can be exported to leading third-party management systems such • EX 4200-24P with 600 W PSU: 17.2 lb (7.8 kg)
as HP OpenView, IBM Tivoli and Computer Associates Unicenter, to
• EX 4200-48T with 320 W PSU: 17.1 lb (7.8 kg)
provide a complete, consolidated view of network operations.
• EX 4200-48P with 930 W PSU: 18.2 lb (8.3 kg)
Product Options • EX 4200-24F with 320 W PSU: 16.1 lb (7.3 kg)
Five EX 4200 series switch models are available (see Table 1 below). Environmental Ranges
Table 1: EX 4200 Series Ethernet Switches • Operating temperature: 32° to 113° F (0º to 45ºC)
• Storage temperature: -40º to 158º F (-40º to 70º C)
Model Access Port Configuration PoE Height System
Ports Power • Operating altitude: up to 10,000 ft (3,049 m)
(with • Non-operating altitude: up to 16,000 ft (4,877 m)
PoE)
• Relative humidity operating: 10% to 85% (noncondensing)
EX 4200-24T 24-port 10/100/1000BASE-T 8 1RU 320 W AC
• Relative humidity non-operating: 0% to 95% (noncondensing)
EX 4200-24P 24-port 10/100/1000BASE-T 24 1RU 600 W AC
Cooling
EX 4200-24F 24-port 100BASE-FX/1000BASE-X (SFP) N/A 1RU 320 W AC
• Field-replaceable fan tray with multiple blowers (3)
EX 4200-48T 48-port 10/100/1000BASE-T 8 1RU 320 W AC
• Switch remains operational if one blower fails
EX 4200-48P 48-port 10/100/1000BASE-T 48 1RU 930 W AC
5

Hardware Specifications Layer 2 Switching (cont’d)


• Switching Engine Model: Store and forward • MST (802.1D-2004)
• DRAM – 1 GB with ECC • Number of 802.1s instances supported: 64
• Flash – 1 GB • LLDP
• CPU – 1 GHz PowerPC CPU • LLDP-MED with VoIP integration
• 10/100/1000BASE-T connector type: RJ-45 • RVI (Routed VLAN Interface)
• GbE SFP optic/connector type: RJ-45 or LC SFP fiber
Layer 3 Features: IPv4
supporting 1000BASE-T SFP, SX (multimode), LX (single-mode)
or ZX (single-mode) • Max number of ARP entries: 16,000
• 100BASE-FX support on SFP ports: SX • Max number of IPv4 unicast routes in hardware: 12,000
• GbE port density per system: • Max number of IPv4 multicast routes in hardware: 2,000
– 24P/24T/24F: 28 (24 host ports + four-port GbE uplink • Routing protocols: RIPv1/v2, OSPF, BGP, ISIS
module) • Static routing
– 48P/48T: 52 (48 host ports + four-port GbE uplink module) • Routing policy
• 10GbE XFP optic/connector type: 10GE XFP, SR (multimode), • Bidirectional Forwarding Detection
LR (single-mode), ER (single-mode) or ZR (single-mode) • Layer 3 redundancy: VRRP
• 10GbE port density per system (all models): 2 (uplink module)
• IPv6, MPLS and GRE tunnel hardware support* Security

Physical Layer • MAC limiting


• Allowed MAC addresses – configurable per port
• Time Domain Reflectometry (TDR) for detecting cable breaks • Dynamic ARP Inspection (DAI)
and shorts: 24P/24T and 48P/48T only
• Local proxy ARP
• Auto MDI/MDIX support: 24P/24T and 48P/48T only (all ports)
• Static ARP support
• Port speed downshift/setting max advertised speed on
• DHCP snooping
10/100/1000BASE-T ports: 24P/24T and 48P/48T only, on all
ports Access Control Lists (ACLs) (JUNOS firewall filters)
• Port-based ACL (PACL) – Ingress
Packet Switching Capacities
• VLAN-based ACL (VACL) – Ingress and Egress
• 24P/24T: 88 Gbps • Router-based ACL (RACL) – Ingress and Egress
• 48P/48T: 136 Gbps • ACL entries (ACE) in hardware per system: 7,000
• 24F: 88 Gbps • ACL counter for denied packets
• ACL counter for permitted packets
Layer 2 Throughput (Mpps)
• Ability to add/remove/change ACL entries in middle of list
• 24P/24T: 65 Mpps (wire speed) (ACL editing)
• 48P/48T: 101 Mpps (wire speed) • Layer 2 – L4 ACL
• 24F: 65 Mpps (wire speed) • 802.1X port-based
• 802.1X multiple supplicants
Layer 2 Switching
• 802.1X with VLAN assignment
• Max MAC addresses per system: 24,000 • 802.1X with authentication bypass access (based on host MAC
• Static MAC entries: 24,000 address)
• Jumbo frames: 9216 Bytes • 802.1X with VoIP VLAN support
• Number of VLANs: 4,096 • 802.1X dynamic ACL based on RADIUS attributes
• Port-based VLAN • 802.1X Supported EAP types: MD5, TLS, TTLS, PEAP
• MAC-based VLAN • MAC Authentication (local)
• GVRP • Control Plane DoS protection
• VLAN tagging: 802.1Q
High Availability
• Voice VLAN
• Physical port redundancy: Redundant trunk group (RTG) • Redundant, hot-swappable power supplies
• STP (802.1D-2004) • Redundant, field-replaceable, hot-swappable fans
• Compatible with PVST+ • Graceful Route Engine Switchover (GRES) for Layer 2 hitless
• STP enable/disable per port forwarding and Layer 3 protocols on RE failover
• Rapid-Spanning Tree (802.1D-2004) • Graceful protocol restart – OSPF, BGP
• Layer 2 hitless forwarding on RE failover
• Online insertion and removal (OIR) uplink module
* Software roadmap
6

Link Aggregation Services and Manageability (cont’d)


• 802.3ad (LACP) support: • NTP
– Number of LAG groups supported: 64 • DHCP server
– Max number of ports per LAG group: 8 • DHCP client and DHCP proxy
• LAG load-sharing algorithm – Bridged Unicast Traffic: • DHCP relay and helper
– IP: S/D MAC, S/D IP • RADIUS
– TCP/UDP: S/D MAC, S/D IP, S/D Port • TACACS+
– Non-IP: S/D MAC
• SSHv2
• LAG-sharing algorithm – Routed Unicast Traffic:
• Secure copy
– IP: S/D MAC, S/D IP
• HTTP/HTTPs
– TCP/UDP: S/D MAC, S/D IP, S/D Port
• DNS resolver
– Non-IP: S/D MAC
• LAG load-sharing algorithm – Bridged Multicast Traffic: • Syslog logging
– IP: S/D MAC, S/D IP • Temperature sensor
– TCP/UDP: S/D MAC, S/D IP, S/D Port • Config-backup via FTP / secure copy
– Non-IP: S/D MAC Troubleshooting
• LAG-sharing algorithm – Routed Multicast Traffic:
– IP: S/D MAC, S/D IP • Debugging: CLI via console, telnet or SSH
– TCP/UDP: S/D MAC, S/D IP, S/D Port • Diagnostics: Show and debug cmd, statistics
– Non-IP: S/D MAC • Traffic mirroring (port)
• Tagged ports support in LAG group • Traffic mirroring (VLAN)
• ACL-based mirroring
QoS
• Mirroring destination ports per system: 1
• Layer 2 QoS • LAG port monitoring
• Layer 3 QoS • Multiple destination ports monitored to 1 mirror (N:1)
• Ingress policing: 1 rate 2 color • Max number of mirroring sessions: 1
• Hardware queues per port: 8
• Mirroring to remote destination (over L2): 1 destination VLAN
• Scheduling methods (egress): Strict priority (SP), Shaped Deficit
• IP tools: Extended ping & trace
Weighted Round-Robin (SDWRR)
• Juniper commit and rollback
• 802.1p, DSCP/IP Precedence trust and marking
• Layer 2-4 classification criteria: Interface, MAC address, Safety and Compliance
Ethertype, 802.1p, VLAN, IP address, DSCP/IP Precedence,
TCP/UDP port numbers, etc. Safety Certifications
• Congestion avoidance capabilities: Tail Drop • UL-UL60950-1(First Edition)
• C-UL to CAN/CSA 22.2 No.60950-1(First Edition)
Multicast
• TUV/GS to EN 60950-1, Amendment A1-A4, A11
• IGMP: v1, v2, v3* • CB-IEC60950-1, all country deviations
• IGMP snooping*
Electromagnetic Compatibility Certifications
• PIM-SM
• IPv4 Multicast hardware entries: 2,000 • FCC 47CFR Part 15 Class A
• EN 55022 Class A
Services and Manageability • ICES-003 Class A
• JUNOS CLI • VCCI Class A
• Web interface • AS/NZS CISPR 22 Class A
• Out-of-band management: Serial; 10/100/1000BASE-T Ethernet • CISPR 22 Class A
• ASCII configuration • EN 55024
• Rescue configuration • EN 300386
• Configuration rollback • CE
• Image rollback Environmental
• LCD management
Reduction of Hazardous Substances (ROHS) 5
• Element management tools: NetScreen-Security Manager (NSM)
• Proactive services support via Advanced Insight Solutions (AIS) Noise Specifications
• SNMP: v1, v2c, v3 • Office Product Spec: 48dBA at 30°C (refer to ISO 7779)
• RMON (RFC 2819) Groups 1, 2, 3, 9 Telco
• CLEI code
* Roadmap
7

Ordering Information
Model Number Description
Switches and Software Licences
EX 4200-24T 24-port 10/100/1000BASE-T (8 PoE ports) –
320 W AC PSU
EX 4200-24P 24-port 10/100/1000BASE-T (24 PoE ports) –
600 W AC PSU
EX 4200-48T 48-port 10/100/1000BASE-T (8 PoE ports) –
320 W AC PSU
EX 4200-48P 48-port 10/100/1000BASE-T (48 PoE ports) –
930 W AC PSU
EX 4200-24F 24-port 100BASE-FX/1000BASE-X SFP –
320 W AC PSU
EX-24-AFL* Advanced Feature License for EX 4200-24T,
EX 4200-24P, EX 4200-24F switches
EX-48-AFL* Advanced Feature License for EX 4200-48T and
EX 4200-48P switches
Uplink Modules
EX-UM-2XFP 2-port 10GbE XFP Uplink Module
EX-UM-4SFP 4-port GbE SFP Uplink Module
Power Supplies**
EX-PWR-320-AC 320 W AC Power Supply Unit (PSU)
EX-PWR-600-AC 600 W AC Power Supply Unit (PSU)
EX-PWR-930-AC 930 W AC Power Supply Unit (PSU)
Pluggable Optics
EX-SFP-1GE-SX SFP, GbE, 850nm, 550m Reach, SX, With DDM
EX-SFP-1GE-LX SFP, GbE, 1310nm, 10km Reach, LX, With DD
EX-SFP-1GE-LH SFP, GbE, 1550nm, 70km Reach, LH (ZX), With
DDM
EX-SFP-1GE-T 740-013111 is the 1000BASE-T only SFP
EX-SFP-1FE-FX SFP, 100BASE-FX SGMII SFP 1310nm, 2K
EX-XFP-10GE-SR XFP, 10GE-SR, 850nm, 300m Reach,
EX-XFP-10GE-LR XFP, 10GE-LR / OC-192-SR1, 1310nm, 10Km
Reach, Multi Rate
EX-XFP-10GE-ER XFP, 10GE-ER / OC-192-IR2, 1550nm, 40Km
Reach, Multi Rate
EX-XFP-10GE-ZR XFP, 10GE-ZR / OC-192-LR2, 1550nm, 80Km
Reach, Multi Rate

* AFL includes licenses for IS-IS and BGP.

**Each switch comes with one power supply; power supply SKUs are for sparing or
ordering internal redundant power supplies.
About Juniper Networks
Juniper Networks, Inc. is the leader in high-performance networking. Juniper offers a high-performance network infrastructure that
creates a responsive and trusted environment for accelerating the deployment of services and applications over a single network.
This fuels high-performance businesses. Additional information can be found at [Link].

CORPORATE HEADQUARTERS EUROPE, MIDDLE EAST, AFRICA EAST COAST OFFICE ASIA PACIFIC REGIONAL SALES HEADQUARTERS
AND SALES HEADQUARTERS FOR REGIONAL SALES HEADQUARTERS Juniper Networks, Inc. Juniper Networks (Hong Kong) Ltd.
NORTH AND SOUTH AMERICA Juniper Networks (UK) Limited 10 Technology Park Drive 26/F, Cityplaza One
Juniper Networks, Inc. Building 1 Westford, MA 01886-3146 USA 1111 King’s Road
1194 North Mathilda Avenue Aviator Park Phone: 978.589.5800 Taikoo Shing, Hong Kong
Sunnyvale, CA 94089 USA Station Road Fax: 978.589.0800 Phone: 852.2332.3636
Phone: [Link] (888.586.4737) Addlestone Fax: 852.2574.7803
or 408.745.2000 Surrey, KT15 2PG, U.K.
Fax: 408.745.2100 Phone: 44.(0).1372.385500
[Link] Fax: 44.(0).1372.385501

Copyright 2008 Juniper Networks, Inc. All rights reserved. Juniper Networks, the Juniper
Networks logo, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc.
in the United States and other countries. JUNOS and JUNOSe are trademarks of Juniper To purchase Juniper Networks solutions, please
Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service
marks are the property of their respective owners. Juniper Networks assumes no responsibility contact your Juniper Networks sales representative
for any inaccuracies in this document. Juniper Networks reserves the right to change, modify,
transfer, or otherwise revise this publication without notice.
at 1-866-298-6428 or authorized reseller.
100215-001 Jan 2008

You might also like