100% found this document useful (1 vote)
280 views5 pages

Din16965-8 Joining Pipes

tuberia

Uploaded by

javier
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
280 views5 pages

Din16965-8 Joining Pipes

tuberia

Uploaded by

javier
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
UDC 621.643.4-036,674.046.364 Glass fibre reinfor As itis current practice in standards published | hhas been used throughout as a decimal marker, Tralaton Faciecnnena Ooecetzng reinforced plastics (GF: with DIN 16 965 Part 1 ‘must comply with DIN A form L laminated joi Pipes, nominal size 200 A wit the exp parison ofthe OM Deutscns indi Reproduction, oven in Dereon Freeman, ean. 1h of German Stancarae (Ot Norman} are BS pipe fittings and joints Laminated joints Dimensions Formsticke und Verbindungen aus glastaserverstarkten Polyesterharzen (UP-GF); Laminatverbindungen; Masse 1 Field of application This standard applies to laminated joints (form L) made of glass fibre resin) for type A, B, D or E pipes, used for joining pipes in accordance ance with DIN 16966 Part 2, Part 4 and Part 5. The laminated joints ‘This standard does not apply to elbows produced in segments 2 Dimensions, designation Laminated joints need not conform to the pictorial representation: only ‘the dimensions specified are to be adhered to, tated as follows: DEUTSCHE NORM Se rced polyester resin (UP-GF) Part 8 ‘Dy the loternational Organization for Standardization ISO), the comma Dimensions in mm K) based on unsaturated polyester resins (UP. . Part 2, Part 4 and Part § and fittings in accord: 16966 Part 7, int for pipe fittings corresponding to type D (ON 200} and for nominal pressure 10 {PN 10), ecg Oni Bondo OIN 16966 Part 8 Engl. Price group 6 ‘Sales No, 0106 Page 2 DIN 16966 Part 8 Form L Laminated joints for pipe and pipe fittings corresponding to type A pipes he | laminated ante | | | inside it agreed |, | ds a iadl type B pipes Ti | | taminated on the He | || inside agreed, i | 3 ! fi } we Its — type E pipes {4 a 7 + S| s outside diameter of the pipe 53. load bearing wall thickness overall length of laminated-over section ue nate maximum gap between the ends ofthe pi fittings free length of lining thickness of lining thickness of the chemical protective layer (type D pipes) or the highly resinous inner layer (type A and E pipes) or the bond layer (type B pipes) $5 thickness of lamination over joint oe DIN 16966 Part Page 3 Toble 1. Gap width Table 2. Laminate lengths Tin oN 4 oN corresponding to type A, 8, D and E pipes ome PNt6 | PN25 | PNG PNG PNIO | PNG T- i [= 110 —= no }— 24 = 10 =] 10 175 | "130 210 no | 105 | 260 125 | 208 | 385 250 ais | [290 | 480] 320 | 50 160.240 | 410) —s | 700 | 400) 74s 338 560 | 880 | 390 640 | 990 490 | 70/115 480 | 705) 1235 Table 3. Laminate thicknesses ON ‘Type B pipes: Type A, D and E pipes pws | puto | pnie | pNis | pN25 | PNA | PNG | PNIO | PNIE a ne = [= = = = [a2 [= = =p epee], o | - | - ‘ = TST == «|= | = = a 5 = = - = = = 45 = = =. = = = 4 5 io [=| =] as = = ‘ as ws | - | - | ss |---| =~] = = [8 wo | - | # es | - | - aT) 200 [| =} 88] es} = ‘ Ca a 250 [4 65 | ws | — 6 | wo | 16 300 | 5 a [ws | - | 4 as [7 | 18 [19 30 | ss | 9 | 15 = ss | 8 | 3s | 2 0 | 65 | ws | 17 = 6 a | iss 25 500 a 13 21 ; 5 75 115. vos | 315 coo | 98 | 155 | 25 6 o [> [2 [3 mo | 11 | 1 | 95 | 4s | os | wos | [27 [a 800 125 20,5 35 5 75 42 18.5 3 cy 900 14 23 375 55 85 135, 20,5, 38 s7 1000 155 26 42 65 95 1s 23 39 63 Page 4 DIN 16966 Part 8 3. Material Unsaturated polyester resin and textile glass as specified in DIN 16 966 Part 7. eben, selecting the resin, care should be taken to ensue tht it isthe same 2 the retin ofthe pipes and fittings to be ioined The percentage by mass of glass in the lamination over the joint must be as follows: type A pipes: 30 t0 45 % type B pipes: at least 40% type D pipes: 30 t0 45% type E pipes: 3010 45% ‘The jointing compound used to fill the gap (¢1) between the ends of the pipes or fittings must comply with the require: ‘ments specified for the material of the fittings in DIN 16966 Part 7 4 Finish For type 8 pipes the free length of the lining shall be 10 to 20 mm. Mt for type A, D and E pipes and fittings, the joint ae accessible from the inside, they may be laminated on the inside ‘over a length of 100 mm, For type D pines the taper of 30° max. can be omitted i a lamination on the inside is agreed upon Standards referred to DIN 16965 Pert 1 Giass fibre reinforced polyester resin (UP-GF) wound pipes; type A sipes, dimensions DIN 16965 Part 2. Glas fibre reinforced polyester resin (UP-GF) wound pipes, type B cipes, dimencione DIN 16.965 Part 4 Glas fibre reinforced potyester resin (UP.GF1 wound pipes: type D pipes, dimensions DIN 16965 Part § Glass fibre reinforced polyester resin (UP-GF) wound pipes: type E cipes, dimensions DIN 16966 Part 2 Glas fibre reinforced polyester resin (UP-GF) pipe fittings and joints. elbows, dimereions DIN 16966 Part 4 Glass fibre reinforced potyester resin (UP-GF} pipe fitings and joints, tees nozzles, dimensions DIN 16966 Part § Glas fibre reinforced polyester resin (UP-GF} pipe fittings and joins, reducers, dimensione DIN 16966 Part 7 Glas fibre reinforced polyester resin (UP-GF! pipe fittings and joints bushings, flanges, flenged and laminated joints, general quality requirements, testing Further standards and other documents DIN 16867 Cig Rote reinforced polyester cesin (UP-GF) pipes, fittings and joins for chemcial process pipelines; technical delivery conditions DIN 16964 Class fibre reinforced polyester resin (UP-GF) wound pipes; general quality requirements, testing 'N 18966 Part 1 Glas fibre reinforced polyester resin (UP-GF} pipe fittings ad joints: ftings, general quality requirements, testing DIN 16966 Fart 6 Glas fibre reinforced polyester resin (UP-GF) pipe fittings and joints bushings, flanges, sal, dimensions A984/77-7 Hereseanleitung: GFK lndustrierohre; Robvleitungen im Industriebervich (Pipe laying guide: glass fibre reinforced plastics; pipework in industrial plants) 1) 1) Published by Kunststoftrahiverein e.V., Dyroffstrasse 2, 0-5300 Bonn, % DIN 16966 Pan pag ge Explanations ‘This standard has been prepared by FINK Subcommittee 505.2 Industre-Rotvleitungen aus Reaktionsharzstotten se gumption made for determining the thickness ofthe lamination over the joint ss wes ther the following equation would take account of the internal pressure stresses: 42-p on,-0 a where P isthe nominal pressure in bar Ont, = 13,5 Nimm? for type A, D and E pipes aut, = 20 N/mm? for type B pipes ee Zs Content differs from the required value so that theresa corresponding variation in the stress Seat, it will be ‘necessary to reconsider the thickness requirements s. Dimension 1's the required length of the shear area and shall be calculated using the following equation: dgtp+S+s, 1 40 1 2ety ci where G2 isthe isi diameter for type A, O and E pipes, and the outside diameter of the lining for type B pipes dg_is the outside diameter Pit the nominal pressure in bar S =6 (safety factor) S1_ is production uncertainty factor 5 =8.N/mm2 £1. the maximum gap between the ends of the pipes or fittings Fe gake account of shortcomings inthe process of making laminated joints (but not defects) an additional safety factor Of Sy = 2 has been allowed in calculating the laminate lengths, ‘The specifications of this standard are essentially in agreement with the content of ISO Document ISO/T 198/6 N 889, International Patent Classification F 16.47/00

You might also like