ITEM:YF-S201C
Product Features:
1. The appearance of this product is light and flexible, small size, easy to
install.
2. Impeller with stainless steel beads inside, always wear.
3. Seal using the upper and lower force structure will never leak.
4. Hall elements imported from Germany, and encapsulated with potting,
To prevent water, never aging.
5. All raw materials are in line with ROSH testing standards
Product Description:
Water flow sensor is mainly composed of plastic body, water rotor components and
Hall sensors.
It is installed in the water heater inlet, used to detect water flow, when the
water flow through the rotor assembly,
The magnetic rotor rotates and the rotational speed changes with the flow rate
change, the Hall sensor outputs the corresponding pulse
Signal, feedback to the controller, the controller to determine the size of water
flow, regulation.
Technical Parameters
1, the minimum rated operating voltage DC 5V-24V
2, the maximum operating current of 15 mA (DC 5V)
3, the working voltage range DC 5 ~ 18V
4, the load capacity of ≤ 10 mA (DC 5V)
5, the use of temperature range ≤ 80 ℃
6, the use of humidity range of 35% to 90% RH (no frost state)
7, to allow pressure water pressure below 1.75Mpa
8, save the temperature -25 ~ +80 ℃
9, save humidity 25% ~ 95% RH
1, the output pulse high> DC 4.5 V (input voltage DC 5 V)
2, the output pulse low <DC 0.5 V (input voltage DC 5 V)
3, precision
(Flow rate - pulse output) 1 to 25 L / min ± 3%
4, the output pulse duty cycle 50 ± 10%
5, the output rise time 0.04μ S
6, the output fall time 0.18μ S
7, the flow - pulse characteristics of the level of test pulse frequency (Hz) = [5.0Q] ± 3%
(level test) (Q for the flow L / min)
8, impact-resistant packaging products, from 50cm height X, Y, Z direction free fall to the
concrete surface without exception,
Accuracy changes within 5%.
9, insulation resistance Hall sensor and copper insulation between the valve body 100MΩ or
more. (DC 500V)
10, heat resistance in 80 ± 3 ℃ environment placed 48h, return to normal temperature 1-2h
no abnormalities, and parts without cracks, relaxation, expansion, deformation and other
phenomena, the accuracy of change within 10%.
11, cold resistance in the -20 ± 3 ℃ environment placed 48h, return to normal temperature
1-2h no abnormalities, and parts without cracks, relaxation, swelling, deformation and other
phenomena, accuracy changes within 10%.
12, moisture resistance at 40 ± 2 ℃, relative humidity 90% ~ 95% RH environment placed 72h
removed, the insulation resistance 1MΩ above.
13, pull-out strength in the lead-line applied 1N10N pull, no loose, pull off phenomenon, and
no change in performance.
14, durability at room temperature, from the inlet into the 0.1MPa water pressure to connect
1S, 0.5S off for a cycle,
Test 300,000 times without exception.
Flow - Refer to the table of pulse characteristics
Flow Pulse Error Min Max Flow Pulse Error Min Max
2 15 ±1.020 15.3 14.7 6.1 45.8 ±3.2 47.1 44.4
2.1 15.75 ±1.021 16.1 15.4 6.2 46.5 ±3.3 47.9 45.1
2.2 16.5 ±1.022 16.8 16.2 6.3 47.3 ±3.4 48.7 45.8
2.3 17.25 ±1.023 17.6 16.9 6.4 48.0 ±3.5 49.4 46.6
2.4 18 ±1.024 18.4 17.6 6.5 48.8 ±3.6 50.2 47.3
2.5 18.75 ±1.025 19.1 18.4 6.6 49.5 ±3.7 51.0 48.0
2.6 19.5 ±1.026 19.9 19.1 6.7 50.3 ±3.8 51.8 48.7
2.7 20.25 ±1.027 20.7 19.8 6.8 51.0 ±3.9 52.5 49.5
2.8 21 ±1.028 21.4 20.6 6.9 51.8 ±3.10 53.3 50.2
2.9 21.75 ±1.029 22.2 21.3 7 52.5 ±3.11 54.1 50.9
3 22.5 ±1.030 23.0 22.1 7.1 53.3 ±3.12 54.8 51.7
3.1 23.25 ±1.031 23.7 22.8 7.2 54.0 ±3.13 55.6 52.4
3.2 24 ±1.032 24.5 23.5 7.3 54.8 ±3.14 56.4 53.1
3.3 24.75 ±1.033 25.2 24.3 7.4 55.5 ±3.15 57.2 53.8
3.4 25.5 ±1.034 26.0 25.0 7.5 56.3 ±3.16 57.9 54.6
3.5 26.25 ±1.035 26.8 25.7 7.6 57.0 ±3.17 58.7 55.3
3.6 27 ±1.036 27.5 26.5 7.7 57.8 ±3.18 59.5 56.0
3.7 27.75 ±1.037 28.3 27.2 7.8 58.5 ±3.19 60.3 56.7
3.8 28.5 ±1.038 29.1 27.9 7.9 59.3 ±3.20 61.0 57.5
3.9 29.25 ±1.039 29.8 28.7 8 60.0 ±3.21 61.8 58.2
4 30 ±1.040 30.6 29.4 8.1 60.8 ±3.22 62.6 58.9
4.1 30.75 ±1.041 31.4 30.1 8.2 61.5 ±3.23 63.3 59.7
4.2 31.5 ±1.042 32.1 30.9 8.3 62.3 ±3.24 64.1 60.4
4.3 32.25 ±1.043 32.9 31.6 8.4 63.0 ±3.25 64.9 61.1
4.4 33 ±1.044 33.7 32.3 8.5 63.8 ±3.26 65.7 61.8
4.5 33.75 ±1.045 34.4 33.1 8.6 64.5 ±3.27 66.4 62.6
4.6 34.5 ±1.046 35.2 33.8 8.7 65.3 ±3.28 67.2 63.3
4.7 35.25 ±1.047 36.0 34.5 8.8 66.0 ±3.29 68.0 64.0
4.8 36 ±1.048 36.7 35.3 8.9 66.8 ±3.30 68.8 64.7
4.9 36.75 ±1.049 37.5 36.0 9 67.5 ±3.31 69.5 65.5
5 37.5 ±1.050 38.3 36.8 9.1 68.3 ±3.32 70.3 66.2
5.1 38.25 ±1.051 39.0 37.5 9.2 69.0 ±3.33 71.1 66.9
5.2 39 ±1.052 39.8 38.2 9.3 69.8 ±3.34 71.8 67.7
5.3 39.75 ±1.053 40.5 39.0 9.4 70.5 ±3.35 72.6 68.4
5.4 40.5 ±1.054 41.3 39.7 9.5 71.3 ±3.36 73.4 69.1
5.5 41.25 ±1.055 42.1 40.4 9.6 72.0 ±3.37 74.2 69.8
5.6 42 ±1.056 42.8 41.2 9.7 72.8 ±3.38 74.9 70.6
5.7 42.75 ±1.057 43.6 41.9 9.8 73.5 ±3.39 75.7 71.3
5.8 43.5 ±1.058 44.4 42.6 9.9 74.3 ±3.40 76.5 72.0
5.9 44.25 ±1.059 45.1 43.4 10 75.0 ±3.41 77.3 72.8
6 45 ±1.060 45.9 44.1 Note: Pulse (Hz) = [7.5x Flow Rate Q (L / min)]
± 3%