ULTRASONIC flow meters
UltraFlow 2500
Working Principle:
The working principle of a Ultrasonic flow meter is based on the transit-time Technology.
The ultrasonic flow meter utilizes two ultrasonic transducers that function as both
ultrasonic transmitter and receiver. The ultrasonic flow meter operates by alternately
transmitting and receiving a burst of ultrasound between the two transducers by measuring
the transit time that it takes for sound to travel between the two transducers in both
directions. The difference in the transit time t measured is directly proportional to the
velocity ( V) of the liquid in the pipe.
With no flow, the transit time will be equal in both directions. With flow ultrasound will travel
faster in direction of flow &slower against the flow. The liquid velocity (V) inside the pipe
can be related to the difference in time of flight through the following equation
V = K x Dx t
Where V: Velocity of the Liquid
K: Constant
D: Distance between the two transducers
t: Difference in transmit time
MIRRANT AUTOMATION PRIVATE LIMITED
Plot No:6A/5,IDA Phase-I,Patancheru, Phone: +91 9949306860
Sangareddy Dist.,Hyderabad-502319 Email: sales@[Link] Sense. Automate. Integrate
Telangana, India Website: [Link]
ULTRASONIC flow meters
UltraFlow 2500
Features:
1. Wide flow measurement range, from 0 m/s to 32 m/s
2. Bi-directional measurement, totalize for net, positive and negative flow.
3. High accuracy, better than K 1 % of velocity
4. Suitable for all commonly used pipe materials
5. Rechargeable battery with 12 hours of operation
6. Built – in data logger or SD card .Self –explanatory user interface.
7. Windows PC software for data down-load and real time data display
8. Can also be deployed as a remote RTU for long –term flow monitoring application
9. Easy and economical installation. Ideal for both clean and opaque liquid flows.
Specifica ons:
UltraFlow 2500 Ultrasonic flow meter
Domestic water, industrial water, raw water, ground water,
Medium sewage with small particle content, Oils, Chemicals Alcohol,
acids, Beverage, Liquid food.,etc.
Diameter DN15~DN6000mm
Accuracy ±1%
Repeatability ±0.2% of Span
Medium temperature <60’C
Flow rate 0.3~32m/s
Pipe Material steel, cast iron, Ductile iron,Brass,copper,,PVC, Aluminium
Displays 4x16 English letters
Electronic Enclosure Material Plastic, Aluminium
Power supply 230VAC/110VAC/24VDC/Battery
Signal output 4~20mA, Pulse
Communication RS-232C,RS485,M-BUS,RF,GSM/GPRS,LORA/NB-IOT
Data Logger Options : SD card data ( up to 8GB based SD card capacity)
Explosion-proof Flame Proof (FLP)
Protection proof IP65; IP67 and IP68
Structure Integral, Remote
Liquid temperature -40 to 121 Deg.C. (Optional 40 to 250 Deg.C.)
Work environment Ambient temperature:-20~+60’C Ambient humidity:5%~90%
Sensors for Clamp-on Type S1 (15-100 mm), M1(50-700 mm) and L1(300- 4570 mm)
Sensors for Insertion Type Above 80mm
Sensors for Inline Type DN15~DN600mm
Types of UltaFlow 2500 Clamp-on, Insertion, Inline
MIRRANT AUTOMATION PRIVATE LIMITED
Plot No:6A/5,IDA Phase-I,Patancheru, Phone: +91 9949306860
Sangareddy Dist.,Hyderabad-502319 Email: sales@[Link] Sense. Automate. Integrate
Telangana, India Website: [Link]
ULTRASONIC flow meters
UltraFlow 2500
Flow meter Installa on Schema c:
Sensor Details:
MIRRANT AUTOMATION PRIVATE LIMITED
Plot No:6A/5,IDA Phase-I,Patancheru, Phone: +91 9949306860
Sangareddy Dist.,Hyderabad-502319 Email: sales@[Link] Sense. Automate. Integrate
Telangana, India Website: [Link]
ULTRASONIC flow meters
UltraFlow 2500
Ordering Code: Ultraflow2500
UltraFlow 2500- 0100 H S B6 F6 D4 N4 P1 S3 C2 N A P N Description
Sensor Size XXXX DN15~DN6000mm
H Hand held
P Portable (With Printer)
Type of Meter
W Wall Mount
I Inline
S DN15-100
M DN50-700
Sensor L DN300-6000
B >DN80
N Not Applicable
B1 CS/MS
B2 SS304
B3 SS316
Body Material (Inline)
B4 Plastic
B5 Brass
B6 Not Applicable
F1 CS/MS
F2 SS304
F3 SS316
Flange Material (Inline)
F4 Plastic
F5 Brass
F6 Not Applicable
D1 Flange-end
D2 Thread-end
End Connection Type (Inline)
D3 Wafer
D4 Not Applicable
N1 5 Kg/cm2
N2 10 Kg/cm2
Nominal Pressure (Inline)
N3 <40 Kg/Cm2
N4 Not Applicable
P1 230V AC
Power Supply P2 24V DC
P3 3.6V Lithium Battery
S1 4-20mA Output
Signal Output S2 Pulse Output
S3 Not Applicable
C1 Not Applicable
C2 MODBUS RS485/232 C
Communication Protocol
C3 GSM/GPRS
C4 LORA/NB-IOT
A IP 65
Protection Class B IP 67
C IP 68
P ABS Plastic
Electronic Enclosure
A Aluminium
MIRRANT AUTOMATION PRIVATE LIMITED
Sense. Automate. Integrate
Plot No:6A/5,IDA Phase-I,Patancheru, Phone: +91 9949306860
Sangareddy Dist.,Hyderabad-502319 Email: sales@[Link] Sense. Automate. Integrate
Telangana, India Website: [Link]