0% found this document useful (0 votes)
172 views3 pages

35kV Medium Voltage Cable Specifications

This document provides specifications for Vulcanel 2000 cable for medium voltage power distribution from 5kV to 35kV. The cable features a sealed compact copper conductor, cross-linked polyethylene insulation, semiconductor screens, and a polyvinyl chloride outer cover. It is suitable for underground installation and provides high dielectric strength, resistance to chemicals and moisture, and can operate at temperatures up to 250°C. The document lists over 20 product codes specifying the voltage rating, conductor size, insulation thickness, diameters, weights, and other technical specifications.

Uploaded by

Alberto Uchiha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
172 views3 pages

35kV Medium Voltage Cable Specifications

This document provides specifications for Vulcanel 2000 cable for medium voltage power distribution from 5kV to 35kV. The cable features a sealed compact copper conductor, cross-linked polyethylene insulation, semiconductor screens, and a polyvinyl chloride outer cover. It is suitable for underground installation and provides high dielectric strength, resistance to chemicals and moisture, and can operate at temperatures up to 250°C. The document lists over 20 product codes specifying the voltage rating, conductor size, insulation thickness, diameters, weights, and other technical specifications.

Uploaded by

Alberto Uchiha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Energy \ Cables for medium voltage distribution \ Medium voltage sheathing

VULCANEL 2000 CABLEMR FOR DRY ENVIRONMENTS WITH 100% XLP INSULATION
INSULATION LEVEL FROM 5kV TO 35kV SEALED COMPACT COPPER CONDUCTOR AND
PVC COVER

Description:
1- Compact round soft copper conductor, sealed against longitudinal penetration of water. 2-
Extruded semiconductor screen on the conductor. *
3- XLP (Cross Chain Polyethylene) insulation. * 4- Extruded
semiconductor screen over insulation. *
5- Metallic screen of soft copper wires applied helically. 6- Non-hygroscopic
separating tape.
7- PVC (Polyvinyl chloride) outer cover in red.

* Note: • Insulation and semiconductor shields manufactured by the true triple extrusion process
with dry curing, which significantly improves the electrical characteristics and increases the life of the
cable.

Purpose Installation Type:


• Rush • Underground pipelines
• Distribution circuits
Insulation Material:
Properties: • Cross Chain Polyethylene (XLP)
• High dielectric strength
• High dielectric strength on impulse External Cable Sheath:
• Low dielectric losses • Polyvinyl Chloride (PVC)
• Good resistance to chemical agents
• Good resistance to grease Quality certificate:
• Good resistance to abrasion • ISO 9001: 2008 quality system certified by
• Good resistance to humidity Bureau Veritas
• Good weather resistance
• Good oil resistance Product certificate:
• Good heat resistance • Proof of Acceptance of Prototypes. LAPEM-CFE
• Good ozone resistance
• Good dielectric strength • Provider Qualification Certificate. LAPEM-CFE
• Excellent resistance to penetration
longitudinal water in conductor
• Easy removal of the semiconductor screen Other information to order:
• Resistant to partial discharges • Vulcanel 2000 Cable MR for dry environments

• True triple extrusion and dry curing with 100% NA XLP insulation, phase-to-phase
voltage, with compact round soft copper
Special Features: conductor, caliber or conductor area, copper
wire screen, PVC jacket, product number and
Standards: length of sections.
• CFE E1000-16
Tension:
• 5 kV
• 15 kV
• 25 kV
• 35 kV
Temperature:
• Normal 90 ° C
• Overload 130 ° C
• Short circuit 250 ° C

25-09-2018 | HT 47 | Page 1
Energy \ Cables for medium voltage distribution \ Medium voltage sheathing

VULCANEL 2000 CABLE MR FOR DRY ENVIRONMENTS WITH XLP INSULATION 100% LEVEL OF
INSULATION FROM 5kV TO 35kV SEALED COMPACT COPPER CONDUCTOR AND PVC COVER

Area of the
Area of the Caliber
Number of Nominal thickness Diameter Number of section Diameter Nominal weight
Number of Voltage Gauge (AWG- section Diameter of wires of the
wires of of isolation nominal over wires of the transversal of the nominal exterior cable Packing Stretch
product Operation (V) kcmil) cross conductor (mm) metal screen
driver (mm) insulation (mm) metal screen metal screen (mm) (kg / km)
(mm2) (AWG)
(mm2)

16010207PA 5,000 4 21.15 7 5.36 2.30 11.13 7 22 2.27 17.70 457 REEL *
16010207QA 5,000 2 33.62 7 6.74 2.30 12.51 10 22 3.25 19.08 606 REEL *
16010204KA 5,000 1/0 53.50 19 8.46 2.30 14.24 10 22 3.25 20.81 818 REEL *
16010207RA 5,000 3/0 85.00 19 10.69 2.30 16.46 10 22 3.25 24.07 1 211 REEL *
16010207SA 5,000 250 127.00 37 13.07 2.30 19.09 14 22 4.55 26.70 1 665 REEL *
16010207TA 5,000 300 152.00 37 14.35 2.30 20.38 14 22 4.55 27.99 1 920 REEL *
16010207UA 5,000 350 177.00 37 15.54 2.30 21.57 14 22 4.55 29.18 2 180 REEL *
16010204PA 5,000 500 253.00 37 18.51 2.30 24.54 14 22 4.55 32.15 2 922 REEL *
16010207VA 5,000 750 380.00 61 22.77 2.30 29.05 18 22 5.84 37.27 4 235 REEL *
16010207WA 5,000 1000 507.00 61 26.63 2.30 32.91 18 22 5.84 41.13 5 461 REEL *
16010207XA 15,000 2 33.62 7 6.74 4.45 16.87 12 22 3.90 24.48 818 REEL *
16010204TA 15,000 1/0 53.50 19 8.46 4.45 18.60 12 22 3.90 26.21 1,046 REEL *
16010204UA 15,000 3/0 85.00 19 10.69 4.45 20.82 12 22 3.90 28.43 1 399 REEL *
16010204VA 15,000 250 127.00 37 13.07 4.45 23.45 16 22 5.20 31.06 1 870 REEL *
16010204WA 15,000 300 152.00 37 14.35 4.45 24.74 16 22 5.20 32.35 2 133 REEL *
16010204XA 15,000 350 177.00 37 15.54 4.45 25.93 16 22 5.20 34.15 2 438 REEL *
16010204YA 15,000 500 253.00 37 18.51 4.45 28.90 16 22 5.20 37.12 3 203 REEL *
16010204ZA 15,000 750 380.00 61 22.77 4.45 33.41 twenty 22 6.49 41.63 4 508 REEL *
160102050A 15,000 1000 507.00 61 26.63 4.45 37.27 twenty 22 6.49 47.15 5 945 REEL *
16010203WA 25,000 1/0 53.50 19 8.46 6.60 22.95 14 22 4.55 30.56 1 248 REEL *
16010203XA 25,000 3/0 85.00 19 10.69 6.60 25.18 14 22 4.55 32.79 1 615 REEL *
16010203YA 25,000 250 127.00 37 13.07 6.60 27.81 18 22 5.84 36.03 2 142 REEL *
16010203ZA 25,000 300 152.00 37 14.35 6.60 29.10 18 22 5.84 37.32 2 415 REEL *

25-09-2018 | HT 47 | Page 2
Energy \ Cables for medium voltage distribution \ Medium voltage sheathing

VULCANEL 2000 CABLE MR FOR DRY ENVIRONMENTS WITH XLP INSULATION 100% LEVEL OF
INSULATION FROM 5kV TO 35kV SEALED COMPACT COPPER CONDUCTOR AND PVC COVER

Area of the
Area of the Caliber
Number of Nominal thickness Diameter Number of section Diameter Nominal weight
Number of Voltage Gauge (AWG- section Diameter of wires of the
wires of of isolation nominal over wires of the transversal of the nominal exterior cable Packing Stretch
product Operation (V) kcmil) cross conductor (mm) metal screen
driver (mm) insulation (mm) metal screen metal screen (mm) (kg / km)
(mm2) (AWG)
(mm2)

160102040A 25,000 350 177.00 37 15.54 6.60 30.29 18 22 5.84 38.50 2 692 REEL *
160102041A 25,000 500 253.00 37 18.51 6.60 33.26 18 22 5.84 41.48 3 475 REEL *
160102042A 25,000 750 380.00 61 22.77 6.60 37.77 22 22 7.14 47.64 4,998 REEL *
160102043A 25,000 1000 507.00 61 26.63 6.60 41.63 22 22 7.14 52.47 6 380 REEL *
160102044A 35,000 1/0 53.50 19 8.46 8.80 27.40 16 22 5.20 35.62 1 522 REEL *
160102045A 35,000 3/0 85.00 19 10.69 8.80 29.63 16 22 5.20 37.85 1 906 REEL *
160102046A 35,000 250 127.00 37 13.07 8.80 32.26 twenty 22 6.49 40.48 2 414 REEL *
160102047A 35,000 300 152.00 37 14.35 8.80 33.55 twenty 22 6.49 41.77 2 694 REEL *
160102048A 35,000 350 177.00 37 15.54 8.80 34.74 twenty 22 6.49 44.61 3 155 REEL *
160102049A 35,000 500 253.00 37 18.51 8.80 37.71 twenty 22 6.49 47.58 3 970 REEL *
16010204AA 35,000 750 380.00 61 22.77 8.80 42.22 24 22 7.79 53.06 5 445 REEL *
16010204BA 35,000 1000 507.00 61 26.63 8.80 46.08 24 22 7.79 56.92 6 767 REEL *

Notes:
These data are approximate and are subject to manufacturing tolerances.
For constructions other than those indicated, please consult our technical advisory department.
* The product is not in stock. It can be delivered in different sections or according to the manufacturing standard.

25-09-2018 | HT 47 | Page 3