0% found this document useful (0 votes)
349 views1 page

BTA16-600B Triac Specifications

The document provides product specifications for 16A TRIACS, model BTA16-600B. It is suitable for general purpose AC switching in applications such as static relays, heating regulation, induction motor starting circuits, light dimmers, and motor speed controllers. It has a maximum repetitive peak off-state voltage of 600V and peak on-state current of 16A. Electrical characteristics include an on-state voltage below 1.55V at 22.5A and a holding current below 50mA at 0.5A.

Uploaded by

Ántico le Roix
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
349 views1 page

BTA16-600B Triac Specifications

The document provides product specifications for 16A TRIACS, model BTA16-600B. It is suitable for general purpose AC switching in applications such as static relays, heating regulation, induction motor starting circuits, light dimmers, and motor speed controllers. It has a maximum repetitive peak off-state voltage of 600V and peak on-state current of 16A. Electrical characteristics include an on-state voltage below 1.55V at 22.5A and a holding current below 50mA at 0.5A.

Uploaded by

Ántico le Roix
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Product specification

16A TRIACS BTA16-600B

GENERAL DESCRIPTION
Available either in through-hole or surface-mount packages, the BTA16 - 600B triac series is
suitable for general purpose AC switching. They can be used as an ON/OFF function in applications
such as static relays, heating regulation, induction motor starting circuits... or for phase control
operation in light dimmers, motor speed controllers, ...
The snubberless versions (BTA series) are specially recommended for use on
inductive loads, thanks to their high commutation performances. By using an internal ceramic pad,
the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL standards.

O
ABSOLUTE MAXIMUM RATINGS ( Ta = 25 C)
PARAMETER Symbol Value Unit

Repetitive peak off-state voltages VDRM 600 V

peak off-state reverse voltages VRRM 600 V

RMS on-state current IT 16.0 A

Non-repetitive peak on-state current ITSM 168 A A1 A2 G

Max. Operating Junction Temperature Tj 110 o


C
TO-220AB Insulated
Storage Temperature Tstg -45~150 o
C

O
ELECTRICAL CHARACTERISTICS ( Ta = 25 C)
PARAMETER Symbol Test Conditions Min. Max Unit
Repetitive peak off-state
VDRM ID=0.1mA 600 — V
voltages

Repetitive peak off-state IDRM VDRM=520V — 10 uA


current
On-state voltage VTM IT=22.5A — 1.55 V
Holding current IH IT=0.5A,IGT=50mA — 50 mA
T2+G+ — 50
Gate trigger T2+G- — 50
IGT VAK=12V,RL=30Ω mA
Current T2-G- — 50
T2-G+ — 100
T2+G+ — 1.5
Gate trigger T2+G- — 1.5
VGT VAK=12V,RL=30Ω V
Voltage T2-G- 1.5
T2-G+ — 2.0