Apostolos Mpantis Geologist Msc Geological and Geotechnical investigations and studies
Koumoundourou 18 p.o 42100 Trikala Greece
Project P.V PLOESTI
LOCATION : LUKOIL PLOIESTI ROMANIA
ΣΤΑΤΙΚΗ ΓΟΚΙΜΗ ΔΞΟΛΚΔΥΣΗΣ ΗΛΟΥ ΠΟΥ ΥΠΟΒΑΛΛΔΤΑΙ ΣΔ ΑΞΟΝΙΚΗ ΓΥΝΑΜΗ ΔΦΔΛΚΥΣΜΟΥ, NF P94-242-1
REINFORCEMENT OF SOILS BY INCLUSION - NAIL PULL OUT - TEST WITH CONSTANT RATE DISPLACEMENT
DATE : 15_01_2014 No:4
START TIME : 14:50 coordinates φ = 4456'71'' λ= 264'117''
DURATION : 5 Min
NAME : Apostolos Mpantis Dimitrios Gogos length under soil friction: 1,4m
Μετρήσεις
Νο h Nt
- mm kN
1 0,00 0,00
2 0,25 22,40
3 0,50 27,20
4 0,75 31,65
5 1,00 31,65
6 1,25 31,65
7 1,50 31,65
8 1,75 31,65
9 2,00 31,65
10 2,25 31,65
11 2,50 31,00
12 2,75 31,20
13 3,00 31,65
14 3,25 31,65
15 3,50 31,65
16 3,75 31,65
17 4,00 31,20
18 4,25 31,65
19 4,50 31,65
20 4,75 31,65
21 5,00 30,90
22 5,50 31,65
23 6,00 31,65
24 6,50 31,65
25 7,00 31,65
26 7,50 31,65 10% D
Type of pile : Χαλύβδινος κοχλιωτός πάσσαλος της Krinner D: 76,1 mm
Τύπου KSF PV M24 / PV T 76 x 1600 Fcd max : 22,1 kN
Ftd max : 22,0 kN
Fhd max: 10,8 kN
Movement Head Y (mm)
0 5 10 15 20 25 30
50,0
40,0
Tension Force Nt (kN)
30,0
20,0
10,0
0,0
Nt max = Rt = 31,65 kN RESULTS
h (Rt) = 7,50 mm
Eu = Nt/h = 4.220,00 kN/m