12/30/2020 18BTE414T Biomaterials in Tissue Engineering
18BTE414T Biomaterials in Tissue
Engineering
The respondent's email address (dp5267@[Link]) was recorded on submission of
this form.
-------- cell lines are used in in-vitro testing of biomaterials *
L-929
L-926
L-925
L-928
Which of the following is the example of natural polymer? *
polyvinylchloride
Polymethyl methacrylate
Chondroitin sulphate
Polyurethanes
[Link] 1/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
In ------ year bone plates used to fix fractures. *
1950
1930
1900
1970
Option 5
------- type of biomaterial is used in cancer therapy *
foams
sheets
spherical
fibres
------ animal model is used for sensitization test *
Rat
Mice
Guinea pig
Rabbit
[Link] 2/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
Which of the following is the signature of biocompatibility? *
Corrosion of metals
irritation
intact cell membrane
thrombosis
In stainless steel ----------- percentage of chromium is added to prevent
corrosion *
8.5
7.5
9.5
10.5
The Nickel-Titanium alloy is otherwise called *
Kitinol
Titinol
Nitinol
Ritinol
[Link] 3/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
-------- is not a cellular effects during hemocompatability *
activation of the complement
inflammation
thrombosis
embolism
The tubular biomaterial is related to *
antimicrobial implants
antithrombogenic implants
cell-biomaterial interaction
nerve guides
Find out the advantage of in-vivo testing of biomaterials? *
Transgenic cells carrying human genes can be used
Relatively simple
higher level of significance
Experimentally controllable and reapeatable
[Link] 4/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
----------- is not a property of in-vitro testing of biomaterials *
good as the first step
rapid
better approximation to human environment
inexpensive
After biomaterial exposure to animal model, chromosomal aberration is related
to *
genotoxicity
systemic toxicity
implantation
subchronic toxicity
In order to improve corrosion resistance ----------- elements were alloyed with
magnesium *
Al-Cu-Mn
Al-Ti-Mn
Al-Co-Mn
Al-Zn-Mn
[Link] 5/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
-------- are the sources of toxic materials *
Option 6
Option 5
plasticizers
peptides
cotton seed oil
gelatin
Option 7
In biomaterial testing ‘sterlity” is related to *
Routine testing
Material biocompatibility
Raw material characterization
product and process validation
Which of the following ceramics are naturally derived? *
polycrystalline
graphite
Kaolinite
calcium silicates
[Link] 6/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
The radiographic marker is related to *
Magnesium alloy
Tantalum alloys
Cobalt alloys
Titanium alloy
Identify the experiment, which is not suitable for in-vitro testing of biomaterials *
Direct contact
indirect contact
Elution
agar diffusion
The most used titanium alloy in knee implants is *
Ti-6Al-4V
Ti-7Al-5V
Ti-5Al-3V
Ti-4Al-2V
[Link] 7/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
Which of the following is the bioactive ceramics? *
Zirconia
tricalcium phosphate
pyrolytov
hdroxyapatite
The polymeric fibres “Spandex” is otherwise called *
aramides
polyesters
polyurethane
nylon
----------- enzyme is used to dissect tissues for in-vitro cell culture *
amylase
pepsin
trypsin
rennin
[Link] 8/9
12/30/2020 18BTE414T Biomaterials in Tissue Engineering
The ISO 10,993-6 is related to *
test for systemic toxicity
sample preparation and reference materials
tests for cytotoxicity-in-vitro methods
test for local effects after implantation
------- biomaterial company is involved in design, manufacture and distribution
of orthopaedics *
Zimmer
Baxer International
Carmeda
SurModics
This form was created inside of SRM Institute of Science and Technology.
Forms
[Link] 9/9