The document provides specifications for a BSL-2 facility in a mobile container. Key requirements include: - Dimensions of 20-25 ft length, 8-10 ft width, 8-9 ft height - Flooring and walls/ceilings made of materials like vinyl, epoxy, or CRCA sheet that allow for easy cleaning - An HVAC system with HEPA filters to maintain positive air pressure between the change room and lab - Electrical systems, plumbing, and other accessories suitable for a clean room environment

Uploaded by

ankur_haldar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views1 page

BSL-2 Clean Room Specifications

The document provides specifications for a BSL-2 facility in a mobile container. Key requirements include: - Dimensions of 20-25 ft length, 8-10 ft width, 8-9 ft height - Flooring and walls/ceilings made of materials like vinyl, epoxy, or CRCA sheet that allow for easy cleaning - An HVAC system with HEPA filters to maintain positive air pressure between the change room and lab - Electrical systems, plumbing, and other accessories suitable for a clean room environment

Uploaded by

ankur_haldar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

NATIO

NATIONAL INSTITUTE OF PHARMACEUTICAL


PHARMACEUTICA EDUCATION
TION AND RESEARCH

“C nilal Bhawan”, 168, Manicktala ad, Kolkata

niperkolkatadirectoroff e@[Link]

0086 xtn. 217)

BSL-2 Facility in a mobile container required


Clean room of BSL equired specifications:

 Dimensions of container Length 20 20-25 ft Width 8-10 ft Height 8-9 ft


 Flooring: Vinyl or Epoxy coated 2 2-4mm
4mm thickness for easy cleaning
 Wall & Ceiling: Standard wall partitions with two skins of PPGI/PPGI (0.6-1mm
thickness) over GI frame work with a sealed and insulated interior or Fabricated
with 2-3 mm CRCA SheetSheet. Should be painted with anti-microbial
anti Epoxy paint
artitions and false ceiling should create an impervious shell, which form a fully
Partitions
sealed structure.

 Covings for entire wall to floor, wall to wall & wall to ceiling joints to be provided.
 Airtight clean room doors: Flush Door finishes to be 50 mm thick 1.2-1.4 1.2 mm
thick PCGI sheet suitable to fix on 50 mm thick wall panel with provisions for
double glazing glass for all door. Dimensions (900-950) 950) x (2100-2200).
(2100 Numbers
3-4 (Single leaf)
 Room pressure maintaining system: Change room pressure should be
maintained at 10 10-15 pascal while BSL-2 Lab should be maintained at 25-30
pascal.
 HVAC system or AHU with HEPA filter (Retention: 0.3 Micron Efficiency:
99.997% Pressure drop: 25 mm of W Water column) with booster fan, AC (Nos 3),
condenser, blower.
 A Fumigator needs to be provided
 Electricals: All the required cabling, switches
switches,, arrangements etc. for the purpose
of energizing the BSL BSL-2+ Laboratory facility needs to be provided. All the
electrical fittings and fixtures in the laboratory areas should
sh be suitable for clean
room application and shall be sealedsealed. Internal sockets & lights
li wiring with 3
Phase Raw power / Genset input supply supply.
 Loft water tank 01 and effluent water tank 01 to be provided
 The effluent water tank should be treatable so that when the effluent goes to
ground water it is free from contaminants.
 Stainless steel el sink (2’×2’) with bottom enclosure and steel eye wash assembly
to be provided
 Fire alarm system to be provided
 10KVa UPS with battery should be provided.
 Miscellaneous items to be provided: The change room should have shoe racks
(2), Shoe cover dispen ser unit (1), stainless steel gowning cupboard (600-
dispenser (
650mmmm W X300mm D X 1500 1500-2000 mm H with UV Lamp), stainless steel paddle
dustbin, used linen bin and an autoclave (50L).
The BSL-2 2 main Laboratory should have

Stainless steel work table (5


(5-7’ × 3-4’) with storage facility Nos 2, stainless steel
paddle dustbin Nos 2, stainless steel stool Nos 4. Stainless steel wall racks.

 The company should do the installations, validation and provide 5 years


comprehensive warranty on the whole assembly and associated components.