200MHz/100MHz/60MHz Digital Storage Oscilloscope
GDS-2000 Series
FEATURES
200/100/60 MHz Bandwidth
2 or 4 Input Channels
1GSa/s Real-Time and 25GSa/s Equivalent-
Time Sampling
25k Points Record Length Maximum
Large 5.6-in TFT Color Display
Summary of features Data Transfer and Printout
Rich selections of bandwidth and channel, 200/ USB host connector transfers data quickly and USB Host/Device: Support USB Printer and
100/60MHz and 2/4ch, cover major applications easily between USB flash drive, which guarantees USB Flash Drive
in laboratories, production lines, or field services. almost unlimited amount of memory. Internal
1GSa/s high sampling rate and 25k point deep storage includes 4 sets of reference waveform
and 20 sets of general-use memory area. GDS- Battery Operation (optional)
memory give much detailed view into the target
waveforms , keeping high sampling rate . USB 2000 Series handle three types of data : display
host and slave connection allows data save and image (*.bmp) for viewing waveform shape and Color Printout
pasting into documents and presentations,panel
recall, screen image printout, and remote control.
setting (*.set) for saving and restoring system
TFT color LCD display with wide viewing angle
setup, and waveform configuration (*.csv) for
eliminates obscurity in any situation . Battery further analysis of signal information. Printout
operation option gives a much-desired mobility of display image, color or grayscale, is available
in rapidly changeable environments. through the printer connected to the USB host
port. You can set the printout or data saving
Signal Detection
preference to allow a single-press operation for
GDS-2000 Series pick up signals even in the most consecutive works.
extreme cases, powered by 1GSa/s real time and
25GSa/s equivalent sampling rate combined with Setup Recovery and Transfer
3 types of acquisition modes: sample, peak detect, The last panel setting is internally stored in 1GSa/s Real-Time 4CH Selection
and average. 25k points of deep memory collects nonvolatile memory, ready to be recovered on Sampling
more information of a given waveform, guiding the next power up . When the measurement
us into further signal details. 4 types of flexible environment frequently changes, or if you want
triggers add another signal capturing flexibility: to transfer the setup to another GDS-2000 Series,
edge , video ( NTSC, PAL, SECAM ) with line switching between multiple system settings is
selection, pulse-width, and delay/event using done by saving and recalling setup files (*.set)
external trigger signal ( for 2CH models ). Using USB flash drive . When the setup gets
complicated, you can always recover the default
Measurement Functions system setting in a simple two-step operation.
A variety of measurement shortcuts reduce Remote Access USB Flash Drive Battery Operation
repetitive manual operations and save your
IEEE based remote control commands include (Optional)
precious time. Autoset automatically configures
most of the panel operations and the syntax
the horizontal scale , the vertical scale , and the conforms to universally accepted IEEE 488.2
trigger , giving an instant view of almost any standard . Proprietary PC software with GUI
signal . 27 types of automatic measurements
APPLICATIONS
operation, downloadable from GW Instek website,
include voltage , frequency ( time ) , and delay . allows you to use your familiar mouse & keyboard,
GDS-2000 Series run and update results of all utilizing the larger PC screen. Three types of Education Lab and Training Institution
the relevant measurements in real time. You can remote control interface with flexible connection
view the results independently , or together in a settings are provided: USB device, RS-232, and
single display view . Add and subtract math GPIB (optional). Production Test and Quality Inspection
operation, with 4 types of FFT are also provided :
flattop , blackman , hanning , and rectangular . Portability Repair and After-Service
Go/NoGo test function detects a user-defined Battery operation option with typ . 3 hours of
incoming waveform shape, and can also send a running time gives a much-desired mobility.
signal to external devices in case of detection. built-in self-calibration and probe compensation
Circuit Design and Debug
Program and play feature automatically runs help maintaining maximum accuracy even when
predefined sequence and setup , boosting environment or testing accessories changes .
productivity in routine measurements like Language support helps you collaborating in
production line inspection. multicultural working environments.
SPECIFICATIONS
GDS-2062/2064 GDS-2102/2104 GDS-2202/2204
VERTICAL Channels 2/4 2/4 2/4
Bandwidth DC ~ 60MHz ( 3dB) DC ~ 100MHz ( 3dB) DC ~ 200MHz ( 3dB)
Rise Time 5.8ns Approx. 3.5ns Approx. 1.75ns Approx.
Sensitivity 2mV/div ~ 5V/div (1-2-5 increments)
Accuracy (3% x |Readout|+0.05 div x Volts/div+0.8mV)
Input Coupling AC, DC & Ground
Input Impedance 1M 2%, ~16pF
Polarity Normal & Invert
Maximum Input 300V (DC+AC peak), CATII
Waveform Signal Process +, , FFT
Offset Range 2mV/div ~ 20mV/div : 0.5V ; 50mV/div ~ 200mV/div : 5V ; 500mV/div ~ 2V/div : 50V ; 5V/div : 300V
Bandwidth Limit 20MHz ( 3dB)
TRIGGER Sources CH1 , CH2 , Line , EXT(2CH Only) / (CH3,CH4)
Modes Auto-Level, AUTO, NORMAL, SINGLE, TV, Edge, Pulse Width Time-delay(2CH Only), Event-delay(2CH Only)
Coupling AC , DC , LF rej. , HF rej. , Noise rej.
Sensitivity DC ~ 25MHz : Approx. 0.5div or 5mV
25MHz ~ 60/100/200MHz : Approx. 1div or 10mV
EXT TRIGGER Range 15V
(2CH Only) Sensitivity DC ~ 30MHz : ~ 50mV ; 30M ~ 60/100/200MHz : ~100mV
Input Impedance 1M 2% , ~ 16pF
Maximum Input 300V (DC AC peak) , CATII
HORIZONTAL Range 1ns/div ~ 10s/div (1-2-5 increments); ROLL : 250ms/div ~ 10s/div
Modes MAIN, WINDOW, WINDOW ZOOM, ROLL, SCAN, X-Y
Accuracy 0.01%
Pre-Trigger 20 div maximum
Post-Trigger 1000 div
X-Y MODE X-Axis Input Channel 1
Y-Axis Input Channel 2
Phase Shift 3 at 100kHz
SIGNAL Real-Time Sample Rate 1GSa/s maximum
ACQUISITION Equivalent Sample Rate 25GSa/s maximum
Vertical Resolution 8 Bits
Record Length 25K Dots maximum
Acquisition Mode Normal, Peak Detect, Average
Peak Detection 10ns
Average 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256
CURSORS AND Voltage Measurement Vpp , Vamp , Vavg , Vrms , Vhi , Vlo , Vmax , Vmin , Rise Preshoot/ Overshoot , Fall Preshoot/Overshoot
MEASUREMENT Time Measurement Freq , Period , Rise Time , Fall Time , Positive Width , Negative Width , Duty Cycle
Delay Measurement Eight different delay measurement
Cursors Measurement Voltage difference between cursors ( V) Time difference between cursors ( T)
Auto Counter Resolution : 6 digits
Accuracy : 2%
Signal Source: All available trigger source except the Video trigger mode
CONTROL PANEL Autoset Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically
FUNCTION Save Setup Up to 20 sets of measurement conditions
Save Waveform 24 sets of waveform
DISPLAY TFT LCD Type 5.6 inch
Display Resolution 234 (Vertically) x 320 (Horizontally) Dots
Display Graticule 8 x 10 divisions ; 8 x 12 divisions (menu off)
Display Brightness Adjustable
INTERFACE Go/NoGo Output 5V Maximum/10mA TTL Open Collector Output
RS-232 Interface DB 9-pin male DTE RS-232 interface
GPIB Interface (Option) Fully programmable with IEEE 488.2 compliance
USB USB Host/Device 2.0 full speed supported
POWER SOURCE Line Voltage Range AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection
Battery Power(Option) Battery : 11.1V Li-Ion battery pack
Charge Time : 8 hours (Power ON)
Operating Time : 3 hours , depending on operating condition
MISCELLANEOUS Multi-Language Menu Available
Online Help Available
Time Clock Time and Date, Provide the Date/Time for saved data
DIMENSIONS & WEIGHT 254D 142H 310W(mm), Approx. 4.3kg
Specifications subject to change without notice. DS-2000GD0DH
Ordering Information Option Standard Accessories
GDS-2062 60MHz, 2-channel, Color LCD Display DSO Opt. 01: GPIB Interface Probe-GTP-060A:60MHz x10/x1 Switchable Passive Probe for GDS-2062/2064
GDS-2064 60MHz, 4-channel, Color LCD Display DSO Opt. 02: Battery power Probe-GTP-250A:250MHz x10/x1 Switchable Passive Probe for GDS-2202/2204
GDS-2102 100MHz, 2-channel, Color LCD Display DSO ( Factory installed, include additional Probe-GTP-100A:100MHz x10/x1 Switchable Passive Probe for GDS-2102/2104
GDS-2104 100MHz, 4-channel, Color LCD Display DSO DC Power & Battery charger circuits User Manual
GDS-2202 200MHz, 2-channel, Color LCD Display DSO and Li-lon Battery pack x 2 ) Power cord
GDS-2204 200MHz, 4-channel, Color LCD Display DSO
Calle del Ebano #16625
Jardines de Chapultepec
Tijuana B.C. Mexico
Tel. (664) 681 1130
Fax. (664) 681 1150
Tel. 01800 027-4848
www.finaltest.com.mx